1.1 | 1 | = Login page = |
| 2 | |||
| 3 | (% style="text-align:center" %) | ||
| 4 | [[image:V-NET Login.png]] | ||
| 5 | |||
| 6 | == Language switch == | ||
| 7 | |||
| 8 | Switch the display language of the software through the first drop-down list. Currently, there are two languages: Simplified Chinese, English. | ||
| 9 | |||
| 10 | == Server selection == | ||
| 11 | |||
| 12 | Users can switch servers connected to on the software through the second drop-down list. | ||
| 13 | |||
| 14 | == User login == | ||
| 15 | |||
| 16 | * Enter the correct account password to log in successfully | ||
| 17 | * If the same account is in differentPCLogin on the different device at the same time, the account logged on the first device will be forced to log off | ||
| 18 | * The view account does not have permission to use the device pass-through function on the home page | ||
| 19 | |||
| 20 | == Remember password == | ||
| 21 | |||
| 22 | * If check this option, after entering the correct password and log in successfully, V-NET Client software would remember the password | ||
| 23 | * Users can select remembered account and password to log in directly through the inputbox drop-down list without repeatedly entering the password | ||
| 24 | |||
| 25 | == Offline mode == | ||
| 26 | |||
| 27 | Users can jump directly to the homepage without entering the account password by clicking Offline-mode. Only some functions are worked in offline mode. Please refer to the corresponding function modules in the following specific contents. | ||
| 28 | |||
| 29 | = Offline mode = | ||
| 30 | |||
| 31 | (% style="text-align:center" %) | ||
| 32 | [[image:V-NET Offline.png]] | ||
| 33 | |||
| 34 | In offline mode, only some functions are available without login, like the above screenshot shows: The Display and Device Pass-through are disabled. To use the non-offline mode function, please close the V-NET Client, and restart to login account. | ||
| 35 | |||
| 36 | = Display = | ||
| 37 | |||
| 38 | (% style="text-align:center" %) | ||
| 39 | [[image:V-NET homepage.png]] | ||
| 40 | |||
| 41 | After logging into the software, jump to the V-NET homepage by default. | ||
| 42 | |||
| 43 | (% style="text-align:center" %) | ||
| 44 | [[image:New layout.png]] | ||
| 45 | |||
| 46 | The Pass-through tab is no longer displayed in the main interface. But integrated into the software "Device Pass-through" function. To use the corresponding function, please refer to following chapter [[Device Pass-through>>https://docs.we-con.com.cn/bin/view/V-BOX/V-Net/Manual/VPN%20passthrough/]]. | ||
| 47 | |||
| 48 | = Device Configuration = | ||
| 49 | |||
| 50 | (% style="text-align:center" %) | ||
| 51 | [[image:DeviceConfiguration.png]] | ||
| 52 | |||
| 53 | == Connect method == | ||
| 54 | |||
| 55 | * USB direct connection | ||
| 56 | * Ethernet cable in LAN | ||
| 57 | |||
| 58 | (% style="text-align:center" %) | ||
| 59 | [[image:Scan Segment.png]] | ||
| 60 | |||
| 61 | * When the inputbox is not entered and directly click the magnifer icon, the current segment is scanned accroding to the PC IP's segment. | ||
| 62 | * When the inputbox is entered and click magnifer icon, the current segment is scanned according to the input IP. | ||
| 63 | |||
| 64 | == Configure network == | ||
| 65 | |||
| 66 | (% style="text-align:center" %) | ||
| 67 | [[image:Network Config.png]] | ||
| 68 | |||
| 69 | * After V-Box is selected, configure the network for the current device | ||
| 70 | * Upload is for uploads the network configuration of the current devic | ||
| 71 | * ((( | ||
| 72 | After downloaded, the current device will connect to the corresponding server according to downloaded configuration | ||
| 73 | ))) | ||
| 74 | |||
| 75 | == Test network == | ||
| 76 | |||
| 77 | Get the network status of the current device, see whether V-Box can ping server successfully. | ||
| 78 | |||
| 79 | == Flash light == | ||
| 80 | |||
| 81 | Let the lights of the V-Box start flashing quickly for several seconds, which is convenient for positioning where is the V-Box. | ||
| 82 | |||
| 83 | == Get machine code == | ||
| 84 | |||
| 85 | Get the machine code of the current connected device and copy it to the clipboard. | ||
| 86 | |||
| 87 | == Update time == | ||
| 88 | |||
| 89 | According to the current PC UTC time, to calibrate time of V-Box, but this would not change the time zone of V-Box. | ||
| 90 | |||
| 91 | == Clear == | ||
| 92 | |||
| 93 | Clear the operation log in the Operation reminder | ||
| 94 | |||
| 95 | = Device Pass-through = | ||
| 96 | |||
| 97 | == PLC Pass-through == | ||
| 98 | |||
| 99 | (% style="text-align:center" %) | ||
| 100 | [[image:PLC Passthrough.png]] | ||
