Changes for page 03 V-NET Client

Last modified by Joe on 2024/12/27 17:41

From version 2.8
edited by Hunter
on 2023/01/07 10:49
Change comment: There is no comment for this version
To version 16.1
edited by Theodore Xu
on 2024/03/18 10:34
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -3 V-NET Client
1 +03 V-NET Client
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Hunter
1 +XWiki.AiXia
Content
... ... @@ -1,4 +1,4 @@
1 -= 1 Login page =
1 += Login page =
2 2  
3 3  (% style="text-align:center" %)
4 4  [[image:V-NET Login.png]]
... ... @@ -26,7 +26,7 @@
26 26  
27 27  Users can jump directly to the homepage without entering the account password by clicking Offline-mode. Only some functions are worked in offline mode. Please refer to the corresponding function modules in the following specific contents.
28 28  
29 -= 2 Offline mode =
29 += Offline mode =
30 30  
31 31  (% style="text-align:center" %)
32 32  [[image:V-NET Offline.png]]
... ... @@ -33,7 +33,7 @@
33 33  
34 34  In offline mode, only some functions are available without login, like the above screenshot shows: The Display and Device Pass-through are disabled. To use the non-offline mode function, please close the V-NET Client, and restart to login account.
35 35  
36 -= 3 Display =
36 += Display =
37 37  
38 38  (% style="text-align:center" %)
39 39  [[image:V-NET homepage.png]]
... ... @@ -43,9 +43,9 @@
43 43  (% style="text-align:center" %)
44 44  [[image:New layout.png]]
45 45  
46 -The Pass-through tab is no longer displayed in the main interface. But integrated into the software "Device Pass-through" function. To use the corresponding function, please refer to following chapter"Device Pass-through".
46 +The Pass-through tab is no longer displayed in the main interface. But integrated into the software "Device Pass-through" function. To use the corresponding function, please refer to following chapter [[Device Pass-through>>https://docs.we-con.com.cn/bin/view/V-BOX/V-Net/Manual/VPN%20passthrough/]].
47 47  
48 -= 4 Device Configuration =
48 += Device Configuration =
49 49  
50 50  (% style="text-align:center" %)
51 51  [[image:DeviceConfiguration.png]]
... ... @@ -76,10 +76,6 @@
76 76  
77 77  Get the network status of the current device, see whether V-Box can ping server successfully.
78 78  
79 -== Update Firmware ==
80 -
81 -Compare the firmware version carried by the software with the firmware version running by the device, if the firmware version of the V-NET Client software is higher than the firmware version of the device(V-Box), choose whether to upgrade the firmware of the device.
82 -
83 83  == Flash light ==
84 84  
85 85  Let the lights of the V-Box start flashing quickly for several seconds, which is convenient for positioning where is the V-Box.
... ... @@ -96,7 +96,7 @@
96 96  
97 97  Clear the operation log in the Operation reminder
98 98  
99 -= 5 Device Pass-through =
95 += Device Pass-through =
100 100  
101 101  == PLC Pass-through ==
102 102  
... ... @@ -109,16 +109,11 @@
109 109  Built on V-BOX/ig HMI and PLC on the basis of normal communication, online PLC connection according to the generated virtual serial port, allowing the PLC software communicate PLC, complete the upload/download PLC programs, monitoring PLC programs and other functions
110 110  {{/info}}
111 111  
112 -=== **1 Search** ===
108 +=== **Search** ===
113 113  
114 -Enter a device name/Machine code/Product code, device list only display the devices that meet the search criteria, and support real-time filtering
110 +Enter a device name/Machine code/Product code, device list only display the devices that meet the search criteria, and support real-time filtering**Device list**
115 115  
116 116  (% style="text-align:center" %)
117 -[[image:PLC Passthrough Device list.png]]
118 -
119 -=== **2 Device list** ===
120 -
121 -(% style="text-align:center" %)
122 122  [[image:rightclick menu.png]]
123 123  
124 124  * Display all groupings and device names and device status under current account.
... ... @@ -128,4 +128,137 @@
128 128  Copy machine code: Copy the current device's machine code/Product code to the clipboard.
129 129  )))
130 130  
131 -
122 +=== **Configuration template&Refresh status** ===
123 +
124 +* Refresh: Refresh the current device status(offline/online/being pass-through, etc.)
