Wiki source code of 3 V-NET Client

Version 5.1 by Hunter on 2023/01/07 11:58

Show last authors
1 = 1 Login page =
2
3 (% style="text-align:center" %)
4 [[image:V-NET Login.png]]
5
6 == Language switch ==
7
8 Switch the display language of the software through the first drop-down list. Currently, there are two languages: Simplified Chinese, English.
9
10 == Server selection ==
11
12 Users can switch servers connected to on the software through the second drop-down list.
13
14 == User login ==
15
16 * Enter the correct account password to log in successfully
17 * If the same account is in differentPCLogin on the different device at the same time, the account logged on the first device will be forced to log off
18 * The view account does not have permission to use the device pass-through function on the home page
19
20 == Remember password ==
21
22 * If check this option, after entering the correct password and log in successfully, V-NET Client software would remember the password
23 * Users can select remembered account and password to log in directly through the inputbox drop-down list without repeatedly entering the password
24
25 == Offline mode ==
26
27 Users can jump directly to the homepage without entering the account password by clicking Offline-mode. Only some functions are worked in offline mode. Please refer to the corresponding function modules in the following specific contents.
28
29 = 2 Offline mode =
30
31 (% style="text-align:center" %)
32 [[image:V-NET Offline.png]]
33
34 In offline mode, only some functions are available without login, like the above screenshot shows: The Display and Device Pass-through are disabled. To use the non-offline mode function, please close the V-NET Client, and restart to login account.
35
36 = 3 Display =
37
38 (% style="text-align:center" %)
39 [[image:V-NET homepage.png]]
40
41 After logging into the software, jump to the V-NET homepage by default.
42
43 (% style="text-align:center" %)
44 [[image:New layout.png]]
45
46 The Pass-through tab is no longer displayed in the main interface. But integrated into the software "Device Pass-through" function. To use the corresponding function, please refer to following chapter [[Device Pass-through>>https://"Device Pass-through"]].
47
48 = 4 Device Configuration =
49
50 (% style="text-align:center" %)
51 [[image:DeviceConfiguration.png]]
52
53 == Connect method ==
54
55 * USB direct connection
56 * Ethernet cable in LAN
57
58 (% style="text-align:center" %)
59 [[image:Scan Segment.png]]
60
61 * When the inputbox is not entered and directly click the magnifer icon, the current segment is scanned accroding to the PC IP's segment.
62 * When the inputbox is entered and click magnifer icon, the current segment is scanned according to the input IP.
63
64 == Configure network ==
65
66 (% style="text-align:center" %)
67 [[image:Network Config.png]]
68
69 * After V-Box is selected, configure the network for the current device
70 * Upload is for uploads the network configuration of the current devic
71 * (((
72 After downloaded, the current device will connect to the corresponding server according to downloaded configuration
73 )))
74
75 == Test network ==
76
77 Get the network status of the current device, see whether V-Box can ping server successfully.
78
79 == Update Firmware ==
80
81 Compare the firmware version carried by the software with the firmware version running by the device, if the firmware version of the V-NET Client software is higher than the firmware version of the device(V-Box), choose whether to upgrade the firmware of the device.
82
83 == Flash light ==
84
85 Let the lights of the V-Box start flashing quickly for several seconds, which is convenient for positioning where is the V-Box.
86
87 == Get machine code ==
88
89 Get the machine code of the current connected device and copy it to the clipboard.
90
91 == Update time ==
92
93 According to the current PC UTC time, to calibrate time of V-Box, but this would not change the time zone of V-Box.
94
95 == Clear ==
96
97 Clear the operation log in the Operation reminder
98
99 = 5 Device Pass-through =
100
101 == PLC Pass-through ==
102
103 (% style="text-align:center" %)
104 [[image:PLC Passthrough.png]]
105
106 **Functional overview**
107
108 {{info}}
109 Built on V-BOX/ig HMI and PLC on the basis of normal communication, online PLC connection according to the generated virtual serial port, allowing the PLC software communicate PLC, complete the upload/download PLC programs, monitoring PLC programs and other functions
110 {{/info}}
111
112 === **1 Search** ===
113
114 Enter a device name/Machine code/Product code, device list only display the devices that meet the search criteria, and support real-time filtering
115
116 (% style="text-align:center" %)
117 [[image:PLC Passthrough Device list.png]]
118
119 === **2 Device list** ===
120
121 (% style="text-align:center" %)
122 [[image:rightclick menu.png]]
123
124 * Display all groupings and device names and device status under current account.
