Changes for page 05 Cloud SCADA
Last modified by Joe on 2024/08/08 09:29
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1253,1198 +1253,6 @@ 1253 1253 |(% colspan="2" %)Display|Set object position and size 1254 1254 ))) 1255 1255 1256 -== Common object == 1257 - 1258 -(% style="text-align:center" %) 1259 -[[image:V-BOX cloud configuration user manual_html_c84a5d0032df07e2.png||height="420" width="250" class="img-thumbnail"]] 1260 - 1261 -=== Display frame === 1262 - 1263 -After binding the monitoring point, the data of the monitoring point can be displayed in real time. 1264 - 1265 -|=**Item**|=**Description** 1266 -|Monitoring Point|Set operating address for this object (Read and write can be different); 1267 -|Read-write permission|There are three modes for it, users could select according to requirements; 1268 -|Set Text|It is used for setting style of text and display direction 1269 -|Style|It is used for setting object display, like background color; 1270 -|Expansion|It is used for setting expansion function, like lock position; 1271 -|Display|It is used for setting object position and size 1272 - 1273 -* **Bit /Word Indicator** 1274 - 1275 -Indicator could monitor and display the specified PLC or HMI bit address, and its state changes according to the specified address value. 1276 - 1277 -((( 1278 -|**Items**|**Description** 1279 -|Monitor Point|Set reading address for this object; 1280 -|Status|Set text for every status; 1281 -|Picture|Set picture for every status; 1282 -|Expansion|Set display expansion function, such as blink 1283 -|Display|Set object position and size 1284 -))) 1285 - 1286 -* **Bit/ Word Switch** 1287 - 1288 -Switch could operate the specified PLC or HMI bit address, and its state changes according to the specified address value. 1289 - 1290 -((( 1291 -|**Items**|**Description** 1292 -|Monitor Point|Set operating address for this object (Read and write can be different); 1293 -|Read-write permission|There are three modes for it, users could select according to requirements; 1294 -|Pop up a confirmation box|Check it to enable confirmation box for operating; 1295 -|Status|Set text for every status; 1296 -|Picture|Set picture for every status; 1297 -|Expansion|Set display expansion function, such as blink 1298 -|Display|Set object position and size 1299 -))) 1300 - 1301 -* **Dashboard** 1302 - 1303 -Display the value of address in real time using the dashboard. 1304 - 1305 -((( 1306 -|**Items**|**Description** 1307 -|Monitor Point|Set operating address for this object (Read and write can be different); 1308 -|Select|Set dashboard display range, there are two modes, Constant and Variable 1309 -|Scale value|Check it to display value; 1310 -|Select Language|Set text for object; 1311 -|Style|Set object display style such as color, scales number; 1312 -|Alarm Zone|Set range and color for alarm 1313 -|Display|Set object position and size 1314 -))) 1315 - 1316 -* **Bar graph** 1317 - 1318 -Use the length or height of the rectangle to reflect the value of reading address so that the value could be visualized. 1319 - 1320 -((( 1321 -|**Items**|**Description** 1322 -|Monitor Point|Set operating address for this object (Read and write can be different); 1323 -|Digit Display|Check it to display digit value on bar; 1324 -|Progress bar direction|Select display direction; 1325 -|Scales|Set object scales display type and color; 1326 -|Bar color|Set color for bar; 1327 -|Background Display|Set color of bar background; 1328 -|Alarm Zone|Set range and color for alarm 1329 -|Display|Set object position and size 1330 -))) 1331 - 1332 -* **Real-Time Trend Chart** 1333 - 1334 -Use the curve to show the trend of the data over time. X-axis is time, Y-axis is variable. 1335 - 1336 -((( 1337 -|**Items**|**Description** 1338 -|Monitor Point|Set operating address for this object (Read and write can be different); 1339 -|Digit Display|Check it to display digit value on bar; 1340 -|Progress bar direction|Select display direction; 1341 -|Scales|Set object scales display type and color; 1342 -|Bar color|Set color for bar; 1343 -|Background Display|Set color of bar background; 1344 -|Alarm Zone|Set range and color for alarm 1345 -|Display|Set object position and size 1346 -| | 1347 -))) 1348 - 1349 -* **Flow pipe** 1350 - 1351 -This is a flowing animation object, users could set animation trigger condition for it, the monitor point could be both bit address and word address; 1352 - 1353 -((( 1354 -|**Items**|**Description** 1355 -|Border color|Set object background color; 1356 -|Color|Set flowing block color; 1357 -|Speed|Three modes for flowing block speed; 1358 -|Flow direction|Two modes for flowing direction; 1359 -|Monitor Point|Set trigger address; 1360 -|Trigger Condition|((( 1361 -Bit address: Select ON or OFF; 1362 - 1363 -Word address: Set value range; 1364 -))) 1365 -|Color Block Width|Set flowing block size; 1366 -|Color Block Length|Set flowing block size; 1367 -|Color Block Spacing|Set the spacing between flow blocks; 1368 -|Display Border|Select display or hide border; 1369 -|Alarm Zone|Set range and color for alarm 1370 -|Display|Set object position and size 1371 -))) 1372 - 1373 -**Tips for designing flow bar** 1374 - 1375 -When user need to simulate the flow of water in a pipe, please put the pipe picture at first, then hide the flow border and place it onto the pipe picture. 1376 - 1377 -* **Video object** 1378 - 1379 -Video object is used for playing the video file provided in the video source. 1380 - 1381 -((( 1382 -|**Items**|**Description** 1383 -|Border color|Set object background color; 1384 -|Color|Set flowing block color; 1385 -|Speed|Three modes for flowing block speed; 1386 -|Flow direction|Two modes for flowing direction; 1387 -|Monitor Point|Set trigger address; 1388 -|Trigger Condition|((( 1389 -Bit address: Select ON or OFF; 1390 - 1391 -Word address: Set value range; 1392 -))) 1393 -|Color Block Width|Set flowing block size; 1394 -|Color Block Length|Set flowing block size; 1395 -|Color Block Spacing|Set the spacing between flow blocks; 1396 -|Display Border|Select display or hide border; 1397 -|Alarm Zone|Set range and color for alarm 1398 -|Display|Set object position and size 1399 -))) 1400 - 1401 -* **Hyperlink** 1402 - 1403 -The object for link website; 1404 - 1405 -((( 1406 -|=**Items**|=**Description** 1407 -|Link address|Enter website; 1408 -|Open with|There are two options, user could select open with new window or current window; 1409 -|Select Language|One object could support three language, user could enter text for note object; 1410 -|Style|Set object display style such as color, use picture as background or not 1411 -|Display|Set object position and size 1412 -))) 1413 - 1414 -* **Function Switch** 1415 - 1416 -Function switch is designed to switch screens, and call and close sub screen. 