Changes for page 05 Cloud SCADA
Last modified by Joe on 2024/08/08 09:29
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -16749,6 +16749,1794 @@ 16749 16749 |(% colspan="2" %)Display|Set object position and size 16750 16750 ))) 16751 16751 16752 +== Common object == 16753 + 16754 +(% style="text-align:center" %) 16755 +[[image:V-BOX cloud configuration user manual_html_c84a5d0032df07e2.png||height="420" width="250" class="img-thumbnail"]] 16756 + 16757 +=== Display frame === 16758 + 16759 +After binding the monitoring point, the data of the monitoring point can be displayed in real time. 16760 + 16761 +|=**Item**|=**Description** 16762 +|Monitoring Point|Set operating address for this object (Read and write can be different); 16763 +|Read-write permission|There are three modes for it, users could select according to requirements; 16764 +|Set Text|It is used for setting style of text and display direction 16765 +|Style|It is used for setting object display, like background color; 16766 +|Expansion|It is used for setting expansion function, like lock position; 16767 +|Display|It is used for setting object position and size 16768 + 16769 +* **Bit /Word Indicator** 16770 + 16771 +Indicator could monitor and display the specified PLC or HMI bit address, and its state changes according to the specified address value. 16772 + 16773 +((( 16774 +|**Items**|**Description** 16775 +|Monitor Point|Set reading address for this object; 16776 +|Status|Set text for every status; 16777 +|Picture|Set picture for every status; 16778 +|Expansion|Set display expansion function, such as blink 16779 +|Display|Set object position and size 16780 +))) 16781 + 16782 +* **Bit/ Word Switch** 16783 + 16784 +Switch could operate the specified PLC or HMI bit address, and its state changes according to the specified address value. 16785 + 16786 +((( 16787 +|**Items**|**Description** 16788 +|Monitor Point|Set operating address for this object (Read and write can be different); 16789 +|Read-write permission|There are three modes for it, users could select according to requirements; 16790 +|Pop up a confirmation box|Check it to enable confirmation box for operating; 16791 +|Status|Set text for every status; 16792 +|Picture|Set picture for every status; 16793 +|Expansion|Set display expansion function, such as blink 16794 +|Display|Set object position and size 16795 +))) 16796 + 16797 +* **Dashboard** 16798 + 16799 +Display the value of address in real time using the dashboard. 16800 + 16801 +((( 16802 +|**Items**|**Description** 16803 +|Monitor Point|Set operating address for this object (Read and write can be different); 16804 +|Select|Set dashboard display range, there are two modes, Constant and Variable 16805 +|Scale value|Check it to display value; 16806 +|Select Language|Set text for object; 16807 +|Style|Set object display style such as color, scales number; 16808 +|Alarm Zone|Set range and color for alarm 16809 +|Display|Set object position and size 16810 +))) 16811 + 16812 +* **Bar graph** 16813 + 16814 +Use the length or height of the rectangle to reflect the value of reading address so that the value could be visualized. 16815 + 16816 +((( 16817 +|**Items**|**Description** 16818 +|Monitor Point|Set operating address for this object (Read and write can be different); 16819 +|Digit Display|Check it to display digit value on bar; 16820 +|Progress bar direction|Select display direction; 16821 +|Scales|Set object scales display type and color; 16822 +|Bar color|Set color for bar; 16823 +|Background Display|Set color of bar background; 16824 +|Alarm Zone|Set range and color for alarm 16825 +|Display|Set object position and size 16826 +))) 16827 + 16828 +* **Real-Time Trend Chart** 16829 + 16830 +Use the curve to show the trend of the data over time. X-axis is time, Y-axis is variable. 16831 + 16832 +((( 16833 +|**Items**|**Description** 16834 +|Monitor Point|Set operating address for this object (Read and write can be different); 16835 +|Digit Display|Check it to display digit value on bar; 16836 +|Progress bar direction|Select display direction; 16837 +|Scales|Set object scales display type and color; 16838 +|Bar color|Set color for bar; 16839 +|Background Display|Set color of bar background; 16840 +|Alarm Zone|Set range and color for alarm 16841 +|Display|Set object position and size 16842 +| | 16843 +))) 16844 + 16845 +* **Flow pipe** 16846 + 16847 +This is a flowing animation object, users could set animation trigger condition for it, the monitor point could be both bit address and word address; 16848 + 16849 +((( 16850 +|**Items**|**Description** 16851 +|Border color|Set object background color; 16852 +|Color|Set flowing block color; 16853 +|Speed|Three modes for flowing block speed; 16854 +|Flow direction|Two modes for flowing direction; 16855 +|Monitor Point|Set trigger address; 16856 +|Trigger Condition|((( 16857 +Bit address: Select ON or OFF; 16858 + 16859 +Word address: Set value range; 16860 +))) 16861 +|Color Block Width|Set flowing block size; 16862 +|Color Block Length|Set flowing block size; 16863 +|Color Block Spacing|Set the spacing between flow blocks; 16864 +|Display Border|Select display or hide border; 16865 +|Alarm Zone|Set range and color for alarm 16866 +|Display|Set object position and size 16867 +))) 16868 + 16869 +**Tips for designing flow bar** 16870 + 16871 +When user need to simulate the flow of water in a pipe, please put the pipe picture at first, then hide the flow border and place it onto the pipe picture. 16872 + 16873 +* **Video object** 16874 + 16875 +Video object is used for playing the video file provided in the video source. 16876 + 16877 +((( 16878 +|**Items**|**Description** 16879 +|Border color|Set object background color; 16880 +|Color|Set flowing block color; 16881 +|Speed|Three modes for flowing block speed; 16882 +|Flow direction|Two modes for flowing direction; 16883 +|Monitor Point|Set trigger address; 16884 +|Trigger Condition|((( 16885 +Bit address: Select ON or OFF; 16886 + 16887 +Word address: Set value range; 16888 +))) 16889 +|Color Block Width|Set flowing block size; 16890 +|Color Block Length|Set flowing block size; 16891 +|Color Block Spacing|Set the spacing between flow blocks; 16892 +|Display Border|Select display or hide border; 16893 +|Alarm Zone|Set range and color for alarm 16894 +|Display|Set object position and size 16895 +))) 16896 + 16897 +* **Hyperlink** 16898 + 16899 +The object for link website; 16900 + 16901 +((( 16902 +|=**Items**|=**Description** 16903 +|Link address|Enter website; 16904 +|Open with|There are two options, user could select open with new window or current window; 16905 +|Select Language|One object could support three language, user could enter text for note object; 16906 +|Style|Set object display style such as color, use picture as background or not 16907 +|Display|Set object position and size 16908 +))) 16909 + 16910 +* **Function Switch** 16911 + 16912 +Function switch is designed to switch screens, and call and close sub screen. 16913 + 16914 +((( 16915 +|=**Items**|=**Description** 16916 +|Screen|Select the target screen for switch; 16917 +|Sub-screen|There are two options, user could select open with new window or current window; 16918 +|Previous|Switch to the previous screen 16919 +|Next|Switch to the next screen 16920 +|Return|Return to the screen before switch 16921 +|Text|Set text for object, including text font, color direction and so on; 16922 +|Style|Set object display style such as color, use picture as background or not 16923 +|Display|Set object position and size 16924 +))) 16925 + 16926 +* **Combination Switch** 16927 + 16928 +The combination switch supports the collection of multiple functions onto one object. When the object is pressed, multiple functions are arranged in sequence to meet the special requirements of user. 16929 + 16930 +((( 16931 +|=**Items**|=**Description** 16932 +|Bit operation|It provides [Bit copy], [Set ON], [Set OFF], [Switch] and [Bit Copy] functions. 16933 +|Word operation|It provides [Word copy], [Word set], [Increase] and [Decrease] functions, 16934 +|Arithmetic|[Add], [Subtract], [Multiply] and [Divide] functions 16935 +|Screen change|It provides screen switch function as [Function Switch], it supports [Previous], [Next], [Return], [Change to], and open, close sub-screen operations 16936 +|Delete|Delete selected item function; 16937 +|Empty|Delete all items in operation list; 16938 +|Up|Move the selected item up one row in operation list; 16939 +|Down|Move the selected item down one row in operation list; 16940 +))) 16941 + 16942 +**Time** 16943 + 16944 +It is used for displaying the time of the V-BOX, when the V-BOX is offline, the time will stay at the time when it is offline. 16945 + 16946 +((( 16947 +|=**Items**|=**Description** 16948 +|Monitoring box|Link a box for the time part 16949 +|Pattern|Two types, one is digit and the other is clock 16950 +|Format settings|Set format for time and date in digit pattern 16951 +|Background|Set display or hide background of object 16952 +|Set text|Set text display style; 16953 +|Display|Set object position and size 16954 +))) 16955 + 16956 +**Histogram** 16957 + 16958 +It is used for display more than one tag value in Bar graph format. 16959 + 16960 +((( 16961 +|=**Items**|=**Description** 16962 +|Add new group|Maximum is 8, add items for this object, also set colors 16963 +|Add monitoring point|Set read tag for every item, 16964 +|Style|Set object display style such as color, use picture as background or not 16965 +|Display|Set object position and size 16966 +))) 16967 + 16968 +**Alarm record display** 16969 + 16970 +It is used for display alarm information of V-BOX. It can support current and history alarm. 