14.1 | 1 | = Login page = |
![]() |
1.1 | 2 | |
3 | (% style="text-align:center" %) | ||
4 | [[image:V-NET Login.png]] | ||
5 | |||
6 | == Language switch == | ||
7 | |||
8 | Switch the display language of the software through the first drop-down list. Currently, there are two languages: Simplified Chinese, English. | ||
9 | |||
10 | == Server selection == | ||
11 | |||
12 | Users can switch servers connected to on the software through the second drop-down list. | ||
13 | |||
14 | == User login == | ||
15 | |||
16 | * Enter the correct account password to log in successfully | ||
17 | * If the same account is in differentPCLogin on the different device at the same time, the account logged on the first device will be forced to log off | ||
18 | * The view account does not have permission to use the device pass-through function on the home page | ||
19 | |||
20 | == Remember password == | ||
21 | |||
22 | * If check this option, after entering the correct password and log in successfully, V-NET Client software would remember the password | ||
23 | * Users can select remembered account and password to log in directly through the inputbox drop-down list without repeatedly entering the password | ||
24 | |||
25 | == Offline mode == | ||
26 | |||
27 | Users can jump directly to the homepage without entering the account password by clicking Offline-mode. Only some functions are worked in offline mode. Please refer to the corresponding function modules in the following specific contents. | ||
28 | |||
![]() |
14.1 | 29 | = Offline mode = |
![]() |
1.2 | 30 | |
31 | (% style="text-align:center" %) | ||
32 | [[image:V-NET Offline.png]] | ||
33 | |||
34 | In offline mode, only some functions are available without login, like the above screenshot shows: The Display and Device Pass-through are disabled. To use the non-offline mode function, please close the V-NET Client, and restart to login account. | ||
35 | |||
![]() |
14.1 | 36 | = Display = |
![]() |
1.2 | 37 | |
38 | (% style="text-align:center" %) | ||
39 | [[image:V-NET homepage.png]] | ||
40 | |||
![]() |
2.4 | 41 | After logging into the software, jump to the V-NET homepage by default. |
![]() |
1.2 | 42 | |
43 | (% style="text-align:center" %) | ||
44 | [[image:New layout.png]] | ||
45 | |||
![]() |
6.1 | 46 | The Pass-through tab is no longer displayed in the main interface. But integrated into the software "Device Pass-through" function. To use the corresponding function, please refer to following chapter [[Device Pass-through>>https://docs.we-con.com.cn/bin/view/V-BOX/V-Net/Manual/3%20V-NET%20Client/#H5DevicePass-through]]. |
![]() |
1.2 | 47 | |
![]() |
14.1 | 48 | = Device Configuration = |
![]() |
1.3 | 49 | |
50 | (% style="text-align:center" %) | ||
51 | [[image:DeviceConfiguration.png]] | ||
52 | |||
![]() |
2.2 | 53 | == Connect method == |
54 | |||
55 | * USB direct connection | ||
56 | * Ethernet cable in LAN | ||
57 | |||
58 | (% style="text-align:center" %) | ||
59 | [[image:Scan Segment.png]] | ||
60 | |||
61 | * When the inputbox is not entered and directly click the magnifer icon, the current segment is scanned accroding to the PC IP's segment. | ||
62 | * When the inputbox is entered and click magnifer icon, the current segment is scanned according to the input IP. | ||
63 | |||
64 | == Configure network == | ||
65 | |||
66 | (% style="text-align:center" %) | ||
67 | [[image:Network Config.png]] | ||
68 | |||
![]() |
2.3 | 69 | * After V-Box is selected, configure the network for the current device |
70 | * Upload is for uploads the network configuration of the current devic | ||
71 | * ((( | ||
72 | After downloaded, the current device will connect to the corresponding server according to downloaded configuration | ||
73 | ))) | ||
74 | |||
![]() |
2.4 | 75 | == Test network == |
76 | |||
77 | Get the network status of the current device, see whether V-Box can ping server successfully. | ||
78 | |||
79 | == Flash light == | ||
80 | |||
81 | Let the lights of the V-Box start flashing quickly for several seconds, which is convenient for positioning where is the V-Box. | ||
82 | |||
83 | == Get machine code == | ||
84 | |||
85 | Get the machine code of the current connected device and copy it to the clipboard. | ||
86 | |||
87 | == Update time == | ||
88 | |||
89 | According to the current PC UTC time, to calibrate time of V-Box, but this would not change the time zone of V-Box. | ||
90 | |||
91 | == Clear == | ||
92 | |||
93 | Clear the operation log in the Operation reminder | ||
94 | |||
![]() |
14.1 | 95 | = Device Pass-through = |
![]() |
2.4 | 96 | |
![]() |
2.7 | 97 | == PLC Pass-through == |
![]() |
2.4 | 98 | |
![]() |
2.7 | 99 | (% style="text-align:center" %) |
100 | [[image:PLC Passthrough.png]] | ||
101 | |||
102 | **Functional overview** | ||
103 | |||
104 | {{info}} | ||