1417 - 1418 -((( 1419 -|=**Items**|=**Description** 1420 -|Screen|Select the target screen for switch; 1421 -|Sub-screen|There are two options, user could select open with new window or current window; 1422 -|Previous|Switch to the previous screen 1423 -|Next|Switch to the next screen 1424 -|Return|Return to the screen before switch 1425 -|Text|Set text for object, including text font, color direction and so on; 1426 -|Style|Set object display style such as color, use picture as background or not 1427 -|Display|Set object position and size 1428 -))) 1429 - 1430 -* **Combination Switch** 1431 - 1432 -The combination switch supports the collection of multiple functions onto one object. When the object is pressed, multiple functions are arranged in sequence to meet the special requirements of user. 1433 - 1434 -((( 1435 -|=**Items**|=**Description** 1436 -|Bit operation|It provides [Bit copy], [Set ON], [Set OFF], [Switch] and [Bit Copy] functions. 1437 -|Word operation|It provides [Word copy], [Word set], [Increase] and [Decrease] functions, 1438 -|Arithmetic|[Add], [Subtract], [Multiply] and [Divide] functions 1439 -|Screen change|It provides screen switch function as [Function Switch], it supports [Previous], [Next], [Return], [Change to], and open, close sub-screen operations 1440 -|Delete|Delete selected item function; 1441 -|Empty|Delete all items in operation list; 1442 -|Up|Move the selected item up one row in operation list; 1443 -|Down|Move the selected item down one row in operation list; 1444 -))) 1445 - 1446 -**Time** 1447 - 1448 -It is used for displaying the time of the V-BOX, when the V-BOX is offline, the time will stay at the time when it is offline. 1449 - 1450 -((( 1451 -|=**Items**|=**Description** 1452 -|Monitoring box|Link a box for the time part 1453 -|Pattern|Two types, one is digit and the other is clock 1454 -|Format settings|Set format for time and date in digit pattern 1455 -|Background|Set display or hide background of object 1456 -|Set text|Set text display style; 1457 -|Display|Set object position and size 1458 -))) 1459 - 1460 -**Histogram** 1461 - 1462 -It is used for display more than one tag value in Bar graph format. 1463 - 1464 -((( 1465 -|=**Items**|=**Description** 1466 -|Add new group|Maximum is 8, add items for this object, also set colors 1467 -|Add monitoring point|Set read tag for every item, 1468 -|Style|Set object display style such as color, use picture as background or not 1469 -|Display|Set object position and size 1470 -))) 1471 - 1472 -**Alarm record display** 1473 - 1474 -It is used for display alarm information of V-BOX. It can support current and history alarm. 1475 - 1476 -((( 1477 -|=**Items**|=**Description** 1478 -|Select box|Link to V-BOX 1479 -|Alarm type|Select current alarm or history alarm or all 1480 -|Start date|Alarm display start date 1481 -|End date|Alarm display end date 1482 -|Format|Set display format for date and time 1483 -|Sequence|It provides two type, one is order, and the other is reverse order 1484 -|Display content|Users could select display contents by check them 1485 -|Style|Set colors for different parts 1486 -|Display|Set object position and size 1487 -))) 1488 - 1489 -**History trend chart** 1490 - 1491 -The history trend will display data record with graph. X axis represents as time, and Y axis represents as data. 1492 - 1493 -((( 1494 -|=(% colspan="2" %)**Items**|=**Description** 1495 -|(% colspan="2" %)Basic|Set numbers of curve in object and select style for every curves including color, link tag 1496 -|(% rowspan="11" %)Style|Display form|Two type, one is curve, and the other is table 1497 -|Start date|Start date of history data 1498 -|End date|End date of history data 1499 -|Format|Time and date format for display 1500 -|Sequence|Two types, order or reverse order 1501 -|Y range|Two types, fixed and adaptive 1502 -|Set text|Set font size, color and other styles. 1503 -|Transparency|Set transparency of object 1504 -|Background color|Two types, translucent or transparent 1505 -|Gradient way|Set display way and color 1506 -|Display bar|Check it to display screen bar 1507 -|(% colspan="2" %)Display|Set object position and size 1508 -))) 1509 - 1510 -**Indirect screen display** 1511 - 1512 -This object is used for calling screens when condition is met. 1513 - 1514 -((( 1515 -|=(% colspan="2" %)**Items**|=**Description** 1516 -|(% rowspan="4" %)Basic|Conditional trigger|It provides bit, word condition and unconditional 1517 -|Bind monitoring point|Link to tag for triggering 1518 -|Trigger condition|for bit address, it requires ON or OFF, for word address, different value corresponds to different screens. 1519 -|Designated screen|Only for bit address as trigger. When condition is met, display this screen 1520 -|(% colspan="2" %)Style|Set object display style such as display title bar or display or hide background 1521 -|(% colspan="2" %)Display|Set object position and size 1522 -))) 1523 - 1524 -**Ring chart** 1525 - 1526 -Display value as ring chart 1527 - 1528 -((( 1529 -|=(% colspan="2" %)**Items**|=**Description** 1530 -|(% rowspan="7" %)Basic|Monitor point|Link to tag for data reading 1531 -|Range|Set fixed range or variable range 1532 -|Scales|Set scales such as major and minor numbers, colors and so on 1533 -|Designated screen|Only for bit address as trigger. When condition is met, display this screen 1534 -|Numerical scale display|Check it to display scale 1535 -|Start angle|Set start angle for scale 1536 -|Color|Color setting for bar and background 1537 -|(% colspan="2" %)Alarm Zone|Set alarm range and colors 1538 -|(% colspan="2" %)Display|Set object position and size 1539 -))) 1540 - 1541 -**Pie chart** 1542 - 1543 -Display more than one value in one pie chart 1544 - 1545 -((( 1546 -|=(% colspan="2" %)**Items**|=**Description** 1547 -|(% colspan="2" %)Monitor point|Add read addresses, the maximum is 8 1548 -|(% rowspan="3" %)Style|Pattern|Set alarm range and colors 1549 -|Numerical scale|Check it to display value in object 1550 -|Monitoring name display|Check it to display name in object 1551 -|(% colspan="2" %)Display|Set object position and size 1552 -))) 1553 - 1554 -== Common object == 1555 - 1556 -(% style="text-align:center" %) 1557 -[[image:V-BOX cloud configuration user manual_html_c84a5d0032df07e2.png||height="420" width="250" class="img-thumbnail"]] 1558 - 1559 -=== Display frame === 1560 - 1561 -After binding the monitoring point, the data of the monitoring point can be displayed in real time. 1562 - 1563 -|=**Item**|=**Description** 1564 -|Monitoring Point|Set operating address for this object (Read and write can be different); 1565 -|Read-write permission|There are three modes for it, users could select according to requirements; 1566 -|Set Text|It is used for setting style of text and display direction 1567 -|Style|It is used for setting object display, like background color; 1568 -|Expansion|It is used for setting expansion function, like lock position; 1569 -|Display|It is used for setting object position and size 1570 - 1571 -* **Bit /Word Indicator** 1572 - 1573 -Indicator could monitor and display the specified PLC or HMI bit address, and its state changes according to the specified address value. 1574 - 1575 -((( 1576 -|**Items**|**Description** 1577 -|Monitor Point|Set reading address for this object; 1578 -|Status|Set text for every status; 1579 -|Picture|Set picture for every status; 1580 -|Expansion|Set display expansion function, such as blink 1581 -|Display|Set object position and size 1582 -))) 1583 - 1584 -* **Bit/ Word Switch** 1585 - 1586 -Switch could operate the specified PLC or HMI bit address, and its state changes according to the specified address value. 1587 - 1588 -((( 1589 -|**Items**|**Description** 1590 -|Monitor Point|Set operating address for this object (Read and write can be different); 1591 -|Read-write permission|There are three modes for it, users could select according to requirements; 1592 -|Pop up a confirmation box|Check it to enable confirmation box for operating; 1593 -|Status|Set text for every status; 1594 -|Picture|Set picture for every status; 1595 -|Expansion|Set display expansion function, such as blink 1596 -|Display|Set object position and size 1597 -))) 1598 - 1599 -* **Dashboard** 1600 - 1601 -Display the value of address in real time using the dashboard. 1602 - 1603 -((( 1604 -|**Items**|**Description** 1605 -|Monitor Point|Set operating address for this object (Read and write can be different); 1606 -|Select|Set dashboard display range, there are two modes, Constant and Variable 1607 -|Scale value|Check it to display value; 1608 -|Select Language|Set text for object; 1609 -|Style|Set object display style such as color, scales number; 1610 -|Alarm Zone|Set range and color for alarm 1611 -|Display|Set object position and size 1612 -))) 1613 - 1614 -* **Bar graph** 1615 - 1616 -Use the length or height of the rectangle to reflect the value of reading address so that the value could be visualized. 1617 - 1618 -((( 1619 -|**Items**|**Description** 1620 -|Monitor Point|Set operating address for this object (Read and write can be different); 1621 -|Digit Display|Check it to display digit value on bar; 1622 -|Progress bar direction|Select display direction; 1623 -|Scales|Set object scales display type and color; 1624 -|Bar color|Set color for bar; 1625 -|Background Display|Set color of bar background; 1626 -|Alarm Zone|Set range and color for alarm 1627 -|Display|Set object position and size 1628 -))) 1629 - 1630 -* **Real-Time Trend Chart** 1631 - 1632 -Use the curve to show the trend of the data over time. X-axis is time, Y-axis is variable. 1633 - 1634 -((( 1635 -|**Items**|**Description** 1636 -|Monitor Point|Set operating address for this object (Read and write can be different); 1637 -|Digit Display|Check it to display digit value on bar; 1638 -|Progress bar direction|Select display direction; 1639 -|Scales|Set object scales display type and color; 1640 -|Bar color|Set color for bar; 1641 -|Background Display|Set color of bar background; 1642 -|Alarm Zone|Set range and color for alarm 1643 -|Display|Set object position and size 1644 -| | 1645 -))) 1646 - 1647 -* **Flow pipe** 1648 - 1649 -This is a flowing animation object, users could set animation trigger condition for it, the monitor point could be both bit address and word address; 1650 - 1651 -((( 1652 -|**Items**|**Description** 1653 -|Border color|Set object background color; 1654 -|Color|Set flowing block color; 1655 -|Speed|Three modes for flowing block speed; 1656 -|Flow direction|Two modes for flowing direction; 1657 -|Monitor Point|Set trigger address; 1658 -|Trigger Condition|((( 1659 -Bit address: Select ON or OFF; 1660 - 1661 -Word address: Set value range; 1662 -))) 1663 -|Color Block Width|Set flowing block size; 1664 -|Color Block Length|Set flowing block size; 1665 -|Color Block Spacing|Set the spacing between flow blocks; 1666 -|Display Border|Select display or hide border; 1667 -|Alarm Zone|Set range and color for alarm 1668 -|Display|Set object position and size 1669 -))) 1670 - 1671 -**Tips for designing flow bar** 1672 - 1673 -When user need to simulate the flow of water in a pipe, please put the pipe picture at first, then hide the flow border and place it onto the pipe picture. 1674 - 1675 -* **Video object** 1676 - 1677 -Video object is used for playing the video file provided in the video source. 1678 - 1679 -((( 1680 -|**Items**|**Description** 1681 -|Border color|Set object background color; 1682 -|Color|Set flowing block color; 1683 -|Speed|Three modes for flowing block speed; 1684 -|Flow direction|Two modes for flowing direction; 1685 -|Monitor Point|Set trigger address; 1686 -|Trigger Condition|((( 1687 -Bit address: Select ON or OFF; 1688 - 1689 -Word address: Set value range; 1690 -))) 1691 -|Color Block Width|Set flowing block size; 1692 -|Color Block Length|Set flowing block size; 1693 -|Color Block Spacing|Set the spacing between flow blocks; 1694 -|Display Border|Select display or hide border; 1695 -|Alarm Zone|Set range and color for alarm 1696 -|Display|Set object position and size 1697 -))) 1698 - 1699 -* **Hyperlink** 1700 - 1701 -The object for link website; 1702 - 1703 -((( 1704 -|=**Items**|=**Description** 1705 -|Link address|Enter website; 1706 -|Open with|There are two options, user could select open with new window or current window; 1707 -|Select Language|One object could support three language, user could enter text for note object; 1708 -|Style|Set object display style such as color, use picture as background or not 1709 -|Display|Set object position and size 1710 -))) 1711 - 1712 -* **Function Switch** 1713 - 1714 -Function switch is designed to switch screens, and call and close sub screen. 