Changes for page 05 Cloud SCADA
Last modified by Joe on 2024/08/08 09:29
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -47,13 +47,11 @@ 47 47 48 48 == 3.1 Group management == 49 49 50 -The centralized monitoring module classifies the project by group. As shown in Figure 3-2.50 +The centralized monitoring module classifies the project by group. 51 51 52 52 (% style="text-align:center" %) 53 53 [[image:1617933161760-158.png||height="35" width="900" class="img-thumbnail"]] 54 54 55 -Figure 3 ‑2 56 - 57 57 1. **Switch group:** Click group name to switch group. 58 58 1. **Add a group:** Click [[image:V-BOX cloud configuration user manual_html_b2953a9d44427091.png||height="29" width="30" class="img-thumbnail"]] to add a new group. 59 59 1. **Edit group:** Click [[image:V-BOX cloud configuration user manual_html_516339bb09efc553.png||height="28" width="30" class="img-thumbnail"]] to edit the group name. ... ... @@ -85,9 +85,9 @@ 85 85 1. [[image:V-BOX cloud configuration user manual_html_f89481c3d93517fb.png||height="26" width="28" class="img-thumbnail"]] : Zoom in screen 86 86 1. [[image:V-BOX cloud configuration user manual_html_4836056a73da4491.png||height="27" width="28" class="img-thumbnail"]] : Zoom out screen 87 87 88 -= **4 Templatemanagement**=86 += 4 Template = 89 89 90 -== **4.1 Template management**==88 +== 4.1 Template management == 91 91 92 92 Click the template management module on the left menu to enter the template management module. 93 93 ... ... @@ -96,7 +96,7 @@ 96 96 97 97 The V-box WEB SCADA platform provides a template management module that could save the designed configuration screen as a template and user could import the template . 98 98 99 -== **4.2 Add, edit and delete template**==97 +== 4.2 Add, edit and delete template == 100 100 101 101 1. **Add template: **Click the [Add] to add a template, as Figure 4-2 shows. 102 102 1. **Edit template: **Click the [Edit] to edit the name and resolution of the template. ... ... @@ -105,15 +105,15 @@ 105 105 (% style="text-align:center" %) 106 106 [[image:1617933432286-367.png||height="347" width="600" class="img-thumbnail"]] 107 107 108 -== **4.3 Design template**==106 +== 4.3 Design template == 109 109 110 110 Click the [Template Design] in the template list to access the V-box configuration platform editor page. User could edit the template in this page. More details about how to design the project please refer to Chapter 6. 111 111 112 112 ((( 113 -= **5 Project management**=111 += 5 Project management = 114 114 ))) 115 115 116 -== **5.1 Project management**==114 +== 5.1 Project management == 117 117 118 118 Click the [Project management] on the left menu to enter the project list. 119 119 ... ... @@ -120,7 +120,7 @@ 120 120 (% style="text-align:center" %) 121 121 [[image:1617949499753-859.png||height="401" width="800" class="img-thumbnail"]] 122 122 123 -== **5.2 Add, edit, delete and preview project**==121 +== 5.2 Add, edit, delete and preview project == 124 124 125 125 1. **Add project:** Click the [Add] in the upper right corner of [Project Management] to add a project (Set project name and cross-box options). 126 126 1. **Edit project:** Click the [Edit] in a specific project line of the project list to modify the project (Set project name and cross-box options). ... ... @@ -127,19 +127,19 @@ 127 127 1. **Delete project:** Click the [Delete] to delete the corresponding project. 128 128 1. **Preview project: **Click the [Browse] to browse the project. 129 129 130 -== **5.3 Login-free browse**==128 +== 5.3 Login-free browse == 131 131 132 132 Click the [Login-free browse] in a specific project line of the project list to pop up window, set the expiration time, then user could get the browsing address and QR code (just need a scan to browse). 133 133 134 -== **5.4 Project design**==132 +== 5.4 Project design == 135 135 136 136 Click the [Design] button in a specific project line of the project list to access the WEB SCADA editor. For more details please check Chapter 6. 137 137 138 138 ((( 139 -= **6 V-box WEB SCADA design**=137 += 6 V-box WEB SCADA design = 140 140 ))) 141 141 142 -== **6.1 Main screen and Menu**==140 +== 6.1 Main screen and Menu == 143 143 144 144 Click [Design] (or Template design) in [Project Management] (or Template Management) screen to access WEB SCADA editor. 145 145 ... ... @@ -156,7 +156,7 @@ 156 156 1. **Objects Library: **It provides 7 basic shapes objects and 13 common objects for creating SCADA page; 157 157 1. **Design Area: **Design area for SCADA page and template; 158 158 159 -== **6.2 Design**==157 +== 6.2 Design == 160 160 161 161 1. Create new page and set the property; 162 162 1. Select the object and drag the mouse in design area; ... ... @@ -163,7 +163,7 @@ 163 163 1. Edit object property and set the variable etc; 164 164 1. Save the screen; 165 165 166 -== **6.3 Project Screen**==164 +== 6.3 Project Screen == 167 167 168 168 A project or template is composed of one or several screens. And all screens are listed on [Project Manager]. Select screen name, its page would be displayed on [Design Area]. 