Changes for page 05 Cloud SCADA
Last modified by Joe on 2024/08/08 09:29
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -47,11 +47,13 @@ 47 47 48 48 == 3.1 Group management == 49 49 50 -The centralized monitoring module classifies the project by group. 50 +The centralized monitoring module classifies the project by group. As shown in Figure 3-2. 51 51 52 52 (% style="text-align:center" %) 53 53 [[image:1617933161760-158.png||height="35" width="900" class="img-thumbnail"]] 54 54 55 +Figure 3 ‑2 56 + 55 55 1. **Switch group:** Click group name to switch group. 56 56 1. **Add a group:** Click [[image:V-BOX cloud configuration user manual_html_b2953a9d44427091.png||height="29" width="30" class="img-thumbnail"]] to add a new group. 57 57 1. **Edit group:** Click [[image:V-BOX cloud configuration user manual_html_516339bb09efc553.png||height="28" width="30" class="img-thumbnail"]] to edit the group name. ... ... @@ -83,9 +83,9 @@ 83 83 1. [[image:V-BOX cloud configuration user manual_html_f89481c3d93517fb.png||height="26" width="28" class="img-thumbnail"]] : Zoom in screen 84 84 1. [[image:V-BOX cloud configuration user manual_html_4836056a73da4491.png||height="27" width="28" class="img-thumbnail"]] : Zoom out screen 85 85 86 -= 4 Template management = 88 += **4 Template management** = 87 87 88 -== 4.1 Template management == 90 +== **4.1 Template management** == 89 89 90 90 Click the template management module on the left menu to enter the template management module. 91 91 ... ... @@ -94,7 +94,7 @@ 94 94 95 95 The V-box WEB SCADA platform provides a template management module that could save the designed configuration screen as a template and user could import the template . 96 96 97 -== 4.2 Add, edit and delete template == 99 +== **4.2 Add, edit and delete template** == 98 98 99 99 1. **Add template: **Click the [Add] to add a template, as Figure 4-2 shows. 100 100 1. **Edit template: **Click the [Edit] to edit the name and resolution of the template. ... ... @@ -103,15 +103,15 @@ 103 103 (% style="text-align:center" %) 104 104 [[image:1617933432286-367.png||height="347" width="600" class="img-thumbnail"]] 105 105 106 -== 4.3 Design template == 108 +== **4.3 Design template** == 107 107 108 108 Click the [Template Design] in the template list to access the V-box configuration platform editor page. User could edit the template in this page. More details about how to design the project please refer to Chapter 6. 109 109 110 110 ((( 111 -= 5 Project management = 113 += **5 Project management** = 112 112 ))) 113 113 114 -== 5.1 Project management == 116 +== **5.1 Project management** == 115 115 116 116 Click the [Project management] on the left menu to enter the project list. 117 117 ... ... @@ -118,7 +118,7 @@ 118 118 (% style="text-align:center" %) 119 119 [[image:1617949499753-859.png||height="401" width="800" class="img-thumbnail"]] 120 120 121 -== 5.2 Add, edit, delete and preview project == 123 +== **5.2 Add, edit, delete and preview project** == 122 122 123 123 1. **Add project:** Click the [Add] in the upper right corner of [Project Management] to add a project (Set project name and cross-box options). 124 124 1. **Edit project:** Click the [Edit] in a specific project line of the project list to modify the project (Set project name and cross-box options). ... ... @@ -125,19 +125,19 @@ 125 125 1. **Delete project:** Click the [Delete] to delete the corresponding project. 126 126 1. **Preview project: **Click the [Browse] to browse the project. 127 127 128 -== 5.3 Login-free browse == 130 +== **5.3 Login-free browse** == 129 129 130 130 Click the [Login-free browse] in a specific project line of the project list to pop up window, set the expiration time, then user could get the browsing address and QR code (just need a scan to browse). 131 131 132 -== 5.4 Project design == 134 +== **5.4 Project design** == 133 133 134 134 Click the [Design] button in a specific project line of the project list to access the WEB SCADA editor. For more details please check Chapter 6. 135 135 136 136 ((( 137 -= 6 V-box WEB SCADA design = 139 += **6 V-box WEB SCADA design** = 138 138 ))) 139 139 140 -== 6.1 Main screen and Menu == 142 +== **6.1 Main screen and Menu** == 141 141 142 142 Click [Design] (or Template design) in [Project Management] (or Template Management) screen to access WEB SCADA editor. 143 143 ... ... @@ -154,7 +154,7 @@ 154 154 1. **Objects Library: **It provides 7 basic shapes objects and 13 common objects for creating SCADA page; 155 155 1. **Design Area: **Design area for SCADA page and template; 156 156 157 -== 6.2 Design == 159 +== **6.2 Design** == 158 158 159 159 1. Create new page and set the property; 160 160 1. Select the object and drag the mouse in design area; ... ... @@ -161,7 +161,7 @@ 161 161 1. Edit object property and set the variable etc; 162 162 1. Save the screen; 163 163 164 -== 6.3 Project Screen == 166 +== **6.3 Project Screen** == 165 165 166 166 A project or template is composed of one or several screens. And all screens are listed on [Project Manager]. Select screen name, its page would be displayed on [Design Area]. 