... ... @@ -1679,108 +1679,143 @@
1679 1679  * number prarm.width: the width, i.e. the number of CRC bits.
1680 1680  * number [prarm.poly]: short for the generated item in hexadecimal. For example, CRC-32 is 0x04C11DB7, ignoring the highest bit "1", i.e., the complete generation item is 0x104C11DB7.
1681 1681  * number [prarm.init]: the initialization preset value of the register (crc) at the beginning of the algorithm in hexadecimal.
1682 -* number [prarm.xorout], the final CRC value obtained after heterodyning the calculation result with this parameter.
1683 -* number [prarm.refin], whether each byte of the data to be measured is inverted by bit, true or false.
1684 -* number [prarm.refout], after the calculation and before the heterodyning output, whether the whole data is inverted by bit, true or false. Return: success: crc object Failure: multi, error code
1682 +* number [prarm.xorout]: the final CRC value obtained after heterodyning the calculation result with this parameter.
1683 +* number [prarm.refin]: whether each byte of the data to be measured is inverted by bit, true or false.
1684 +* number [prarm.refout]: after the calculation or before the heterodyning output, whether the whole data is inverted by bit, true or false.
1685 1685  
1686 +Return:
1687 +
1688 +Success: crc object
1689 +
1690 +Failure: multi, error code
1691 +
1686 1686  (((
1687 -== **set_network(table config)** ==
1693 +|=Parameter model name|=poly|=init|=xorout|=refin|=refout
1694 +|crc8|0x07|0x00|0x00|false|false
1695 +|crc8_cdma2000|0x9B|0xFF|0x00|false|false
1696 +|crc8_darc|0x39|0x00|0x00|true|true
1697 +|crc8_dvb_s2|0xD5|0x00|0x00|false|false
1698 +|crc8_ebu|0x1D|0xFF|0x00|true|true
1699 +|crc8_i_code|0x1D|0xFD|0x00|false|false
1700 +|crc8_itu|0x07|0x00|0x55|false|false
1701 +|crc8_maxim|0x31|0x00|0x00|true|true
1702 +|crc8_rohc|0x07|0xFF|0x00|true|true
1703 +|crc8_wcdma|0x9B|0x00|0x00|true|true
1704 +|crc8_sae_j1850|0x1D|0xFF|0xFF|false|false
1705 +|crc8_opensafety|0x2F|0x00|0x00|false|false
1706 +|crc16_tms37157|0x1021|0x3791|0x0000|true|true
1707 +|crc16_a|0x1021|0x6363|0x0000|true|true
1708 +|crc16_riello|0x1021|0x554D|0x0000|true|true
1709 +|crc16_ccitt_false|0x1021|0xFFFF|0x0000|false|false
1710 +|crc16_arc|0x8005|0x0000|0x0000|true|true
1711 +|crc16_arc_ccitt|0x1021|0x1D0F|0x0000|false|false
1712 +|crc16_buypass|0x8005|0x0000|0x0000|false|false
1713 +|crc16_cdma2000|0xC867|0xFFFF|0x0000|false|false
1714 +|crc16_dds110|0x8005|0x800D|0x0000|false|false
1715 +|crc16_dect_r|0x0589|0x0000|0x0001|false|false
1716 +|crc16_dect_x|0x0589|0x0000|0x0000|false|false
1717 +|crc16_dnp|0x3D65|0x0000|0xFFFF|true|true
1718 +|crc16_en_13757|0x3D65|0x0000|0xFFFF|false|false
1719 +|crc16_genibus|0x1021|0xFFFF|0xFFFF|false|false
1720 +|crc16_maxim|0x8005|0x0000|0xFFFF|true|true
1721 +|crc16_mcrf4xx|0x1021|0xFFFF|0x0000|true|true
1722 +|crc16_t10_dif|0x8BB7|0x0000|0x0000|false|false
1723 +|crc16_teledisk|0xA097|0x0000|0x0000|false|false
1724 +|crc16_usb|0x8005|0xFFFF|0xFFFF|true|true
1725 +|crc16_kermit|0x1021|0x0000|0x0000|true|true
1726 +
1727 +(% class="wikigeneratedid" %)
1728 +Table 9-1
1729 +
1730 +== **crc:calc(string crcValue)** ==
1731 +
1732 +**Function:** Calculate CRC result
1733 +
1734 +**Parameter:**
1735 +
1736 +crcValue: the value to be calculated
1737 +
1738 +**Return:**
1739 +
1740 +Succeed: calculated result
1741 +
1742 +Failed: multi, error code
1688 1688  )))
1689 1689  
1690 -**Function:** Set V-BOX network, take effect after restart
1745 +Example:
1691 1691  
1692 -**parameter:**
1747 +{{code language="LUA"}}
1748 +function crcTest.main()
1693 1693  
1694 -//config~:// incoming network configuration table
1750 +local param = {
1695 1695  
1696 -1. connectMode: the way V-BOX connects to the server, 0: Ethernet, 1: WIFI, 2: 4G, 3: 2G, it is not allowed to be empty.
