Changes for page 03 V-NET Client
Last modified by Joe on 2024/12/27 17:41
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -149,7 +149,7 @@ 149 149 === **5 Start pass-through/End pass-through** === 150 150 151 151 * Click Start pass-through to proceed PLC pass-through according to the current configuration template 152 -* Click End pass-through to endPLC pass-through connection 152 +* Click End pass-through to end PLC pass-through connection 153 153 * When the device is offline, the Start pass-through button cannot be clicked 154 154 * When the firmware version of device is too low, the Start pass-through button cannot be clicked 155 155 * The current account does not have the permission of pass-through to this device or the device is shared by others, the Start pass-through button cannot be clicked ... ... @@ -167,4 +167,61 @@ 167 167 VPN pass-through is to add PC to the Local Area Network where the device is located. It can be imagined that PC "replaces" the device at this time, and PC can access any PLC in this Local Area Network where the device is located. 168 168 {{/info}} 169 169 170 +=== **1 Device list** === 171 + 172 +* Display all support VPN pass-through devices under current account 173 +* ((( 174 +Right-click menu, search box is consistent with PLC pass-through 175 +))) 176 + 177 +=== **2 Remote LAN IP** === 178 + 179 +VPN pass-through required parameters, DHCP/Static IP of pass-through IP 180 + 181 +=== **3 Device information** === 182 + 183 +Display device machine code, name, device status and other information 184 + 185 +=== **4 Start pass-through/End pass-through** === 186 + 187 +* Click Start pass-through, proceed VPN pass-through according to the setting LAN pass-through IP 188 +* Click End pass-through to end VPN pass-through 189 +* When the device is offline, the Start pass-through button cannot be clicked 190 +* When the firmware version of the device is too low, the Start pass-through button cannot be clicked 191 +* The current account does not have the permission of pass-through to this device or the device is shared by others, the Start pass-through button cannot be clicked 192 +* When the current account has a device being pass-through, the Start pass-through button cannot be clicked 193 +* ((( 194 +After clicking the Start pass-through button, the pass-through is successful, the button changes to End pass-through, and the device status color on the left side changes to yellow 195 +))) 196 + 197 +== HMI Pass-through == 198 + 199 +(% style="text-align:center" %) 200 +[[image:HMI Passthrough.png]] 201 + 202 +**Functional overview** 203 + 204 +{{info}} 205 +Select the download tool path in the installed PIStudio, pop up the download tool after successfully start pass-through , and select PC->HMI, and select the compiled .wmt or .wmt3 file, the program can be downloaded to the HMI. After the project downloaded, HMI will automatically restart. 206 +{{/info}} 207 + 208 +=== **1 Device list** === 209 + 210 +* Display all support HMI devices under current account 211 +* Right-click menu, search box is consistent with PLC pass-through 212 + 213 +=== **2 HMI Download tool configuration** === 214 + 215 +The folder where the selected download tool is located and the corresponding PIStudio version information 216 + 217 +=== **3 Browse** === 218 + 219 +Click Browse to find out if the selected folder containsPIStudioand download tools(Need to ensure existence) 220 + 221 +=== **4 ReOpen** === 222 + 223 +When click start pass-through, and the download tool is closed due to some situation after opened it, click ReOpen to open the download tool again 224 + 225 + 226 + 170 170
- HMI Passthrough.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +46.3 KB - Content