Changes for page 03 V-NET Client

Last modified by Joe on 2024/12/27 17:41

From version 2.7
edited by Hunter
on 2023/01/07 10:35
Change comment: There is no comment for this version
To version 7.1
edited by Hunter
on 2023/02/28 10:55
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -43,7 +43,7 @@
43 43  (% style="text-align:center" %)
44 44  [[image:New layout.png]]
45 45  
46 -The Pass-through tab is no longer displayed in the main interface. But integrated into the software "Device Pass-through" function. To use the corresponding function, please refer to following chapter"Device Pass-through".
46 +The Pass-through tab is no longer displayed in the main interface. But integrated into the software "Device Pass-through" function. To use the corresponding function, please refer to following chapter [[Device Pass-through>>https://docs.we-con.com.cn/bin/view/V-BOX/V-Net/Manual/3%20V-NET%20Client/#H5DevicePass-through]].
47 47  
48 48  = 4 Device Configuration =
49 49  
... ... @@ -109,4 +109,201 @@
109 109  Built on V-BOX/ig HMI and PLC on the basis of normal communication, online PLC connection according to the generated virtual serial port, allowing the PLC software communicate PLC, complete the upload/download PLC programs, monitoring PLC programs and other functions
110 110  {{/info}}
111 111  
112 +=== **1 Search** ===
113 +
114 +Enter a device name/Machine code/Product code, device list only display the devices that meet the search criteria, and support real-time filtering
115 +
116 +(% style="text-align:center" %)
117 +[[image:PLC Passthrough Device list.png]]
118 +
119 +=== **2 Device list** ===
120 +
121 +(% style="text-align:center" %)
122 +[[image:rightclick menu.png]]
123 +
124 +* Display all groupings and device names and device status under current account.
125 +* When the mouse is in the device list, right-click the menu to refresh the device list and copy the machine code/Product code.
126 +* Refresh list: Reacquire all groupings and devices under the current account number from the server.
127 +* (((
128 +Copy machine code: Copy the current device's machine code/Product code to the clipboard.
129 +)))
130 +
131 +=== **3 Configuration template&Refresh status** ===
132 +
133 +* Refresh: Refresh the current device status(offline/online/being pass-through, etc.)
134 +* New: Create a new configuration template according to current device and account
135 +** Name(required): Length limitation 1~~50, cannot duplicate
136 +** Port: Select which communication port of the device to pass-through
137 +** When the Ethernet is selected as pass-through communication port, the information user need to enter is IP address, need to conform IP address format, and port scopes from 1 to 65535
138 +** When the device type is HMI, the template need to set a waiting timeout(ranges 0~~500)
139 +* Edit: Modify the selected configuration template
140 +* Delete: Delete the selected configuration template
141 +
142 +=== **4 Device information&Configuration information** ===
143 +
144 +* Device information: Status (consistent with the status in the device list), machine code
145 +* (((
146 +Configuration information: The configuration template list according to the selected device and current account. The specific information is displayed when different configurations are selected in the drop-down list
147 +)))
148 +
149 +=== **5 Start pass-through/End pass-through** ===
150 +
151 +* Click Start pass-through to proceed PLC pass-through according to the current configuration template
152 +* Click End pass-through to end PLC pass-through connection
153 +* When the device is offline, the Start pass-through button cannot be clicked
154 +* When the firmware version of device is too low, the Start pass-through button cannot be clicked
155 +* The current account does not have the permission of pass-through to this device or the device is shared by others, the Start pass-through button cannot be clicked
156 +* When the current account has a device being pass-through, the Start pass-through button cannot be clicked
157 +* After clicking the Start pass-through button, if the pass-through is successful, the button changes to End pass-through, and the device status color on the left side list changes to blue
158 +
159 +== WVPN Pass-through ==
160 +
161 +(% style="text-align:center" %)
162 +[[image:VPN passthrough.png]]
163 +
164 +**Functional overview**
165 +
166 +{{info}}
167 +VPN pass-through is to add PC to the Local Area Network where the device is located. It can be imagined that PC "replaces" the device at this time, and PC can access any PLC in this Local Area Network where the device is located.
168 +{{/info}}
169 +
170 +=== **1 Device list** ===
171 +
172 +* Display all support VPN pass-through devices under current account
173 +* (((
174 +Right-click menu, search box is consistent with PLC pass-through
175 +)))
176 +
177 +=== **2 Remote LAN IP** ===
178 +
179 +VPN pass-through required parameters, DHCP/Static IP of pass-through IP
180 +
181 +=== **3 Device information** ===
182 +
183 +Display device machine code, name, device status and other information
184 +
185 +=== **4 Start pass-through/End pass-through** ===
186 +
187 +* Click Start pass-through, proceed VPN pass-through according to the setting LAN pass-through IP
188 +* Click End pass-through to end VPN pass-through
189 +* When the device is offline, the Start pass-through button cannot be clicked
190 +* When the firmware version of the device is too low, the Start pass-through button cannot be clicked
191 +* The current account does not have the permission of pass-through to this device or the device is shared by others, the Start pass-through button cannot be clicked
192 +* When the current account has a device being pass-through, the Start pass-through button cannot be clicked
193 +* (((
194 +After clicking the Start pass-through button, the pass-through is successful, the button changes to End pass-through, and the device status color on the left side changes to yellow
195 +)))
196 +
197 +{{info}}
198 +✎Note: The WVPN connection only lasting for 2 hours after user connect successfully, suggest to close the connection manually after done the debugging.