1715 - 1716 -((( 1717 -|=**Items**|=**Description** 1718 -|Screen|Select the target screen for switch; 1719 -|Sub-screen|There are two options, user could select open with new window or current window; 1720 -|Previous|Switch to the previous screen 1721 -|Next|Switch to the next screen 1722 -|Return|Return to the screen before switch 1723 -|Text|Set text for object, including text font, color direction and so on; 1724 -|Style|Set object display style such as color, use picture as background or not 1725 -|Display|Set object position and size 1726 -))) 1727 - 1728 -* **Combination Switch** 1729 - 1730 -The combination switch supports the collection of multiple functions onto one object. When the object is pressed, multiple functions are arranged in sequence to meet the special requirements of user. 1731 - 1732 -((( 1733 -|=**Items**|=**Description** 1734 -|Bit operation|It provides [Bit copy], [Set ON], [Set OFF], [Switch] and [Bit Copy] functions. 1735 -|Word operation|It provides [Word copy], [Word set], [Increase] and [Decrease] functions, 1736 -|Arithmetic|[Add], [Subtract], [Multiply] and [Divide] functions 1737 -|Screen change|It provides screen switch function as [Function Switch], it supports [Previous], [Next], [Return], [Change to], and open, close sub-screen operations 1738 -|Delete|Delete selected item function; 1739 -|Empty|Delete all items in operation list; 1740 -|Up|Move the selected item up one row in operation list; 1741 -|Down|Move the selected item down one row in operation list; 1742 -))) 1743 - 1744 -**Time** 1745 - 1746 -It is used for displaying the time of the V-BOX, when the V-BOX is offline, the time will stay at the time when it is offline. 1747 - 1748 -((( 1749 -|=**Items**|=**Description** 1750 -|Monitoring box|Link a box for the time part 1751 -|Pattern|Two types, one is digit and the other is clock 1752 -|Format settings|Set format for time and date in digit pattern 1753 -|Background|Set display or hide background of object 1754 -|Set text|Set text display style; 1755 -|Display|Set object position and size 1756 -))) 1757 - 1758 -**Histogram** 1759 - 1760 -It is used for display more than one tag value in Bar graph format. 1761 - 1762 -((( 1763 -|=**Items**|=**Description** 1764 -|Add new group|Maximum is 8, add items for this object, also set colors 1765 -|Add monitoring point|Set read tag for every item, 1766 -|Style|Set object display style such as color, use picture as background or not 1767 -|Display|Set object position and size 1768 -))) 1769 - 1770 -**Alarm record display** 1771 - 1772 -It is used for display alarm information of V-BOX. It can support current and history alarm. 1773 - 1774 -((( 1775 -|=**Items**|=**Description** 1776 -|Select box|Link to V-BOX 1777 -|Alarm type|Select current alarm or history alarm or all 1778 -|Start date|Alarm display start date 1779 -|End date|Alarm display end date 1780 -|Format|Set display format for date and time 1781 -|Sequence|It provides two type, one is order, and the other is reverse order 1782 -|Display content|Users could select display contents by check them 1783 -|Style|Set colors for different parts 1784 -|Display|Set object position and size 1785 -))) 1786 - 1787 -**History trend chart** 1788 - 1789 -The history trend will display data record with graph. X axis represents as time, and Y axis represents as data. 1790 - 1791 -((( 1792 -|=(% colspan="2" %)**Items**|=**Description** 1793 -|(% colspan="2" %)Basic|Set numbers of curve in object and select style for every curves including color, link tag 1794 -|(% rowspan="11" %)Style|Display form|Two type, one is curve, and the other is table 1795 -|Start date|Start date of history data 1796 -|End date|End date of history data 1797 -|Format|Time and date format for display 1798 -|Sequence|Two types, order or reverse order 1799 -|Y range|Two types, fixed and adaptive 1800 -|Set text|Set font size, color and other styles. 1801 -|Transparency|Set transparency of object 1802 -|Background color|Two types, translucent or transparent 1803 -|Gradient way|Set display way and color 1804 -|Display bar|Check it to display screen bar 1805 -|(% colspan="2" %)Display|Set object position and size 1806 -))) 1807 - 1808 -**Indirect screen display** 1809 - 1810 -This object is used for calling screens when condition is met. 1811 - 1812 -((( 1813 -|=(% colspan="2" %)**Items**|=**Description** 1814 -|(% rowspan="4" %)Basic|Conditional trigger|It provides bit, word condition and unconditional 1815 -|Bind monitoring point|Link to tag for triggering 1816 -|Trigger condition|for bit address, it requires ON or OFF, for word address, different value corresponds to different screens. 1817 -|Designated screen|Only for bit address as trigger. When condition is met, display this screen 1818 -|(% colspan="2" %)Style|Set object display style such as display title bar or display or hide background 1819 -|(% colspan="2" %)Display|Set object position and size 1820 -))) 1821 - 1822 -**Ring chart** 1823 - 1824 -Display value as ring chart 1825 - 1826 -((( 1827 -|=(% colspan="2" %)**Items**|=**Description** 1828 -|(% rowspan="7" %)Basic|Monitor point|Link to tag for data reading 1829 -|Range|Set fixed range or variable range 1830 -|Scales|Set scales such as major and minor numbers, colors and so on 1831 -|Designated screen|Only for bit address as trigger. When condition is met, display this screen 1832 -|Numerical scale display|Check it to display scale 1833 -|Start angle|Set start angle for scale 1834 -|Color|Color setting for bar and background 1835 -|(% colspan="2" %)Alarm Zone|Set alarm range and colors 1836 -|(% colspan="2" %)Display|Set object position and size 1837 -))) 1838 - 1839 -**Pie chart** 1840 - 1841 -Display more than one value in one pie chart 1842 - 1843 -((( 1844 -|=(% colspan="2" %)**Items**|=**Description** 1845 -|(% colspan="2" %)Monitor point|Add read addresses, the maximum is 8 1846 -|(% rowspan="3" %)Style|Pattern|Set alarm range and colors 1847 -|Numerical scale|Check it to display value in object 1848 -|Monitoring name display|Check it to display name in object 1849 -|(% colspan="2" %)Display|Set