Changes for page 01 Lua Functions
Last modified by Theodore Xu on 2023/10/26 10:51
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -V-BOX.V-Net. 1\.UserManual.04 Lua Script.WebHome1 +V-BOX.V-Net.Manual.04 Lua Script.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Stone1 +XWiki.Hunter - Content
-
... ... @@ -1,5 +1,17 @@ 1 1 = **1 Interface description** = 2 2 3 +(% style="width:749.222px" %) 4 +|=(% scope="row" style="width: 374px;" %)z|=(% style="width: 373px;" %)cxz 5 +|=(% style="width: 374px;" %) |(% style="width:373px" %) 6 +|=(% style="width: 374px;" %) |(% style="width:373px" %) 7 + 8 +|分类|宽|高 9 +|网页全屏|700-850|400 10 +|手机全屏|300|400 11 +|其他大图片|400左右|400左右 12 +|小图片|200左右|200左右 13 + 14 + 3 3 == **Data type definition** == 4 4 5 5 |=**Type**|=**Description** ... ... @@ -140,7 +140,7 @@ 140 140 141 141 Table 2-1 142 142 143 -(% class="box errormessage" %)155 +(% class="box infomessage" %) 144 144 ((( 145 145 **✎Note: **If HLword enters any other value, it will be treated as invalid. 146 146 ))) ... ... @@ -608,11 +608,12 @@ 608 608 Attempting to use a script to open a serial port in an unsupported mode will result in an error directly, as below. 609 609 610 610 |((( 623 +{{code language="LUA"}} 611 611 local setup = { 612 612 613 613 name = "COM2", 614 614 615 -mode = 422, ~-~- COM2 does not support RS422628 +mode = 422, -- COM2 does not support RS422 616 616 617 617 ... 618 618 ... ... @@ -619,6 +619,7 @@ 619 619 } 620 620 621 621 serial.open(setup) 635 +{{/code}} 622 622 ))) 623 623 624 624 **Data bit:** ... ... @@ -1063,8 +1063,9 @@ 1063 1063 1064 1064 If there is no custom configuration, return an empty table, otherwise, return with "field name/field content" 1065 1065 1066 - E.g:1080 +**For example:** 1067 1067 1082 +{{code language="LUA"}} 1068 1068 { 1069 1069 1070 1070 [1]= {[1]=1234, [2]=1, [3]='temp', [4]='23.5', [5]={"fruit"="apple"}}, ... ... @@ -1077,7 +1077,8 @@ 1077 1077 1078 1078 } 1079 1079 1080 -Failed: //table// empty table 1095 +Failed: table empty table 1096 +{{/code}} 1081 1081 1082 1082 ((( 1083 1083 == **bns_get_config(string from)** == ... ... @@ -1157,13 +1157,15 @@ 1157 1157 1158 1158 Type (1: switch, 2: number, 3: string) 1159 1159 1160 -E.g: 1161 - { 1176 +**For example:** 1162 1162 1163 -[1]={~-~-The first communication port 1178 +{{code language="LUA"}} 1179 +{ 1164 1164 1165 -[1]={ ~-~-monitoring point array of the first communication port1181 +[1]={--The first communication port 1166 1166 1183 +[1]={--monitoring point array of the first communication port 1184 + 1167 1167 [1]={[1]=11,[2]='data1',[3]=3,[4]=2}, 1168 1168 1169 1169 [2]={[1]=12,[2]='data2',[3]=3,[4]=2}, ... ... @@ -1170,23 +1170,23 @@ 1170 1170 1171 1171 ... 1172 1172 1173 -[n]={[1]=xx,[2]='datan',[3]=x,[4]=x}, ~-~-n monitoring points1191 +[n]={[1]=xx,[2]='datan',[3]=x,[4]=x},--n monitoring points 1174 1174 1175 1175 }, 1176 1176 1177 -[2]=14, ~-~-ID1195 +[2]=14, --ID 1178 1178 1179 -[3]='Modbus TCP' ~-~-n monitoring points1197 +[3]='Modbus TCP' --n monitoring points 1180 1180 1181 1181 }, 1182 1182 1183 -[2]={ ~-~-The second communication port1201 +[2]={--The second communication port 1184 1184 1185 -[1]={}, ~-~-The monitoring point of the second communication port is not configured and is empty1203 +[1]={},--The monitoring point of the second communication port is not configured and is empty 1186 1186 1187 -[2]=15, ~-~-ID1205 +[2]=15, --ID 1188 1188 1189 -[3]='WECON' ~-~-communication protocol name1207 +[3]='WECON' --communication protocol name 1190 1190 1191 1191 }, 1192 1192 ... ... @@ -1193,6 +1193,7 @@ 1193 1193 ...n communication ports and so on 1194 1194 1195 1195 } 1214 +{{/code}} 1196 1196 1197 1197 Failed~:// table// empty table 1198 1198 ... ... @@ -1272,8 +1272,9 @@ 1272 1272 1273 1273 Succeed: //table// one-dimensional array 1274 1274 1275 - E.g:1294 +**For example:** 1276 1276 1296 +{{code language="LUA"}} 1277 1277 { 1278 1278 1279 1279 [1]="This is the oldest message", - the first is the oldest message ... ... @@ -1285,6 +1285,7 @@ 1285 1285 [n]="This is the latest message", - the last is the latest message 1286 1286 1287 1287 } 1308 +{{/code}} 1288 1288 1289 1289 Failede: nil 1290 1290 ... ... @@ -1302,7 +1302,7 @@ 1302 1302 1303 1303 == **https request** == 1304 1304 1305 - Example:1326 +**For example:** 1306 1306 1307 1307 {{code language="LUA"}} 1308 1308 local json = require("json") ... ... @@ -1358,7 +1358,7 @@ 1358 1358 1359 1359 **Access in bit mode, the prefix is @B_HDX, the number in front of "." indicates the number of the word, and the number behind is the bit number of the word.** 1360 1360 1361 -For example: @B_HDX1020.12, its meaning is to access the system data area in bit mode, the specific location is the 13th bit of the 1020th word. 1382 +**For example:** @B_HDX1020.12, its meaning is to access the system data area in bit mode, the specific location is the 13th bit of the 1020th word. 1362 1362 1363 1363 (% class="box infomessage" %) 1364 1364 ((( ... ... @@ -1380,7 +1380,7 @@ 1380 1380 1. Access in bit mode, the number range is: "@B_HDX0.0"-"@B_HDX299999.15". 1381 1381 1382 1382 ((( 1383 -== ** 8.2Special data area (HSW/HSX)** ==1404 +== **Special data area (HSW/HSX)** == 1384 1384 1385 1385 (% class="box infomessage" %) 1386 1386 ((( ... ... @@ -1498,8 +1498,19 @@ 1498 1498 ** addr_getstring("@W_HSW191",17) 1499 1499 * Obtaining ICCID (read only) 1500 1500 ** addr_getstring("@W_HSW225",15) 1522 +* ((( 1523 +TSAP settings of Siemens LOGO PLC* 1501 1501 1502 1502 ((( 1526 +addr_setword("@W_0#HSW1200",8192) means set the Local TSAP as 20.00 1527 +))) 1528 + 1529 +* ((( 1530 +addr_setword("@W_0#HSW1201",4096) means set the Remote TSAP as 10.00 1531 +))) 1532 +))) 1533 + 1534 +((( 1503 1503 == **Power-down storage area (HAW/HAX)** == 1504 1504 1505 1505 The system storage area (HAW) is used for the system power-down hold registers: ... ... @@ -1534,7 +1534,7 @@ 1534 1534 Failed: multi 1535 1535 1536 1536 ((( 1537 -== ** 9.2send_sms_ucs2(string number, string message)** ==1569 +== **send_sms_ucs2(string number, string message)** == 1538 1538 ))) 1539 1539 1540 1540 **Function:** ... ... @@ -1683,7 +1683,7 @@ 1683 1683 * number [prarm.refin]: whether each byte of the data to be measured is inverted by bit, true or false. 1684 1684 * number [prarm.refout]: after the calculation or before the heterodyning output, whether the whole data is inverted by bit, true or false. 