Changes for page 03 V-NET Client
Last modified by Joe on 2024/12/27 17:41
From version 3.1
edited by Hunter
on 2023/01/07 11:46
on 2023/01/07 11:46
Change comment:
There is no comment for this version
To version 10.1
edited by Theodore Xu
on 2023/07/06 10:06
on 2023/07/06 10:06
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 4 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Hunter1 +XWiki.AiXia - Content
-
... ... @@ -43,7 +43,7 @@ 43 43 (% style="text-align:center" %) 44 44 [[image:New layout.png]] 45 45 46 -The Pass-through tab is no longer displayed in the main interface. But integrated into the software "Device Pass-through" function. To use the corresponding function, please refer to following chapter "Device Pass-through".46 +The Pass-through tab is no longer displayed in the main interface. But integrated into the software "Device Pass-through" function. To use the corresponding function, please refer to following chapter [[Device Pass-through>>https://docs.we-con.com.cn/bin/view/V-BOX/V-Net/Manual/3%20V-NET%20Client/#H5DevicePass-through]]. 47 47 48 48 = 4 Device Configuration = 49 49 ... ... @@ -76,10 +76,6 @@ 76 76 77 77 Get the network status of the current device, see whether V-Box can ping server successfully. 78 78 79 -== Update Firmware == 80 - 81 -Compare the firmware version carried by the software with the firmware version running by the device, if the firmware version of the V-NET Client software is higher than the firmware version of the device(V-Box), choose whether to upgrade the firmware of the device. 82 - 83 83 == Flash light == 84 84 85 85 Let the lights of the V-Box start flashing quickly for several seconds, which is convenient for positioning where is the V-Box. ... ... @@ -194,6 +194,12 @@ 194 194 After clicking the Start pass-through button, the pass-through is successful, the button changes to End pass-through, and the device status color on the left side changes to yellow 195 195 ))) 196 196 193 +{{info}} 194 +✎Note: The WVPN connection only lasting for 2 hours after user connect successfully, suggest to close the connection manually after done the debugging. 195 +{{/info}} 196 + 197 + 198 + 197 197 == HMI Pass-through == 198 198 199 199 (% style="text-align:center" %) ... ... @@ -248,3 +248,58 @@ 248 248 [[image:Success passthrough download tool.png]] 249 249 250 250 = 6 Tools = 253 + 254 +== ARP Scan == 255 + 256 +(% style="text-align:center" %) 257 +[[image:ARP scan.png]] 258 + 259 +* Scan selectable network adapters 260 +* Click the Scan button to scan all devices' IP address and the corresponding MAC address in the same network segment within the setting timeout 261 +* ((( 262 +The scanned device will be displayed on the list, which can help to judge whether the current device exists IP conflict problem or not 263 +))) 264 + 265 +== OPC Tool == 266 + 267 +(% style="text-align:center" %) 268 +[[image:OPC tool.png]] 269 + 270 +* The software is built-inOPCtool, no need to download additionally, about the specific operation of OPC tool, please refer to the [[OPC tool>>doc:V-BOX.V-Net.Manual.7 OPC tool.WebHome]] 271 +* OPC tools can be found in the home menu bar->Tools->OPC tool 272 + 273 += 7 Configuration = 274 + 275 +(% style="text-align:center" %) 276 +[[image:Configuration.png]] 277 + 278 +== Server Select == 279 + 280 +Select the specified server, switch servers, and return to the login page 281 + 282 +== Virtual Serial Port == 283 + 284 +* Enable When using the PLC pass-through, need to use the virtual serial port function 285 +* Select serial port: Choose the current idle serial port as the virtual serial port independently, so as to avoid access another new USB device conflict 286 + 287 +== Firmware Update == 288 + 289 +Compare the firmware version carried by the software with the firmware version running by the device, if the firmware version of the V-NET Client software is higher than the firmware version of the device(V-Box), choose whether to upgrade the firmware of the device. 290 + 291 +* Auto Update: Automatically detect whether the firmware version carried by the current V-NET Client software is the latest firmware on the server during the software running 292 +* Manual Update: Need to click manually to compare the firmware version carried by the current V-NET Client software with the latest firmware version on the server 293 + 294 +== == 295 + 296 +== Cache Clear == 297 + 298 +Click this button to restart the software and clear cef folder cache 299 + 300 += 8 Help = 301 + 302 +(% style="text-align:center" %) 303 +[[image:AboutUs.png]] 304 + 305 +* Display software-related information 306 +* Display APP and WeChat applet QR code 307 +* Display company information
- ARP scan.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +21.0 KB - Content
- AboutUs.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +70.6 KB - Content
- Configuration.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +70.0 KB - Content
- OPC tool.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +27.4 KB - Content