16971 + 16972 +((( 16973 +|=**Items**|=**Description** 16974 +|Select box|Link to V-BOX 16975 +|Alarm type|Select current alarm or history alarm or all 16976 +|Start date|Alarm display start date 16977 +|End date|Alarm display end date 16978 +|Format|Set display format for date and time 16979 +|Sequence|It provides two type, one is order, and the other is reverse order 16980 +|Display content|Users could select display contents by check them 16981 +|Style|Set colors for different parts 16982 +|Display|Set object position and size 16983 +))) 16984 + 16985 +**History trend chart** 16986 + 16987 +The history trend will display data record with graph. X axis represents as time, and Y axis represents as data. 16988 + 16989 +((( 16990 +|=(% colspan="2" %)**Items**|=**Description** 16991 +|(% colspan="2" %)Basic|Set numbers of curve in object and select style for every curves including color, link tag 16992 +|(% rowspan="11" %)Style|Display form|Two type, one is curve, and the other is table 16993 +|Start date|Start date of history data 16994 +|End date|End date of history data 16995 +|Format|Time and date format for display 16996 +|Sequence|Two types, order or reverse order 16997 +|Y range|Two types, fixed and adaptive 16998 +|Set text|Set font size, color and other styles. 16999 +|Transparency|Set transparency of object 17000 +|Background color|Two types, translucent or transparent 17001 +|Gradient way|Set display way and color 17002 +|Display bar|Check it to display screen bar 17003 +|(% colspan="2" %)Display|Set object position and size 17004 +))) 17005 + 17006 +**Indirect screen display** 17007 + 17008 +This object is used for calling screens when condition is met. 17009 + 17010 +((( 17011 +|=(% colspan="2" %)**Items**|=**Description** 17012 +|(% rowspan="4" %)Basic|Conditional trigger|It provides bit, word condition and unconditional 17013 +|Bind monitoring point|Link to tag for triggering 17014 +|Trigger condition|for bit address, it requires ON or OFF, for word address, different value corresponds to different screens. 17015 +|Designated screen|Only for bit address as trigger. When condition is met, display this screen 17016 +|(% colspan="2" %)Style|Set object display style such as display title bar or display or hide background 17017 +|(% colspan="2" %)Display|Set object position and size 17018 +))) 17019 + 17020 +**Ring chart** 17021 + 17022 +Display value as ring chart 17023 + 17024 +((( 17025 +|=(% colspan="2" %)**Items**|=**Description** 17026 +|(% rowspan="7" %)Basic|Monitor point|Link to tag for data reading 17027 +|Range|Set fixed range or variable range 17028 +|Scales|Set scales such as major and minor numbers, colors and so on 17029 +|Designated screen|Only for bit address as trigger. When condition is met, display this screen 17030 +|Numerical scale display|Check it to display scale 17031 +|Start angle|Set start angle for scale 17032 +|Color|Color setting for bar and background 17033 +|(% colspan="2" %)Alarm Zone|Set alarm range and colors 17034 +|(% colspan="2" %)Display|Set object position and size 17035 +))) 17036 + 17037 +**Pie chart** 17038 + 17039 +Display more than one value in one pie chart 17040 + 17041 +((( 17042 +|=(% colspan="2" %)**Items**|=**Description** 17043 +|(% colspan="2" %)Monitor point|Add read addresses, the maximum is 8 17044 +|(% rowspan="3" %)Style|Pattern|Set alarm range and colors 17045 +|Numerical scale|Check it to display value in object 17046 +|Monitoring name display|Check it to display name in object 17047 +|(% colspan="2" %)Display|Set object position and size 17048 +))) 17049 + 17050 +== Common object == 17051 + 17052 +(% style="text-align:center" %) 17053 +[[image:V-BOX cloud configuration user manual_html_c84a5d0032df07e2.png||height="420" width="250" class="img-thumbnail"]] 17054 + 17055 +=== Display frame === 17056 + 17057 +After binding the monitoring point, the data of the monitoring point can be displayed in real time. 17058 + 17059 +|=**Item**|=**Description** 17060 +|Monitoring Point|Set operating address for this object (Read and write can be different); 17061 +|Read-write permission|There are three modes for it, users could select according to requirements; 17062 +|Set Text|It is used for setting style of text and display direction 17063 +|Style|It is used for setting object display, like background color; 17064 +|Expansion|It is used for setting expansion function, like lock position; 17065 +|Display|It is used for setting object position and size 17066 + 17067 +* **Bit /Word Indicator** 17068 + 17069 +Indicator could monitor and display the specified PLC or HMI bit address, and its state changes according to the specified address value. 17070 + 17071 +((( 17072 +|**Items**|**Description** 17073 +|Monitor Point|Set reading address for this object; 17074 +|Status|Set text for every status; 17075 +|Picture|Set picture for every status; 17076 +|Expansion|Set display expansion function, such as blink 17077 +|Display|Set object position and size 17078 +))) 17079 + 17080 +* **Bit/ Word Switch** 17081 + 17082 +Switch could operate the specified PLC or HMI bit address, and its state changes according to the specified address value. 17083 + 17084 +((( 17085 +|**Items**|**Description** 17086 +|Monitor Point|Set operating address for this object (Read and write can be different); 17087 +|Read-write permission|There are three modes for it, users could select according to requirements; 17088 +|Pop up a confirmation box|Check it to enable confirmation box for operating; 17089 +|Status|Set text for every status; 17090 +|Picture|Set picture for every status; 17091 +|Expansion|Set display expansion function, such as blink 17092 +|Display|Set object position and size 17093 +))) 17094 + 17095 +* **Dashboard** 17096 + 17097 +Display the value of address in real time using the dashboard. 17098 + 17099 +((( 17100 +|**Items**|**Description** 17101 +|Monitor Point|Set operating address for this object (Read and write can be different); 17102 +|Select|Set dashboard display range, there are two modes, Constant and Variable 17103 +|Scale value|Check it to display value; 17104 +|Select Language|Set text for object; 17105 +|Style|Set object display style such as color, scales number; 17106 +|Alarm Zone|Set range and color for alarm 17107 +|Display|Set object position and size 17108 +))) 17109 + 17110 +* **Bar graph** 17111 + 17112 +Use the length or height of the rectangle to reflect the value of reading address so that the value could be visualized. 17113 + 17114 +((( 17115 +|**Items**|**Description** 17116 +|Monitor Point|Set operating address for this object (Read and write can be different); 17117 +|Digit Display|Check it to display digit value on bar; 17118 +|Progress bar direction|Select display direction; 17119 +|Scales|Set object scales display type and color; 17120 +|Bar color|Set color for bar; 17121 +|Background Display|Set color of bar background; 17122 +|Alarm Zone|Set range and color for alarm 17123 +|Display|Set object position and size 17124 +))) 17125 + 17126 +* **Real-Time Trend Chart** 17127 + 17128 +Use the curve to show the trend of the data over time. X-axis is time, Y-axis is variable. 17129 + 17130 +((( 17131 +|**Items**|**Description** 17132 +|Monitor Point|Set operating address for this object (Read and write can be different); 17133 +|Digit Display|Check it to display digit value on bar; 17134 +|Progress bar direction|Select display direction; 17135 +|Scales|Set object scales display type and color; 17136 +|Bar color|Set color for bar; 17137 +|Background Display|Set color of bar background; 17138 +|Alarm Zone|Set range and color for alarm 17139 +|Display|Set object position and size 17140 +| | 17141 +))) 17142 + 17143 +* **Flow pipe** 17144 + 17145 +This is a flowing animation object, users could set animation trigger condition for it, the monitor point could be both bit address and word address; 17146 + 17147 +((( 17148 +|**Items**|**Description** 17149 +|Border color|Set object background color; 17150 +|Color|Set flowing block color; 17151 +|Speed|Three modes for flowing block speed; 17152 +|Flow direction|Two modes for flowing direction; 17153 +|Monitor Point|Set trigger address; 17154 +|Trigger Condition|((( 17155 +Bit address: Select ON or OFF; 17156 + 17157 +Word address: Set value range; 17158 +))) 17159 +|Color Block Width|Set flowing block size; 17160 +|Color Block Length|Set flowing block size; 17161 +|Color Block Spacing|Set the spacing between flow blocks; 17162 +|Display Border|Select display or hide border; 17163 +|Alarm Zone|Set range and color for alarm 17164 +|Display|Set object position and size 17165 +))) 17166 + 17167 +**Tips for designing flow bar** 17168 + 17169 +When user need to simulate the flow of water in a pipe, please put the pipe picture at first, then hide the flow border and place it onto the pipe picture. 17170 + 17171 +* **Video object** 17172 + 17173 +Video object is used for playing the video file provided in the video source. 17174 + 17175 +((( 17176 +|**Items**|**Description** 17177 +|Border color|Set object background color; 17178 +|Color|Set flowing block color; 17179 +|Speed|Three modes for flowing block speed; 17180 +|Flow direction|Two modes for flowing direction; 17181 +|Monitor Point|Set trigger address; 17182 +|Trigger Condition|((( 17183 +Bit address: Select ON or OFF; 17184 + 17185 +Word address: Set value range; 17186 +))) 17187 +|Color Block Width|Set flowing block size; 17188 +|Color Block Length|Set flowing block size; 17189 +|Color Block Spacing|Set the spacing between flow blocks; 17190 +|Display Border|Select display or hide border; 17191 +|Alarm Zone|Set range and color for alarm 17192 +|Display|Set object position and size 17193 +))) 17194 + 17195 +* **Hyperlink** 17196 + 17197 +The object for link website; 17198 + 17199 +((( 17200 +|=**Items**|=**Description** 17201 +|Link address|Enter website; 17202 +|Open with|There are two options, user could select open with new window or current window; 17203 +|Select Language|One object could support three language, user could enter text for note object; 17204 +|Style|Set object display style such as color, use picture as background or not 17205 +|Display|Set object position and size 17206 +))) 17207 + 17208 +* **Function Switch** 17209 + 17210 +Function switch is designed to switch screens, and call and close sub screen. 