Changes for page 01 Lua Functions
Last modified by Theodore Xu on 2023/10/26 10:51
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1370,7 +1370,6 @@ 1370 1370 ))) 1371 1371 1372 1372 1373 - 1374 1374 ((( 1375 1375 == **Data storage area(HDW/HDX)** == 1376 1376 ))) ... ... @@ -1501,7 +1501,6 @@ 1501 1501 ** addr_getstring("@W_HSW225",15) 1502 1502 1503 1503 ((( 1504 -(% class="wikigeneratedid" %) 1505 1505 == **Power-down storage area (HAW/HAX)** == 1506 1506 1507 1507 The system storage area (HAW) is used for the system power-down hold registers: ... ... @@ -1511,7 +1511,7 @@ 1511 1511 1512 1512 (% class="box infomessage" %) 1513 1513 ((( 1514 -**✎Note:** HAW/HAX is a power-down hold, that is, the registers of this type can retain the data before power-down in case of power-down 1512 +**✎Note:** HAW/HAX is a power-down hold, that is, the registers of this type can retain the data before power-down in case of power-down. 1515 1515 ))) 1516 1516 1517 1517 = **9 General Functions** = ... ... @@ -1518,13 +1518,11 @@ 1518 1518 ))) 1519 1519 1520 1520 ((( 1521 -== ** 9.1send_sms_ira(string number, string message)** ==1519 +== **send_sms_ira(string number, string message)** == 1522 1522 ))) 1523 1523 1524 -**Function:** 1522 +**Function:** Use IRA character set to send English text messages 1525 1525 1526 -Use IRA character set to send English text messages 1527 - 1528 1528 **Parameters:** 1529 1529 1530 1530 //number: //number (up to 32 characters, the excess will be discarded) ... ... @@ -1558,13 +1558,11 @@ 1558 1558 Failed: multi 1559 1559 1560 1560 ((( 1561 -== ** 9.3sms_get_state(number id)** ==1557 +== **sms_get_state(number id)** == 1562 1562 ))) 1563 1563 1564 -**Function:** 1560 +**Function:** Get the status of the SMS 1565 1565 1566 -Get the status of the SMS 1567 - 1568 1568 **parameter:** 1569 1569 1570 1570 //id~:// SMS corresponding id ... ... @@ -1576,13 +1576,11 @@ 1576 1576 Failed: multi 1577 1577 1578 1578 ((( 1579 -== ** 9.4jwt_encode(table head, table payload, string aud, number iat, number exp, string key, int jwttype)** ==1573 +== **jwt_encode(table head, table payload, string aud, number iat, number exp, string key, int jwttype)** == 1580 1580 ))) 1581 1581 1582 -**Function:** 1576 +**Function:** Convert data to JWT format 1583 1583 1584 -Convert data to JWT format 1585 - 1586 1586 **parameter:** 1587 1587 1588 1588 //aud: //project name ... ... @@ -1627,19 +1627,20 @@ 1627 1627 1628 1628 //key~:// the private key required for encryption 1629 1629 1630 -For example: 1622 +**For example:** 1631 1631 1624 +{{code language="LUA"}} 1632 1632 function jwt.main() 1633 1633 1634 -local PRIVATE_KEY = ~[~[~-~- Please enter the secret key~-~-]]1627 +local PRIVATE_KEY = [[-- Please enter the secret key--]] 1635 1635 1636 1636 local JWTType=0 1637 1637 1638 -local payload = ~{~{key="test1",value="test1",type="0"},1631 +local payload = {{key="test1",value="test1",type="0"}, 1639 1639 1640 1640 {key="test",value="123122131",type="1"}} 1641 1641 1642 -local head = ~{~{ key="name",value="data",type="0"},1635 +local head = {{ key="name",value="data",type="0"}, 1643 1643 1644 1644 {key="test2",value="test2",type="0"}} 1645 1645 ... ... @@ -1654,15 +1654,14 @@ 1654 1654 print(en) 1655 1655 1656 1656 End 1650 +{{/code}} 1657 1657 1658 1658 ((( 1659 -== ** 9.5convertohex(number type, number value)** ==1653 +== **convertohex(number type, number value)** == 1660 1660 ))) 1661 1661 1662 -**Function:** 1656 +**Function:** Convert data into hexadecimal data 1663 1663 1664 -Convert data into hexadecimal data 1665 - 1666 1666 **parameter:** 1667 1667 1668 1668 //type~:// incoming data type 0:word 1:dword 2:float ... ... @@ -1675,106 +1675,169 @@ 1675 1675 1676 1676 Failed: multi 1677 1677 1670 +== **crc.init(table prarm)** == 1671 + 1672 +**Function:** Initialize the CRC 1673 + 1674 +**Parameters:** 1675 + 1676 +prarm is a Lua table and needs to contain the following fields. 