Changes for page 05 Cloud SCADA

Last modified by Joe on 2024/08/08 09:29

From version 4.1
edited by Leo
on 2022/06/16 16:25
Change comment: There is no comment for this version
To version 6.1
edited by Leo
on 2022/06/16 17:07
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,11 +1,10 @@
1 1  = 1 Instruction =
2 2  
3 -The default page of the V-BOX WEB SCADA platform after login is shown as Figure 1-1. The main functions of this platform includes the centralized monitoring, template management, project management, and authority management. The user could switch between the function modules through the left navigation bar, and the specific content of each function module will be displayed on the right side.
3 +The default page of the V-BOX WEB SCADA platform after login is shown as below. The main functions of this platform includes the centralized monitoring, template management, project management, and authority management. The user could switch between the function modules through the left navigation bar, and the specific content of each function module will be displayed on the right side.
4 4  
5 5  (% style="text-align:center" %)
6 6  [[image:1617874482390-379.png||height="421" width="800" class="img-thumbnail"]]
7 7  
8 -Figure 1 ‑1
9 9  
10 10  **Introduction**
11 11  
... ... @@ -29,8 +29,6 @@
29 29  (% style="text-align:center" %)
30 30  [[image:1617874518342-186.png||height="357" width="200" class="img-thumbnail"]]
31 31  
32 -Figure 2 ‑1
33 -
34 34  2)The account of the V-box WEB SCADA platform is the same as the V-BOX account.
35 35  
36 36  **✎Note:**
... ... @@ -46,8 +46,6 @@
46 46  (% style="text-align:center" %)
47 47  [[image:1617874482390-379.png||height="421" width="800" class="img-thumbnail"]]
48 48  
49 -Figure 3 ‑1
50 -
51 51  This page shows projects under each group by switching groups. User could add, delete and modify the group.
52 52  
53 53  == 3.1 Group management ==
... ... @@ -67,13 +67,11 @@
67 67  
68 68  == 3.2 Assign project ==
69 69  
70 -The centralized monitoring module includes following functions:add new projects, delete projects and preview projects for each group. Click on the corresponding group to display the list of projects in the group, as shown in Figure 3-3.
65 +The centralized monitoring module includes following functions:add new projects, delete projects and preview projects for each group. Click on the corresponding group to display the list of projects in the group, as shown below.
71 71  
72 72  (% style="text-align:center" %)
73 73  [[image:1617948660671-429.png||height="270" width="800" class="img-thumbnail"]]
74 74  
75 -Figure 3 ‑3
76 -
77 77  1. **Add project:** Click [[image:1617948869319-850.png||class="img-thumbnail"]] in the project list area to assign a project in the group.
78 78  1. **Delete project: **Click [[image:1617948891768-154.png||class="img-thumbnail"]] in the upper right corner of a project thumbnail in the project list to move the project out of the group.
79 79  1. **Preview project:** Click on [[image:1617948906340-294.png||class="img-thumbnail"]] to view the configuration screen of the project. For details, please refer to chapter 3.3.
... ... @@ -80,13 +80,11 @@
80 80  
81 81  == 3.3 Browse project ==
82 82  
83 -Click on [[image:1617948906340-294.png||class="img-thumbnail"]] in the project list to view the configuration screen. See Figure 3-4.
76 +Click on [[image:1617948906340-294.png||class="img-thumbnail"]] in the project list to view the configuration screen.
84 84  
85 85  (% style="text-align:center" %)
86 86  [[image:V-BOX cloud configuration user manual_html_72b4c2044c0ab2fe.png||height="365" width="600" class="img-thumbnail"]]
87 87  
88 -Figure 3 ‑4
89 -
90 90  1. **Real-time data: **Click the [Real-time Data] to view the device name and state. Or view the current value, encoding, description, etc. of each data.
91 91  1. **Alarm data: **Click the [alarm data] button to pop up the alarm record page and view the current alarm status and historical alarm information.