17211 + 17212 +((( 17213 +|=**Items**|=**Description** 17214 +|Screen|Select the target screen for switch; 17215 +|Sub-screen|There are two options, user could select open with new window or current window; 17216 +|Previous|Switch to the previous screen 17217 +|Next|Switch to the next screen 17218 +|Return|Return to the screen before switch 17219 +|Text|Set text for object, including text font, color direction and so on; 17220 +|Style|Set object display style such as color, use picture as background or not 17221 +|Display|Set object position and size 17222 +))) 17223 + 17224 +* **Combination Switch** 17225 + 17226 +The combination switch supports the collection of multiple functions onto one object. When the object is pressed, multiple functions are arranged in sequence to meet the special requirements of user. 17227 + 17228 +((( 17229 +|=**Items**|=**Description** 17230 +|Bit operation|It provides [Bit copy], [Set ON], [Set OFF], [Switch] and [Bit Copy] functions. 17231 +|Word operation|It provides [Word copy], [Word set], [Increase] and [Decrease] functions, 17232 +|Arithmetic|[Add], [Subtract], [Multiply] and [Divide] functions 17233 +|Screen change|It provides screen switch function as [Function Switch], it supports [Previous], [Next], [Return], [Change to], and open, close sub-screen operations 17234 +|Delete|Delete selected item function; 17235 +|Empty|Delete all items in operation list; 17236 +|Up|Move the selected item up one row in operation list; 17237 +|Down|Move the selected item down one row in operation list; 17238 +))) 17239 + 17240 +**Time** 17241 + 17242 +It is used for displaying the time of the V-BOX, when the V-BOX is offline, the time will stay at the time when it is offline. 17243 + 17244 +((( 17245 +|=**Items**|=**Description** 17246 +|Monitoring box|Link a box for the time part 17247 +|Pattern|Two types, one is digit and the other is clock 17248 +|Format settings|Set format for time and date in digit pattern 17249 +|Background|Set display or hide background of object 17250 +|Set text|Set text display style; 17251 +|Display|Set object position and size 17252 +))) 17253 + 17254 +**Histogram** 17255 + 17256 +It is used for display more than one tag value in Bar graph format. 17257 + 17258 +((( 17259 +|=**Items**|=**Description** 17260 +|Add new group|Maximum is 8, add items for this object, also set colors 17261 +|Add monitoring point|Set read tag for every item, 17262 +|Style|Set object display style such as color, use picture as background or not 17263 +|Display|Set object position and size 17264 +))) 17265 + 17266 +**Alarm record display** 17267 + 17268 +It is used for display alarm information of V-BOX. It can support current and history alarm. 17269 + 17270 +((( 17271 +|=**Items**|=**Description** 17272 +|Select box|Link to V-BOX 17273 +|Alarm type|Select current alarm or history alarm or all 17274 +|Start date|Alarm display start date 17275 +|End date|Alarm display end date 17276 +|Format|Set display format for date and time 17277 +|Sequence|It provides two type, one is order, and the other is reverse order 17278 +|Display content|Users could select display contents by check them 17279 +|Style|Set colors for different parts 17280 +|Display|Set object position and size 17281 +))) 17282 + 17283 +**History trend chart** 17284 + 17285 +The history trend will display data record with graph. X axis represents as time, and Y axis represents as data. 17286 + 17287 +((( 17288 +|=(% colspan="2" %)**Items**|=**Description** 17289 +|(% colspan="2" %)Basic|Set numbers of curve in object and select style for every curves including color, link tag 17290 +|(% rowspan="11" %)Style|Display form|Two type, one is curve, and the other is table 17291 +|Start date|Start date of history data 17292 +|End date|End date of history data 17293 +|Format|Time and date format for display 17294 +|Sequence|Two types, order or reverse order 17295 +|Y range|Two types, fixed and adaptive 17296 +|Set text|Set font size, color and other styles. 17297 +|Transparency|Set transparency of object 17298 +|Background color|Two types, translucent or transparent 17299 +|Gradient way|Set display way and color 17300 +|Display bar|Check it to display screen bar 17301 +|(% colspan="2" %)Display|Set object position and size 17302 +))) 17303 + 17304 +**Indirect screen display** 17305 + 17306 +This object is used for calling screens when condition is met. 17307 + 17308 +((( 17309 +|=(% colspan="2" %)**Items**|=**Description** 17310 +|(% rowspan="4" %)Basic|Conditional trigger|It provides bit, word condition and unconditional 17311 +|Bind monitoring point|Link to tag for triggering 17312 +|Trigger condition|for bit address, it requires ON or OFF, for word address, different value corresponds to different screens. 17313 +|Designated screen|Only for bit address as trigger. When condition is met, display this screen 17314 +|(% colspan="2" %)Style|Set object display style such as display title bar or display or hide background 17315 +|(% colspan="2" %)Display|Set object position and size 17316 +))) 17317 + 17318 +**Ring chart** 17319 + 17320 +Display value as ring chart 17321 + 17322 +((( 17323 +|=(% colspan="2" %)**Items**|=**Description** 17324 +|(% rowspan="7" %)Basic|Monitor point|Link to tag for data reading 17325 +|Range|Set fixed range or variable range 17326 +|Scales|Set scales such as major and minor numbers, colors and so on 17327 +|Designated screen|Only for bit address as trigger. When condition is met, display this screen 17328 +|Numerical scale display|Check it to display scale 17329 +|Start angle|Set start angle for scale 17330 +|Color|Color setting for bar and background 17331 +|(% colspan="2" %)Alarm Zone|Set alarm range and colors 17332 +|(% colspan="2" %)Display|Set object position and size 17333 +))) 17334 + 17335 +**Pie chart** 17336 + 17337 +Display more than one value in one pie chart 17338 + 17339 +((( 17340 +|=(% colspan="2" %)**Items**|=**Description** 17341 +|(% colspan="2" %)Monitor point|Add read addresses, the maximum is 8 17342 +|(% rowspan="3" %)Style|Pattern|Set alarm range and colors 17343 +|Numerical scale|Check it to display value in object 17344 +|Monitoring name display|Check it to display name in object 17345 +|(% colspan="2" %)Display|Set object position and size 17346 +))) 17347 + 17348 +== Common object == 17349 + 17350 +(% style="text-align:center" %) 17351 +[[image:V-BOX cloud configuration user manual_html_c84a5d0032df07e2.png||height="420" width="250" class="img-thumbnail"]] 17352 + 17353 +=== Display frame === 17354 + 17355 +After binding the monitoring point, the data of the monitoring point can be displayed in real time. 17356 + 17357 +|=**Item**|=**Description** 17358 +|Monitoring Point|Set operating address for this object (Read and write can be different); 17359 +|Read-write permission|There are three modes for it, users could select according to requirements; 17360 +|Set Text|It is used for setting style of text and display direction 17361 +|Style|It is used for setting object display, like background color; 17362 +|Expansion|It is used for setting expansion function, like lock position; 17363 +|Display|It is used for setting object position and size 17364 + 17365 +* **Bit /Word Indicator** 17366 + 17367 +Indicator could monitor and display the specified PLC or HMI bit address, and its state changes according to the specified address value. 17368 + 17369 +((( 17370 +|**Items**|**Description** 17371 +|Monitor Point|Set reading address for this object; 17372 +|Status|Set text for every status; 17373 +|Picture|Set picture for every status; 17374 +|Expansion|Set display expansion function, such as blink 17375 +|Display|Set object position and size 17376 +))) 17377 + 17378 +* **Bit/ Word Switch** 17379 + 17380 +Switch could operate the specified PLC or HMI bit address, and its state changes according to the specified address value. 17381 + 17382 +((( 17383 +|**Items**|**Description** 17384 +|Monitor Point|Set operating address for this object (Read and write can be different); 17385 +|Read-write permission|There are three modes for it, users could select according to requirements; 17386 +|Pop up a confirmation box|Check it to enable confirmation box for operating; 17387 +|Status|Set text for every status; 17388 +|Picture|Set picture for every status; 17389 +|Expansion|Set display expansion function, such as blink 17390 +|Display|Set object position and size 17391 +))) 17392 + 17393 +* **Dashboard** 17394 + 17395 +Display the value of address in real time using the dashboard. 17396 + 17397 +((( 17398 +|**Items**|**Description** 17399 +|Monitor Point|Set operating address for this object (Read and write can be different); 17400 +|Select|Set dashboard display range, there are two modes, Constant and Variable 17401 +|Scale value|Check it to display value; 17402 +|Select Language|Set text for object; 17403 +|Style|Set object display style such as color, scales number; 17404 +|Alarm Zone|Set range and color for alarm 17405 +|Display|Set object position and size 17406 +))) 17407 + 17408 +* **Bar graph** 17409 + 17410 +Use the length or height of the rectangle to reflect the value of reading address so that the value could be visualized. 