125 +* New: Create a new configuration template according to current device and account
126 +** Name(required): Length limitation 1~~50, cannot duplicate
127 +** Port: Select which communication port of the device to pass-through
128 +** When the Ethernet is selected as pass-through communication port, the information user need to enter is IP address, need to conform IP address format, and port scopes from 1 to 65535
129 +** When the device type is HMI, the template need to set a waiting timeout(ranges 0~~500)
130 +* Edit: Modify the selected configuration template
131 +* Delete: Delete the selected configuration template
132 +
133 +=== **Device information&Configuration information** ===
134 +
135 +* Device information: Status (consistent with the status in the device list), machine code
136 +* (((
137 +Configuration information: The configuration template list according to the selected device and current account. The specific information is displayed when different configurations are selected in the drop-down list
138 +)))
139 +
140 +=== **Start pass-through/End pass-through** ===
141 +
142 +* Click Start pass-through to proceed PLC pass-through according to the current configuration template
143 +* Click End pass-through to end PLC pass-through connection
144 +* When the device is offline, the Start pass-through button cannot be clicked
145 +* When the firmware version of device is too low, the Start pass-through button cannot be clicked
146 +* The current account does not have the permission of pass-through to this device or the device is shared by others, the Start pass-through button cannot be clicked
147 +* When the current account has a device being pass-through, the Start pass-through button cannot be clicked
148 +* After clicking the Start pass-through button, if the pass-through is successful, the button changes to End pass-through, and the device status color on the left side list changes to blue
149 +
150 +== [[VPN Pass-through>>doc:V-BOX.V-Net.Manual.VPN passthrough.WebHome]] ==
151 +
152 +== HMI Pass-through ==
153 +
154 +(% style="text-align:center" %)
155 +[[image:HMI Passthrough.png]]
156 +
157 +**Functional overview**
158 +
159 +{{info}}
160 +Select the download tool path in the installed PIStudio, pop up the download tool after successfully start pass-through , and select PC->HMI, and select the compiled .wmt or .wmt3 file, the program can be downloaded to the HMI. After the project downloaded, HMI will automatically restart.
161 +{{/info}}
162 +
163 +=== **Device list** ===
164 +
165 +* Display all support HMI devices under current account
166 +* Right-click menu, search box is consistent with PLC pass-through
167 +
168 +=== **HMI Download tool configuration** ===
169 +
170 +The folder where the selected download tool is located and the corresponding PIStudio version information
171 +
172 +=== **Browse** ===
173 +
174 +Click Browse to find out if the selected folder containsPIStudioand download tools(Need to ensure existence)
175 +
176 +=== **ReOpen** ===
177 +
178 +When click start pass-through, and the download tool is closed due to some situation after opened it, click ReOpen to open the download tool again
179 +
180 +=== **HMI Download tool list** ===
181 +
182 +* Automatically search and detect the installed PIStudio on this PC, and display all installed download tools and their versions when enter the HMI pass-through page
183 +* Select any option in the table, download tool configuration area display the corresponding selected option's information, and saves the selected HMIdownload tool configuration at the same time
184 +
185 +=== **Device information** ===
186 +
187 +Display device status and machine code
188 +
189 +=== **Start pass-through/End pass-through** ===
190 +
191 +* Click Start pass-through, proceed pass-through according to the specified download tool and the selected device
192 +* Click End pass-through to end HMI pass-through
193 +* When the device is offline, the Start pass-through button cannot be clicked
194 +* When the firmware version of the device is too low, the Start pass-through button cannot be clicked
195 +* The current account does not have the permission of pass-through to this device or the device is shared by others, the Start pass-through button cannot be clicked
196 +* When the current account has a device being pass-through, the Start pass-through button cannot be clicked
197 +* After clicking the Start pass-through button, the pass-through is successful, the button changes to End pass-through, and the device status color on the left side changes to orange, and the selected download tool is opened at the same time
198 +* (((
199 +The download tool is opened correctly: Machine code can be obtained and detected HMI firmware version
200 +)))
201 +
202 +(% style="text-align:center" %)
203 +[[image:Success passthrough download tool.png]]
204 +
205 += Tools =
206 +
207 +== ARP Scan ==
208 +
209 +(% style="text-align:center" %)
210 +[[image:ARP scan.png]]
211 +
212 +* Scan selectable network adapters
213 +* Click the Scan button to scan all devices' IP address and the corresponding MAC address in the same network segment within the setting timeout
214 +* (((
215 +The scanned device will be displayed on the list, which can help to judge whether the current device exists IP conflict problem or not
216 +)))
217 +
218 +== OPC Tool ==
219 +
220 +(% style="text-align:center" %)
221 +[[image:OPC tool.png]]
222 +
223 +* The software is built-inOPCtool, no need to download additionally, about the specific operation of OPC tool, please refer to the [[OPC tool>>doc:V-BOX.V-Net.Manual.7 OPC tool.WebHome]]
224 +* OPC tools can be found in the home menu bar->Tools->OPC tool
225 +
226 += Configuration =
227 +
228 +(% style="text-align:center" %)
229 +[[image:Configuration.png]]
230 +
231 +== Server Select ==
232 +
233 +Select the specified server, switch servers, and return to the login page
234 +
235 +== Virtual Serial Port ==
236 +
237 +* Enable When using the PLC pass-through, need to use the virtual serial port function
238 +* Select serial port: Choose the current idle serial port as the virtual serial port independently, so as to avoid access another new USB device conflict
239 +
240 +== [[Firmware Update>>https://docs.we-con.com.cn/bin/view/V-BOX/V-Net/Manual/3%20V-NET%20Client/3.3%20Firmware%20upgrade/]] ==
241 +
242 +== ==
243 +
244 +== Cache Clear ==
245 +
246 +Click this button to restart the software and clear cef folder cache
247 +
248 += Help =
249 +
250 +(% style="text-align:center" %)
251 +[[image:AboutUs.png]]
252 +
253 +* Display software-related information
254 +* Display APP and WeChat applet QR code
255 +* Display company information
ARP scan.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +21.0 KB
Content
AboutUs.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +70.6 KB
Content
Configuration.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +70.0 KB
Content
HMI Passthrough.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +46.3 KB
Content
OPC tool.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +27.4 KB
Content
Success passthrough download tool.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +15.5 KB
Content
VPN passthrough.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +33.6 KB
Content