1677 + 1678 +* string prarm name, see table 9-1 for details of the parameter model name When this parameter is passed in, the default table parameters are used and the poly,init,xorout,refin,and refout passed in are invalid. 1679 +* number prarm.width: the width, i.e. the number of CRC bits. 1680 +* number [prarm.poly]: short for the generated item in hexadecimal. For example, CRC-32 is 0x04C11DB7, ignoring the highest bit "1", i.e., the complete generation item is 0x104C11DB7. 1681 +* number [prarm.init]: the initialization preset value of the register (crc) at the beginning of the algorithm in hexadecimal. 1682 +* number [prarm.xorout]: the final CRC value obtained after heterodyning the calculation result with this parameter. 1683 +* number [prarm.refin]: whether each byte of the data to be measured is inverted by bit, true or false. 1684 +* number [prarm.refout]: after the calculation or before the heterodyning output, whether the whole data is inverted by bit, true or false. 1685 + 1686 +Return: 1687 + 1688 +Success: crc object 1689 + 1690 +Failure: multi, error code 1691 + 1678 1678 ((( 1679 -== **9.6 set_network(table config)** == 1693 +|=Parameter model name|=poly|=init|=xorout|=refin|=refout 1694 +|crc8|0x07|0x00|0x00|false|false 1695 +|crc8_cdma2000|0x9B|0xFF|0x00|false|false 1696 +|crc8_darc|0x39|0x00|0x00|true|true 1697 +|crc8_dvb_s2|0xD5|0x00|0x00|false|false 1698 +|crc8_ebu|0x1D|0xFF|0x00|true|true 1699 +|crc8_i_code|0x1D|0xFD|0x00|false|false 1700 +|crc8_itu|0x07|0x00|0x55|false|false 1701 +|crc8_maxim|0x31|0x00|0x00|true|true 1702 +|crc8_rohc|0x07|0xFF|0x00|true|true 1703 +|crc8_wcdma|0x9B|0x00|0x00|true|true 1704 +|crc8_sae_j1850|0x1D|0xFF|0xFF|false|false 1705 +|crc8_opensafety|0x2F|0x00|0x00|false|false 1706 +|crc16_tms37157|0x1021|0x3791|0x0000|true|true 1707 +|crc16_a|0x1021|0x6363|0x0000|true|true 1708 +|crc16_riello|0x1021|0x554D|0x0000|true|true 1709 +|crc16_ccitt_false|0x1021|0xFFFF|0x0000|false|false 1710 +|crc16_arc|0x8005|0x0000|0x0000|true|true 1711 +|crc16_arc_ccitt|0x1021|0x1D0F|0x0000|false|false 1712 +|crc16_buypass|0x8005|0x0000|0x0000|false|false 1713 +|crc16_cdma2000|0xC867|0xFFFF|0x0000|false|false 1714 +|crc16_dds110|0x8005|0x800D|0x0000|false|false 1715 +|crc16_dect_r|0x0589|0x0000|0x0001|false|false 1716 +|crc16_dect_x|0x0589|0x0000|0x0000|false|false 1717 +|crc16_dnp|0x3D65|0x0000|0xFFFF|true|true 1718 +|crc16_en_13757|0x3D65|0x0000|0xFFFF|false|false 1719 +|crc16_genibus|0x1021|0xFFFF|0xFFFF|false|false 1720 +|crc16_maxim|0x8005|0x0000|0xFFFF|true|true 1721 +|crc16_mcrf4xx|0x1021|0xFFFF|0x0000|true|true 1722 +|crc16_t10_dif|0x8BB7|0x0000|0x0000|false|false 1723 +|crc16_teledisk|0xA097|0x0000|0x0000|false|false 1724 +|crc16_usb|0x8005|0xFFFF|0xFFFF|true|true 1725 +|crc16_kermit|0x1021|0x0000|0x0000|true|true 1726 + 1727 +(% class="wikigeneratedid" %) 1728 +Table 9-1 1729 + 1730 +== **crc:calc(string crcValue)** == 1731 + 