105 | Built on V-BOX/ig HMI and PLC on the basis of normal communication, online PLC connection according to the generated virtual serial port, allowing the PLC software communicate PLC, complete the upload/download PLC programs, monitoring PLC programs and other functions | ||
106 | {{/info}} | ||
107 | |||
![]() |
14.1 | 108 | === **Search** === |
![]() |
2.8 | 109 | |
![]() |
14.1 | 110 | Enter a device name/Machine code/Product code, device list only display the devices that meet the search criteria, and support real-time filtering**Device list** |
![]() |
2.8 | 111 | |
112 | (% style="text-align:center" %) | ||
113 | [[image:rightclick menu.png]] | ||
114 | |||
115 | * Display all groupings and device names and device status under current account. | ||
116 | * When the mouse is in the device list, right-click the menu to refresh the device list and copy the machine code/Product code. | ||
117 | * Refresh list: Reacquire all groupings and devices under the current account number from the server. | ||
118 | * ((( | ||
119 | Copy machine code: Copy the current device's machine code/Product code to the clipboard. | ||
120 | ))) | ||
121 | |||
![]() |
14.1 | 122 | === **Configuration template&Refresh status** === |
![]() |
2.9 | 123 | |
124 | * Refresh: Refresh the current device status(offline/online/being pass-through, etc.) | ||
125 | * New: Create a new configuration template according to current device and account | ||
126 | ** Name(required): Length limitation 1~~50, cannot duplicate | ||
127 | ** Port: Select which communication port of the device to pass-through | ||
128 | ** When the Ethernet is selected as pass-through communication port, the information user need to enter is IP address, need to conform IP address format, and port scopes from 1 to 65535 | ||
129 | ** When the device type is HMI, the template need to set a waiting timeout(ranges 0~~500) | ||
130 | * Edit: Modify the selected configuration template | ||
131 | * Delete: Delete the selected configuration template | ||
132 | |||
![]() |
14.1 | 133 | === **Device information&Configuration information** === |
![]() |
2.9 | 134 | |
135 | * Device information: Status (consistent with the status in the device list), machine code | ||
136 | * ((( | ||
137 | Configuration information: The configuration template list according to the selected device and current account. The specific information is displayed when different configurations are selected in the drop-down list | ||
138 | ))) | ||
139 | |||
![]() |
14.1 | 140 | === **Start pass-through/End pass-through** === |
![]() |
2.9 | 141 | |
142 | * Click Start pass-through to proceed PLC pass-through according to the current configuration template | ||
![]() |
2.11 | 143 | * Click End pass-through to end PLC pass-through connection |
![]() |
2.9 | 144 | * When the device is offline, the Start pass-through button cannot be clicked |
145 | * When the firmware version of device is too low, the Start pass-through button cannot be clicked | ||
146 | * The current account does not have the permission of pass-through to this device or the device is shared by others, the Start pass-through button cannot be clicked | ||
147 | * When the current account has a device being pass-through, the Start pass-through button cannot be clicked | ||
148 | * After clicking the Start pass-through button, if the pass-through is successful, the button changes to End pass-through, and the device status color on the left side list changes to blue | ||
149 | |||
![]() |
12.1 | 150 | == [[VPN Pass-through>>doc:V-BOX.V-Net.Manual.VPN passthrough.WebHome]] == |
![]() |
2.9 | 151 | |
![]() |
2.12 | 152 | == HMI Pass-through == |
153 | |||
154 | (% style="text-align:center" %) | ||
155 | [[image:HMI Passthrough.png]] | ||
156 | |||
157 | **Functional overview** | ||
158 | |||
159 | {{info}} | ||
160 | Select the download tool path in the installed PIStudio, pop up the download tool after successfully start pass-through , and select PC->HMI, and select the compiled .wmt or .wmt3 file, the program can be downloaded to the HMI. After the project downloaded, HMI will automatically restart. | ||
161 | {{/info}} | ||
162 | |||
![]() |
14.1 | 163 | === **Device list** === |
![]() |
2.12 | 164 | |
165 | * Display all support HMI devices under current account | ||
166 | * Right-click menu, search box is consistent with PLC pass-through | ||
167 | |||
![]() |
14.1 | 168 | === **HMI Download tool configuration** === |
![]() |
2.12 | 169 | |
170 | The folder where the selected download tool is located and the corresponding PIStudio version information | ||
![]() |
2.13 | 171 | |
![]() |
14.1 | 172 | === **Browse** === |
![]() |
2.13 | 173 | |
174 | Click Browse to find out if the selected folder containsPIStudioand download tools(Need to ensure existence) | ||
175 | |||
![]() |
14.1 | 176 | === **ReOpen** === |
![]() |
2.13 | 177 | |