17411 + 17412 +((( 17413 +|**Items**|**Description** 17414 +|Monitor Point|Set operating address for this object (Read and write can be different); 17415 +|Digit Display|Check it to display digit value on bar; 17416 +|Progress bar direction|Select display direction; 17417 +|Scales|Set object scales display type and color; 17418 +|Bar color|Set color for bar; 17419 +|Background Display|Set color of bar background; 17420 +|Alarm Zone|Set range and color for alarm 17421 +|Display|Set object position and size 17422 +))) 17423 + 17424 +* **Real-Time Trend Chart** 17425 + 17426 +Use the curve to show the trend of the data over time. X-axis is time, Y-axis is variable. 17427 + 17428 +((( 17429 +|**Items**|**Description** 17430 +|Monitor Point|Set operating address for this object (Read and write can be different); 17431 +|Digit Display|Check it to display digit value on bar; 17432 +|Progress bar direction|Select display direction; 17433 +|Scales|Set object scales display type and color; 17434 +|Bar color|Set color for bar; 17435 +|Background Display|Set color of bar background; 17436 +|Alarm Zone|Set range and color for alarm 17437 +|Display|Set object position and size 17438 +| | 17439 +))) 17440 + 17441 +* **Flow pipe** 17442 + 17443 +This is a flowing animation object, users could set animation trigger condition for it, the monitor point could be both bit address and word address; 17444 + 17445 +((( 17446 +|**Items**|**Description** 17447 +|Border color|Set object background color; 17448 +|Color|Set flowing block color; 17449 +|Speed|Three modes for flowing block speed; 17450 +|Flow direction|Two modes for flowing direction; 17451 +|Monitor Point|Set trigger address; 17452 +|Trigger Condition|((( 17453 +Bit address: Select ON or OFF; 17454 + 17455 +Word address: Set value range; 17456 +))) 17457 +|Color Block Width|Set flowing block size; 17458 +|Color Block Length|Set flowing block size; 17459 +|Color Block Spacing|Set the spacing between flow blocks; 17460 +|Display Border|Select display or hide border; 17461 +|Alarm Zone|Set range and color for alarm 17462 +|Display|Set object position and size 17463 +))) 17464 + 17465 +**Tips for designing flow bar** 17466 + 17467 +When user need to simulate the flow of water in a pipe, please put the pipe picture at first, then hide the flow border and place it onto the pipe picture. 17468 + 17469 +* **Video object** 17470 + 17471 +Video object is used for playing the video file provided in the video source. 17472 + 17473 +((( 17474 +|**Items**|**Description** 17475 +|Border color|Set object background color; 17476 +|Color|Set flowing block color; 17477 +|Speed|Three modes for flowing block speed; 17478 +|Flow direction|Two modes for flowing direction; 17479 +|Monitor Point|Set trigger address; 17480 +|Trigger Condition|((( 17481 +Bit address: Select ON or OFF; 17482 + 17483 +Word address: Set value range; 17484 +))) 17485 +|Color Block Width|Set flowing block size; 17486 +|Color Block Length|Set flowing block size; 17487 +|Color Block Spacing|Set the spacing between flow blocks; 17488 +|Display Border|Select display or hide border; 17489 +|Alarm Zone|Set range and color for alarm 17490 +|Display|Set object position and size 17491 +))) 17492 + 17493 +* **Hyperlink** 17494 + 17495 +The object for link website; 17496 + 17497 +((( 17498 +|=**Items**|=**Description** 17499 +|Link address|Enter website; 17500 +|Open with|There are two options, user could select open with new window or current window; 17501 +|Select Language|One object could support three language, user could enter text for note object; 17502 +|Style|Set object display style such as color, use picture as background or not 17503 +|Display|Set object position and size 17504 +))) 17505 + 17506 +* **Function Switch** 17507 + 17508 +Function switch is designed to switch screens, and call and close sub screen. 17509 + 17510 +((( 17511 +|=**Items**|=**Description** 17512 +|Screen|Select the target screen for switch; 17513 +|Sub-screen|There are two options, user could select open with new window or current window; 17514 +|Previous|Switch to the previous screen 17515 +|Next|Switch to the next screen 17516 +|Return|Return to the screen before switch 17517 +|Text|Set text for object, including text font, color direction and so on; 17518 +|Style|Set object display style such as color, use picture as background or not 17519 +|Display|Set object position and size 17520 +))) 17521 + 17522 +* **Combination Switch** 17523 + 17524 +The combination switch supports the collection of multiple functions onto one object. When the object is pressed, multiple functions are arranged in sequence to meet the special requirements of user. 17525 + 17526 +((( 17527 +|=**Items**|=**Description** 17528 +|Bit operation|It provides [Bit copy], [Set ON], [Set OFF], [Switch] and [Bit Copy] functions. 17529 +|Word operation|It provides [Word copy], [Word set], [Increase] and [Decrease] functions, 17530 +|Arithmetic|[Add], [Subtract], [Multiply] and [Divide] functions 17531 +|Screen change|It provides screen switch function as [Function Switch], it supports [Previous], [Next], [Return], [Change to], and open, close sub-screen operations 17532 +|Delete|Delete selected item function; 17533 +|Empty|Delete all items in operation list; 17534 +|Up|Move the selected item up one row in operation list; 17535 +|Down|Move the selected item down one row in operation list; 17536 +))) 17537 + 17538 +**Time** 17539 + 17540 +It is used for displaying the time of the V-BOX, when the V-BOX is offline, the time will stay at the time when it is offline. 17541 + 17542 +((( 17543 +|=**Items**|=**Description** 17544 +|Monitoring box|Link a box for the time part 17545 +|Pattern|Two types, one is digit and the other is clock 17546 +|Format settings|Set format for time and date in digit pattern 17547 +|Background|Set display or hide background of object 17548 +|Set text|Set text display style; 17549 +|Display|Set object position and size 17550 +))) 17551 + 17552 +**Histogram** 17553 + 17554 +It is used for display more than one tag value in Bar graph format. 17555 + 17556 +((( 17557 +|=**Items**|=**Description** 17558 +|Add new group|Maximum is 8, add items for this object, also set colors 17559 +|Add monitoring point|Set read tag for every item, 17560 +|Style|Set object display style such as color, use picture as background or not 17561 +|Display|Set object position and size 17562 +))) 17563 + 17564 +**Alarm record display** 17565 + 17566 +It is used for display alarm information of V-BOX. It can support current and history alarm. 17567 + 17568 +((( 17569 +|=**Items**|=**Description** 17570 +|Select box|Link to V-BOX 17571 +|Alarm type|Select current alarm or history alarm or all 17572 +|Start date|Alarm display start date 17573 +|End date|Alarm display end date 17574 +|Format|Set display format for date and time 17575 +|Sequence|It provides two type, one is order, and the other is reverse order 17576 +|Display content|Users could select display contents by check them 17577 +|Style|Set colors for different parts 17578 +|Display|Set object position and size 17579 +))) 17580 + 17581 +**History trend chart** 17582 + 17583 +The history trend will display data record with graph. X axis represents as time, and Y axis represents as data. 17584 + 17585 +((( 17586 +|=(% colspan="2" %)**Items**|=**Description** 17587 +|(% colspan="2" %)Basic|Set numbers of curve in object and select style for every curves including color, link tag 17588 +|(% rowspan="11" %)Style|Display form|Two type, one is curve, and the other is table 17589 +|Start date|Start date of history data 17590 +|End date|End date of history data 17591 +|Format|Time and date format for display 17592 +|Sequence|Two types, order or reverse order 17593 +|Y range|Two types, fixed and adaptive 17594 +|Set text|Set font size, color and other styles. 17595 +|Transparency|Set transparency of object 17596 +|Background color|Two types, translucent or transparent 17597 +|Gradient way|Set display way and color 17598 +|Display bar|Check it to display screen bar 17599 +|(% colspan="2" %)Display|Set object position and size 17600 +))) 17601 + 17602 +**Indirect screen display** 17603 + 17604 +This object is used for calling screens when condition is met. 17605 + 17606 +((( 17607 +|=(% colspan="2" %)**Items**|=**Description** 17608 +|(% rowspan="4" %)Basic|Conditional trigger|It provides bit, word condition and unconditional 17609 +|Bind monitoring point|Link to tag for triggering 17610 +|Trigger condition|for bit address, it requires ON or OFF, for word address, different value corresponds to different screens. 17611 +|Designated screen|Only for bit address as trigger. When condition is met, display this screen 17612 +|(% colspan="2" %)Style|Set object display style such as display title bar or display or hide background 17613 +|(% colspan="2" %)Display|Set object position and size 17614 +))) 17615 + 17616 +**Ring chart** 17617 + 17618 +Display value as ring chart 17619 + 17620 +((( 17621 +|=(% colspan="2" %)**Items**|=**Description** 17622 +|(% rowspan="7" %)Basic|Monitor point|Link to tag for data reading 17623 +|Range|Set fixed range or variable range 17624 +|Scales|Set scales such as major and minor numbers, colors and so on 17625 +|Designated screen|Only for bit address as trigger. When condition is met, display this screen 17626 +|Numerical scale display|Check it to display scale 17627 +|Start angle|Set start angle for scale 17628 +|Color|Color setting for bar and background 17629 +|(% colspan="2" %)Alarm Zone|Set alarm range and colors 17630 +|(% colspan="2" %)Display|Set object position and size 17631 +))) 17632 + 17633 +**Pie chart** 17634 + 17635 +Display more than one value in one pie chart 17636 + 17637 +((( 17638 +|=(% colspan="2" %)**Items**|=**Description** 17639 +|(% colspan="2" %)Monitor point|Add read addresses, the maximum is 8 17640 +|(% rowspan="3" %)Style|Pattern|Set alarm range and colors 17641 +|Numerical scale|Check it to display value in object 17642 +|Monitoring name display|Check it to display name in object 17643 +|(% colspan="2" %)Display|Set object position and size 17644 +))) 17645 + 17646 +== Common object == 17647 + 17648 +(% style="text-align:center" %) 17649 +[[image:V-BOX cloud configuration user manual_html_c84a5d0032df07e2.png||height="420" width="250" class="img-thumbnail"]] 17650 + 17651 +=== Display frame === 17652 + 17653 +After binding the monitoring point, the data of the monitoring point can be displayed in real time. 17654 + 17655 +|=**Item**|=**Description** 17656 +|Monitoring Point|Set operating address for this object (Read and write can be different); 17657 +|Read-write permission|There are three modes for it, users could select according to requirements; 17658 +|Set Text|It is used for setting style of text and display direction 17659 +|Style|It is used for setting object display, like background color; 17660 +|Expansion|It is used for setting expansion function, like lock position; 17661 +|Display|It is used for setting object position and size 17662 + 17663 +* **Bit /Word Indicator** 17664 + 17665 +Indicator could monitor and display the specified PLC or HMI bit address, and its state changes according to the specified address value. 