Changes for page 05 Cloud SCADA
Last modified by Joe on 2024/08/08 09:29
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -7213,304 +7213,6 @@ 7213 7213 |(% colspan="2" %)Display|Set object position and size 7214 7214 ))) 7215 7215 7216 -== Common object == 7217 - 7218 -(% style="text-align:center" %) 7219 -[[image:V-BOX cloud configuration user manual_html_c84a5d0032df07e2.png||height="420" width="250" class="img-thumbnail"]] 7220 - 7221 -=== Display frame === 7222 - 7223 -After binding the monitoring point, the data of the monitoring point can be displayed in real time. 7224 - 7225 -|=**Item**|=**Description** 7226 -|Monitoring Point|Set operating address for this object (Read and write can be different); 7227 -|Read-write permission|There are three modes for it, users could select according to requirements; 7228 -|Set Text|It is used for setting style of text and display direction 7229 -|Style|It is used for setting object display, like background color; 7230 -|Expansion|It is used for setting expansion function, like lock position; 7231 -|Display|It is used for setting object position and size 7232 - 7233 -* **Bit /Word Indicator** 7234 - 7235 -Indicator could monitor and display the specified PLC or HMI bit address, and its state changes according to the specified address value. 7236 - 7237 -((( 7238 -|**Items**|**Description** 7239 -|Monitor Point|Set reading address for this object; 7240 -|Status|Set text for every status; 7241 -|Picture|Set picture for every status; 7242 -|Expansion|Set display expansion function, such as blink 7243 -|Display|Set object position and size 7244 -))) 7245 - 7246 -* **Bit/ Word Switch** 7247 - 7248 -Switch could operate the specified PLC or HMI bit address, and its state changes according to the specified address value. 7249 - 7250 -((( 7251 -|**Items**|**Description** 7252 -|Monitor Point|Set operating address for this object (Read and write can be different); 7253 -|Read-write permission|There are three modes for it, users could select according to requirements; 7254 -|Pop up a confirmation box|Check it to enable confirmation box for operating; 7255 -|Status|Set text for every status; 7256 -|Picture|Set picture for every status; 7257 -|Expansion|Set display expansion function, such as blink 7258 -|Display|Set object position and size 7259 -))) 7260 - 7261 -* **Dashboard** 7262 - 7263 -Display the value of address in real time using the dashboard. 7264 - 7265 -((( 7266 -|**Items**|**Description** 7267 -|Monitor Point|Set operating address for this object (Read and write can be different); 7268 -|Select|Set dashboard display range, there are two modes, Constant and Variable 7269 -|Scale value|Check it to display value; 7270 -|Select Language|Set text for object; 7271 -|Style|Set object display style such as color, scales number; 7272 -|Alarm Zone|Set range and color for alarm 7273 -|Display|Set object position and size 7274 -))) 7275 - 7276 -* **Bar graph** 7277 - 7278 -Use the length or height of the rectangle to reflect the value of reading address so that the value could be visualized. 7279 - 7280 -((( 7281 -|**Items**|**Description** 7282 -|Monitor Point|Set operating address for this object (Read and write can be different); 7283 -|Digit Display|Check it to display digit value on bar; 7284 -|Progress bar direction|Select display direction; 7285 -|Scales|Set object scales display type and color; 7286 -|Bar color|Set color for bar; 7287 -|Background Display|Set color of bar background; 7288 -|Alarm Zone|Set range and color for alarm 7289 -|Display|Set object position and size 7290 -))) 7291 - 7292 -* **Real-Time Trend Chart** 7293 - 7294 -Use the curve to show the trend of the data over time. X-axis is time, Y-axis is variable. 