167 167 ... ... @@ -235,11 +235,11 @@ 235 235 236 236 Thumbnail does not support sorting. 237 237 238 -== 6.4 Object == 240 +== **6.4 Object** == 239 239 240 240 The WEB SCADA platform provides a variety of visualizations for users to design screen. All objects listed on [Object Library]. 241 241 242 -=== 6.4.1 Basic Operations === 244 +=== **6.4.1 Basic Operations** === 243 243 244 244 **Adding objects on screen** 245 245 ... ... @@ -276,7 +276,7 @@ 276 276 277 277 4)Click [Save] to complete operation; 278 278 279 -=== 6.4.2 Introduction === 281 +=== **6.4.2 Introduction** === 280 280 281 281 **1)Basic** 282 282 ... ... @@ -316,6 +316,7 @@ 316 316 317 317 * **Display Frame** 318 318 321 +(% border="2" %) 319 319 |**Item**|**Description** 320 320 |Monitoring Point|Set operating address for this object (Read and write can be different); 321 321 |Read-write permission|There are three modes for it, users could select according to requirements; ... ... @@ -329,6 +329,7 @@ 329 329 Indicator could monitor and display the specified PLC or HMI bit address, and its state changes according to the specified address value. 330 330 331 331 ((( 335 +(% border="2" %) 332 332 |**Items**|**Description** 333 333 |Monitor Point|Set reading address for this object; 334 334 |Status|Set text for every status; ... ... @@ -342,6 +342,7 @@ 342 342 Switch could operate the specified PLC or HMI bit address, and its state changes according to the specified address value. 343 343 344 344 ((( 349 +(% border="2" %) 345 345 |**Items**|**Description** 346 346 |Monitor Point|Set operating address for this object (Read and write can be different); 347 347 |Read-write permission|There are three modes for it, users could select according to requirements; ... ... @@ -357,6 +357,7 @@ 357 357 Display the value of address in real time using the dashboard. 358 358 359 359 ((( 365 +(% border="2" %) 360 360 |**Items**|**Description** 361 361 |Monitor Point|Set operating address for this object (Read and write can be different); 362 362 |Select|Set dashboard display range, there are two modes, Constant and Variable ... ... @@ -372,6 +372,7 @@ 372 372 Use the length or height of the rectangle to reflect the value of reading address so that the value could be visualized. 373 373 374 374 ((( 381 +(% border="2" %) 375 375 |**Items**|**Description** 376 376 |Monitor Point|Set operating address for this object (Read and write can be different); 377 377 |Digit Display|Check it to display digit value on bar; ... ... @@ -388,6 +388,7 @@ 388 388 Use the curve to show the trend of the data over time. X-axis is time, Y-axis is variable. 389 389 390 390 ((( 398 +(% border="2" %) 391 391 |**Items**|**Description** 392 392 |Monitor Point|Set operating address for this object (Read and write can be different); 393 393 |Digit Display|Check it to display digit value on bar; ... ... @@ -405,6 +405,7 @@ 405 405 This is a flowing animation object, users could set animation trigger condition for it, the monitor point could be both bit address and word address; 406 406 407 407 ((( 416 +(% border="2" %) 408 408 |**Items**|**Description** 409 409 |Border color|Set object background color; 410 410 |Color|Set flowing block color; ... ... @@ -416,6 +416,8 @@ 416 416 417 417 Word address: Set value range; 418 418 ))) 428 + 429 +(% border="2" %) 419 419 |Color Block Width|Set flowing block size; 420 420 |Color Block Length|Set flowing block size; 421 421 |Color Block Spacing|Set the spacing between flow blocks; ... ... @@ -433,6 +433,7 @@ 433 433 Video object is used for playing the video file provided in the video source. 434 434 435 435 ((( 447 +(% border="2" %) 436 436 |**Items**|**Description** 437 437 |Border color|Set object background color; 438 438 |Color|Set flowing block color; ... ... @@ -444,6 +444,8 @@ 444 444 445 445 Word address: Set value range; 446 446 ))) 459 + 460 +(% border="2" %) 447 447 |Color Block Width|Set flowing block size; 448 448 |Color Block Length|Set flowing block size; 449 449 |Color Block Spacing|Set the spacing between flow blocks; ... ... @@ -457,7 +457,8 @@ 457 457 The object for link website; 458 458 459 459 ((( 460 -|=**Items**|=**Description** 474 +(% border="2" %) 475 +|**Items**|**Description** 461 461 |Link address|Enter website; 462 462 |Open with|There are two options, user could select open with new window or current window; 463 463 |Select Language|One object could support three language, user could enter text for note object; ... ... @@ -470,7 +470,8 @@ 470 470 Function switch is designed to switch screens, and call and close sub screen. 