178 | When click start pass-through, and the download tool is closed due to some situation after opened it, click ReOpen to open the download tool again | ||
179 | |||
![]() |
14.1 | 180 | === **HMI Download tool list** === |
![]() |
2.13 | 181 | |
![]() |
3.1 | 182 | * Automatically search and detect the installed PIStudio on this PC, and display all installed download tools and their versions when enter the HMI pass-through page |
183 | * Select any option in the table, download tool configuration area display the corresponding selected option's information, and saves the selected HMIdownload tool configuration at the same time | ||
![]() |
2.13 | 184 | |
![]() |
14.1 | 185 | === **Device information** === |
![]() |
3.1 | 186 | |
187 | Display device status and machine code | ||
188 | |||
![]() |
14.1 | 189 | === **Start pass-through/End pass-through** === |
![]() |
3.1 | 190 | |
191 | * Click Start pass-through, proceed pass-through according to the specified download tool and the selected device | ||
192 | * Click End pass-through to end HMI pass-through | ||
193 | * When the device is offline, the Start pass-through button cannot be clicked | ||
194 | * When the firmware version of the device is too low, the Start pass-through button cannot be clicked | ||
195 | * The current account does not have the permission of pass-through to this device or the device is shared by others, the Start pass-through button cannot be clicked | ||
196 | * When the current account has a device being pass-through, the Start pass-through button cannot be clicked | ||
197 | * After clicking the Start pass-through button, the pass-through is successful, the button changes to End pass-through, and the device status color on the left side changes to orange, and the selected download tool is opened at the same time | ||
198 | * ((( | ||
199 | The download tool is opened correctly: Machine code can be obtained and detected HMI firmware version | ||
200 | ))) | ||
201 | |||
202 | (% style="text-align:center" %) | ||
203 | [[image:Success passthrough download tool.png]] | ||
204 | |||
![]() |
14.1 | 205 | = Tools = |
![]() |
4.1 | 206 | |
207 | == ARP Scan == | ||
208 | |||
209 | (% style="text-align:center" %) | ||
210 | [[image:ARP scan.png]] | ||
211 | |||
212 | * Scan selectable network adapters | ||
213 | * Click the Scan button to scan all devices' IP address and the corresponding MAC address in the same network segment within the setting timeout | ||
214 | * ((( | ||
215 | The scanned device will be displayed on the list, which can help to judge whether the current device exists IP conflict problem or not | ||
216 | ))) | ||
217 | |||
218 | == OPC Tool == | ||
219 | |||
220 | (% style="text-align:center" %) | ||
221 | [[image:OPC tool.png]] | ||
222 | |||
223 | * The software is built-inOPCtool, no need to download additionally, about the specific operation of OPC tool, please refer to the [[OPC tool>>doc:V-BOX.V-Net.Manual.7 OPC tool.WebHome]] | ||
224 | * OPC tools can be found in the home menu bar->Tools->OPC tool | ||
225 | |||
![]() |
14.1 | 226 | = Configuration = |
![]() |
4.1 | 227 | |
228 | (% style="text-align:center" %) | ||
229 | [[image:Configuration.png]] | ||
230 | |||
231 | == Server Select == | ||
232 | |||
233 | Select the specified server, switch servers, and return to the login page | ||
234 | |||
235 | == Virtual Serial Port == | ||
236 | |||
237 | * Enable When using the PLC pass-through, need to use the virtual serial port function | ||
238 | * Select serial port: Choose the current idle serial port as the virtual serial port independently, so as to avoid access another new USB device conflict | ||
239 | |||
240 | == Firmware Update == | ||
241 | |||
![]() |
9.1 | 242 | Compare the firmware version carried by the software with the firmware version running by the device, if the firmware version of the V-NET Client software is higher than the firmware version of the device(V-Box), choose whether to upgrade the firmware of the device. |
![]() |
4.1 | 243 | |
244 | * Auto Update: Automatically detect whether the firmware version carried by the current V-NET Client software is the latest firmware on the server during the software running | ||
245 | * Manual Update: Need to click manually to compare the firmware version carried by the current V-NET Client software with the latest firmware version on the server | ||
246 | |||
![]() |
13.1 | 247 | == == |
![]() |
9.1 | 248 | |
![]() |
4.1 | 249 | == Cache Clear == |
250 | |||
251 | Click this button to restart the software and clear cef folder cache | ||
252 | |||
![]() |
14.1 | 253 | = Help = |
![]() |
4.1 | 254 | |
255 | (% style="text-align:center" %) | ||
256 | [[image:AboutUs.png]] | ||
257 | |||
258 | * Display software-related information | ||
259 | * Display APP and WeChat applet QR code | ||
260 | * Display company information |