1697 -1. ethernetEnable: Whether to enable Ethernet, 1: enable, 0: disable, and it is not allowed to be empty.
1698 -1. ethernetLanIp: Set the LAN IP address. Only V-BOX with three network ports support this configuration, and other models of V-BOX do not support setting LAN IP. This item is allowed to be empty.
1699 -1. ethernetIpMode: Whether to enable Ethernet static IP, 1: Enable static IP, 0: DHCP, not allowed to be empty.
1700 -1. ethernetIp: The IP address needs to be configured when the Ethernet static IP is used, and it is not allowed to be empty.
1701 -1. ethernetNetmask: The subnet mask needs to be configured when Ethernet static IP is used, and it is not allowed to be empty.
1702 -1. ethernetGateway: The gateway can be configured when Ethernet static IP is used.
1752 +name = '',
1703 1703  
1704 -1. When using the Ethernet network, if the Gateway is empty, V-BOX will not connect to the server.
1705 -1. If you only use Ethernet to directly connect to the PLC for communication, you do not need to configure a gateway.
1754 +width = 64,
1706 1706  
1707 -1. ethernetFirstDns: You can configure the preferred DNS server when the Ethernet static IP is used, and it is allowed to be empty. If you use the Ethernet network and do not fill in the DNS server, V-BOX will not be connected to the server.
1708 -1. ethernetSpareDns: Alternate DNS server can be configured when the Ethernet static IP is used, and it is allowed to be empty.
1709 -1. wifiEnable: Whether to enable WIFI, 1: enable, 0: disable, it is not allowed to be empty. If it is a model that does not include WIFI, directly disable it.
1710 -1. wifiName: WIFI name, if WIFI is enabled, it is not allowed to be empty.
1711 -1. wifiPassword: WIFI password, it is allowed to be empty.
1712 -1. wifiIpMode: Whether to enable WIFI static IP, 1: Enable static IP, 0: DHCP, not allowed to be empty.
1713 -1. wifiIp: IP address needs to be configured when WIFI static IP is used, it is not allowed to be empty.
1714 -1. wifiNetmask: The subnet mask needs to be configured when WIFI static IP is used, and it is not allowed to be empty.
1715 -1. wifiGateway: The gateway can be configured when WIFI static IP is used, and it is not allowed to be empty.
1716 -1. wifiFirstDns: You can configure the preferred DNS server when the WIFI static IP is used, and it is allowed to be empty. If you use the WIFI network and do not fill in the DNS server, V-BOX will not be connected to the server.
1717 -1. wifiSpareDns: Alternate DNS server can be configured when the WIFI static IP is used, and it is allowed to be empty.
1718 -1. mobileEnable: Whether to enable the mobile network, 1: enable, 0: disable, it is not allowed to be empty, if it does not include 4G models, directly disable it.