169 169 ... ... @@ -237,11 +237,11 @@ 237 237 238 238 Thumbnail does not support sorting. 239 239 240 -== **6.4 Object**==238 +== 6.4 Object == 241 241 242 242 The WEB SCADA platform provides a variety of visualizations for users to design screen. All objects listed on [Object Library]. 243 243 244 -=== **6.4.1 Basic Operations**===242 +=== 6.4.1 Basic Operations === 245 245 246 246 **Adding objects on screen** 247 247 ... ... @@ -278,7 +278,7 @@ 278 278 279 279 4)Click [Save] to complete operation; 280 280 281 -=== **6.4.2 Introduction**===279 +=== 6.4.2 Introduction === 282 282 283 283 **1)Basic** 284 284 ... ... @@ -318,7 +318,6 @@ 318 318 319 319 * **Display Frame** 320 320 321 -(% border="2" %) 322 322 |**Item**|**Description** 323 323 |Monitoring Point|Set operating address for this object (Read and write can be different); 324 324 |Read-write permission|There are three modes for it, users could select according to requirements; ... ... @@ -332,7 +332,6 @@ 332 332 Indicator could monitor and display the specified PLC or HMI bit address, and its state changes according to the specified address value. 333 333 334 334 ((( 335 -(% border="2" %) 336 336 |**Items**|**Description** 337 337 |Monitor Point|Set reading address for this object; 338 338 |Status|Set text for every status; ... ... @@ -346,7 +346,6 @@ 346 346 Switch could operate the specified PLC or HMI bit address, and its state changes according to the specified address value. 347 347 348 348 ((( 349 -(% border="2" %) 350 350 |**Items**|**Description** 351 351 |Monitor Point|Set operating address for this object (Read and write can be different); 352 352 |Read-write permission|There are three modes for it, users could select according to requirements; ... ... @@ -362,7 +362,6 @@ 362 362 Display the value of address in real time using the dashboard. 363 363 364 364 ((( 365 -(% border="2" %) 366 366 |**Items**|**Description** 367 367 |Monitor Point|Set operating address for this object (Read and write can be different); 368 368 |Select|Set dashboard display range, there are two modes, Constant and Variable ... ... @@ -378,7 +378,6 @@ 378 378 Use the length or height of the rectangle to reflect the value of reading address so that the value could be visualized. 379 379 380 380 ((( 381 -(% border="2" %) 382 382 |**Items**|**Description** 383 383 |Monitor Point|Set operating address for this object (Read and write can be different); 384 384 |Digit Display|Check it to display digit value on bar; ... ... @@ -395,7 +395,6 @@ 395 395 Use the curve to show the trend of the data over time. X-axis is time, Y-axis is variable. 396 396 397 397 ((( 398 -(% border="2" %) 399 399 |**Items**|**Description** 400 400 |Monitor Point|Set operating address for this object (Read and write can be different); 401 401 |Digit Display|Check it to display digit value on bar; ... ... @@ -413,7 +413,6 @@ 413 413 This is a flowing animation object, users could set animation trigger condition for it, the monitor point could be both bit address and word address; 414 414 415 415 ((( 416 -(% border="2" %) 417 417 |**Items**|**Description** 418 418 |Border color|Set object background color; 419 419 |Color|Set flowing block color; ... ... @@ -425,8 +425,6 @@ 425 425 426 426 Word address: Set value range; 427 427 ))) 428 - 429 -(% border="2" %) 430 430 |Color Block Width|Set flowing block size; 431 431 |Color Block Length|Set flowing block size; 432 432 |Color Block Spacing|Set the spacing between flow blocks; ... ... @@ -444,7 +444,6 @@ 444 444 Video object is used for playing the video file provided in the video source. 445 445 446 446 ((( 447 -(% border="2" %) 448 448 |**Items**|**Description** 449 449 |Border color|Set object background color; 450 450 |Color|Set flowing block color; ... ... @@ -456,8 +456,6 @@ 456 456 457 457 Word address: Set value range; 458 458 ))) 459 - 460 -(% border="2" %) 461 461 |Color Block Width|Set flowing block size; 462 462 |Color Block Length|Set flowing block size; 463 463 |Color Block Spacing|Set the spacing between flow blocks; ... ... @@ -471,8 +471,7 @@ 471 471 The object for link website; 472 472 473 473 ((( 474 -(% border="2" %) 475 -|**Items**|**Description** 460 +|=**Items**|=**Description** 476 476 |Link address|Enter website; 477 477 |Open with|There are two options, user could select open with new window or current window; 478 478 |Select Language|One object could support three language, user could enter text for note object; ... ... @@ -485,8 +485,7 @@ 485 485 Function switch is designed to switch screens, and call and close sub screen. 