471 471 472 472 ((( 473 -|=**Items**|=**Description** 488 +(% border="2" %) 489 +|**Items**|**Description** 474 474 |Screen|Select the target screen for switch; 475 475 |Sub-screen|There are two options, user could select open with new window or current window; 476 476 |Previous|Switch to the previous screen ... ... @@ -486,7 +486,8 @@ 486 486 The combination switch supports the collection of multiple functions onto one object. When the object is pressed, multiple functions are arranged in sequence to meet the special requirements of user. 487 487 488 488 ((( 489 -|=**Items**|=**Description** 505 +(% border="2" %) 506 +|**Items**|**Description** 490 490 |Bit operation|It provides [Bit copy], [Set ON], [Set OFF], [Switch] and [Bit Copy] functions. 491 491 |Word operation|It provides [Word copy], [Word set], [Increase] and [Decrease] functions, 492 492 |Arithmetic|[Add], [Subtract], [Multiply] and [Divide] functions ... ... @@ -502,7 +502,8 @@ 502 502 It is used for displaying the time of the V-BOX, when the V-BOX is offline, the time will stay at the time when it is offline. 503 503 504 504 ((( 505 -|=**Items**|=**Description** 522 +(% border="2" %) 523 +|**Items**|**Description** 506 506 |Monitoring box|Link a box for the time part 507 507 |Pattern|Two types, one is digit and the other is clock 508 508 |Format settings|Set format for time and date in digit pattern ... ... @@ -516,7 +516,8 @@ 516 516 It is used for display more than one tag value in Bar graph format. 517 517 518 518 ((( 519 -|=**Items**|=**Description** 537 +(% border="2" %) 538 +|**Items**|**Description** 520 520 |Add new group|Maximum is 8, add items for this object, also set colors 521 521 |Add monitoring point|Set read tag for every item, 522 522 |Style|Set object display style such as color, use picture as background or not ... ... @@ -528,7 +528,8 @@ 528 528 It is used for display alarm information of V-BOX. It can support current and history alarm. 529 529 530 530 ((( 531 -|=**Items**|=**Description** 550 +(% border="2" %) 551 +|**Items**|**Description** 532 532 |Select box|Link to V-BOX 533 533 |Alarm type|Select current alarm or history alarm or all 534 534 |Start date|Alarm display start date ... ... @@ -545,7 +545,8 @@ 545 545 The history trend will display data record with graph. X axis represents as time, and Y axis represents as data. 546 546 547 547 ((( 548 -|=(% colspan="2" %)**Items**|=**Description** 568 +(% border="2" %) 569 +|(% colspan="2" %)**Items**|**Description** 549 549 |(% colspan="2" %)Basic|Set numbers of curve in object and select style for every curves including color, link tag 550 550 |(% rowspan="11" %)Style|Display form|Two type, one is curve, and the other is table 551 551 |Start date|Start date of history data ... ... @@ -566,7 +566,8 @@ 566 566 This object is used for calling screens when condition is met. 567 567 568 568 ((( 569 -|=(% colspan="2" %)**Items**|=**Description** 590 +(% border="2" %) 591 +|(% colspan="2" %)**Items**|**Description** 570 570 |(% rowspan="4" %)Basic|Conditional trigger|It provides bit, word condition and unconditional 571 571 |Bind monitoring point|Link to tag for triggering 572 572 |Trigger condition|for bit address, it requires ON or OFF, for word address, different value corresponds to different screens. ... ... @@ -580,7 +580,8 @@ 580 580 Display value as ring chart 581 581 582 582 ((( 583 -|=(% colspan="2" %)**Items**|=**Description** 605 +(% border="2" %) 606 +|(% colspan="2" %)**Items**|**Description** 584 584 |(% rowspan="7" %)Basic|Monitor point|Link to tag for data reading 585 585 |Range|Set fixed range or variable range 586 586 |Scales|Set scales such as major and minor numbers, colors and so on ... ... @@ -597,7 +597,8 @@ 597 597 Display more than one value in one pie chart 598 598 599 599 ((( 600 -|=(% colspan="2" %)**Items**|=**Description** 623 +(% border="2" %) 624 +|(% colspan="2" %)**Items**|**Description** 601 601 |(% colspan="2" %)Monitor point|Add read addresses, the maximum is 8 602 602 |(% rowspan="3" %)Style|Pattern|Set alarm range and colors 603 603 |Numerical scale|Check it to display value in object ... ... @@ -610,7 +610,8 @@ 610 610 The toolbar has the same function as the tool list. (right-click on the canvas to pop up tool list) 611 611 612 612 ((( 613 -|=**Tool**|=**Description** 637 +(% border="2" %) 638 +|**Tool**|**Description** 614 614 |[[image:V-BOX cloud configuration user manual_html_668218d361cc54ba.png||height="21" width="76" class="img-thumbnail"]]|Mouse tool for selecting parts. Hold Ctrl key and click on the part to select multiple parts at the same time. 615 615 |[[image:V-BOX cloud configuration user manual_html_867a000ba1161424.png||height="21" width="69" class="img-thumbnail"]]|Save current canvas 616 616 |[[image:V-BOX cloud configuration user manual_html_f5dbf6b889320d6c.png||height="21" width="81" class="img-thumbnail"]]|Delete the selected parts. Multiple selected parts can be deleted at the same time.