Hunter 1.1 1 = 1 Login page =
2
3 (% style="text-align:center" %)
4 [[image:V-NET Login.png]]
5
6 == Language switch ==
7
8 Switch the display language of the software through the first drop-down list. Currently, there are two languages: Simplified Chinese, English.
9
10 == Server selection ==
11
12 Users can switch servers connected to on the software through the second drop-down list.
13
14 == User login ==
15
16 * Enter the correct account password to log in successfully
17 * If the same account is in differentPCLogin on the different device at the same time, the account logged on the first device will be forced to log off
18 * The view account does not have permission to use the device pass-through function on the home page
19
20 == Remember password ==
21
22 * If check this option, after entering the correct password and log in successfully, V-NET Client software would remember the password
23 * Users can select remembered account and password to log in directly through the inputbox drop-down list without repeatedly entering the password
24
25 == Offline mode ==
26
27 Users can jump directly to the homepage without entering the account password by clicking Offline-mode. Only some functions are worked in offline mode. Please refer to the corresponding function modules in the following specific contents.
28
Hunter 1.2 29 = 2 Offline mode =
30
31 (% style="text-align:center" %)
32 [[image:V-NET Offline.png]]
33
34 In offline mode, only some functions are available without login, like the above screenshot shows: The Display and Device Pass-through are disabled. To use the non-offline mode function, please close the V-NET Client, and restart to login account.
35
36 = 3 Display =
37
38 (% style="text-align:center" %)
39 [[image:V-NET homepage.png]]
40
Hunter 2.4 41 After logging into the software, jump to the V-NET homepage by default.
Hunter 1.2 42
43 (% style="text-align:center" %)
44 [[image:New layout.png]]
45
Hunter 2.4 46 The Pass-through tab is no longer displayed in the main interface. But integrated into the software "Device Pass-through" function. To use the corresponding function, please refer to following chapter"Device Pass-through".
Hunter 1.2 47
Hunter 1.3 48 = 4 Device Configuration =
49
50 (% style="text-align:center" %)
51 [[image:DeviceConfiguration.png]]
52
Hunter 2.2 53 == Connect method ==
54
55 * USB direct connection
56 * Ethernet cable in LAN
57
58 (% style="text-align:center" %)
59 [[image:Scan Segment.png]]
60
61 * When the inputbox is not entered and directly click the magnifer icon, the current segment is scanned accroding to the PC IP's segment.
62 * When the inputbox is entered and click magnifer icon, the current segment is scanned according to the input IP.
63
64 == Configure network ==
65
66 (% style="text-align:center" %)
67 [[image:Network Config.png]]
68
Hunter 2.3 69 * After V-Box is selected, configure the network for the current device
70 * Upload is for uploads the network configuration of the current devic
71 * (((
72 After downloaded, the current device will connect to the corresponding server according to downloaded configuration
73 )))
74
Hunter 2.4 75 == Test network ==
76
77 Get the network status of the current device, see whether V-Box can ping server successfully.
78
79 == Update Firmware ==
80
81 Compare the firmware version carried by the software with the firmware version running by the device, if the firmware version of the V-NET Client software is higher than the firmware version of the device(V-Box), choose whether to upgrade the firmware of the device.
82
83 == Flash light ==
84
85 Let the lights of the V-Box start flashing quickly for several seconds, which is convenient for positioning where is the V-Box.
86
87 == Get machine code ==
88
89 Get the machine code of the current connected device and copy it to the clipboard.
90
91 == Update time ==
92
93 According to the current PC UTC time, to calibrate time of V-Box, but this would not change the time zone of V-Box.
94
95 == Clear ==
96
97 Clear the operation log in the Operation reminder
98
Hunter 2.7 99 = 5 Device Pass-through =
Hunter 2.4 100
Hunter 2.7 101 == PLC Pass-through ==
Hunter 2.4 102
Hunter 2.7 103 (% style="text-align:center" %)
104 [[image:PLC Passthrough.png]]
105
106 **Functional overview**
107
108 {{info}}
109 Built on V-BOX/ig HMI and PLC on the basis of normal communication, online PLC connection according to the generated virtual serial port, allowing the PLC software communicate PLC, complete the upload/download PLC programs, monitoring PLC programs and other functions
110 {{/info}}