17666 + 17667 +((( 17668 +|**Items**|**Description** 17669 +|Monitor Point|Set reading address for this object; 17670 +|Status|Set text for every status; 17671 +|Picture|Set picture for every status; 17672 +|Expansion|Set display expansion function, such as blink 17673 +|Display|Set object position and size 17674 +))) 17675 + 17676 +* **Bit/ Word Switch** 17677 + 17678 +Switch could operate the specified PLC or HMI bit address, and its state changes according to the specified address value. 17679 + 17680 +((( 17681 +|**Items**|**Description** 17682 +|Monitor Point|Set operating address for this object (Read and write can be different); 17683 +|Read-write permission|There are three modes for it, users could select according to requirements; 17684 +|Pop up a confirmation box|Check it to enable confirmation box for operating; 17685 +|Status|Set text for every status; 17686 +|Picture|Set picture for every status; 17687 +|Expansion|Set display expansion function, such as blink 17688 +|Display|Set object position and size 17689 +))) 17690 + 17691 +* **Dashboard** 17692 + 17693 +Display the value of address in real time using the dashboard. 17694 + 17695 +((( 17696 +|**Items**|**Description** 17697 +|Monitor Point|Set operating address for this object (Read and write can be different); 17698 +|Select|Set dashboard display range, there are two modes, Constant and Variable 17699 +|Scale value|Check it to display value; 17700 +|Select Language|Set text for object; 17701 +|Style|Set object display style such as color, scales number; 17702 +|Alarm Zone|Set range and color for alarm 17703 +|Display|Set object position and size 17704 +))) 17705 + 17706 +* **Bar graph** 17707 + 17708 +Use the length or height of the rectangle to reflect the value of reading address so that the value could be visualized. 17709 + 17710 +((( 17711 +|**Items**|**Description** 17712 +|Monitor Point|Set operating address for this object (Read and write can be different); 17713 +|Digit Display|Check it to display digit value on bar; 17714 +|Progress bar direction|Select display direction; 17715 +|Scales|Set object scales display type and color; 17716 +|Bar color|Set color for bar; 17717 +|Background Display|Set color of bar background; 17718 +|Alarm Zone|Set range and color for alarm 17719 +|Display|Set object position and size 17720 +))) 17721 + 17722 +* **Real-Time Trend Chart** 17723 + 17724 +Use the curve to show the trend of the data over time. X-axis is time, Y-axis is variable. 17725 + 17726 +((( 17727 +|**Items**|**Description** 17728 +|Monitor Point|Set operating address for this object (Read and write can be different); 17729 +|Digit Display|Check it to display digit value on bar; 17730 +|Progress bar direction|Select display direction; 17731 +|Scales|Set object scales display type and color; 17732 +|Bar color|Set color for bar; 17733 +|Background Display|Set color of bar background; 17734 +|Alarm Zone|Set range and color for alarm 17735 +|Display|Set object position and size 17736 +| | 17737 +))) 17738 + 17739 +* **Flow pipe** 17740 + 17741 +This is a flowing animation object, users could set animation trigger condition for it, the monitor point could be both bit address and word address; 17742 + 17743 +((( 17744 +|**Items**|**Description** 17745 +|Border color|Set object background color; 17746 +|Color|Set flowing block color; 17747 +|Speed|Three modes for flowing block speed; 17748 +|Flow direction|Two modes for flowing direction; 17749 +|Monitor Point|Set trigger address; 17750 +|Trigger Condition|((( 17751 +Bit address: Select ON or OFF; 17752 + 17753 +Word address: Set value range; 17754 +))) 17755 +|Color Block Width|Set flowing block size; 17756 +|Color Block Length|Set flowing block size; 17757 +|Color Block Spacing|Set the spacing between flow blocks; 17758 +|Display Border|Select display or hide border; 17759 +|Alarm Zone|Set range and color for alarm 17760 +|Display|Set object position and size 17761 +))) 17762 + 17763 +**Tips for designing flow bar** 17764 + 17765 +When user need to simulate the flow of water in a pipe, please put the pipe picture at first, then hide the flow border and place it onto the pipe picture. 17766 + 17767 +* **Video object** 17768 + 17769 +Video object is used for playing the video file provided in the video source. 17770 + 17771 +((( 17772 +|**Items**|**Description** 17773 +|Border color|Set object background color; 17774 +|Color|Set flowing block color; 17775 +|Speed|Three modes for flowing block speed; 17776 +|Flow direction|Two modes for flowing direction; 17777 +|Monitor Point|Set trigger address; 17778 +|Trigger Condition|((( 17779 +Bit address: Select ON or OFF; 17780 + 17781 +Word address: Set value range; 17782 +))) 17783 +|Color Block Width|Set flowing block size; 17784 +|Color Block Length|Set flowing block size; 17785 +|Color Block Spacing|Set the spacing between flow blocks; 17786 +|Display Border|Select display or hide border; 17787 +|Alarm Zone|Set range and color for alarm 17788 +|Display|Set object position and size 17789 +))) 17790 + 17791 +* **Hyperlink** 17792 + 17793 +The object for link website; 17794 + 17795 +((( 17796 +|=**Items**|=**Description** 17797 +|Link address|Enter website; 17798 +|Open with|There are two options, user could select open with new window or current window; 17799 +|Select Language|One object could support three language, user could enter text for note object; 17800 +|Style|Set object display style such as color, use picture as background or not 17801 +|Display|Set object position and size 17802 +))) 17803 + 17804 +* **Function Switch** 17805 + 17806 +Function switch is designed to switch screens, and call and close sub screen. 17807 + 17808 +((( 17809 +|=**Items**|=**Description** 17810 +|Screen|Select the target screen for switch; 17811 +|Sub-screen|There are two options, user could select open with new window or current window; 17812 +|Previous|Switch to the previous screen 17813 +|Next|Switch to the next screen 17814 +|Return|Return to the screen before switch 17815 +|Text|Set text for object, including text font, color direction and so on; 17816 +|Style|Set object display style such as color, use picture as background or not 17817 +|Display|Set object position and size 17818 +))) 17819 + 17820 +* **Combination Switch** 17821 + 17822 +The combination switch supports the collection of multiple functions onto one object. When the object is pressed, multiple functions are arranged in sequence to meet the special requirements of user. 17823 + 17824 +((( 17825 +|=**Items**|=**Description** 17826 +|Bit operation|It provides [Bit copy], [Set ON], [Set OFF], [Switch] and [Bit Copy] functions. 17827 +|Word operation|It provides [Word copy], [Word set], [Increase] and [Decrease] functions, 17828 +|Arithmetic|[Add], [Subtract], [Multiply] and [Divide] functions 17829 +|Screen change|It provides screen switch function as [Function Switch], it supports [Previous], [Next], [Return], [Change to], and open, close sub-screen operations 17830 +|Delete|Delete selected item function; 17831 +|Empty|Delete all items in operation list; 17832 +|Up|Move the selected item up one row in operation list; 17833 +|Down|Move the selected item down one row in operation list; 17834 +))) 17835 + 17836 +**Time** 17837 + 17838 +It is used for displaying the time of the V-BOX, when the V-BOX is offline, the time will stay at the time when it is offline. 17839 + 17840 +((( 17841 +|=**Items**|=**Description** 17842 +|Monitoring box|Link a box for the time part 17843 +|Pattern|Two types, one is digit and the other is clock 17844 +|Format settings|Set format for time and date in digit pattern 17845 +|Background|Set display or hide background of object 17846 +|Set text|Set text display style; 17847 +|Display|Set object position and size 17848 +))) 17849 + 17850 +**Histogram** 17851 + 17852 +It is used for display more than one tag value in Bar graph format. 17853 + 17854 +((( 17855 +|=**Items**|=**Description** 17856 +|Add new group|Maximum is 8, add items for this object, also set colors 17857 +|Add monitoring point|Set read tag for every item, 17858 +|Style|Set object display style such as color, use picture as background or not 17859 +|Display|Set object position and size 17860 +))) 17861 + 17862 +**Alarm record display** 17863 + 17864 +It is used for display alarm information of V-BOX. It can support current and history alarm. 