1732 +**Function:** Calculate CRC result 1733 + 1734 +**Parameter:** 1735 + 1736 +crcValue: the value to be calculated 1737 + 1738 +**Return:** 1739 + 1740 +Succeed: calculated result 1741 + 1742 +Failed: multi, error code 1680 1680 ))) 1681 1681 1682 - **Function:**1745 +Example: 1683 1683 1684 -Set V-BOX network, take effect after restart 1747 +{{code language="LUA"}} 1748 +function crcTest.main() 1685 1685 1686 - **parameter:**1750 +local param = { 1687 1687 1688 - //config~:// incoming networkconfigurationtable1752 +name = '', 1689 1689 1690 -1. connectMode: the way V-BOX connects to the server, 0: Ethernet, 1: WIFI, 2: 4G, 3: 2G, it is not allowed to be empty. 1691 -1. ethernetEnable: Whether to enable Ethernet, 1: enable, 0: disable, and it is not allowed to be empty. 1692 -1. ethernetLanIp: Set the LAN IP address. Only V-BOX with three network ports support this configuration, and other models of V-BOX do not support setting LAN IP. This item is allowed to be empty. 1693 -1. ethernetIpMode: Whether to enable Ethernet static IP, 1: Enable static IP, 0: DHCP, not allowed to be empty. 1694 -1. ethernetIp: The IP address needs to be configured when the Ethernet static IP is used, and it is not allowed to be empty. 1695 -1. ethernetNetmask: The subnet mask needs to be configured when Ethernet static IP is used, and it is not allowed to be empty. 1696 -1. ethernetGateway: The gateway can be configured when Ethernet static IP is used. 1754 +width = 64, 1697 1697 1698 -1. When using the Ethernet network, if the Gateway is empty, V-BOX will not connect to the server. 1699 -1. If you only use Ethernet to directly connect to the PLC for communication, you do not need to configure a gateway. 1756 +poly = 0x42F0E1EBA9EA3693, 1700 1700 1701 -1. ethernetFirstDns: You can configure the preferred DNS server when the Ethernet static IP is used, and it is allowed to be empty. If you use the Ethernet network and do not fill in the DNS server, V-BOX will not be connected to the server. 1702 -1. ethernetSpareDns: Alternate DNS server can be configured when the Ethernet static IP is used, and it is allowed to be empty. 1703 -1. wifiEnable: Whether to enable WIFI, 1: enable, 0: disable, it is not allowed to be empty. If it is a model that does not include WIFI, directly disable it. 1704 -1. wifiName: WIFI name, if WIFI is enabled, it is not allowed to be empty. 1705 -1. wifiPassword: WIFI password, it is allowed to be empty. 1706 -1. wifiIpMode: Whether to enable WIFI static IP, 1: Enable static IP, 0: DHCP, not allowed to be empty. 1707 -1. wifiIp: IP address needs to be configured when WIFI static IP is used, it is not allowed to be empty. 1708 -1. wifiNetmask: The subnet mask needs to be configured when WIFI static IP is used, and it is not allowed to be empty. 1709 -1. wifiGateway: The gateway can be configured when WIFI static IP is used, and it is not allowed to be empty. 1710 -1. wifiFirstDns: You can configure the preferred DNS server when the WIFI static IP is used, and it is allowed to be empty. If you use the WIFI network and do not fill in the DNS server, V-BOX will not be connected to the server. 1711 -1. wifiSpareDns: Alternate DNS server can be configured when the WIFI static IP is used, and it is allowed to be empty. 