Changes for page 03 V-NET Client

Last modified by Joe on 2024/12/27 17:41

From version 2.10
edited by Hunter
on 2023/01/07 11:21
Change comment: There is no comment for this version
To version 3.1
edited by Hunter
on 2023/01/07 11:46
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -149,7 +149,7 @@
149 149  === **5 Start pass-through/End pass-through** ===
150 150  
151 151  * Click Start pass-through to proceed PLC pass-through according to the current configuration template
152 -* Click End pass-through to endPLC pass-through connection
152 +* Click End pass-through to end PLC pass-through connection
153 153  * When the device is offline, the Start pass-through button cannot be clicked
154 154  * When the firmware version of device is too low, the Start pass-through button cannot be clicked
155 155  * The current account does not have the permission of pass-through to this device or the device is shared by others, the Start pass-through button cannot be clicked
... ... @@ -167,4 +167,84 @@
167 167  VPN pass-through is to add PC to the Local Area Network where the device is located. It can be imagined that PC "replaces" the device at this time, and PC can access any PLC in this Local Area Network where the device is located.
168 168  {{/info}}
169 169  
170 -
170 +=== **1 Device list** ===
171 +
172 +* Display all support VPN pass-through devices under current account
173 +* (((
174 +Right-click menu, search box is consistent with PLC pass-through
175 +)))
176 +
177 +=== **2 Remote LAN IP** ===
178 +
179 +VPN pass-through required parameters, DHCP/Static IP of pass-through IP
180 +
181 +=== **3 Device information** ===
182 +
183 +Display device machine code, name, device status and other information
184 +
185 +=== **4 Start pass-through/End pass-through** ===
186 +
187 +* Click Start pass-through, proceed VPN pass-through according to the setting LAN pass-through IP
188 +* Click End pass-through to end VPN pass-through
189 +* When the device is offline, the Start pass-through button cannot be clicked
190 +* When the firmware version of the device is too low, the Start pass-through button cannot be clicked
191 +* The current account does not have the permission of pass-through to this device or the device is shared by others, the Start pass-through button cannot be clicked
192 +* When the current account has a device being pass-through, the Start pass-through button cannot be clicked
193 +* (((
194 +After clicking the Start pass-through button, the pass-through is successful, the button changes to End pass-through, and the device status color on the left side changes to yellow
195 +)))
196 +
197 +== HMI Pass-through ==
198 +
199 +(% style="text-align:center" %)
200 +[[image:HMI Passthrough.png]]
201 +
202 +**Functional overview**
203 +
204 +{{info}}
205 +Select the download tool path in the installed PIStudio, pop up the download tool after successfully start pass-through , and select PC->HMI, and select the compiled .wmt or .wmt3 file, the program can be downloaded to the HMI. After the project downloaded, HMI will automatically restart.
206 +{{/info}}
207 +
208 +=== **1 Device list** ===
209 +
210 +* Display all support HMI devices under current account
211 +* Right-click menu, search box is consistent with PLC pass-through
212 +
213 +=== **2 HMI Download tool configuration** ===
214 +
215 +The folder where the selected download tool is located and the corresponding PIStudio version information
216 +
217 +=== **3 Browse** ===
218 +
219 +Click Browse to find out if the selected folder containsPIStudioand download tools(Need to ensure existence)
220 +
221 +=== **4 ReOpen** ===
222 +
223 +When click start pass-through, and the download tool is closed due to some situation after opened it, click ReOpen to open the download tool again
224 +
225 +=== **5 HMI Download tool list** ===
226 +
227 +* Automatically search and detect the installed PIStudio on this PC, and display all installed download tools and their versions when enter the HMI pass-through page
228 +* Select any option in the table, download tool configuration area display the corresponding selected option's information, and saves the selected HMIdownload tool configuration at the same time
229 +
230 +=== **6 Device information** ===
231 +
232 +Display device status and machine code
233 +
234 +=== **7 Start pass-through/End pass-through** ===
235 +
236 +* Click Start pass-through, proceed pass-through according to the specified download tool and the selected device
237 +* Click End pass-through to end HMI pass-through
238 +* When the device is offline, the Start pass-through button cannot be clicked
239 +* When the firmware version of the device is too low, the Start pass-through button cannot be clicked
240 +* The current account does not have the permission of pass-through to this device or the device is shared by others, the Start pass-through button cannot be clicked
241 +* When the current account has a device being pass-through, the Start pass-through button cannot be clicked
242 +* After clicking the Start pass-through button, the pass-through is successful, the button changes to End pass-through, and the device status color on the left side changes to orange, and the selected download tool is opened at the same time
243 +* (((
244 +The download tool is opened correctly: Machine code can be obtained and detected HMI firmware version
245 +)))
246 +
247 +(% style="text-align:center" %)
248 +[[image:Success passthrough download tool.png]]
249 +
250 += 6 Tools =
HMI Passthrough.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +46.3 KB
Content
Success passthrough download tool.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +15.5 KB
Content