Changes for page 03 V-NET Client

Last modified by Joe on 2024/12/27 17:41

From version 16.1
edited by Theodore Xu
on 2024/03/18 10:34
Change comment: There is no comment for this version
To version 1.3
edited by Hunter
on 2023/01/07 09:50
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -03 V-NET Client
1 +3 V-NET Client
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.AiXia
1 +XWiki.Hunter
Content
... ... @@ -1,4 +1,4 @@
1 -= Login page =
1 += 1 Login page =
2 2  
3 3  (% style="text-align:center" %)
4 4  [[image:V-NET Login.png]]
... ... @@ -26,7 +26,7 @@
26 26  
27 27  Users can jump directly to the homepage without entering the account password by clicking Offline-mode. Only some functions are worked in offline mode. Please refer to the corresponding function modules in the following specific contents.
28 28  
29 -= Offline mode =
29 += 2 Offline mode =
30 30  
31 31  (% style="text-align:center" %)
32 32  [[image:V-NET Offline.png]]
... ... @@ -33,223 +33,21 @@
33 33  
34 34  In offline mode, only some functions are available without login, like the above screenshot shows: The Display and Device Pass-through are disabled. To use the non-offline mode function, please close the V-NET Client, and restart to login account.
35 35  
36 -= Display =
36 += 3 Display =
37 37  
38 38  (% style="text-align:center" %)
39 39  [[image:V-NET homepage.png]]
40 40  
41 -After logging into the software, jump to the V-NET homepage by default.
41 +After logging into the software, jump to the V-NET homepage by default
42 42  
43 43  (% style="text-align:center" %)
44 44  [[image:New layout.png]]
45 45  
46 -The Pass-through tab is no longer displayed in the main interface. But integrated into the software "Device Pass-through" function. To use the corresponding function, please refer to following chapter [[Device Pass-through>>https://docs.we-con.com.cn/bin/view/V-BOX/V-Net/Manual/VPN%20passthrough/]].
46 +The Pass-through tab is no longer displayed in the main interface. But integrated into the software "Device Pass-through" function. To use the corresponding function, please refer to following chapter"Device Pass-through"
47 47  
48 -= Device Configuration =
48 += 4 Device Configuration =
49 49  
50 50  (% style="text-align:center" %)
51 51  [[image:DeviceConfiguration.png]]
52 52  
53 -== Connect method ==
54 -
55 -* USB direct connection
56 -* Ethernet cable in LAN
57 -
58 -(% style="text-align:center" %)
59 -[[image:Scan Segment.png]]
60 -
61 -* When the inputbox is not entered and directly click the magnifer icon, the current segment is scanned accroding to the PC IP's segment.
62 -* When the inputbox is entered and click magnifer icon, the current segment is scanned according to the input IP.
63 -
64 -== Configure network ==
65 -
66 -(% style="text-align:center" %)
67 -[[image:Network Config.png]]
68 -
69 -* After V-Box is selected, configure the network for the current device
70 -* Upload is for uploads the network configuration of the current devic
71 -* (((
72 -After downloaded, the current device will connect to the corresponding server according to downloaded configuration
73 -)))
74 -
75 -== Test network ==
76 -
77 -Get the network status of the current device, see whether V-Box can ping server successfully.
78 -
79 -== Flash light ==
80 -
81 -Let the lights of the V-Box start flashing quickly for several seconds, which is convenient for positioning where is the V-Box.
82 -
83 -== Get machine code ==
84 -
85 -Get the machine code of the current connected device and copy it to the clipboard.
86 -
87 -== Update time ==
88 -
89 -According to the current PC UTC time, to calibrate time of V-Box, but this would not change the time zone of V-Box.