92 92  1. **Historical data:** Click the [History Data] button to pop up the history report interface of the data. User could view all the historical data.
... ... @@ -98,13 +98,11 @@
98 98  
99 99  == **4.1 Template management** ==
100 100  
101 -Click the template management module on the left menu to enter the template management module, as Figure 4-1 shows.
92 +Click the template management module on the left menu to enter the template management module.
102 102  
103 103  (% style="text-align:center" %)
104 104  [[image:1617949183137-615.png||height="205" width="800" class="img-thumbnail"]]
105 105  
106 -Figure 4 ‑1
107 -
108 108  The V-box WEB SCADA platform provides a template management module that could save the designed configuration screen as a template and user could import the template .
109 109  
110 110  == **4.2 Add, edit and delete template** ==
... ... @@ -116,8 +116,6 @@
116 116  (% style="text-align:center" %)
117 117  [[image:1617933432286-367.png||height="347" width="600" class="img-thumbnail"]]
118 118  
119 -Figure 4 ‑2
120 -
121 121  == **4.3 Design template** ==
122 122  
123 123  Click the [Template Design] in the template list to access the V-box configuration platform editor page. User could edit the template in this page. More details about how to design the project please refer to Chapter 6.
... ... @@ -128,13 +128,11 @@
128 128  
129 129  == **5.1 Project management** ==
130 130  
131 -Click the [Project management] on the left menu to enter the project list, as Figure 5-1 shows.
118 +Click the [Project management] on the left menu to enter the project list.
132 132  
133 133  (% style="text-align:center" %)
134 134  [[image:1617949499753-859.png||height="401" width="800" class="img-thumbnail"]]
135 135  
136 -Figure 5 ‑1
137 -
138 138  == **5.2 Add, edit, delete and preview project** ==
139 139  
140 140  1. **Add project:** Click the [Add] in the upper right corner of [Project Management] to add a project (Set project name and cross-box options).
... ... @@ -161,21 +161,17 @@
161 161  (% style="text-align:center" %)
162 162  [[image:1617949467765-343.png||height="393" width="800" class="img-thumbnail"]]
163 163  
164 -Figure 6 ‑1
149 +The function partition of WEB SCADA editor.
165 165  
166 -The function partition of WEB SCADA editor is shown in Figure 6-2.
167 -
168 168  (% style="text-align:center" %)
169 169  [[image:V-box 1.png||alt="V-BOX cloud configuration user manual_html_cb0c19aefec34494.png" height="315" width="600" class="img-thumbnail"]]
170 170  
171 -Figure 6 ‑2
172 -
173 173  1. **Toolbar:** A function bar that provides pages operations and objects operations;
174 174  1. **Project Manager:** It shows all pages for project;
175 175  1. **Objects Library: **It provides 7 basic shapes objects and 13 common objects for creating SCADA page;
176 176  1. **Design Area: **Design area for SCADA page and template;
177 177  
178 -== **6.2 Operating procedures of design** ==
159 +== **6.2 Design** ==
179 179  
180 180  1. Create new page and set the property;
181 181  1. Select the object and drag the mouse in design area;
... ... @@ -184,15 +184,13 @@
184 184  
185 185  == **6.3 Project Screen** ==
186 186  
187 -A project or template is composed of one or several screens. And all screens are listed on [Project Manager] as Figure 6-3 shows. Select screen name, its page would be displayed on [Design Area].
168 +A project or template is composed of one or several screens. And all screens are listed on [Project Manager]. Select screen name, its page would be displayed on [Design Area].
188 188  
189 189  (% style="text-align:center" %)
190 190  [[image:1617949566099-340.png||height="705" width="250" class="img-thumbnail"]]
191 191  
192 -Figure 6 ‑3
173 +Project Manager would display two kinds of screen. One is page screen, and the other is Thumbnail. A project or template could contain several screens, but only one thumbnail. Thumbnail is used for displayed project on [Centralized Monitoring].