199 +{{/info}}
200 +
112 112  
202 +
203 +== HMI Pass-through ==
204 +
205 +(% style="text-align:center" %)
206 +[[image:HMI Passthrough.png]]
207 +
208 +**Functional overview**
209 +
210 +{{info}}
211 +Select the download tool path in the installed PIStudio, pop up the download tool after successfully start pass-through , and select PC->HMI, and select the compiled .wmt or .wmt3 file, the program can be downloaded to the HMI. After the project downloaded, HMI will automatically restart.
212 +{{/info}}
213 +
214 +=== **1 Device list** ===
215 +
216 +* Display all support HMI devices under current account
217 +* Right-click menu, search box is consistent with PLC pass-through
218 +
219 +=== **2 HMI Download tool configuration** ===
220 +
221 +The folder where the selected download tool is located and the corresponding PIStudio version information
222 +
223 +=== **3 Browse** ===
224 +
225 +Click Browse to find out if the selected folder containsPIStudioand download tools(Need to ensure existence)
226 +
227 +=== **4 ReOpen** ===
228 +
229 +When click start pass-through, and the download tool is closed due to some situation after opened it, click ReOpen to open the download tool again
230 +
231 +=== **5 HMI Download tool list** ===
232 +
233 +* Automatically search and detect the installed PIStudio on this PC, and display all installed download tools and their versions when enter the HMI pass-through page
234 +* Select any option in the table, download tool configuration area display the corresponding selected option's information, and saves the selected HMIdownload tool configuration at the same time
235 +
236 +=== **6 Device information** ===
237 +
238 +Display device status and machine code
239 +
240 +=== **7 Start pass-through/End pass-through** ===
241 +
242 +* Click Start pass-through, proceed pass-through according to the specified download tool and the selected device
243 +* Click End pass-through to end HMI pass-through
244 +* When the device is offline, the Start pass-through button cannot be clicked
245 +* When the firmware version of the device is too low, the Start pass-through button cannot be clicked
246 +* The current account does not have the permission of pass-through to this device or the device is shared by others, the Start pass-through button cannot be clicked
247 +* When the current account has a device being pass-through, the Start pass-through button cannot be clicked
248 +* After clicking the Start pass-through button, the pass-through is successful, the button changes to End pass-through, and the device status color on the left side changes to orange, and the selected download tool is opened at the same time
249 +* (((
250 +The download tool is opened correctly: Machine code can be obtained and detected HMI firmware version
251 +)))
252 +
253 +(% style="text-align:center" %)
254 +[[image:Success passthrough download tool.png]]
255 +
256 += 6 Tools =
257 +
258 +== ARP Scan ==
259 +
260 +(% style="text-align:center" %)
261 +[[image:ARP scan.png]]
262 +
263 +* Scan selectable network adapters
264 +* Click the Scan button to scan all devices' IP address and the corresponding MAC address in the same network segment within the setting timeout
265 +* (((
266 +The scanned device will be displayed on the list, which can help to judge whether the current device exists IP conflict problem or not
267 +)))
268 +
269 +== OPC Tool ==
270 +
271 +(% style="text-align:center" %)
272 +[[image:OPC tool.png]]
273 +
274 +* The software is built-inOPCtool, no need to download additionally, about the specific operation of OPC tool, please refer to the [[OPC tool>>doc:V-BOX.V-Net.Manual.7 OPC tool.WebHome]]
275 +* OPC tools can be found in the home menu bar->Tools->OPC tool
276 +
277 += 7 Configuration =
278 +
279 +(% style="text-align:center" %)
280 +[[image:Configuration.png]]
281 +
282 +== Server Select ==
283 +
284 +Select the specified server, switch servers, and return to the login page
285 +
286 +== Virtual Serial Port ==
287 +
288 +* Enable When using the PLC pass-through, need to use the virtual serial port function
289 +* Select serial port: Choose the current idle serial port as the virtual serial port independently, so as to avoid access another new USB device conflict
290 +
291 +== Firmware Update ==
292 +
293 +Compare the firmware version carried by the current V-NET Client software with the latest firmware on the server. If not, choose to update the firmware version carried by the software
294 +
295 +* Auto Update: Automatically detect whether the firmware version carried by the current V-NET Client software is the latest firmware on the server during the software running
296 +* Manual Update: Need to click manually to compare the firmware version carried by the current V-NET Client software with the latest firmware version on the server
297 +
298 +== Cache Clear ==
299 +
300 +Click this button to restart the software and clear cef folder cache
301 +
302 += 8 Help =
303 +
304 +(% style="text-align:center" %)
305 +[[image:AboutUs.png]]
306 +
307 +* Display software-related information
308 +* Display APP and WeChat applet QR code
309 +* Display company information
ARP scan.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +21.0 KB
Content
AboutUs.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +70.6 KB
Content
Configuration.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +70.0 KB
Content
HMI Passthrough.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +46.3 KB
Content
OPC tool.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +27.4 KB
Content
PLC Passthrough Device list.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +4.7 KB
Content
Success passthrough download tool.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +15.5 KB
Content
VPN passthrough.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +33.6 KB
Content
rightclick menu.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +14.9 KB
Content