| 101 | |||
| 102 | **Functional overview** | ||
| 103 | |||
| 104 | {{info}} | ||
| 105 | Built on V-BOX/ig HMI and PLC on the basis of normal communication, online PLC connection according to the generated virtual serial port, allowing the PLC software communicate PLC, complete the upload/download PLC programs, monitoring PLC programs and other functions | ||
| 106 | {{/info}} | ||
| 107 | |||
| 108 | === **Search** === | ||
| 109 | |||
| 110 | Enter a device name/Machine code/Product code, device list only display the devices that meet the search criteria, and support real-time filtering**Device list** | ||
| 111 | |||
| 112 | (% style="text-align:center" %) | ||
| 113 | [[image:rightclick menu.png]] | ||
| 114 | |||
| 115 | * Display all groupings and device names and device status under current account. | ||
| 116 | * When the mouse is in the device list, right-click the menu to refresh the device list and copy the machine code/Product code. | ||
| 117 | * Refresh list: Reacquire all groupings and devices under the current account number from the server. | ||
| 118 | * ((( | ||
| 119 | Copy machine code: Copy the current device's machine code/Product code to the clipboard. | ||
| 120 | ))) | ||
| 121 | |||
| 122 | === **Configuration template&Refresh status** === | ||
| 123 | |||
| 124 | * Refresh: Refresh the current device status(offline/online/being pass-through, etc.) | ||
| 125 | * New: Create a new configuration template according to current device and account | ||
| 126 | ** Name(required): Length limitation 1~~50, cannot duplicate | ||
| 127 | ** Port: Select which communication port of the device to pass-through | ||
| 128 | ** When the Ethernet is selected as pass-through communication port, the information user need to enter is IP address, need to conform IP address format, and port scopes from 1 to 65535 | ||
| 129 | ** When the device type is HMI, the template need to set a waiting timeout(ranges 0~~500) | ||
| 130 | * Edit: Modify the selected configuration template | ||
| 131 | * Delete: Delete the selected configuration template | ||
| 132 | |||
| 133 | === **Device information&Configuration information** === | ||
| 134 | |||
| 135 | * Device information: Status (consistent with the status in the device list), machine code | ||
| 136 | * ((( | ||
| 137 | Configuration information: The configuration template list according to the selected device and current account. The specific information is displayed when different configurations are selected in the drop-down list | ||
| 138 | ))) | ||
| 139 | |||
| 140 | === **Start pass-through/End pass-through** === | ||
| 141 | |||
| 142 | * Click Start pass-through to proceed PLC pass-through according to the current configuration template | ||
| 143 | * Click End pass-through to end PLC pass-through connection | ||
| 144 | * When the device is offline, the Start pass-through button cannot be clicked | ||
| 145 | * When the firmware version of device is too low, the Start pass-through button cannot be clicked | ||
| 146 | * The current account does not have the permission of pass-through to this device or the device is shared by others, the Start pass-through button cannot be clicked | ||
| 147 | * When the current account has a device being pass-through, the Start pass-through button cannot be clicked | ||
| 148 | * After clicking the Start pass-through button, if the pass-through is successful, the button changes to End pass-through, and the device status color on the left side list changes to blue | ||
| 149 | |||
| 150 | == [[VPN Pass-through>>doc:V-BOX.V-Net.Manual.VPN passthrough.WebHome]] == | ||
| 151 | |||
| 152 | == HMI Pass-through == | ||
| 153 | |||
| 154 | (% style="text-align:center" %) | ||
| 155 | [[image:HMI Passthrough.png]] | ||
| 156 | |||
| 157 | **Functional overview** | ||
| 158 | |||
| 159 | {{info}} | ||
| 160 | Select the download tool path in the installed PIStudio, pop up the download tool after successfully start pass-through , and select PC->HMI, and select the compiled .wmt or .wmt3 file, the program can be downloaded to the HMI. After the project downloaded, HMI will automatically restart. | ||
| 161 | {{/info}} | ||
| 162 | |||
| 163 | === **Device list** === | ||
| 164 | |||
| 165 | * Display all support HMI devices under current account | ||
| 166 | * Right-click menu, search box is consistent with PLC pass-through | ||
| 167 | |||
| 168 | === **HMI Download tool configuration** === | ||
| 169 | |||
| 170 | The folder where the selected download tool is located and the corresponding PIStudio version information | ||
| 171 | |||
| 172 | === **Browse** === | ||
| 173 | |||