1685 1685 1686 -Return: 1718 +**Return:** 1687 1687 1688 1688 Success: crc object 1689 1689 ... ... @@ -1742,7 +1742,7 @@ 1742 1742 Failed: multi, error code 1743 1743 ))) 1744 1744 1745 - Example:1777 +**For example:** 1746 1746 1747 1747 {{code language="LUA"}} 1748 1748 function crcTest.main() ... ... @@ -1804,8 +1804,9 @@ 1804 1804 ** 2: timeout 1805 1805 * Customization returns an empty table if there is no configuration, otherwise returns "field name/field content" 1806 1806 1807 -For example: 1839 +**For example:** 1808 1808 1841 +{{code language="LUA"}} 1809 1809 { 1810 1810 1811 1811 [1]= {[1]=1234, [2]=1, [3]='temp', [4]='23.5'}, ... ... @@ -1819,6 +1819,7 @@ 1819 1819 } 1820 1820 1821 1821 Failed: table, empty table 1855 +{{/code}} 1822 1822 1823 1823 == **normal_setdata_byname(string name, string data)** == 1824 1824 ... ... @@ -1834,12 +1834,10 @@ 1834 1834 1835 1835 Succeed: string: The value of the monitor point before it is written 1836 1836 1837 -Failed: mil1871 +Failed: nil 1838 1838 1839 1839 == **normal_getdata_byname(string name)** == 1840 1840 1841 - 1842 - 1843 1843 **Function:** Read the data of the monitoring point name 1844 1844 1845 1845 **Parameter:** ... ... @@ -1850,7 +1850,7 @@ 1850 1850 1851 1851 Succeed: string 1852 1852 1853 -Failed: mil1885 +Failed: nil 1854 1854 1855 1855 = **11 MySQL database operation** = 1856 1856 ... ... @@ -1890,7 +1890,7 @@ 1890 1890 1891 1891 Succeed: status: returns the number of rows affected by SQL statement execution. 1892 1892 1893 -Failed: mil, errorString1925 +Failed: nil, errorString 1894 1894 1895 1895 == **luaMySql.execWithResult(string statement)** == 1896 1896 ... ... @@ -1904,9 +1904,9 @@ 1904 1904 1905 1905 Succeed: table: returns the result set 1906 1906 1907 -Failed: mil, errorString1939 +Failed: nil, errorString 1908 1908 1909 -For example: 1941 +**For example:** 1910 1910 1911 1911 {{code language="LUA"}} 1912 1912 mysql = require"mysqlclient" ... ... @@ -2034,14 +2034,78 @@ 2034 2034 2035 2035 == **hmac(string hash_func, string key, string message)** == 2036 2036 2037 -**Function:** Executethe given SQL statement returning the resultset (check)2069 +**Function:** HMAC calculate 2038 2038 2071 +**Function name** 2072 + 2073 +hash_func: 2074 + 2075 +* [md5, sha1, sha224, sha256, sha384, sha512] 2076 +* [sha512_224, sha512_256, sha3_224, sha3_256] 2077 +* [sha3_384, sha3_512] 2078 + 2039 2039 **Parameter:** 2040 2040 2041 - statement: thegiven SQL statement2081 +key: the key 2042 2042 2083 +message: message content 2084 + 2043 2043 **Return:** 2044 2044 2045 -Succeed: ta ble: returnstheresultset2087 +Succeed: string, calculation result 2046 2046 2047 -Failed: mil, errorString 2089 +Failed: nil 2090 + 2091 +**For example:** 2092 + 2093 +{{code language="LUA"}} 2094 +local sha = require"sha2" 2095 + 2096 +function hmac_test.main() 2097 + 2098 +local hmac = sha.hmac 2099 + 2100 +print(hmac(sha.sha1, 2101 + 2102 +"your key", "your message")) 2103 + 2104 +end 2105 +{{/code}} 2106 + 2107 +== **sha(string message** == 2108 + 2109 +**Function:** SHA calculate 2110 + 2111 +**Function name:** 2112 + 2113 +sha: 2114 + 2115 +* sha1, sha224, sha256, sha384, sha512] 2116 +* [sha512_224, sha512_256, sha3_224, sha3_256] 2117 +* [sha3_384, sha3_512] 2118 + 2119 +**Parameter:** 2120 + 2121 +key: the key 2122 + 2123 +message: message content 2124 + 2125 +**Return:** 2126 + 2127 +Succeed: string, calculation result 2128 + 2129 +Failed: nil 2130 + 2131 +For example: 2132 + 2133 +{{code language="LUA"}} 2134 +local sha = require"sha2" 2135 + 2136 +function sha_test.main() 2137 + 2138 +local sha256 = sha.sha256 2139 + 2140 +print(sha256("your message")) 2141 + 2142 +end 2143 +{{/code}}