486 486 487 487 ((( 488 -(% border="2" %) 489 -|**Items**|**Description** 473 +|=**Items**|=**Description** 490 490 |Screen|Select the target screen for switch; 491 491 |Sub-screen|There are two options, user could select open with new window or current window; 492 492 |Previous|Switch to the previous screen ... ... @@ -502,8 +502,7 @@ 502 502 The combination switch supports the collection of multiple functions onto one object. When the object is pressed, multiple functions are arranged in sequence to meet the special requirements of user. 503 503 504 504 ((( 505 -(% border="2" %) 506 -|**Items**|**Description** 489 +|=**Items**|=**Description** 507 507 |Bit operation|It provides [Bit copy], [Set ON], [Set OFF], [Switch] and [Bit Copy] functions. 508 508 |Word operation|It provides [Word copy], [Word set], [Increase] and [Decrease] functions, 509 509 |Arithmetic|[Add], [Subtract], [Multiply] and [Divide] functions ... ... @@ -519,8 +519,7 @@ 519 519 It is used for displaying the time of the V-BOX, when the V-BOX is offline, the time will stay at the time when it is offline. 520 520 521 521 ((( 522 -(% border="2" %) 523 -|**Items**|**Description** 505 +|=**Items**|=**Description** 524 524 |Monitoring box|Link a box for the time part 525 525 |Pattern|Two types, one is digit and the other is clock 526 526 |Format settings|Set format for time and date in digit pattern ... ... @@ -534,8 +534,7 @@ 534 534 It is used for display more than one tag value in Bar graph format. 535 535 536 536 ((( 537 -(% border="2" %) 538 -|**Items**|**Description** 519 +|=**Items**|=**Description** 539 539 |Add new group|Maximum is 8, add items for this object, also set colors 540 540 |Add monitoring point|Set read tag for every item, 541 541 |Style|Set object display style such as color, use picture as background or not ... ... @@ -547,8 +547,7 @@ 547 547 It is used for display alarm information of V-BOX. It can support current and history alarm. 548 548 549 549 ((( 550 -(% border="2" %) 551 -|**Items**|**Description** 531 +|=**Items**|=**Description** 552 552 |Select box|Link to V-BOX 553 553 |Alarm type|Select current alarm or history alarm or all 554 554 |Start date|Alarm display start date ... ... @@ -565,8 +565,7 @@ 565 565 The history trend will display data record with graph. X axis represents as time, and Y axis represents as data. 566 566 567 567 ((( 568 -(% border="2" %) 569 -|(% colspan="2" %)**Items**|**Description** 548 +|=(% colspan="2" %)**Items**|=**Description** 570 570 |(% colspan="2" %)Basic|Set numbers of curve in object and select style for every curves including color, link tag 571 571 |(% rowspan="11" %)Style|Display form|Two type, one is curve, and the other is table 572 572 |Start date|Start date of history data ... ... @@ -587,8 +587,7 @@ 587 587 This object is used for calling screens when condition is met. 588 588 589 589 ((( 590 -(% border="2" %) 591 -|(% colspan="2" %)**Items**|**Description** 569 +|=(% colspan="2" %)**Items**|=**Description** 592 592 |(% rowspan="4" %)Basic|Conditional trigger|It provides bit, word condition and unconditional 593 593 |Bind monitoring point|Link to tag for triggering 594 594 |Trigger condition|for bit address, it requires ON or OFF, for word address, different value corresponds to different screens. ... ... @@ -602,8 +602,7 @@ 602 602 Display value as ring chart 603 603 604 604 ((( 605 -(% border="2" %) 606 -|(% colspan="2" %)**Items**|**Description** 583 +|=(% colspan="2" %)**Items**|=**Description** 607 607 |(% rowspan="7" %)Basic|Monitor point|Link to tag for data reading 608 608 |Range|Set fixed range or variable range 609 609 |Scales|Set scales such as major and minor numbers, colors and so on ... ... @@ -620,8 +620,7 @@ 620 620 Display more than one value in one pie chart 621 621 622 622 ((( 623 -(% border="2" %) 624 -|(% colspan="2" %)**Items**|**Description** 600 +|=(% colspan="2" %)**Items**|=**Description** 625 625 |(% colspan="2" %)Monitor point|Add read addresses, the maximum is 8 626 626 |(% rowspan="3" %)Style|Pattern|Set alarm range and colors 627 627 |Numerical scale|Check it to display value in object ... ... @@ -634,8 +634,7 @@ 634 634 The toolbar has the same function as the tool list. (right-click on the canvas to pop up tool list) 635 635 636 636 ((( 637 -(% border="2" %) 638 -|**Tool**|**Description** 613 +|=**Tool**|=**Description** 639 639 |[[image:V-BOX cloud configuration user manual_html_668218d361cc54ba.png||height="21" width="76" class="img-thumbnail"]]|Mouse tool for selecting parts. Hold Ctrl key and click on the part to select multiple parts at the same time. 640 640 |[[image:V-BOX cloud configuration user manual_html_867a000ba1161424.png||height="21" width="69" class="img-thumbnail"]]|Save current canvas 641 641 |[[image:V-BOX cloud configuration user manual_html_f5dbf6b889320d6c.png||height="21" width="81" class="img-thumbnail"]]|Delete the selected parts. Multiple selected parts can be deleted at the same time.