Changes for page 03 V-NET Client
Last modified by Joe on 2024/12/27 17:41
From version 2.3
edited by Hunter
on 2023/01/07 10:08
on 2023/01/07 10:08
Change comment:
There is no comment for this version
To version 11.1
edited by Theodore Xu
on 2023/07/06 16:55
on 2023/07/06 16:55
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 10 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Hunter1 +XWiki.AiXia - Content
-
... ... @@ -38,12 +38,12 @@ 38 38 (% style="text-align:center" %) 39 39 [[image:V-NET homepage.png]] 40 40 41 -After logging into the software, jump to the V-NET homepage by default 41 +After logging into the software, jump to the V-NET homepage by default. 42 42 43 43 (% style="text-align:center" %) 44 44 [[image:New layout.png]] 45 45 46 -The Pass-through tab is no longer displayed in the main interface. But integrated into the software "Device Pass-through" function. To use the corresponding function, please refer to following chapter "Device Pass-through"46 +The Pass-through tab is no longer displayed in the main interface. But integrated into the software "Device Pass-through" function. To use the corresponding function, please refer to following chapter [[Device Pass-through>>https://docs.we-con.com.cn/bin/view/V-BOX/V-Net/Manual/3%20V-NET%20Client/#H5DevicePass-through]]. 47 47 48 48 = 4 Device Configuration = 49 49 ... ... @@ -72,4 +72,194 @@ 72 72 After downloaded, the current device will connect to the corresponding server according to downloaded configuration 73 73 ))) 74 74 75 - 75 +== Test network == 76 + 77 +Get the network status of the current device, see whether V-Box can ping server successfully. 78 + 79 +== Flash light == 80 + 81 +Let the lights of the V-Box start flashing quickly for several seconds, which is convenient for positioning where is the V-Box. 82 + 83 +== Get machine code == 84 + 85 +Get the machine code of the current connected device and copy it to the clipboard. 86 + 87 +== Update time == 88 + 89 +According to the current PC UTC time, to calibrate time of V-Box, but this would not change the time zone of V-Box. 90 + 91 +== Clear == 92 + 93 +Clear the operation log in the Operation reminder 94 + 95 += 5 Device Pass-through = 96 + 97 +== PLC Pass-through == 98 + 99 +(% style="text-align:center" %) 100 +[[image:PLC Passthrough.png]] 101 + 102 +**Functional overview** 103 + 104 +{{info}} 105 +Built on V-BOX/ig HMI and PLC on the basis of normal communication, online PLC connection according to the generated virtual serial port, allowing the PLC software communicate PLC, complete the upload/download PLC programs, monitoring PLC programs and other functions 106 +{{/info}} 107 + 108 +=== **1 Search** === 109 + 110 +Enter a device name/Machine code/Product code, device list only display the devices that meet the search criteria, and support real-time filtering 111 + 112 +(% style="text-align:center" %) 113 +[[image:PLC Passthrough Device list.png]] 114 + 115 +=== **2 Device list** === 116 + 117 +(% style="text-align:center" %) 118 +[[image:rightclick menu.png]] 119 + 120 +* Display all groupings and device names and device status under current account. 121 +* When the mouse is in the device list, right-click the menu to refresh the device list and copy the machine code/Product code. 122 +* Refresh list: Reacquire all groupings and devices under the current account number from the server. 123 +* ((( 124 +Copy machine code: Copy the current device's machine code/Product code to the clipboard. 125 +))) 126 + 127 +=== **3 Configuration template&Refresh status** === 128 + 129 +* Refresh: Refresh the current device status(offline/online/being pass-through, etc.) 130 +* New: Create a new configuration template according to current device and account 131 +** Name(required): Length limitation 1~~50, cannot duplicate 132 +** Port: Select which communication port of the device to pass-through 133 +** When the Ethernet is selected as pass-through communication port, the information user need to enter is IP address, need to conform IP address format, and port scopes from 1 to 65535 134 +** When the device type is HMI, the template need to set a waiting timeout(ranges 0~~500) 135 +* Edit: Modify the selected configuration template 136 +* Delete: Delete the selected configuration template 137 + 138 +=== **4 Device information&Configuration information** === 139 + 140 +* Device information: Status (consistent with the status in the device list), machine code 141 +* ((( 142 +Configuration information: The configuration template list according to the selected device and current account. The specific information is displayed when different configurations are selected in the drop-down list 143 +))) 144 + 145 +=== **5 Start pass-through/End pass-through** === 146 + 147 +* Click Start pass-through to proceed PLC pass-through according to the current configuration template 148 +* Click End pass-through to end PLC pass-through connection 149 +* When the device is offline, the Start pass-through button cannot be clicked 150 +* When the firmware version of device is too low, the Start pass-through button cannot be clicked 151 +* The current account does not have the permission of pass-through to this device or the device is shared by others, the Start pass-through button cannot be clicked 152 +* When the current account has a device being pass-through, the Start pass-through button cannot be clicked 153 +* After clicking the Start pass-through button, if the pass-through is successful, the button changes to End pass-through, and the device status color on the left side list changes to blue 154 + 155 +== VPN Pass-through:[[link>>doc:V-BOX.V-Net.Manual.VPN passthrough.WebHome]] == 156 + 157 +== HMI Pass-through == 158 + 159 +(% style="text-align:center" %) 160 +[[image:HMI Passthrough.png]] 161 + 162 +**Functional overview** 163 + 164 +{{info}} 165 +Select the download tool path in the installed PIStudio, pop up the download tool after successfully start pass-through , and select PC->HMI, and select the compiled .wmt or .wmt3 file, the program can be downloaded to the HMI. After the project downloaded, HMI will automatically restart. 