125 * When the mouse is in the device list, right-click the menu to refresh the device list and copy the machine code/Product code.
126 * Refresh list: Reacquire all groupings and devices under the current account number from the server.
127 * (((
128 Copy machine code: Copy the current device's machine code/Product code to the clipboard.
129 )))
130
131 === **3 Configuration template&Refresh status** ===
132
133 * Refresh: Refresh the current device status(offline/online/being pass-through, etc.)
134 * New: Create a new configuration template according to current device and account
135 ** Name(required): Length limitation 1~~50, cannot duplicate
136 ** Port: Select which communication port of the device to pass-through
137 ** When the Ethernet is selected as pass-through communication port, the information user need to enter is IP address, need to conform IP address format, and port scopes from 1 to 65535
138 ** When the device type is HMI, the template need to set a waiting timeout(ranges 0~~500)
139 * Edit: Modify the selected configuration template
140 * Delete: Delete the selected configuration template
141
142 === **4 Device information&Configuration information** ===
143
144 * Device information: Status (consistent with the status in the device list), machine code
145 * (((
146 Configuration information: The configuration template list according to the selected device and current account. The specific information is displayed when different configurations are selected in the drop-down list
147 )))
148
149 === **5 Start pass-through/End pass-through** ===
150
151 * Click Start pass-through to proceed PLC pass-through according to the current configuration template
152 * Click End pass-through to end PLC pass-through connection
153 * When the device is offline, the Start pass-through button cannot be clicked
154 * When the firmware version of device is too low, the Start pass-through button cannot be clicked
155 * The current account does not have the permission of pass-through to this device or the device is shared by others, the Start pass-through button cannot be clicked
156 * When the current account has a device being pass-through, the Start pass-through button cannot be clicked
157 * After clicking the Start pass-through button, if the pass-through is successful, the button changes to End pass-through, and the device status color on the left side list changes to blue
158
159 == VPN Pass-through ==
160
161 (% style="text-align:center" %)
162 [[image:VPN passthrough.png]]
163
164 **Functional overview**
165
166 {{info}}
167 VPN pass-through is to add PC to the Local Area Network where the device is located. It can be imagined that PC "replaces" the device at this time, and PC can access any PLC in this Local Area Network where the device is located.
168 {{/info}}
169
170 === **1 Device list** ===
171
172 * Display all support VPN pass-through devices under current account
173 * (((
174 Right-click menu, search box is consistent with PLC pass-through
175 )))
176
177 === **2 Remote LAN IP** ===
178
179 VPN pass-through required parameters, DHCP/Static IP of pass-through IP
180
181 === **3 Device information** ===
182
183 Display device machine code, name, device status and other information
184
185 === **4 Start pass-through/End pass-through** ===
186
187 * Click Start pass-through, proceed VPN pass-through according to the setting LAN pass-through IP
188 * Click End pass-through to end VPN pass-through
189 * When the device is offline, the Start pass-through button cannot be clicked
190 * When the firmware version of the device is too low, the Start pass-through button cannot be clicked
191 * The current account does not have the permission of pass-through to this device or the device is shared by others, the Start pass-through button cannot be clicked
192 * When the current account has a device being pass-through, the Start pass-through button cannot be clicked
193 * (((
194 After clicking the Start pass-through button, the pass-through is successful, the button changes to End pass-through, and the device status color on the left side changes to yellow
195 )))
196
197 == HMI Pass-through ==
198
199 (% style="text-align:center" %)
200 [[image:HMI Passthrough.png]]
201
202 **Functional overview**
203
204 {{info}}
205 Select the download tool path in the installed PIStudio, pop up the download tool after successfully start pass-through , and select PC->HMI, and select the compiled .wmt or .wmt3 file, the program can be downloaded to the HMI. After the project downloaded, HMI will automatically restart.