17865 + 17866 +((( 17867 +|=**Items**|=**Description** 17868 +|Select box|Link to V-BOX 17869 +|Alarm type|Select current alarm or history alarm or all 17870 +|Start date|Alarm display start date 17871 +|End date|Alarm display end date 17872 +|Format|Set display format for date and time 17873 +|Sequence|It provides two type, one is order, and the other is reverse order 17874 +|Display content|Users could select display contents by check them 17875 +|Style|Set colors for different parts 17876 +|Display|Set object position and size 17877 +))) 17878 + 17879 +**History trend chart** 17880 + 17881 +The history trend will display data record with graph. X axis represents as time, and Y axis represents as data. 17882 + 17883 +((( 17884 +|=(% colspan="2" %)**Items**|=**Description** 17885 +|(% colspan="2" %)Basic|Set numbers of curve in object and select style for every curves including color, link tag 17886 +|(% rowspan="11" %)Style|Display form|Two type, one is curve, and the other is table 17887 +|Start date|Start date of history data 17888 +|End date|End date of history data 17889 +|Format|Time and date format for display 17890 +|Sequence|Two types, order or reverse order 17891 +|Y range|Two types, fixed and adaptive 17892 +|Set text|Set font size, color and other styles. 17893 +|Transparency|Set transparency of object 17894 +|Background color|Two types, translucent or transparent 17895 +|Gradient way|Set display way and color 17896 +|Display bar|Check it to display screen bar 17897 +|(% colspan="2" %)Display|Set object position and size 17898 +))) 17899 + 17900 +**Indirect screen display** 17901 + 17902 +This object is used for calling screens when condition is met. 17903 + 17904 +((( 17905 +|=(% colspan="2" %)**Items**|=**Description** 17906 +|(% rowspan="4" %)Basic|Conditional trigger|It provides bit, word condition and unconditional 17907 +|Bind monitoring point|Link to tag for triggering 17908 +|Trigger condition|for bit address, it requires ON or OFF, for word address, different value corresponds to different screens. 17909 +|Designated screen|Only for bit address as trigger. When condition is met, display this screen 17910 +|(% colspan="2" %)Style|Set object display style such as display title bar or display or hide background 17911 +|(% colspan="2" %)Display|Set object position and size 17912 +))) 17913 + 17914 +**Ring chart** 17915 + 17916 +Display value as ring chart 17917 + 17918 +((( 17919 +|=(% colspan="2" %)**Items**|=**Description** 17920 +|(% rowspan="7" %)Basic|Monitor point|Link to tag for data reading 17921 +|Range|Set fixed range or variable range 17922 +|Scales|Set scales such as major and minor numbers, colors and so on 17923 +|Designated screen|Only for bit address as trigger. When condition is met, display this screen 17924 +|Numerical scale display|Check it to display scale 17925 +|Start angle|Set start angle for scale 17926 +|Color|Color setting for bar and background 17927 +|(% colspan="2" %)Alarm Zone|Set alarm range and colors 17928 +|(% colspan="2" %)Display|Set object position and size 17929 +))) 17930 + 17931 +**Pie chart** 17932 + 17933 +Display more than one value in one pie chart 17934 + 17935 +((( 17936 +|=(% colspan="2" %)**Items**|=**Description** 17937 +|(% colspan="2" %)Monitor point|Add read addresses, the maximum is 8 17938 +|(% rowspan="3" %)Style|Pattern|Set alarm range and colors 17939 +|Numerical scale|Check it to display value in object 17940 +|Monitoring name display|Check it to display name in object 17941 +|(% colspan="2" %)Display|Set object position and size 17942 +))) 17943 + 17944 +== Common object == 17945 + 17946 +(% style="text-align:center" %) 17947 +[[image:V-BOX cloud configuration user manual_html_c84a5d0032df07e2.png||height="420" width="250" class="img-thumbnail"]] 17948 + 17949 +=== Display frame === 17950 + 17951 +After binding the monitoring point, the data of the monitoring point can be displayed in real time. 17952 + 17953 +|=**Item**|=**Description** 17954 +|Monitoring Point|Set operating address for this object (Read and write can be different); 17955 +|Read-write permission|There are three modes for it, users could select according to requirements; 17956 +|Set Text|It is used for setting style of text and display direction 17957 +|Style|It is used for setting object display, like background color; 17958 +|Expansion|It is used for setting expansion function, like lock position; 17959 +|Display|It is used for setting object position and size 17960 + 17961 +* **Bit /Word Indicator** 17962 + 17963 +Indicator could monitor and display the specified PLC or HMI bit address, and its state changes according to the specified address value. 17964 + 17965 +((( 17966 +|**Items**|**Description** 17967 +|Monitor Point|Set reading address for this object; 17968 +|Status|Set text for every status; 17969 +|Picture|Set picture for every status; 17970 +|Expansion|Set display expansion function, such as blink 17971 +|Display|Set object position and size 17972 +))) 17973 + 17974 +* **Bit/ Word Switch** 17975 + 17976 +Switch could operate the specified PLC or HMI bit address, and its state changes according to the specified address value. 17977 + 17978 +((( 17979 +|**Items**|**Description** 17980 +|Monitor Point|Set operating address for this object (Read and write can be different); 17981 +|Read-write permission|There are three modes for it, users could select according to requirements; 17982 +|Pop up a confirmation box|Check it to enable confirmation box for operating; 17983 +|Status|Set text for every status; 17984 +|Picture|Set picture for every status; 17985 +|Expansion|Set display expansion function, such as blink 17986 +|Display|Set object position and size 17987 +))) 17988 + 17989 +* **Dashboard** 17990 + 17991 +Display the value of address in real time using the dashboard. 17992 + 17993 +((( 17994 +|**Items**|**Description** 17995 +|Monitor Point|Set operating address for this object (Read and write can be different); 17996 +|Select|Set dashboard display range, there are two modes, Constant and Variable 17997 +|Scale value|Check it to display value; 17998 +|Select Language|Set text for object; 17999 +|Style|Set object display style such as color, scales number; 18000 +|Alarm Zone|Set range and color for alarm 18001 +|Display|Set object position and size 18002 +))) 18003 + 18004 +* **Bar graph** 18005 + 18006 +Use the length or height of the rectangle to reflect the value of reading address so that the value could be visualized. 18007 + 18008 +((( 18009 +|**Items**|**Description** 18010 +|Monitor Point|Set operating address for this object (Read and write can be different); 18011 +|Digit Display|Check it to display digit value on bar; 18012 +|Progress bar direction|Select display direction; 18013 +|Scales|Set object scales display type and color; 18014 +|Bar color|Set color for bar; 18015 +|Background Display|Set color of bar background; 18016 +|Alarm Zone|Set range and color for alarm 18017 +|Display|Set object position and size 18018 +))) 18019 + 18020 +* **Real-Time Trend Chart** 18021 + 18022 +Use the curve to show the trend of the data over time. X-axis is time, Y-axis is variable. 18023 + 18024 +((( 18025 +|**Items**|**Description** 18026 +|Monitor Point|Set operating address for this object (Read and write can be different); 18027 +|Digit Display|Check it to display digit value on bar; 18028 +|Progress bar direction|Select display direction; 18029 +|Scales|Set object scales display type and color; 18030 +|Bar color|Set color for bar; 18031 +|Background Display|Set color of bar background; 18032 +|Alarm Zone|Set range and color for alarm 18033 +|Display|Set object position and size 18034 +| | 18035 +))) 18036 + 18037 +* **Flow pipe** 18038 + 18039 +This is a flowing animation object, users could set animation trigger condition for it, the monitor point could be both bit address and word address; 18040 + 18041 +((( 18042 +|**Items**|**Description** 18043 +|Border color|Set object background color; 18044 +|Color|Set flowing block color; 18045 +|Speed|Three modes for flowing block speed; 18046 +|Flow direction|Two modes for flowing direction; 18047 +|Monitor Point|Set trigger address; 18048 +|Trigger Condition|((( 18049 +Bit address: Select ON or OFF; 18050 + 18051 +Word address: Set value range; 18052 +))) 18053 +|Color Block Width|Set flowing block size; 18054 +|Color Block Length|Set flowing block size; 18055 +|Color Block Spacing|Set the spacing between flow blocks; 18056 +|Display Border|Select display or hide border; 18057 +|Alarm Zone|Set range and color for alarm 18058 +|Display|Set object position and size 18059 +))) 18060 + 18061 +**Tips for designing flow bar** 18062 + 18063 +When user need to simulate the flow of water in a pipe, please put the pipe picture at first, then hide the flow border and place it onto the pipe picture. 18064 + 18065 +* **Video object** 18066 + 18067 +Video object is used for playing the video file provided in the video source. 18068 + 18069 +((( 18070 +|**Items**|**Description** 18071 +|Border color|Set object background color; 18072 +|Color|Set flowing block color; 18073 +|Speed|Three modes for flowing block speed; 18074 +|Flow direction|Two modes for flowing direction; 18075 +|Monitor Point|Set trigger address; 18076 +|Trigger Condition|((( 18077 +Bit address: Select ON or OFF; 18078 + 18079 +Word address: Set value range; 18080 +))) 18081 +|Color Block Width|Set flowing block size; 18082 +|Color Block Length|Set flowing block size; 18083 +|Color Block Spacing|Set the spacing between flow blocks; 18084 +|Display Border|Select display or hide border; 18085 +|Alarm Zone|Set range and color for alarm 18086 +|Display|Set object position and size 18087 +))) 18088 + 18089 +* **Hyperlink** 18090 + 18091 +The object for link website; 18092 + 18093 +((( 18094 +|=**Items**|=**Description** 18095 +|Link address|Enter website; 18096 +|Open with|There are two options, user could select open with new window or current window; 18097 +|Select Language|One object could support three language, user could enter text for note object; 18098 +|Style|Set object display style such as color, use picture as background or not 18099 +|Display|Set object position and size 18100 +))) 18101 + 18102 +* **Function Switch** 18103 + 18104 +Function switch is designed to switch screens, and call and close sub screen. 