193 193  
194 -Project Manager would display two kinds of screen. One is page screen, and the other is Thumbnail. A project or template could contain several screens, but only one thumbnail. Thumbnail is used for displayed project on [Centralized Monitoring] as Figure 6-4 shows.
195 -
196 196  (% style="text-align:center" %)
197 197  [[image:1617949620811-522.png||height="469" width="800" class="img-thumbnail"]]
198 198  
... ... @@ -199,16 +199,13 @@
199 199  (% style="text-align:center" %)
200 200  [[image:1617949663298-790.png||height="413" width="800" class="img-thumbnail"]]
201 201  
202 -Figure 6 ‑4
181 +**Creating thumbnail**
203 203  
204 -**Operating procedures of creating thumbnail**
205 -
206 206  1)Click [[image:V-BOX cloud configuration user manual_html_287ead7d4c995a28.png||height="30" width="30" class="img-thumbnail"]] on [Project Manager];
207 207  
208 208  (% style="text-align:center" %)
209 209  [[image:1617949820581-164.png||height="386" width="500" class="img-thumbnail"]]
210 210  
211 -Figure 6 ‑14
212 212  
213 213  2)Select [Page Type] as [Thumbnail] on screen attribute window;
214 214  
... ... @@ -216,7 +216,7 @@
216 216  
217 217  4)Click [Save] to complete operation;
218 218  
219 -**Operating procedures of creating page screen**
195 +**Creating page screen**
220 220  
221 221  1)Click [[image:V-BOX cloud configuration user manual_html_287ead7d4c995a28.png||height="30" width="30" class="img-thumbnail"]] on [Project Manager];
222 222  
... ... @@ -233,7 +233,7 @@
233 233  
234 234  When a thumbnail page is not created, the default picture would be displayed on [Centralized Monitoring].
235 235  
236 -**Operating procedures of modifying screen**
212 +**Modifying screen**
237 237  
238 238  1. Select the page to be modified;
239 239  1. Click [[image:V-BOX cloud configuration user manual_html_a5f920d2d144472c.png||height="30" width="30" class="img-thumbnail"]] on [Project Manager] or [[image:V-BOX cloud configuration user manual_html_56ae321f2d4418ac.png||height="24" width="147" class="img-thumbnail"]] on [Toolbar];
... ... @@ -241,7 +241,7 @@
241 241  1. Click [[image:V-BOX cloud configuration user manual_html_5970eb09902bd1a3.png||height="30" width="30" class="img-thumbnail"]] on [Toolbar] to complete modification;
242 242  1.
243 243  
244 -**Operating procedures of deleting screen**
220 +**Deleting screen**
245 245  
246 246  1)Select screen on [Project Manager];
247 247  
... ... @@ -250,11 +250,9 @@
250 250  (% style="text-align:center" %)
251 251  [[image:V-BOX cloud configuration user manual_html_1e7f9096426ebeca.png||height="161" width="300" class="img-thumbnail"]]
252 252  
253 -Figure 6 ‑16
254 -
255 255  3)Click [OK] to delete page;
256 256  
257 -**Operating procedures of sort screen**
231 +**Sort screen**
258 258  
259 259  1. Select page screen on [Project Manager];
260 260  1. Click [[image:V-BOX cloud configuration user manual_html_1ab5c888bfd536c.png||height="19" width="40"]] to sort screen upwards or downwards;
... ... @@ -269,24 +269,22 @@
269 269  
270 270  === **6.4.1 Basic Operations** ===
271 271  
272 -**Operating procedures of adding objects on screen**
246 +**Adding objects on screen**
273 273  
274 274  1. Select and click the desired object on [Objects Library];
275 275  1. Move the cursor to the [Design Area];
276 276  1. When cursor changes as + symbol, hold down left click draw the desired size;
277 277  
278 -**Operating procedures of moving object**
252 +**Moving object**
279 279  
280 280  1. Select object on [Design Area];
281 -1. Hold down the left click and move object to desired position, as shown in Figure 6-8.