166 +{{/info}} 167 + 168 +=== **1 Device list** === 169 + 170 +* Display all support HMI devices under current account 171 +* Right-click menu, search box is consistent with PLC pass-through 172 + 173 +=== **2 HMI Download tool configuration** === 174 + 175 +The folder where the selected download tool is located and the corresponding PIStudio version information 176 + 177 +=== **3 Browse** === 178 + 179 +Click Browse to find out if the selected folder containsPIStudioand download tools(Need to ensure existence) 180 + 181 +=== **4 ReOpen** === 182 + 183 +When click start pass-through, and the download tool is closed due to some situation after opened it, click ReOpen to open the download tool again 184 + 185 +=== **5 HMI Download tool list** === 186 + 187 +* Automatically search and detect the installed PIStudio on this PC, and display all installed download tools and their versions when enter the HMI pass-through page 188 +* Select any option in the table, download tool configuration area display the corresponding selected option's information, and saves the selected HMIdownload tool configuration at the same time 189 + 190 +=== **6 Device information** === 191 + 192 +Display device status and machine code 193 + 194 +=== **7 Start pass-through/End pass-through** === 195 + 196 +* Click Start pass-through, proceed pass-through according to the specified download tool and the selected device 197 +* Click End pass-through to end HMI pass-through 198 +* When the device is offline, the Start pass-through button cannot be clicked 199 +* When the firmware version of the device is too low, the Start pass-through button cannot be clicked 200 +* The current account does not have the permission of pass-through to this device or the device is shared by others, the Start pass-through button cannot be clicked 201 +* When the current account has a device being pass-through, the Start pass-through button cannot be clicked 202 +* After clicking the Start pass-through button, the pass-through is successful, the button changes to End pass-through, and the device status color on the left side changes to orange, and the selected download tool is opened at the same time 203 +* ((( 204 +The download tool is opened correctly: Machine code can be obtained and detected HMI firmware version 205 +))) 206 + 207 +(% style="text-align:center" %) 208 +[[image:Success passthrough download tool.png]] 209 + 210 += 6 Tools = 211 + 212 +== ARP Scan == 213 + 214 +(% style="text-align:center" %) 215 +[[image:ARP scan.png]] 216 + 217 +* Scan selectable network adapters 218 +* Click the Scan button to scan all devices' IP address and the corresponding MAC address in the same network segment within the setting timeout 219 +* ((( 220 +The scanned device will be displayed on the list, which can help to judge whether the current device exists IP conflict problem or not 221 +))) 222 + 223 +== OPC Tool == 224 + 225 +(% style="text-align:center" %) 226 +[[image:OPC tool.png]] 227 + 228 +* The software is built-inOPCtool, no need to download additionally, about the specific operation of OPC tool, please refer to the [[OPC tool>>doc:V-BOX.V-Net.Manual.7 OPC tool.WebHome]] 229 +* OPC tools can be found in the home menu bar->Tools->OPC tool 230 + 231 += 7 Configuration = 232 + 233 +(% style="text-align:center" %) 234 +[[image:Configuration.png]] 235 + 236 +== Server Select == 237 + 238 +Select the specified server, switch servers, and return to the login page 239 + 240 +== Virtual Serial Port == 241 + 242 +* Enable When using the PLC pass-through, need to use the virtual serial port function 243 +* Select serial port: Choose the current idle serial port as the virtual serial port independently, so as to avoid access another new USB device conflict 244 + 245 +== Firmware Update == 246 + 247 +Compare the firmware version carried by the software with the firmware version running by the device, if the firmware version of the V-NET Client software is higher than the firmware version of the device(V-Box), choose whether to upgrade the firmware of the device. 248 + 249 +* Auto Update: Automatically detect whether the firmware version carried by the current V-NET Client software is the latest firmware on the server during the software running 250 +* Manual Update: Need to click manually to compare the firmware version carried by the current V-NET Client software with the latest firmware version on the server 251 + 252 +== == 253 + 254 +== Cache Clear == 255 + 256 +Click this button to restart the software and clear cef folder cache 257 + 258 += 8 Help = 259 + 260 +(% style="text-align:center" %) 261 +[[image:AboutUs.png]] 262 + 263 +* Display software-related information 264 +* Display APP and WeChat applet QR code 265 +* Display company information
- ARP scan.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +21.0 KB - Content
- AboutUs.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +70.6 KB - Content
- Configuration.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +70.0 KB - Content
- HMI Passthrough.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +46.3 KB - Content
- OPC tool.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +27.4 KB - Content
- PLC Passthrough Device list.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +4.7 KB - Content
- PLC Passthrough.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +42.5 KB - Content
- Success passthrough download tool.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +15.5 KB - Content
- VPN passthrough.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +33.6 KB - Content
- rightclick menu.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +14.9 KB - Content