object position and size 1850 -))) 1851 - 1852 -== Common object == 1853 - 1854 -(% style="text-align:center" %) 1855 -[[image:V-BOX cloud configuration user manual_html_c84a5d0032df07e2.png||height="420" width="250" class="img-thumbnail"]] 1856 - 1857 -=== Display frame === 1858 - 1859 -After binding the monitoring point, the data of the monitoring point can be displayed in real time. 1860 - 1861 -|=**Item**|=**Description** 1862 -|Monitoring Point|Set operating address for this object (Read and write can be different); 1863 -|Read-write permission|There are three modes for it, users could select according to requirements; 1864 -|Set Text|It is used for setting style of text and display direction 1865 -|Style|It is used for setting object display, like background color; 1866 -|Expansion|It is used for setting expansion function, like lock position; 1867 -|Display|It is used for setting object position and size 1868 - 1869 -* **Bit /Word Indicator** 1870 - 1871 -Indicator could monitor and display the specified PLC or HMI bit address, and its state changes according to the specified address value. 1872 - 1873 -((( 1874 -|**Items**|**Description** 1875 -|Monitor Point|Set reading address for this object; 1876 -|Status|Set text for every status; 1877 -|Picture|Set picture for every status; 1878 -|Expansion|Set display expansion function, such as blink 1879 -|Display|Set object position and size 1880 -))) 1881 - 1882 -* **Bit/ Word Switch** 1883 - 1884 -Switch could operate the specified PLC or HMI bit address, and its state changes according to the specified address value. 1885 - 1886 -((( 1887 -|**Items**|**Description** 1888 -|Monitor Point|Set operating address for this object (Read and write can be different); 1889 -|Read-write permission|There are three modes for it, users could select according to requirements; 1890 -|Pop up a confirmation box|Check it to enable confirmation box for operating; 1891 -|Status|Set text for every status; 1892 -|Picture|Set picture for every status; 1893 -|Expansion|Set display expansion function, such as blink 1894 -|Display|Set object position and size 1895 -))) 1896 - 1897 -* **Dashboard** 1898 - 1899 -Display the value of address in real time using the dashboard. 1900 - 1901 -((( 1902 -|**Items**|**Description** 1903 -|Monitor Point|Set operating address for this object (Read and write can be different); 1904 -|Select|Set dashboard display range, there are two modes, Constant and Variable 1905 -|Scale value|Check it to display value; 1906 -|Select Language|Set text for object; 1907 -|Style|Set object display style such as color, scales number; 1908 -|Alarm Zone|Set range and color for alarm 1909 -|Display|Set object position and size 1910 -))) 1911 - 1912 -* **Bar graph** 1913 - 1914 -Use the length or height of the rectangle to reflect the value of reading address so that the value could be visualized. 1915 - 1916 -((( 1917 -|**Items**|**Description** 1918 -|Monitor Point|Set operating address for this object (Read and write can be different); 1919 -|Digit Display|Check it to display digit value on bar; 1920 -|Progress bar direction|Select display direction; 1921 -|Scales|Set object scales display type and color; 1922 -|Bar color|Set color for bar; 1923 -|Background Display|Set color of bar background; 1924 -|Alarm Zone|Set range and color for alarm 1925 -|Display|Set object position and size 1926 -))) 1927 - 1928 -* **Real-Time Trend Chart** 1929 - 1930 -Use the curve to show the trend of the data over time. X-axis is time, Y-axis is variable. 1931 - 1932 -((( 1933 -|**Items**|**Description** 1934 -|Monitor Point|Set operating address for this object (Read and write can be different); 1935 -|Digit Display|Check it to display digit value on bar; 1936 -|Progress bar direction|Select display direction; 1937 -|Scales|Set object scales display type and color; 1938 -|Bar color|Set color for bar; 1939 -|Background Display|Set color of bar background; 1940 -|Alarm Zone|Set range and color for alarm 1941 -|Display|Set object position and size 1942 -| | 1943 -))) 1944 - 1945 -* **Flow pipe** 1946 - 1947 -This is a flowing animation object, users could set animation trigger condition for it, the monitor point could be both bit address and word address; 1948 - 1949 -((( 1950 -|**Items**|**Description** 1951 -|Border color|Set object background color; 1952 -|Color|Set flowing block color; 1953 -|Speed|Three modes for flowing block speed; 1954 -|Flow direction|Two modes for flowing direction; 1955 -|Monitor Point|Set trigger address; 1956 -|Trigger Condition|((( 1957 -Bit address: Select ON or OFF; 1958 - 1959 -Word address: Set value range; 1960 -))) 1961 -|Color Block Width|Set flowing block size; 1962 -|Color Block Length|Set flowing block size; 1963 -|Color Block Spacing|Set the spacing between flow blocks; 1964 -|Display Border|Select display or hide border; 1965 -|Alarm Zone|Set range and color for alarm 1966 -|Display|Set object position and size 1967 -))) 1968 - 1969 -**Tips for designing flow bar** 1970 - 1971 -When user need to simulate the flow of water in a pipe, please put the pipe picture at first, then hide the flow border and place it onto the pipe picture. 1972 - 1973 -* **Video object** 1974 - 1975 -Video object is used for playing the video file provided in the video source. 1976 - 1977 -((( 1978 -|**Items**|**Description** 1979 -|Border color|Set object background color; 1980 -|Color|Set flowing block color; 1981 -|Speed|Three modes for flowing block speed; 1982 -|Flow direction|Two modes for flowing direction; 1983 -|Monitor Point|Set trigger address; 1984 -|Trigger Condition|((( 1985 -Bit address: Select ON or OFF; 1986 - 1987 -Word address: Set value range; 1988 -))) 1989 -|Color Block Width|Set flowing block size; 1990 -|Color Block Length|Set flowing block size; 1991 -|Color Block Spacing|Set the spacing between flow blocks; 1992 -|Display Border|Select display or hide border; 1993 -|Alarm Zone|Set range and color for alarm 1994 -|Display|Set object position and size 1995 -))) 1996 - 1997 -* **Hyperlink** 1998 - 1999 -The object for link website; 2000 - 2001 -((( 2002 -|=**Items**|=**Description** 2003 -|Link address|Enter website; 2004 -|Open with|There are two options, user could select open with new window or current window; 2005 -|Select Language|One object could support three language, user could enter text for note object; 2006 -|Style|Set object display style such as color, use picture as background or not 2007 -|Display|Set object position and size 2008 -))) 2009 - 2010 -* **Function Switch** 2011 - 2012 -Function switch is designed to switch screens, and call and close sub screen. 