Changes for page 03 V-NET Client
Last modified by Joe on 2024/12/27 17:41
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 10 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -26,4 +26,141 @@ 26 26 27 27 Users can jump directly to the homepage without entering the account password by clicking Offline-mode. Only some functions are worked in offline mode. Please refer to the corresponding function modules in the following specific contents. 28 28 29 += 2 Offline mode = 30 + 31 +(% style="text-align:center" %) 32 +[[image:V-NET Offline.png]] 33 + 34 +In offline mode, only some functions are available without login, like the above screenshot shows: The Display and Device Pass-through are disabled. To use the non-offline mode function, please close the V-NET Client, and restart to login account. 35 + 36 += 3 Display = 37 + 38 +(% style="text-align:center" %) 39 +[[image:V-NET homepage.png]] 40 + 41 +After logging into the software, jump to the V-NET homepage by default. 42 + 43 +(% style="text-align:center" %) 44 +[[image:New layout.png]] 45 + 46 +The Pass-through tab is no longer displayed in the main interface. But integrated into the software "Device Pass-through" function. To use the corresponding function, please refer to following chapter"Device Pass-through". 47 + 48 += 4 Device Configuration = 49 + 50 +(% style="text-align:center" %) 51 +[[image:DeviceConfiguration.png]] 52 + 53 +== Connect method == 54 + 55 +* USB direct connection 56 +* Ethernet cable in LAN 57 + 58 +(% style="text-align:center" %) 59 +[[image:Scan Segment.png]] 60 + 61 +* When the inputbox is not entered and directly click the magnifer icon, the current segment is scanned accroding to the PC IP's segment. 62 +* When the inputbox is entered and click magnifer icon, the current segment is scanned according to the input IP. 63 + 64 +== Configure network == 65 + 66 +(% style="text-align:center" %) 67 +[[image:Network Config.png]] 68 + 69 +* After V-Box is selected, configure the network for the current device 70 +* Upload is for uploads the network configuration of the current devic 71 +* ((( 72 +After downloaded, the current device will connect to the corresponding server according to downloaded configuration 73 +))) 74 + 75 +== Test network == 76 + 77 +Get the network status of the current device, see whether V-Box can ping server successfully. 78 + 79 +== Update Firmware == 80 + 81 +Compare the firmware version carried by the software with the firmware version running by the device, if the firmware version of the V-NET Client software is higher than the firmware version of the device(V-Box), choose whether to upgrade the firmware of the device. 82 + 83 +== Flash light == 84 + 85 +Let the lights of the V-Box start flashing quickly for several seconds, which is convenient for positioning where is the V-Box. 86 + 87 +== Get machine code == 88 + 89 +Get the machine code of the current connected device and copy it to the clipboard. 90 + 91 +== Update time == 92 + 93 +According to the current PC UTC time, to calibrate time of V-Box, but this would not change the time zone of V-Box. 94 + 95 +== Clear == 96 + 97 +Clear the operation log in the Operation reminder 98 + 99 += 5 Device Pass-through = 100 + 101 +== PLC Pass-through == 102 + 103 +(% style="text-align:center" %) 104 +[[image:PLC Passthrough.png]] 105 + 106 +**Functional overview** 107 + 108 +{{info}} 109 +Built on V-BOX/ig HMI and PLC on the basis of normal communication, online PLC connection according to the generated virtual serial port, allowing the PLC software communicate PLC, complete the upload/download PLC programs, monitoring PLC programs and other functions 110 +{{/info}} 111 + 112 +=== **1 Search** === 113 + 114 +Enter a device name/Machine code/Product code, device list only display the devices that meet the search criteria, and support real-time filtering 115 + 116 +(% style="text-align:center" %) 117 +[[image:PLC Passthrough Device list.png]] 118 + 119 +=== **2 Device list** === 120 + 121 +(% style="text-align:center" %) 122 +[[image:rightclick menu.png]] 123 + 124 +* Display all groupings and device names and device status under current account. 125 +* When the mouse is in the device list, right-click the menu to refresh the device list and copy the machine code/Product code. 126 +* Refresh list: Reacquire all groupings and devices under the current account number from the server. 127 +* ((( 128 +Copy machine code: Copy the current device's machine code/Product code to the clipboard. 129 +))) 130 + 131 +=== **3 Configuration template&Refresh status** === 132 + 133 +* Refresh: Refresh the current device status(offline/online/being pass-through, etc.) 134 +* New: Create a new configuration template according to current device and account 135 +** Name(required): Length limitation 1~~50, cannot duplicate 136 +** Port: Select which communication port of the device to pass-through 137 +** When the Ethernet is selected as pass-through communication port, the information user need to enter is IP address, need to conform IP address format, and port scopes from 1 to 65535 138 +** When the device type is HMI, the template need to set a waiting timeout(ranges 0~~500) 139 +* Edit: Modify the selected configuration template 140 +* Delete: Delete the selected configuration template 141 + 142 +=== **4 Device information&Configuration information** === 143 + 144 +* Device information: Status (consistent with the status in the device list), machine code 145 +* ((( 146 +Configuration information: The configuration template list according to the selected device and current account. The specific information is displayed when different configurations are selected in the drop-down list 147 +))) 148 + 149 +=== **5 Start pass-through/End pass-through** === 150 + 151 +* Click Start pass-through to proceed PLC pass-through according to the current configuration template 152 +* Click End pass-through to endPLC pass-through connection 153 +* When the device is offline, the Start pass-through button cannot be clicked 154 +* When the firmware version of device is too low, the Start pass-through button cannot be clicked 155 +* The current account does not have the permission of pass-through to this device or the device is shared by others, the Start pass-through button cannot be clicked 156 +* When the current account has a device being pass-through, the Start pass-through button cannot be clicked 157 +* After clicking the Start pass-through button, if the pass-through is successful, the button changes to End pass-through, and the device status color on the left side list changes to blue 158 + 159 +== VPN Pass-through == 160 + 161 +(% style="text-align:center" %) 162 +[[image:VPN passthrough.png]] 163 + 164 +**Functional overview** 165 + 29 29
- DeviceConfiguration.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +29.4 KB - Content
- Network Config.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +37.7 KB - Content
- New layout.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +53.0 KB - Content
- PLC Passthrough Device list.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +4.7 KB - Content
- PLC Passthrough.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +42.5 KB - Content
- Scan Segment.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +40.1 KB - Content
- V-NET Offline.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +38.6 KB - Content
- V-NET homepage.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +75.3 KB - Content
- VPN passthrough.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +33.6 KB - Content
- rightclick menu.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +14.9 KB - Content