7295 - 7296 -((( 7297 -|**Items**|**Description** 7298 -|Monitor Point|Set operating address for this object (Read and write can be different); 7299 -|Digit Display|Check it to display digit value on bar; 7300 -|Progress bar direction|Select display direction; 7301 -|Scales|Set object scales display type and color; 7302 -|Bar color|Set color for bar; 7303 -|Background Display|Set color of bar background; 7304 -|Alarm Zone|Set range and color for alarm 7305 -|Display|Set object position and size 7306 -| | 7307 -))) 7308 - 7309 -* **Flow pipe** 7310 - 7311 -This is a flowing animation object, users could set animation trigger condition for it, the monitor point could be both bit address and word address; 7312 - 7313 -((( 7314 -|**Items**|**Description** 7315 -|Border color|Set object background color; 7316 -|Color|Set flowing block color; 7317 -|Speed|Three modes for flowing block speed; 7318 -|Flow direction|Two modes for flowing direction; 7319 -|Monitor Point|Set trigger address; 7320 -|Trigger Condition|((( 7321 -Bit address: Select ON or OFF; 7322 - 7323 -Word address: Set value range; 7324 -))) 7325 -|Color Block Width|Set flowing block size; 7326 -|Color Block Length|Set flowing block size; 7327 -|Color Block Spacing|Set the spacing between flow blocks; 7328 -|Display Border|Select display or hide border; 7329 -|Alarm Zone|Set range and color for alarm 7330 -|Display|Set object position and size 7331 -))) 7332 - 7333 -**Tips for designing flow bar** 7334 - 7335 -When user need to simulate the flow of water in a pipe, please put the pipe picture at first, then hide the flow border and place it onto the pipe picture. 7336 - 7337 -* **Video object** 7338 - 7339 -Video object is used for playing the video file provided in the video source. 7340 - 7341 -((( 7342 -|**Items**|**Description** 7343 -|Border color|Set object background color; 7344 -|Color|Set flowing block color; 7345 -|Speed|Three modes for flowing block speed; 7346 -|Flow direction|Two modes for flowing direction; 7347 -|Monitor Point|Set trigger address; 7348 -|Trigger Condition|((( 7349 -Bit address: Select ON or OFF; 7350 - 7351 -Word address: Set value range; 7352 -))) 7353 -|Color Block Width|Set flowing block size; 7354 -|Color Block Length|Set flowing block size; 7355 -|Color Block Spacing|Set the spacing between flow blocks; 7356 -|Display Border|Select display or hide border; 7357 -|Alarm Zone|Set range and color for alarm 7358 -|Display|Set object position and size 7359 -))) 7360 - 7361 -* **Hyperlink** 7362 - 7363 -The object for link website; 7364 - 7365 -((( 7366 -|=**Items**|=**Description** 7367 -|Link address|Enter website; 7368 -|Open with|There are two options, user could select open with new window or current window; 7369 -|Select Language|One object could support three language, user could enter text for note object; 7370 -|Style|Set object display style such as color, use picture as background or not 7371 -|Display|Set object position and size 7372 -))) 7373 - 7374 -* **Function Switch** 7375 - 7376 -Function switch is designed to switch screens, and call and close sub screen. 7377 - 7378 -((( 7379 -|=**Items**|=**Description** 7380 -|Screen|Select the target screen for switch; 7381 -|Sub-screen|There are two options, user could select open with new window or current window; 7382 -|Previous|Switch to the previous screen 7383 -|Next|Switch to the next screen 7384 -|Return|Return to the screen before switch 7385 -|Text|Set text for object, including text font, color direction and so on; 7386 -|Style|Set object display style such as color, use picture as background or not 7387 -|Display|Set object position and size 7388 -))) 7389 - 7390 -* **Combination Switch** 7391 - 7392 -The combination switch supports the collection of multiple functions onto one object. When the object is pressed, multiple functions are arranged in sequence to meet the special requirements of user. 7393 - 7394 -((( 7395 -|=**Items**|=**Description** 7396 -|Bit operation|It provides [Bit copy], [Set ON], [Set OFF], [Switch] and [Bit Copy] functions. 7397 -|Word operation|It provides [Word copy], [Word set], [Increase] and [Decrease] functions, 7398 -|Arithmetic|[Add], [Subtract], [Multiply] and [Divide] functions 7399 -|Screen change|It provides screen switch function as [Function Switch], it supports [Previous], [Next], [Return], [Change to], and open, close sub-screen operations 7400 -|Delete|Delete selected item function; 7401 -|Empty|Delete all items in operation list; 7402 -|Up|Move the selected item up one row in operation list; 7403 -|Down|Move the selected item down one row in operation list; 7404 -))) 7405 - 7406 -**Time** 7407 - 7408 -It is used for displaying the time of the V-BOX, when the V-BOX is offline, the time will stay at the time when it is offline. 