2013 - 2014 -((( 2015 -|=**Items**|=**Description** 2016 -|Screen|Select the target screen for switch; 2017 -|Sub-screen|There are two options, user could select open with new window or current window; 2018 -|Previous|Switch to the previous screen 2019 -|Next|Switch to the next screen 2020 -|Return|Return to the screen before switch 2021 -|Text|Set text for object, including text font, color direction and so on; 2022 -|Style|Set object display style such as color, use picture as background or not 2023 -|Display|Set object position and size 2024 -))) 2025 - 2026 -* **Combination Switch** 2027 - 2028 -The combination switch supports the collection of multiple functions onto one object. When the object is pressed, multiple functions are arranged in sequence to meet the special requirements of user. 2029 - 2030 -((( 2031 -|=**Items**|=**Description** 2032 -|Bit operation|It provides [Bit copy], [Set ON], [Set OFF], [Switch] and [Bit Copy] functions. 2033 -|Word operation|It provides [Word copy], [Word set], [Increase] and [Decrease] functions, 2034 -|Arithmetic|[Add], [Subtract], [Multiply] and [Divide] functions 2035 -|Screen change|It provides screen switch function as [Function Switch], it supports [Previous], [Next], [Return], [Change to], and open, close sub-screen operations 2036 -|Delete|Delete selected item function; 2037 -|Empty|Delete all items in operation list; 2038 -|Up|Move the selected item up one row in operation list; 2039 -|Down|Move the selected item down one row in operation list; 2040 -))) 2041 - 2042 -**Time** 2043 - 2044 -It is used for displaying the time of the V-BOX, when the V-BOX is offline, the time will stay at the time when it is offline. 2045 - 2046 -((( 2047 -|=**Items**|=**Description** 2048 -|Monitoring box|Link a box for the time part 2049 -|Pattern|Two types, one is digit and the other is clock 2050 -|Format settings|Set format for time and date in digit pattern 2051 -|Background|Set display or hide background of object 2052 -|Set text|Set text display style; 2053 -|Display|Set object position and size 2054 -))) 2055 - 2056 -**Histogram** 2057 - 2058 -It is used for display more than one tag value in Bar graph format. 2059 - 2060 -((( 2061 -|=**Items**|=**Description** 2062 -|Add new group|Maximum is 8, add items for this object, also set colors 2063 -|Add monitoring point|Set read tag for every item, 2064 -|Style|Set object display style such as color, use picture as background or not 2065 -|Display|Set object position and size 2066 -))) 2067 - 2068 -**Alarm record display** 2069 - 2070 -It is used for display alarm information of V-BOX. It can support current and history alarm. 2071 - 2072 -((( 2073 -|=**Items**|=**Description** 2074 -|Select box|Link to V-BOX 2075 -|Alarm type|Select current alarm or history alarm or all 2076 -|Start date|Alarm display start date 2077 -|End date|Alarm display end date 2078 -|Format|Set display format for date and time 2079 -|Sequence|It provides two type, one is order, and the other is reverse order 2080 -|Display content|Users could select display contents by check them 2081 -|Style|Set colors for different parts 2082 -|Display|Set object position and size 2083 -))) 2084 - 2085 -**History trend chart** 2086 - 2087 -The history trend will display data record with graph. X axis represents as time, and Y axis represents as data. 2088 - 2089 -((( 2090 -|=(% colspan="2" %)**Items**|=**Description** 2091 -|(% colspan="2" %)Basic|Set numbers of curve in object and select style for every curves including color, link tag 2092 -|(% rowspan="11" %)Style|Display form|Two type, one is curve, and the other is table 2093 -|Start date|Start date of history data 2094 -|End date|End date of history data 2095 -|Format|Time and date format for display 2096 -|Sequence|Two types, order or reverse order 2097 -|Y range|Two types, fixed and adaptive 2098 -|Set text|Set font size, color and other styles. 2099 -|Transparency|Set transparency of object 2100 -|Background color|Two types, translucent or transparent 2101 -|Gradient way|Set display way and color 2102 -|Display bar|Check it to display screen bar 2103 -|(% colspan="2" %)Display|Set object position and size 2104 -))) 2105 - 2106 -**Indirect screen display** 2107 - 2108 -This object is used for calling screens when condition is met. 2109 - 2110 -((( 2111 -|=(% colspan="2" %)**Items**|=**Description** 2112 -|(% rowspan="4" %)Basic|Conditional trigger|It provides bit, word condition and unconditional 2113 -|Bind monitoring point|Link to tag for triggering 2114 -|Trigger condition|for bit address, it requires ON or OFF, for word address, different value corresponds to different screens. 2115 -|Designated screen|Only for bit address as trigger. When condition is met, display this screen 2116 -|(% colspan="2" %)Style|Set object display style such as display title bar or display or hide background 2117 -|(% colspan="2" %)Display|Set object position and size 2118 -))) 2119 - 2120 -**Ring chart** 2121 - 2122 -Display value as ring chart 2123 - 2124 -((( 2125 -|=(% colspan="2" %)**Items**|=**Description** 2126 -|(% rowspan="7" %)Basic|Monitor point|Link to tag for data reading 2127 -|Range|Set fixed range or variable range 2128 -|Scales|Set scales such as major and minor numbers, colors and so on 2129 -|Designated screen|Only for bit address as trigger. When condition is met, display this screen 2130 -|Numerical scale display|Check it to display scale 2131 -|Start angle|Set start angle for scale 2132 -|Color|Color setting for bar and background 2133 -|(% colspan="2" %)Alarm Zone|Set alarm range and colors 2134 -|(% colspan="2" %)Display|Set object position and size 2135 -))) 2136 - 2137 -**Pie chart** 2138 - 2139 -Display more than one value in one pie chart 2140 - 2141 -((( 2142 -|=(% colspan="2" %)**Items**|=**Description** 2143 -|(% colspan="2" %)Monitor point|Add read addresses, the maximum is 8 2144 -|(% rowspan="3" %)Style|Pattern|Set alarm range and colors 2145 -|Numerical scale|Check it to display value in object 2146 -|Monitoring name display|Check it to display name in object 2147 -|(% colspan="2" %)Display|Set object position and size 2148 -))) 2149 - 2150 -== Common object == 2151 - 2152 -(% style="text-align:center" %) 