206 {{/info}}
207
208 === **1 Device list** ===
209
210 * Display all support HMI devices under current account
211 * Right-click menu, search box is consistent with PLC pass-through
212
213 === **2 HMI Download tool configuration** ===
214
215 The folder where the selected download tool is located and the corresponding PIStudio version information
216
217 === **3 Browse** ===
218
219 Click Browse to find out if the selected folder containsPIStudioand download tools(Need to ensure existence)
220
221 === **4 ReOpen** ===
222
223 When click start pass-through, and the download tool is closed due to some situation after opened it, click ReOpen to open the download tool again
224
225 === **5 HMI Download tool list** ===
226
227 * Automatically search and detect the installed PIStudio on this PC, and display all installed download tools and their versions when enter the HMI pass-through page
228 * Select any option in the table, download tool configuration area display the corresponding selected option's information, and saves the selected HMIdownload tool configuration at the same time
229
230 === **6 Device information** ===
231
232 Display device status and machine code
233
234 === **7 Start pass-through/End pass-through** ===
235
236 * Click Start pass-through, proceed pass-through according to the specified download tool and the selected device
237 * Click End pass-through to end HMI pass-through
238 * When the device is offline, the Start pass-through button cannot be clicked
239 * When the firmware version of the device is too low, the Start pass-through button cannot be clicked
240 * The current account does not have the permission of pass-through to this device or the device is shared by others, the Start pass-through button cannot be clicked
241 * When the current account has a device being pass-through, the Start pass-through button cannot be clicked
242 * After clicking the Start pass-through button, the pass-through is successful, the button changes to End pass-through, and the device status color on the left side changes to orange, and the selected download tool is opened at the same time
243 * (((
244 The download tool is opened correctly: Machine code can be obtained and detected HMI firmware version
245 )))
246
247 (% style="text-align:center" %)
248 [[image:Success passthrough download tool.png]]
249
250 = 6 Tools =
251
252 == ARP Scan ==
253
254 (% style="text-align:center" %)
255 [[image:ARP scan.png]]
256
257 * Scan selectable network adapters
258 * Click the Scan button to scan all devices' IP address and the corresponding MAC address in the same network segment within the setting timeout
259 * (((
260 The scanned device will be displayed on the list, which can help to judge whether the current device exists IP conflict problem or not
261 )))
262
263 == OPC Tool ==
264
265 (% style="text-align:center" %)
266 [[image:OPC tool.png]]
267
268 * The software is built-inOPCtool, no need to download additionally, about the specific operation of OPC tool, please refer to the [[OPC tool>>doc:V-BOX.V-Net.Manual.7 OPC tool.WebHome]]
269 * OPC tools can be found in the home menu bar->Tools->OPC tool
270
271 = 7 Configuration =
272
273 (% style="text-align:center" %)
274 [[image:Configuration.png]]
275
276 == Server Select ==
277
278 Select the specified server, switch servers, and return to the login page
279
280 == Virtual Serial Port ==
281
282 * Enable When using the PLC pass-through, need to use the virtual serial port function
283 * Select serial port: Choose the current idle serial port as the virtual serial port independently, so as to avoid access another new USB device conflict
284
285 == Firmware Update ==
286
287 Compare the firmware version carried by the current V-NET Client software with the latest firmware on the server. If not, choose to update the firmware version carried by the software
288
289 * Auto Update: Automatically detect whether the firmware version carried by the current V-NET Client software is the latest firmware on the server during the software running
290 * Manual Update: Need to click manually to compare the firmware version carried by the current V-NET Client software with the latest firmware version on the server
291
292 == Cache Clear ==
293
294 Click this button to restart the software and clear cef folder cache
295
296 = 8 Help =
297
298 (% style="text-align:center" %)
299 [[image:AboutUs.png]]
300
301 * Display software-related information
302 * Display APP and WeChat applet QR code
303 * Display company information