| 174 | Click Browse to find out if the selected folder containsPIStudioand download tools(Need to ensure existence) | ||
| 175 | |||
| 176 | === **ReOpen** === | ||
| 177 | |||
| 178 | When click start pass-through, and the download tool is closed due to some situation after opened it, click ReOpen to open the download tool again | ||
| 179 | |||
| 180 | === **HMI Download tool list** === | ||
| 181 | |||
| 182 | * Automatically search and detect the installed PIStudio on this PC, and display all installed download tools and their versions when enter the HMI pass-through page | ||
| 183 | * Select any option in the table, download tool configuration area display the corresponding selected option's information, and saves the selected HMIdownload tool configuration at the same time | ||
| 184 | |||
| 185 | === **Device information** === | ||
| 186 | |||
| 187 | Display device status and machine code | ||
| 188 | |||
| 189 | === **Start pass-through/End pass-through** === | ||
| 190 | |||
| 191 | * Click Start pass-through, proceed pass-through according to the specified download tool and the selected device | ||
| 192 | * Click End pass-through to end HMI pass-through | ||
| 193 | * When the device is offline, the Start pass-through button cannot be clicked | ||
| 194 | * When the firmware version of the device is too low, the Start pass-through button cannot be clicked | ||
| 195 | * The current account does not have the permission of pass-through to this device or the device is shared by others, the Start pass-through button cannot be clicked | ||
| 196 | * When the current account has a device being pass-through, the Start pass-through button cannot be clicked | ||
| 197 | * After clicking the Start pass-through button, the pass-through is successful, the button changes to End pass-through, and the device status color on the left side changes to orange, and the selected download tool is opened at the same time | ||
| 198 | * ((( | ||
| 199 | The download tool is opened correctly: Machine code can be obtained and detected HMI firmware version | ||
| 200 | ))) | ||
| 201 | |||
| 202 | (% style="text-align:center" %) | ||
| 203 | [[image:Success passthrough download tool.png]] | ||
| 204 | |||
| 205 | = Tools = | ||
| 206 | |||
| 207 | == ARP Scan == | ||
| 208 | |||
| 209 | === [[The video for getting V-box ip>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Video/Scan%20box%20ip.mp4]] === | ||
| 210 | |||
| 211 | (% style="text-align:center" %) | ||
| 212 | [[image:ARP scan.png]] | ||
| 213 | |||
| 214 | * Scan selectable network adapters | ||
| 215 | * Click the Scan button to scan all devices' IP address and the corresponding MAC address in the same network segment within the setting timeout | ||
| 216 | * ((( | ||
| 217 | The scanned device will be displayed on the list, which can help to judge whether the current device exists IP conflict problem or not | ||
| 218 | ))) | ||
| 219 | |||
| 220 | (% class="box infomessage" %) | ||
| 221 | ((( | ||
| 222 | Note: If V-box IP can not be scanned by ARP Scan. Please download the following software, IPScan. Its operation is the same as ARP Scan. | ||
| 223 | ))) | ||
| 224 | |||
| 225 | === [[IPScan>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Software/IPScan.exe]] === | ||
| 226 | |||
| 227 | == OPC Tool == | ||
| 228 | |||
| 229 | (% style="text-align:center" %) | ||
| 230 | [[image:OPC tool.png]] | ||
| 231 | |||
| 232 | * The software is built-inOPCtool, no need to download additionally, about the specific operation of OPC tool, please refer to the [[OPC tool>>doc:V-BOX.V-Net.Manual.7 OPC tool.WebHome]] | ||
| 233 | * OPC tools can be found in the home menu bar->Tools->OPC tool | ||
| 234 | |||
| 235 | = Configuration = | ||
| 236 | |||
| 237 | (% style="text-align:center" %) | ||
| 238 | [[image:Configuration.png]] | ||
| 239 | |||
| 240 | == Server Select == | ||
| 241 | |||
| 242 | Select the specified server, switch servers, and return to the login page | ||
| 243 | |||
| 244 | == Virtual Serial Port == | ||
| 245 | |||
| 246 | * Enable When using the PLC pass-through, need to use the virtual serial port function | ||
| 247 | * Select serial port: Choose the current idle serial port as the virtual serial port independently, so as to avoid access another new USB device conflict | ||
| 248 | |||
| 249 | == [[Firmware Update>>https://docs.we-con.com.cn/bin/view/V-BOX/V-Net/Manual/3%20V-NET%20Client/3.3%20Firmware%20upgrade/]] == | ||
| 250 | |||
| 251 | == Cache Clear == | ||
| 252 | |||
| 253 | Click this button to restart the software and clear cef folder cache | ||
| 254 | |||
| 255 | = Help = | ||
| 256 | |||
| 257 | (% style="text-align:center" %) | ||
| 258 | [[image:AboutUs.png]] | ||