90 -
91 -== Clear ==
92 -
93 -Clear the operation log in the Operation reminder
94 -
95 -= Device Pass-through =
96 -
97 -== PLC Pass-through ==
98 -
99 -(% style="text-align:center" %)
100 -[[image:PLC Passthrough.png]]
101 -
102 -**Functional overview**
103 -
104 -{{info}}
105 -Built on V-BOX/ig HMI and PLC on the basis of normal communication, online PLC connection according to the generated virtual serial port, allowing the PLC software communicate PLC, complete the upload/download PLC programs, monitoring PLC programs and other functions
106 -{{/info}}
107 -
108 -=== **Search** ===
109 -
110 -Enter a device name/Machine code/Product code, device list only display the devices that meet the search criteria, and support real-time filtering**Device list**
111 -
112 -(% style="text-align:center" %)
113 -[[image:rightclick menu.png]]
114 -
115 -* Display all groupings and device names and device status under current account.
116 -* When the mouse is in the device list, right-click the menu to refresh the device list and copy the machine code/Product code.
117 -* Refresh list: Reacquire all groupings and devices under the current account number from the server.
118 -* (((
119 -Copy machine code: Copy the current device's machine code/Product code to the clipboard.
120 -)))
121 -
122 -=== **Configuration template&Refresh status** ===
123 -
124 -* Refresh: Refresh the current device status(offline/online/being pass-through, etc.)
125 -* New: Create a new configuration template according to current device and account
126 -** Name(required): Length limitation 1~~50, cannot duplicate
127 -** Port: Select which communication port of the device to pass-through
128 -** When the Ethernet is selected as pass-through communication port, the information user need to enter is IP address, need to conform IP address format, and port scopes from 1 to 65535
129 -** When the device type is HMI, the template need to set a waiting timeout(ranges 0~~500)
130 -* Edit: Modify the selected configuration template
131 -* Delete: Delete the selected configuration template
132 -
133 -=== **Device information&Configuration information** ===
134 -
135 -* Device information: Status (consistent with the status in the device list), machine code
136 -* (((
137 -Configuration information: The configuration template list according to the selected device and current account. The specific information is displayed when different configurations are selected in the drop-down list
138 -)))
139 -
140 -=== **Start pass-through/End pass-through** ===
141 -
142 -* Click Start pass-through to proceed PLC pass-through according to the current configuration template
143 -* Click End pass-through to end PLC pass-through connection
144 -* When the device is offline, the Start pass-through button cannot be clicked
145 -* When the firmware version of device is too low, the Start pass-through button cannot be clicked
146 -* The current account does not have the permission of pass-through to this device or the device is shared by others, the Start pass-through button cannot be clicked
147 -* When the current account has a device being pass-through, the Start pass-through button cannot be clicked
148 -* After clicking the Start pass-through button, if the pass-through is successful, the button changes to End pass-through, and the device status color on the left side list changes to blue
149 -
150 -== [[VPN Pass-through>>doc:V-BOX.V-Net.Manual.VPN passthrough.WebHome]] ==
151 -
152 -== HMI Pass-through ==
153 -
154 -(% style="text-align:center" %)
155 -[[image:HMI Passthrough.png]]
156 -
157 -**Functional overview**
158 -
159 -{{info}}
160 -Select the download tool path in the installed PIStudio, pop up the download tool after successfully start pass-through , and select PC->HMI, and select the compiled .wmt or .wmt3 file, the program can be downloaded to the HMI. After the project downloaded, HMI will automatically restart.