255 +1. Hold down the left click and move object to desired position.
282 282  
283 283  (% style="text-align:center" %)
284 284  [[image:V-BOX cloud configuration user manual_html_4a7ca599f8cf89c5.png||height="141" width="200" class="img-thumbnail"]]
285 285  
286 -Figure 6 ‑8
260 +**Scaling object**
287 287  
288 -**Operating procedures of scaling object**
289 -
290 290  1)Select object, the positioning control point would appear around object;
291 291  
292 292  2)Click any control point;
... ... @@ -293,17 +293,15 @@
293 293  
294 294  3)Move point to scale object;
295 295  
296 -**Operating procedure of editing object**
268 +**Editing object**
297 297  
298 298  1)Select object;
299 299  
300 -2)Double-click it to open property window as Figure 6-9 shows;
272 +2)Double-click it to open property window;
301 301  
302 302  (% style="text-align:center" %)
303 303  [[image:V-BOX cloud configuration user manual_html_45a8e3cf3e1113fe.png||height="352" width="600" class="img-thumbnail"]]
304 304  
305 -Figure 6 ‑18
306 -
307 307  3)Edit object settings;
308 308  
309 309  4)Click [Save] to complete operation;
... ... @@ -332,10 +332,10 @@
332 332  * **Picture: **It is used for displaying the picture, support the user defined picture.
333 333  
334 334  (% class="table-bordered" %)
335 -|**Property**|**Description**
336 -|Gallery|Choose the picture from the gallery
337 -|Angle|Rotation angle (0~~360)
338 -|Scale|(((
305 +|=(% scope="row" %)**Property**|=**Description**
306 +|=Gallery|Choose the picture from the gallery
307 +|=Angle|Rotation angle (0~~360)
308 +|=Scale|(((
339 339  Yes: the aspect ratio is fixed
340 340  
341 341  No: the aspect ratio is not fixed
... ... @@ -346,11 +346,8 @@
346 346  (% style="text-align:center" %)
347 347  [[image:V-BOX cloud configuration user manual_html_c84a5d0032df07e2.png||height="420" width="250" class="img-thumbnail"]]
348 348  
349 -Figure 6 ‑11
350 -
351 351  * **Display Frame**
352 352  
353 -(% border="2" %)
354 354  |**Item**|**Description**
355 355  |Monitoring Point|Set operating address for this object (Read and write can be different);
356 356  |Read-write permission|There are three modes for it, users could select according to requirements;
... ... @@ -364,7 +364,6 @@
364 364  Indicator could monitor and display the specified PLC or HMI bit address, and its state changes according to the specified address value.
365 365  
366 366  (((
367 -(% border="2" %)
368 368  |**Items**|**Description**
369 369  |Monitor Point|Set reading address for this object;
370 370  |Status|Set text for every status;
... ... @@ -378,7 +378,6 @@
378 378  Switch could operate the specified PLC or HMI bit address, and its state changes according to the specified address value.
379 379  
380 380  (((
381 -(% border="2" %)
382 382  |**Items**|**Description**
383 383  |Monitor Point|Set operating address for this object (Read and write can be different);
384 384  |Read-write permission|There are three modes for it, users could select according to requirements;
... ... @@ -394,7 +394,6 @@
394 394  Display the value of address in real time using the dashboard.
395 395  
396 396  (((
397 -(% border="2" %)
398 398  |**Items**|**Description**
399 399  |Monitor Point|Set operating address for this object (Read and write can be different);
400 400  |Select|Set dashboard display range, there are two modes, Constant and Variable
... ... @@ -410,7 +410,6 @@
410 410  Use the length or height of the rectangle to reflect the value of reading address so that the value could be visualized.