2153 -[[image:V-BOX cloud configuration user manual_html_c84a5d0032df07e2.png||height="420" width="250" class="img-thumbnail"]] 2154 - 2155 -=== Display frame === 2156 - 2157 -After binding the monitoring point, the data of the monitoring point can be displayed in real time. 2158 - 2159 -|=**Item**|=**Description** 2160 -|Monitoring Point|Set operating address for this object (Read and write can be different); 2161 -|Read-write permission|There are three modes for it, users could select according to requirements; 2162 -|Set Text|It is used for setting style of text and display direction 2163 -|Style|It is used for setting object display, like background color; 2164 -|Expansion|It is used for setting expansion function, like lock position; 2165 -|Display|It is used for setting object position and size 2166 - 2167 -* **Bit /Word Indicator** 2168 - 2169 -Indicator could monitor and display the specified PLC or HMI bit address, and its state changes according to the specified address value. 2170 - 2171 -((( 2172 -|**Items**|**Description** 2173 -|Monitor Point|Set reading address for this object; 2174 -|Status|Set text for every status; 2175 -|Picture|Set picture for every status; 2176 -|Expansion|Set display expansion function, such as blink 2177 -|Display|Set object position and size 2178 -))) 2179 - 2180 -* **Bit/ Word Switch** 2181 - 2182 -Switch could operate the specified PLC or HMI bit address, and its state changes according to the specified address value. 2183 - 2184 -((( 2185 -|**Items**|**Description** 2186 -|Monitor Point|Set operating address for this object (Read and write can be different); 2187 -|Read-write permission|There are three modes for it, users could select according to requirements; 2188 -|Pop up a confirmation box|Check it to enable confirmation box for operating; 2189 -|Status|Set text for every status; 2190 -|Picture|Set picture for every status; 2191 -|Expansion|Set display expansion function, such as blink 2192 -|Display|Set object position and size 2193 -))) 2194 - 2195 -* **Dashboard** 2196 - 2197 -Display the value of address in real time using the dashboard. 2198 - 2199 -((( 2200 -|**Items**|**Description** 2201 -|Monitor Point|Set operating address for this object (Read and write can be different); 2202 -|Select|Set dashboard display range, there are two modes, Constant and Variable 2203 -|Scale value|Check it to display value; 2204 -|Select Language|Set text for object; 2205 -|Style|Set object display style such as color, scales number; 2206 -|Alarm Zone|Set range and color for alarm 2207 -|Display|Set object position and size 2208 -))) 2209 - 2210 -* **Bar graph** 2211 - 2212 -Use the length or height of the rectangle to reflect the value of reading address so that the value could be visualized. 2213 - 2214 -((( 2215 -|**Items**|**Description** 2216 -|Monitor Point|Set operating address for this object (Read and write can be different); 2217 -|Digit Display|Check it to display digit value on bar; 2218 -|Progress bar direction|Select display direction; 2219 -|Scales|Set object scales display type and color; 2220 -|Bar color|Set color for bar; 2221 -|Background Display|Set color of bar background; 2222 -|Alarm Zone|Set range and color for alarm 2223 -|Display|Set object position and size 2224 -))) 2225 - 2226 -* **Real-Time Trend Chart** 2227 - 2228 -Use the curve to show the trend of the data over time. X-axis is time, Y-axis is variable. 2229 - 2230 -((( 2231 -|**Items**|**Description** 2232 -|Monitor Point|Set operating address for this object (Read and write can be different); 2233 -|Digit Display|Check it to display digit value on bar; 2234 -|Progress bar direction|Select display direction; 2235 -|Scales|Set object scales display type and color; 2236 -|Bar color|Set color for bar; 2237 -|Background Display|Set color of bar background; 2238 -|Alarm Zone|Set range and color for alarm 2239 -|Display|Set object position and size 2240 -| | 2241 -))) 2242 - 2243 -* **Flow pipe** 2244 - 2245 -This is a flowing animation object, users could set animation trigger condition for it, the monitor point could be both bit address and word address; 2246 - 2247 -((( 2248 -|**Items**|**Description** 2249 -|Border color|Set object background color; 2250 -|Color|Set flowing block color; 2251 -|Speed|Three modes for flowing block speed; 2252 -|Flow direction|Two modes for flowing direction; 2253 -|Monitor Point|Set trigger address; 2254 -|Trigger Condition|((( 2255 -Bit address: Select ON or OFF; 2256 - 2257 -Word address: Set value range; 2258 -))) 2259 -|Color Block Width|Set flowing block size; 2260 -|Color Block Length|Set flowing block size; 2261 -|Color Block Spacing|Set the spacing between flow blocks; 2262 -|Display Border|Select display or hide border; 2263 -|Alarm Zone|Set range and color for alarm 2264 -|Display|Set object position and size 2265 -))) 2266 - 2267 -**Tips for designing flow bar** 2268 - 2269 -When user need to simulate the flow of water in a pipe, please put the pipe picture at first, then hide the flow border and place it onto the pipe picture. 2270 - 2271 -* **Video object** 2272 - 2273 -Video object is used for playing the video file provided in the video source. 2274 - 2275 -((( 2276 -|**Items**|**Description** 2277 -|Border color|Set object background color; 2278 -|Color|Set flowing block color; 2279 -|Speed|Three modes for flowing block speed; 2280 -|Flow direction|Two modes for flowing direction; 2281 -|Monitor Point|Set trigger address; 2282 -|Trigger Condition|((( 2283 -Bit address: Select ON or OFF; 2284 - 2285 -Word address: Set value range; 2286 -))) 2287 -|Color Block Width|Set flowing block size; 2288 -|Color Block Length|Set flowing block size; 2289 -|Color Block Spacing|Set the spacing between flow blocks; 2290 -|Display Border|Select display or hide border; 2291 -|Alarm Zone|Set range and color for alarm 2292 -|Display|Set object position and size 2293 -))) 2294 - 2295 -* **Hyperlink** 2296 - 2297 -The object for link website; 2298 - 2299 -((( 2300 -|=**Items**|=**Description** 2301 -|Link address|Enter website; 2302 -|Open with|There are two options, user could select open with new window or current window; 2303 -|Select Language|One object could support three language, user could enter text for note object; 2304 -|Style|Set object display style such as color, use picture as background or not 2305 -|Display|Set object position and size 2306 -))) 2307 - 2308 -* **Function Switch** 2309 - 2310 -Function switch is designed to switch screens, and call and close sub screen. 