18105 + 18106 +((( 18107 +|=**Items**|=**Description** 18108 +|Screen|Select the target screen for switch; 18109 +|Sub-screen|There are two options, user could select open with new window or current window; 18110 +|Previous|Switch to the previous screen 18111 +|Next|Switch to the next screen 18112 +|Return|Return to the screen before switch 18113 +|Text|Set text for object, including text font, color direction and so on; 18114 +|Style|Set object display style such as color, use picture as background or not 18115 +|Display|Set object position and size 18116 +))) 18117 + 18118 +* **Combination Switch** 18119 + 18120 +The combination switch supports the collection of multiple functions onto one object. When the object is pressed, multiple functions are arranged in sequence to meet the special requirements of user. 18121 + 18122 +((( 18123 +|=**Items**|=**Description** 18124 +|Bit operation|It provides [Bit copy], [Set ON], [Set OFF], [Switch] and [Bit Copy] functions. 18125 +|Word operation|It provides [Word copy], [Word set], [Increase] and [Decrease] functions, 18126 +|Arithmetic|[Add], [Subtract], [Multiply] and [Divide] functions 18127 +|Screen change|It provides screen switch function as [Function Switch], it supports [Previous], [Next], [Return], [Change to], and open, close sub-screen operations 18128 +|Delete|Delete selected item function; 18129 +|Empty|Delete all items in operation list; 18130 +|Up|Move the selected item up one row in operation list; 18131 +|Down|Move the selected item down one row in operation list; 18132 +))) 18133 + 18134 +**Time** 18135 + 18136 +It is used for displaying the time of the V-BOX, when the V-BOX is offline, the time will stay at the time when it is offline. 18137 + 18138 +((( 18139 +|=**Items**|=**Description** 18140 +|Monitoring box|Link a box for the time part 18141 +|Pattern|Two types, one is digit and the other is clock 18142 +|Format settings|Set format for time and date in digit pattern 18143 +|Background|Set display or hide background of object 18144 +|Set text|Set text display style; 18145 +|Display|Set object position and size 18146 +))) 18147 + 18148 +**Histogram** 18149 + 18150 +It is used for display more than one tag value in Bar graph format. 18151 + 18152 +((( 18153 +|=**Items**|=**Description** 18154 +|Add new group|Maximum is 8, add items for this object, also set colors 18155 +|Add monitoring point|Set read tag for every item, 18156 +|Style|Set object display style such as color, use picture as background or not 18157 +|Display|Set object position and size 18158 +))) 18159 + 18160 +**Alarm record display** 18161 + 18162 +It is used for display alarm information of V-BOX. It can support current and history alarm. 18163 + 18164 +((( 18165 +|=**Items**|=**Description** 18166 +|Select box|Link to V-BOX 18167 +|Alarm type|Select current alarm or history alarm or all 18168 +|Start date|Alarm display start date 18169 +|End date|Alarm display end date 18170 +|Format|Set display format for date and time 18171 +|Sequence|It provides two type, one is order, and the other is reverse order 18172 +|Display content|Users could select display contents by check them 18173 +|Style|Set colors for different parts 18174 +|Display|Set object position and size 18175 +))) 18176 + 18177 +**History trend chart** 18178 + 18179 +The history trend will display data record with graph. X axis represents as time, and Y axis represents as data. 18180 + 18181 +((( 18182 +|=(% colspan="2" %)**Items**|=**Description** 18183 +|(% colspan="2" %)Basic|Set numbers of curve in object and select style for every curves including color, link tag 18184 +|(% rowspan="11" %)Style|Display form|Two type, one is curve, and the other is table 18185 +|Start date|Start date of history data 18186 +|End date|End date of history data 18187 +|Format|Time and date format for display 18188 +|Sequence|Two types, order or reverse order 18189 +|Y range|Two types, fixed and adaptive 18190 +|Set text|Set font size, color and other styles. 18191 +|Transparency|Set transparency of object 18192 +|Background color|Two types, translucent or transparent 18193 +|Gradient way|Set display way and color 18194 +|Display bar|Check it to display screen bar 18195 +|(% colspan="2" %)Display|Set object position and size 18196 +))) 18197 + 18198 +**Indirect screen display** 18199 + 18200 +This object is used for calling screens when condition is met. 18201 + 18202 +((( 18203 +|=(% colspan="2" %)**Items**|=**Description** 18204 +|(% rowspan="4" %)Basic|Conditional trigger|It provides bit, word condition and unconditional 18205 +|Bind monitoring point|Link to tag for triggering 18206 +|Trigger condition|for bit address, it requires ON or OFF, for word address, different value corresponds to different screens. 18207 +|Designated screen|Only for bit address as trigger. When condition is met, display this screen 18208 +|(% colspan="2" %)Style|Set object display style such as display title bar or display or hide background 18209 +|(% colspan="2" %)Display|Set object position and size 18210 +))) 18211 + 18212 +**Ring chart** 18213 + 18214 +Display value as ring chart 18215 + 18216 +((( 18217 +|=(% colspan="2" %)**Items**|=**Description** 18218 +|(% rowspan="7" %)Basic|Monitor point|Link to tag for data reading 18219 +|Range|Set fixed range or variable range 18220 +|Scales|Set scales such as major and minor numbers, colors and so on 18221 +|Designated screen|Only for bit address as trigger. When condition is met, display this screen 18222 +|Numerical scale display|Check it to display scale 18223 +|Start angle|Set start angle for scale 18224 +|Color|Color setting for bar and background 18225 +|(% colspan="2" %)Alarm Zone|Set alarm range and colors 18226 +|(% colspan="2" %)Display|Set object position and size 18227 +))) 18228 + 18229 +**Pie chart** 18230 + 18231 +Display more than one value in one pie chart 18232 + 18233 +((( 18234 +|=(% colspan="2" %)**Items**|=**Description** 18235 +|(% colspan="2" %)Monitor point|Add read addresses, the maximum is 8 18236 +|(% rowspan="3" %)Style|Pattern|Set alarm range and colors 18237 +|Numerical scale|Check it to display value in object 18238 +|Monitoring name display|Check it to display name in object 18239 +|(% colspan="2" %)Display|Set object position and size 18240 +))) 18241 + 18242 +== Common object == 18243 + 18244 +(% style="text-align:center" %) 18245 +[[image:V-BOX cloud configuration user manual_html_c84a5d0032df07e2.png||height="420" width="250" class="img-thumbnail"]] 18246 + 18247 +=== Display frame === 18248 + 18249 +After binding the monitoring point, the data of the monitoring point can be displayed in real time. 18250 + 18251 +|=**Item**|=**Description** 18252 +|Monitoring Point|Set operating address for this object (Read and write can be different); 18253 +|Read-write permission|There are three modes for it, users could select according to requirements; 18254 +|Set Text|It is used for setting style of text and display direction 18255 +|Style|It is used for setting object display, like background color; 18256 +|Expansion|It is used for setting expansion function, like lock position; 18257 +|Display|It is used for setting object position and size 18258 + 18259 +* **Bit /Word Indicator** 18260 + 18261 +Indicator could monitor and display the specified PLC or HMI bit address, and its state changes according to the specified address value. 18262 + 18263 +((( 18264 +|**Items**|**Description** 18265 +|Monitor Point|Set reading address for this object; 18266 +|Status|Set text for every status; 18267 +|Picture|Set picture for every status; 18268 +|Expansion|Set display expansion function, such as blink 18269 +|Display|Set object position and size 18270 +))) 18271 + 18272 +* **Bit/ Word Switch** 18273 + 18274 +Switch could operate the specified PLC or HMI bit address, and its state changes according to the specified address value. 18275 + 18276 +((( 18277 +|**Items**|**Description** 18278 +|Monitor Point|Set operating address for this object (Read and write can be different); 18279 +|Read-write permission|There are three modes for it, users could select according to requirements; 18280 +|Pop up a confirmation box|Check it to enable confirmation box for operating; 18281 +|Status|Set text for every status; 18282 +|Picture|Set picture for every status; 18283 +|Expansion|Set display expansion function, such as blink 18284 +|Display|Set object position and size 18285 +))) 18286 + 18287 +* **Dashboard** 18288 + 18289 +Display the value of address in real time using the dashboard. 18290 + 18291 +((( 18292 +|**Items**|**Description** 18293 +|Monitor Point|Set operating address for this object (Read and write can be different); 18294 +|Select|Set dashboard display range, there are two modes, Constant and Variable 18295 +|Scale value|Check it to display value; 18296 +|Select Language|Set text for object; 18297 +|Style|Set object display style such as color, scales number; 18298 +|Alarm Zone|Set range and color for alarm 18299 +|Display|Set object position and size 18300 +))) 18301 + 18302 +* **Bar graph** 18303 + 18304 +Use the length or height of the rectangle to reflect the value of reading address so that the value could be visualized. 18305 + 18306 +((( 18307 +|**Items**|**Description** 18308 +|Monitor Point|Set operating address for this object (Read and write can be different); 18309 +|Digit Display|Check it to display digit value on bar; 18310 +|Progress bar direction|Select display direction; 18311 +|Scales|Set object scales display type and color; 18312 +|Bar color|Set color for bar; 18313 +|Background Display|Set color of bar background; 18314 +|Alarm Zone|Set range and color for alarm 18315 +|Display|Set object position and size 18316 +))) 18317 + 18318 +* **Real-Time Trend Chart** 18319 + 18320 +Use the curve to show the trend of the data over time. X-axis is time, Y-axis is variable. 