7409 - 7410 -((( 7411 -|=**Items**|=**Description** 7412 -|Monitoring box|Link a box for the time part 7413 -|Pattern|Two types, one is digit and the other is clock 7414 -|Format settings|Set format for time and date in digit pattern 7415 -|Background|Set display or hide background of object 7416 -|Set text|Set text display style; 7417 -|Display|Set object position and size 7418 -))) 7419 - 7420 -**Histogram** 7421 - 7422 -It is used for display more than one tag value in Bar graph format. 7423 - 7424 -((( 7425 -|=**Items**|=**Description** 7426 -|Add new group|Maximum is 8, add items for this object, also set colors 7427 -|Add monitoring point|Set read tag for every item, 7428 -|Style|Set object display style such as color, use picture as background or not 7429 -|Display|Set object position and size 7430 -))) 7431 - 7432 -**Alarm record display** 7433 - 7434 -It is used for display alarm information of V-BOX. It can support current and history alarm. 7435 - 7436 -((( 7437 -|=**Items**|=**Description** 7438 -|Select box|Link to V-BOX 7439 -|Alarm type|Select current alarm or history alarm or all 7440 -|Start date|Alarm display start date 7441 -|End date|Alarm display end date 7442 -|Format|Set display format for date and time 7443 -|Sequence|It provides two type, one is order, and the other is reverse order 7444 -|Display content|Users could select display contents by check them 7445 -|Style|Set colors for different parts 7446 -|Display|Set object position and size 7447 -))) 7448 - 7449 -**History trend chart** 7450 - 7451 -The history trend will display data record with graph. X axis represents as time, and Y axis represents as data. 7452 - 7453 -((( 7454 -|=(% colspan="2" %)**Items**|=**Description** 7455 -|(% colspan="2" %)Basic|Set numbers of curve in object and select style for every curves including color, link tag 7456 -|(% rowspan="11" %)Style|Display form|Two type, one is curve, and the other is table 7457 -|Start date|Start date of history data 7458 -|End date|End date of history data 7459 -|Format|Time and date format for display 7460 -|Sequence|Two types, order or reverse order 7461 -|Y range|Two types, fixed and adaptive 7462 -|Set text|Set font size, color and other styles. 7463 -|Transparency|Set transparency of object 7464 -|Background color|Two types, translucent or transparent 7465 -|Gradient way|Set display way and color 7466 -|Display bar|Check it to display screen bar 7467 -|(% colspan="2" %)Display|Set object position and size 7468 -))) 7469 - 7470 -**Indirect screen display** 7471 - 7472 -This object is used for calling screens when condition is met. 7473 - 7474 -((( 7475 -|=(% colspan="2" %)**Items**|=**Description** 7476 -|(% rowspan="4" %)Basic|Conditional trigger|It provides bit, word condition and unconditional 7477 -|Bind monitoring point|Link to tag for triggering 7478 -|Trigger condition|for bit address, it requires ON or OFF, for word address, different value corresponds to different screens. 7479 -|Designated screen|Only for bit address as trigger. When condition is met, display this screen 7480 -|(% colspan="2" %)Style|Set object display style such as display title bar or display or hide background 7481 -|(% colspan="2" %)Display|Set object position and size 7482 -))) 7483 - 7484 -**Ring chart** 7485 - 7486 -Display value as ring chart 7487 - 7488 -((( 7489 -|=(% colspan="2" %)**Items**|=**Description** 7490 -|(% rowspan="7" %)Basic|Monitor point|Link to tag for data reading 7491 -|Range|Set fixed range or variable range 7492 -|Scales|Set scales such as major and minor numbers, colors and so on 7493 -|Designated screen|Only for bit address as trigger. When condition is met, display this screen 7494 -|Numerical scale display|Check it to display scale 7495 -|Start angle|Set start angle for scale 7496 -|Color|Color setting for bar and background 7497 -|(% colspan="2" %)Alarm Zone|Set alarm range and colors 7498 -|(% colspan="2" %)Display|Set object position and size 7499 -))) 7500 - 7501 -**Pie chart** 7502 - 7503 -Display more than one value in one pie chart 7504 - 7505 -((( 7506 -|=(% colspan="2" %)**Items**|=**Description** 7507 -|(% colspan="2" %)Monitor point|Add read addresses, the maximum is 8 7508 -|(% rowspan="3" %)Style|Pattern|Set alarm range and colors 7509 -|Numerical scale|Check it to display value in object 7510 -|Monitoring name display|Check it to display name in object 7511 -|(% colspan="2" %)Display|Set object position and size 7512 -))) 7513 - 7514 7514 == **6.5 Tool bar** == 7515 7515 7516 7516 The toolbar has the same function as the tool list. (right-click on the canvas to pop up tool list)