2311 - 2312 -((( 2313 -|=**Items**|=**Description** 2314 -|Screen|Select the target screen for switch; 2315 -|Sub-screen|There are two options, user could select open with new window or current window; 2316 -|Previous|Switch to the previous screen 2317 -|Next|Switch to the next screen 2318 -|Return|Return to the screen before switch 2319 -|Text|Set text for object, including text font, color direction and so on; 2320 -|Style|Set object display style such as color, use picture as background or not 2321 -|Display|Set object position and size 2322 -))) 2323 - 2324 -* **Combination Switch** 2325 - 2326 -The combination switch supports the collection of multiple functions onto one object. When the object is pressed, multiple functions are arranged in sequence to meet the special requirements of user. 2327 - 2328 -((( 2329 -|=**Items**|=**Description** 2330 -|Bit operation|It provides [Bit copy], [Set ON], [Set OFF], [Switch] and [Bit Copy] functions. 2331 -|Word operation|It provides [Word copy], [Word set], [Increase] and [Decrease] functions, 2332 -|Arithmetic|[Add], [Subtract], [Multiply] and [Divide] functions 2333 -|Screen change|It provides screen switch function as [Function Switch], it supports [Previous], [Next], [Return], [Change to], and open, close sub-screen operations 2334 -|Delete|Delete selected item function; 2335 -|Empty|Delete all items in operation list; 2336 -|Up|Move the selected item up one row in operation list; 2337 -|Down|Move the selected item down one row in operation list; 2338 -))) 2339 - 2340 -**Time** 2341 - 2342 -It is used for displaying the time of the V-BOX, when the V-BOX is offline, the time will stay at the time when it is offline. 2343 - 2344 -((( 2345 -|=**Items**|=**Description** 2346 -|Monitoring box|Link a box for the time part 2347 -|Pattern|Two types, one is digit and the other is clock 2348 -|Format settings|Set format for time and date in digit pattern 2349 -|Background|Set display or hide background of object 2350 -|Set text|Set text display style; 2351 -|Display|Set object position and size 2352 -))) 2353 - 2354 -**Histogram** 2355 - 2356 -It is used for display more than one tag value in Bar graph format. 2357 - 2358 -((( 2359 -|=**Items**|=**Description** 2360 -|Add new group|Maximum is 8, add items for this object, also set colors 2361 -|Add monitoring point|Set read tag for every item, 2362 -|Style|Set object display style such as color, use picture as background or not 2363 -|Display|Set object position and size 2364 -))) 2365 - 2366 -**Alarm record display** 2367 - 2368 -It is used for display alarm information of V-BOX. It can support current and history alarm. 2369 - 2370 -((( 2371 -|=**Items**|=**Description** 2372 -|Select box|Link to V-BOX 2373 -|Alarm type|Select current alarm or history alarm or all 2374 -|Start date|Alarm display start date 2375 -|End date|Alarm display end date 2376 -|Format|Set display format for date and time 2377 -|Sequence|It provides two type, one is order, and the other is reverse order 2378 -|Display content|Users could select display contents by check them 2379 -|Style|Set colors for different parts 2380 -|Display|Set object position and size 2381 -))) 2382 - 2383 -**History trend chart** 2384 - 2385 -The history trend will display data record with graph. X axis represents as time, and Y axis represents as data. 2386 - 2387 -((( 2388 -|=(% colspan="2" %)**Items**|=**Description** 2389 -|(% colspan="2" %)Basic|Set numbers of curve in object and select style for every curves including color, link tag 2390 -|(% rowspan="11" %)Style|Display form|Two type, one is curve, and the other is table 2391 -|Start date|Start date of history data 2392 -|End date|End date of history data 2393 -|Format|Time and date format for display 2394 -|Sequence|Two types, order or reverse order 2395 -|Y range|Two types, fixed and adaptive 2396 -|Set text|Set font size, color and other styles. 2397 -|Transparency|Set transparency of object 2398 -|Background color|Two types, translucent or transparent 2399 -|Gradient way|Set display way and color 2400 -|Display bar|Check it to display screen bar 2401 -|(% colspan="2" %)Display|Set object position and size 2402 -))) 2403 - 2404 -**Indirect screen display** 2405 - 2406 -This object is used for calling screens when condition is met. 2407 - 2408 -((( 2409 -|=(% colspan="2" %)**Items**|=**Description** 2410 -|(% rowspan="4" %)Basic|Conditional trigger|It provides bit, word condition and unconditional 2411 -|Bind monitoring point|Link to tag for triggering 2412 -|Trigger condition|for bit address, it requires ON or OFF, for word address, different value corresponds to different screens. 2413 -|Designated screen|Only for bit address as trigger. When condition is met, display this screen 2414 -|(% colspan="2" %)Style|Set object display style such as display title bar or display or hide background 2415 -|(% colspan="2" %)Display|Set object position and size 2416 -))) 2417 - 2418 -**Ring chart** 2419 - 2420 -Display value as ring chart 2421 - 2422 -((( 2423 -|=(% colspan="2" %)**Items**|=**Description** 2424 -|(% rowspan="7" %)Basic|Monitor point|Link to tag for data reading 2425 -|Range|Set fixed range or variable range 2426 -|Scales|Set scales such as major and minor numbers, colors and so on 2427 -|Designated screen|Only for bit address as trigger. When condition is met, display this screen 2428 -|Numerical scale display|Check it to display scale 2429 -|Start angle|Set start angle for scale 2430 -|Color|Color setting for bar and background 2431 -|(% colspan="2" %)Alarm Zone|Set alarm range and colors 2432 -|(% colspan="2" %)Display|Set object position and size 2433 -))) 2434 - 2435 -**Pie chart** 2436 - 2437 -Display more than one value in one pie chart 2438 - 2439 -((( 2440 -|=(% colspan="2" %)**Items**|=**Description** 2441 -|(% colspan="2" %)Monitor point|Add read addresses, the maximum is 8 2442 -|(% rowspan="3" %)Style|Pattern|Set alarm range and colors 2443 -|Numerical scale|Check it to display value in object 2444 -|Monitoring name display|Check it to display name in object 2445 -|(% colspan="2" %)Display|Set object position and size 2446 -))) 2447 - 2448 2448 == **6.5 Tool bar** == 2449 2449 2450 2450 The toolbar has the same function as the tool list. (right-click on the canvas to pop up tool list)