18321 + 18322 +((( 18323 +|**Items**|**Description** 18324 +|Monitor Point|Set operating address for this object (Read and write can be different); 18325 +|Digit Display|Check it to display digit value on bar; 18326 +|Progress bar direction|Select display direction; 18327 +|Scales|Set object scales display type and color; 18328 +|Bar color|Set color for bar; 18329 +|Background Display|Set color of bar background; 18330 +|Alarm Zone|Set range and color for alarm 18331 +|Display|Set object position and size 18332 +| | 18333 +))) 18334 + 18335 +* **Flow pipe** 18336 + 18337 +This is a flowing animation object, users could set animation trigger condition for it, the monitor point could be both bit address and word address; 18338 + 18339 +((( 18340 +|**Items**|**Description** 18341 +|Border color|Set object background color; 18342 +|Color|Set flowing block color; 18343 +|Speed|Three modes for flowing block speed; 18344 +|Flow direction|Two modes for flowing direction; 18345 +|Monitor Point|Set trigger address; 18346 +|Trigger Condition|((( 18347 +Bit address: Select ON or OFF; 18348 + 18349 +Word address: Set value range; 18350 +))) 18351 +|Color Block Width|Set flowing block size; 18352 +|Color Block Length|Set flowing block size; 18353 +|Color Block Spacing|Set the spacing between flow blocks; 18354 +|Display Border|Select display or hide border; 18355 +|Alarm Zone|Set range and color for alarm 18356 +|Display|Set object position and size 18357 +))) 18358 + 18359 +**Tips for designing flow bar** 18360 + 18361 +When user need to simulate the flow of water in a pipe, please put the pipe picture at first, then hide the flow border and place it onto the pipe picture. 18362 + 18363 +* **Video object** 18364 + 18365 +Video object is used for playing the video file provided in the video source. 18366 + 18367 +((( 18368 +|**Items**|**Description** 18369 +|Border color|Set object background color; 18370 +|Color|Set flowing block color; 18371 +|Speed|Three modes for flowing block speed; 18372 +|Flow direction|Two modes for flowing direction; 18373 +|Monitor Point|Set trigger address; 18374 +|Trigger Condition|((( 18375 +Bit address: Select ON or OFF; 18376 + 18377 +Word address: Set value range; 18378 +))) 18379 +|Color Block Width|Set flowing block size; 18380 +|Color Block Length|Set flowing block size; 18381 +|Color Block Spacing|Set the spacing between flow blocks; 18382 +|Display Border|Select display or hide border; 18383 +|Alarm Zone|Set range and color for alarm 18384 +|Display|Set object position and size 18385 +))) 18386 + 18387 +* **Hyperlink** 18388 + 18389 +The object for link website; 18390 + 18391 +((( 18392 +|=**Items**|=**Description** 18393 +|Link address|Enter website; 18394 +|Open with|There are two options, user could select open with new window or current window; 18395 +|Select Language|One object could support three language, user could enter text for note object; 18396 +|Style|Set object display style such as color, use picture as background or not 18397 +|Display|Set object position and size 18398 +))) 18399 + 18400 +* **Function Switch** 18401 + 18402 +Function switch is designed to switch screens, and call and close sub screen. 18403 + 18404 +((( 18405 +|=**Items**|=**Description** 18406 +|Screen|Select the target screen for switch; 18407 +|Sub-screen|There are two options, user could select open with new window or current window; 18408 +|Previous|Switch to the previous screen 18409 +|Next|Switch to the next screen 18410 +|Return|Return to the screen before switch 18411 +|Text|Set text for object, including text font, color direction and so on; 18412 +|Style|Set object display style such as color, use picture as background or not 18413 +|Display|Set object position and size 18414 +))) 18415 + 18416 +* **Combination Switch** 18417 + 18418 +The combination switch supports the collection of multiple functions onto one object. When the object is pressed, multiple functions are arranged in sequence to meet the special requirements of user. 18419 + 18420 +((( 18421 +|=**Items**|=**Description** 18422 +|Bit operation|It provides [Bit copy], [Set ON], [Set OFF], [Switch] and [Bit Copy] functions. 18423 +|Word operation|It provides [Word copy], [Word set], [Increase] and [Decrease] functions, 18424 +|Arithmetic|[Add], [Subtract], [Multiply] and [Divide] functions 18425 +|Screen change|It provides screen switch function as [Function Switch], it supports [Previous], [Next], [Return], [Change to], and open, close sub-screen operations 18426 +|Delete|Delete selected item function; 18427 +|Empty|Delete all items in operation list; 18428 +|Up|Move the selected item up one row in operation list; 18429 +|Down|Move the selected item down one row in operation list; 18430 +))) 18431 + 18432 +**Time** 18433 + 18434 +It is used for displaying the time of the V-BOX, when the V-BOX is offline, the time will stay at the time when it is offline. 18435 + 18436 +((( 18437 +|=**Items**|=**Description** 18438 +|Monitoring box|Link a box for the time part 18439 +|Pattern|Two types, one is digit and the other is clock 18440 +|Format settings|Set format for time and date in digit pattern 18441 +|Background|Set display or hide background of object 18442 +|Set text|Set text display style; 18443 +|Display|Set object position and size 18444 +))) 18445 + 18446 +**Histogram** 18447 + 18448 +It is used for display more than one tag value in Bar graph format. 18449 + 18450 +((( 18451 +|=**Items**|=**Description** 18452 +|Add new group|Maximum is 8, add items for this object, also set colors 18453 +|Add monitoring point|Set read tag for every item, 18454 +|Style|Set object display style such as color, use picture as background or not 18455 +|Display|Set object position and size 18456 +))) 18457 + 18458 +**Alarm record display** 18459 + 18460 +It is used for display alarm information of V-BOX. It can support current and history alarm. 18461 + 18462 +((( 18463 +|=**Items**|=**Description** 18464 +|Select box|Link to V-BOX 18465 +|Alarm type|Select current alarm or history alarm or all 18466 +|Start date|Alarm display start date 18467 +|End date|Alarm display end date 18468 +|Format|Set display format for date and time 18469 +|Sequence|It provides two type, one is order, and the other is reverse order 18470 +|Display content|Users could select display contents by check them 18471 +|Style|Set colors for different parts 18472 +|Display|Set object position and size 18473 +))) 18474 + 18475 +**History trend chart** 18476 + 18477 +The history trend will display data record with graph. X axis represents as time, and Y axis represents as data. 18478 + 18479 +((( 18480 +|=(% colspan="2" %)**Items**|=**Description** 18481 +|(% colspan="2" %)Basic|Set numbers of curve in object and select style for every curves including color, link tag 18482 +|(% rowspan="11" %)Style|Display form|Two type, one is curve, and the other is table 18483 +|Start date|Start date of history data 18484 +|End date|End date of history data 18485 +|Format|Time and date format for display 18486 +|Sequence|Two types, order or reverse order 18487 +|Y range|Two types, fixed and adaptive 18488 +|Set text|Set font size, color and other styles. 18489 +|Transparency|Set transparency of object 18490 +|Background color|Two types, translucent or transparent 18491 +|Gradient way|Set display way and color 18492 +|Display bar|Check it to display screen bar 18493 +|(% colspan="2" %)Display|Set object position and size 18494 +))) 18495 + 18496 +**Indirect screen display** 18497 + 18498 +This object is used for calling screens when condition is met. 18499 + 18500 +((( 18501 +|=(% colspan="2" %)**Items**|=**Description** 18502 +|(% rowspan="4" %)Basic|Conditional trigger|It provides bit, word condition and unconditional 18503 +|Bind monitoring point|Link to tag for triggering 18504 +|Trigger condition|for bit address, it requires ON or OFF, for word address, different value corresponds to different screens. 18505 +|Designated screen|Only for bit address as trigger. When condition is met, display this screen 18506 +|(% colspan="2" %)Style|Set object display style such as display title bar or display or hide background 18507 +|(% colspan="2" %)Display|Set object position and size 18508 +))) 18509 + 18510 +**Ring chart** 18511 + 18512 +Display value as ring chart 18513 + 18514 +((( 18515 +|=(% colspan="2" %)**Items**|=**Description** 18516 +|(% rowspan="7" %)Basic|Monitor point|Link to tag for data reading 18517 +|Range|Set fixed range or variable range 18518 +|Scales|Set scales such as major and minor numbers, colors and so on 18519 +|Designated screen|Only for bit address as trigger. When condition is met, display this screen 18520 +|Numerical scale display|Check it to display scale 18521 +|Start angle|Set start angle for scale 18522 +|Color|Color setting for bar and background 18523 +|(% colspan="2" %)Alarm Zone|Set alarm range and colors 18524 +|(% colspan="2" %)Display|Set object position and size 18525 +))) 18526 + 18527 +**Pie chart** 18528 + 18529 +Display more than one value in one pie chart 18530 + 18531 +((( 18532 +|=(% colspan="2" %)**Items**|=**Description** 18533 +|(% colspan="2" %)Monitor point|Add read addresses, the maximum is 8 18534 +|(% rowspan="3" %)Style|Pattern|Set alarm range and colors 18535 +|Numerical scale|Check it to display value in object 18536 +|Monitoring name display|Check it to display name in object 18537 +|(% colspan="2" %)Display|Set object position and size 18538 +))) 18539 + 16752 16752 == **6.5 Tool bar** == 16753 16753 16754 16754 The toolbar has the same function as the tool list. (right-click on the canvas to pop up tool list)