161 -{{/info}}
162 -
163 -=== **Device list** ===
164 -
165 -* Display all support HMI devices under current account
166 -* Right-click menu, search box is consistent with PLC pass-through
167 -
168 -=== **HMI Download tool configuration** ===
169 -
170 -The folder where the selected download tool is located and the corresponding PIStudio version information
171 -
172 -=== **Browse** ===
173 -
174 -Click Browse to find out if the selected folder containsPIStudioand download tools(Need to ensure existence)
175 -
176 -=== **ReOpen** ===
177 -
178 -When click start pass-through, and the download tool is closed due to some situation after opened it, click ReOpen to open the download tool again
179 -
180 -=== **HMI Download tool list** ===
181 -
182 -* Automatically search and detect the installed PIStudio on this PC, and display all installed download tools and their versions when enter the HMI pass-through page
183 -* Select any option in the table, download tool configuration area display the corresponding selected option's information, and saves the selected HMIdownload tool configuration at the same time
184 -
185 -=== **Device information** ===
186 -
187 -Display device status and machine code
188 -
189 -=== **Start pass-through/End pass-through** ===
190 -
191 -* Click Start pass-through, proceed pass-through according to the specified download tool and the selected device
192 -* Click End pass-through to end HMI pass-through
193 -* When the device is offline, the Start pass-through button cannot be clicked
194 -* When the firmware version of the device is too low, the Start pass-through button cannot be clicked
195 -* The current account does not have the permission of pass-through to this device or the device is shared by others, the Start pass-through button cannot be clicked
196 -* When the current account has a device being pass-through, the Start pass-through button cannot be clicked
197 -* After clicking the Start pass-through button, the pass-through is successful, the button changes to End pass-through, and the device status color on the left side changes to orange, and the selected download tool is opened at the same time
198 -* (((
199 -The download tool is opened correctly: Machine code can be obtained and detected HMI firmware version
200 -)))
201 -
202 -(% style="text-align:center" %)
203 -[[image:Success passthrough download tool.png]]
204 -
205 -= Tools =
206 -
207 -== ARP Scan ==
208 -
209 -(% style="text-align:center" %)
210 -[[image:ARP scan.png]]
211 -
212 -* Scan selectable network adapters
213 -* Click the Scan button to scan all devices' IP address and the corresponding MAC address in the same network segment within the setting timeout
214 -* (((
215 -The scanned device will be displayed on the list, which can help to judge whether the current device exists IP conflict problem or not
216 -)))
217 -
218 -== OPC Tool ==
219 -
220 -(% style="text-align:center" %)
221 -[[image:OPC tool.png]]
222 -
223 -* The software is built-inOPCtool, no need to download additionally, about the specific operation of OPC tool, please refer to the [[OPC tool>>doc:V-BOX.V-Net.Manual.7 OPC tool.WebHome]]
224 -* OPC tools can be found in the home menu bar->Tools->OPC tool
225 -
226 -= Configuration =
227 -
228 -(% style="text-align:center" %)
229 -[[image:Configuration.png]]
230 -
231 -== Server Select ==
232 -
233 -Select the specified server, switch servers, and return to the login page
234 -
235 -== Virtual Serial Port ==
236 -
237 -* Enable When using the PLC pass-through, need to use the virtual serial port function
238 -* Select serial port: Choose the current idle serial port as the virtual serial port independently, so as to avoid access another new USB device conflict
239 -
240 -== [[Firmware Update>>https://docs.we-con.com.cn/bin/view/V-BOX/V-Net/Manual/3%20V-NET%20Client/3.3%20Firmware%20upgrade/]] ==
241 -
242 -== ==
243 -
244 -== Cache Clear ==
245 -
246 -Click this button to restart the software and clear cef folder cache
247 -
248 -= Help =
249 -
250 -(% style="text-align:center" %)
251 -[[image:AboutUs.png]]
252 -
253 -* Display software-related information
254 -* Display APP and WeChat applet QR code
255 -* Display company information
53 +
ARP scan.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -21.0 KB
Content
AboutUs.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -70.6 KB
Content
Configuration.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -70.0 KB
Content
HMI Passthrough.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -46.3 KB
Content
Network Config.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -37.7 KB
Content
OPC tool.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -27.4 KB
Content
PLC Passthrough Device list.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -4.7 KB
Content
PLC Passthrough.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -42.5 KB
Content
Scan Segment.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -40.1 KB
Content
Success passthrough download tool.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -15.5 KB
Content
VPN passthrough.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -33.6 KB
Content
rightclick menu.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Hunter
Size
... ... @@ -1,1 +1,0 @@
1 -14.9 KB
Content