1712 -1. mobileEnable: Whether to enable the mobile network, 1: enable, 0: disable, it is not allowed to be empty, if it does not include 4G models, directly disable it. 1713 -1. mobileApnMode: Whether to manually configure the APN, 0: Use the default APN, 1: Manually configure the APN, it is not allowed to be empty. 1714 -1. apnName: APN name, if you choose to manually configure APN, it is not allowed to be empty. 1715 -1. apnPassword: APN username, it is allowed to be empty. 1716 -1. apnUserName: APN number, it is allowed to be empty. 1717 -1. apnNumber: APN number, it is allowed to be empty. 1758 +init = 0xFFFFFFFFFFFFFFFF, 1718 1718 1719 - **Return:**1760 +xorout = 0xFFFFFFFFFFFFFFFF, 1720 1720 1721 - Succeed: true1762 +refin = 1, 1722 1722 1723 - Faied: multi1764 +refout = 1 1724 1724 1725 -((( 1726 -== **9.7 remote_com_start(string config)** == 1727 -))) 1766 +} 1728 1728 1729 - **Function:**1768 +crc64,err = crc.init(param) 1730 1730 1731 - start serialportpass-through1770 +if not crc64 then 1732 1732 1733 -**Parameter:** 1772 +print("Crc init failed:", err) 1773 +else 1734 1734 1735 - //config: //incoming serialport parameterconfiguration, JSON format1775 +crcvalue = crc64:calc("123456789") 1736 1736 1737 -1. type:0, serial port pass-through 1738 -1. port: serial port number marked on the V-BOX 1739 -1. comtype:0-RS232, 1-RS485, 2-RS422 1740 -1. baudrate: Baud Rate 1741 -1. data_length: Data Bits 1742 -1. stop_bit: Stop Bit 1743 -1. check_bit: Check Bit 1777 +print(string.format("crc64 calc :0X%16X", crcvalue)) 1744 1744 1745 - **Return:**1779 +end 1746 1746 1747 -Succeed: true 1781 +end 1782 +{{/code}} 1748 1748 1749 - Failed:multi1784 += **11 Special function for V-NET** = 1750 1750 1751 -((( 1752 -== **9.8 remote_com_stop()** == 1753 -))) 1786 +== **normal_get_alldata()** == 1754 1754 1755 -**Function:** 1788 +**Function: **Obtain the data of all the monitoring points 1756 1756 1757 - close serial port pass-through1790 +**Parameter: None** 1758 1758 1759 1759 **Return:** 1760 1760 1761 -Succeed: t rue1794 +Succeed: table two-dimensional arrays, as follows: 1762 1762 1763 -Failed: multi 1796 +* Each item is a monitoring point and contains 4 attributes: 1797 +** 1: ID 1798 +** 2: status 1799 +** 3: tag name 1800 +** 4: value 1801 +* Status contains 3 enumerated values 1802 +** 0: offline 1803 +** 1: online 1804 +** 2: timeout 1805 +* Customization returns an empty table if there is no configuration, otherwise returns "field name/field content" 1764 1764 1765 -((( 1766 -== **9.9 remote_com_state()** == 1767 -))) 1807 +For example: 1768 1768 1769 - **Function:**1809 +{ 1770 1770 1771 - querytheserialportpass-through status and pass-through server domain name andport1811 +[1]= {[1]=1234, [2]=1, [3]='temp', [4]='23.5'}, 1772 1772 1773 - **Return:**1813 +[2]= {[1]=1235, [2]=1, [3]='humi', [4]='67'}, 1774 1774 1775 - Succeed:1815 +... 1776 1776 1777 -1. number, current pass-through status: 0-none 1,2-starting pass-through 3-penetrating 4,5-finishing pass-through 6-pass-through error 1778 -1. string, pass-through server domain name and port number, xxxx (domain name): xxx (port number) 1817 +[n]= {[1]=xxxx, [2]=x, [3]='xxxx', [4]='xx.x'}, 1779 1779 1780 -Failed: multi 1819 +} 1820 + 1821 +Failed: table, empty table 1822 + 1823 +== **normal_setdata_byname(string name, string data)** == 1824 + 1825 +**Function:** Write data to the monitoring point name 1826 + 1827 +**Parameter:** 1828 + 1829 +name: the name of mo 1830 + 1831 +**Return:** 1832 + 1833 +Succeed: calculated result 1834 + 1835 +Failed: multi, error code