411 411  
412 412  (((
413 -(% border="2" %)
414 414  |**Items**|**Description**
415 415  |Monitor Point|Set operating address for this object (Read and write can be different);
416 416  |Digit Display|Check it to display digit value on bar;
... ... @@ -427,7 +427,6 @@
427 427  Use the curve to show the trend of the data over time. X-axis is time, Y-axis is variable.
428 428  
429 429  (((
430 -(% border="2" %)
431 431  |**Items**|**Description**
432 432  |Monitor Point|Set operating address for this object (Read and write can be different);
433 433  |Digit Display|Check it to display digit value on bar;
... ... @@ -445,7 +445,6 @@
445 445  This is a flowing animation object, users could set animation trigger condition for it, the monitor point could be both bit address and word address;
446 446  
447 447  (((
448 -(% border="2" %)
449 449  |**Items**|**Description**
450 450  |Border color|Set object background color;
451 451  |Color|Set flowing block color;
... ... @@ -457,8 +457,6 @@
457 457  
458 458  Word address: Set value range;
459 459  )))
460 -
461 -(% border="2" %)
462 462  |Color Block Width|Set flowing block size;
463 463  |Color Block Length|Set flowing block size;
464 464  |Color Block Spacing|Set the spacing between flow blocks;
... ... @@ -476,7 +476,6 @@
476 476  Video object is used for playing the video file provided in the video source.
477 477  
478 478  (((
479 -(% border="2" %)
480 480  |**Items**|**Description**
481 481  |Border color|Set object background color;
482 482  |Color|Set flowing block color;
... ... @@ -488,8 +488,6 @@
488 488  
489 489  Word address: Set value range;
490 490  )))
491 -
492 -(% border="2" %)
493 493  |Color Block Width|Set flowing block size;
494 494  |Color Block Length|Set flowing block size;
495 495  |Color Block Spacing|Set the spacing between flow blocks;
... ... @@ -503,8 +503,7 @@
503 503  The object for link website;
504 504  
505 505  (((
506 -(% border="2" %)
507 -|**Items**|**Description**
462 +|=**Items**|=**Description**
508 508  |Link address|Enter website;
509 509  |Open with|There are two options, user could select open with new window or current window;
510 510  |Select Language|One object could support three language, user could enter text for note object;
... ... @@ -517,8 +517,7 @@
517 517  Function switch is designed to switch screens, and call and close sub screen.
518 518  
519 519  (((
520 -(% border="2" %)
521 -|**Items**|**Description**
475 +|=**Items**|=**Description**
522 522  |Screen|Select the target screen for switch;
523 523  |Sub-screen|There are two options, user could select open with new window or current window;
524 524  |Previous|Switch to the previous screen
... ... @@ -534,8 +534,7 @@
534 534  The combination switch supports the collection of multiple functions onto one object. When the object is pressed, multiple functions are arranged in sequence to meet the special requirements of user.
535 535  
536 536  (((
537 -(% border="2" %)
538 -|**Items**|**Description**
491 +|=**Items**|=**Description**
539 539  |Bit operation|It provides [Bit copy], [Set ON], [Set OFF], [Switch] and [Bit Copy] functions.
540 540  |Word operation|It provides [Word copy], [Word set], [Increase] and [Decrease] functions,
541 541  |Arithmetic|[Add], [Subtract], [Multiply] and [Divide] functions
... ... @@ -551,8 +551,7 @@
551 551  It is used for displaying the time of the V-BOX, when the V-BOX is offline, the time will stay at the time when it is offline.
552 552  
553 553  (((
554 -(% border="2" %)
555 -|**Items**|**Description**
507 +|=**Items**|=**Description**
556 556  |Monitoring box|Link a box for the time part
557 557  |Pattern|Two types, one is digit and the other is clock
558 558  |Format settings|Set format for time and date in digit pattern
... ... @@ -566,8 +566,7 @@
566 566  It is used for display more than one tag value in Bar graph format.