1719 -1. mobileApnMode: Whether to manually configure the APN, 0: Use the default APN, 1: Manually configure the APN, it is not allowed to be empty.
1720 -1. apnName: APN name, if you choose to manually configure APN, it is not allowed to be empty.
1721 -1. apnPassword: APN username, it is allowed to be empty.
1722 -1. apnUserName: APN number, it is allowed to be empty.
1723 -1. apnNumber: APN number, it is allowed to be empty.
1756 +poly = 0x42F0E1EBA9EA3693,
1724 1724  
1725 -**Return:**
1758 +init = 0xFFFFFFFFFFFFFFFF,
1726 1726  
1727 -Succeed: true
1760 +xorout = 0xFFFFFFFFFFFFFFFF,
1728 1728  
1729 -Faied: multi
1762 +refin = 1,
1730 1730  
1731 -(((
1732 -== **9.7 remote_com_start(string config)** ==
1733 -)))
1764 +refout = 1
1734 1734  
1735 -**Function:**
1766 +}
1736 1736  
1737 -start serial port pass-through
1768 +crc64,err = crc.init(param)
1738 1738  
1739 -**Parameter:**
1770 +if not crc64 then
1740 1740  
1741 -//config: //incoming serial port parameter configuration, JSON format
1772 +print("Crc init failed:", err)
1773 +else
1742 1742  
1743 -1. type:0, serial port pass-through
1744 -1. port: serial port number marked on the V-BOX
1745 -1. comtype:0-RS232, 1-RS485, 2-RS422
1746 -1. baudrate: Baud Rate
1747 -1. data_length: Data Bits
1748 -1. stop_bit: Stop Bit
1749 -1. check_bit: Check Bit
1775 +crcvalue = crc64:calc("123456789")
1750 1750  
1751 -**Return:**
1777 +print(string.format("crc64 calc :0X%16X", crcvalue))
1752 1752  
1753 -Succeed: true
1779 +end
1754 1754  
1755 -Failed: multi
1781 +end
1782 +{{/code}}
1756 1756  
1757 -(((
1758 -== **9.8 remote_com_stop()** ==
1759 -)))
1784 += **11 Special function for V-NET** =
1760 1760  
1761 -**Function:**
1786 +**normal_get_alldata()**
1762 1762  
1763 -close serial port pass-through
1788 +**Function: **Obtain the data of all the monitoring points
1764 1764  
1790 +**Parameter: None**
1791 +
1765 1765  **Return:**
1766 1766  
1767 -Succeed: true
1794 +Succeed: table two-dimensional arrays, as follows:
1768 1768  
1769 -Failed: multi
1796 +* Each item is a monitoring point and contains 4 attributes:
1797 +** 1: ID
1798 +** 2: status
1799 +** 3: tag name
1800 +** 4: value
1801 +* Status contains 3 enumerated values
1802 +** 0: offline
1803 +** 1: online
1804 +** 2: timeout
1805 +* Customization returns an empty table if there is no configuration, otherwise returns "field name/field content"
1770 1770  
1771 -(((
1772 -== **9.9 remote_com_state()** ==
1773 -)))
1807 +For example:
1774 1774  
1775 -**Function:**
1809 +{
1776 1776  
1777 -query the serial port pass-through status and pass-through server domain name and port
1811 +[1]= {[1]=1234, [2]=1, [3]='temp', [4]='23.5'},
1778 1778  
1779 -**Return:**
1813 +[2]= {[1]=1235, [2]=1, [3]='humi', [4]='67'},
1780 1780  
1781 -Succeed:
1815 +...
1782 1782  
1783 -1. number, current pass-through status: 0-none 1,2-starting pass-through 3-penetrating 4,5-finishing pass-through 6-pass-through error
1784 -1. string, pass-through server domain name and port number, xxxx (domain name): xxx (port number)
1817 +[n]= {[1]=xxxx, [2]=x, [3]='xxxx', [4]='xx.x'},
1785 1785  
1786 -Failed: multi
1819 +}
1820 +
1821 +Failed: table, empty table