567 567  
568 568  (((
569 -(% border="2" %)
570 -|**Items**|**Description**
521 +|=**Items**|=**Description**
571 571  |Add new group|Maximum is 8, add items for this object, also set colors
572 572  |Add monitoring point|Set read tag for every item,
573 573  |Style|Set object display style such as color, use picture as background or not
... ... @@ -579,8 +579,7 @@
579 579  It is used for display alarm information of V-BOX. It can support current and history alarm.
580 580  
581 581  (((
582 -(% border="2" %)
583 -|**Items**|**Description**
533 +|=**Items**|=**Description**
584 584  |Select box|Link to V-BOX
585 585  |Alarm type|Select current alarm or history alarm or all
586 586  |Start date|Alarm display start date
... ... @@ -597,8 +597,7 @@
597 597  The history trend will display data record with graph. X axis represents as time, and Y axis represents as data.
598 598  
599 599  (((
600 -(% border="2" %)
601 -|(% colspan="2" %)**Items**|**Description**
550 +|=(% colspan="2" %)**Items**|=**Description**
602 602  |(% colspan="2" %)Basic|Set numbers of curve in object and select style for every curves including color, link tag
603 603  |(% rowspan="11" %)Style|Display form|Two type, one is curve, and the other is table
604 604  |Start date|Start date of history data
... ... @@ -619,8 +619,7 @@
619 619  This object is used for calling screens when condition is met.
620 620  
621 621  (((
622 -(% border="2" %)
623 -|(% colspan="2" %)**Items**|**Description**
571 +|=(% colspan="2" %)**Items**|=**Description**
624 624  |(% rowspan="4" %)Basic|Conditional trigger|It provides bit, word condition and unconditional
625 625  |Bind monitoring point|Link to tag for triggering
626 626  |Trigger condition|for bit address, it requires ON or OFF, for word address, different value corresponds to different screens.
... ... @@ -634,8 +634,7 @@
634 634  Display value as ring chart
635 635  
636 636  (((
637 -(% border="2" %)
638 -|(% colspan="2" %)**Items**|**Description**
585 +|=(% colspan="2" %)**Items**|=**Description**
639 639  |(% rowspan="7" %)Basic|Monitor point|Link to tag for data reading
640 640  |Range|Set fixed range or variable range
641 641  |Scales|Set scales such as major and minor numbers, colors and so on
... ... @@ -652,8 +652,7 @@
652 652  Display more than one value in one pie chart
653 653  
654 654  (((
655 -(% border="2" %)
656 -|(% colspan="2" %)**Items**|**Description**
602 +|=(% colspan="2" %)**Items**|=**Description**
657 657  |(% colspan="2" %)Monitor point|Add read addresses, the maximum is 8
658 658  |(% rowspan="3" %)Style|Pattern|Set alarm range and colors
659 659  |Numerical scale|Check it to display value in object
... ... @@ -666,8 +666,7 @@
666 666  The toolbar has the same function as the tool list. (right-click on the canvas to pop up tool list)
667 667  
668 668  (((
669 -(% border="2" %)
670 -|**Tool**|**Description**
615 +|=**Tool**|=**Description**
671 671  |[[image:V-BOX cloud configuration user manual_html_668218d361cc54ba.png||height="21" width="76" class="img-thumbnail"]]|Mouse tool for selecting parts. Hold Ctrl key and click on the part to select multiple parts at the same time.
672 672  |[[image:V-BOX cloud configuration user manual_html_867a000ba1161424.png||height="21" width="69" class="img-thumbnail"]]|Save current canvas
673 673  |[[image:V-BOX cloud configuration user manual_html_f5dbf6b889320d6c.png||height="21" width="81" class="img-thumbnail"]]|Delete the selected parts. Multiple selected parts can be deleted at the same time.