Wiki source code of 02 Cloud SCADA

Version 21.1 by Stone Wu on 2022/07/15 12:01

Show last authors
1 = **1 Introduction** =
2
3 The default page of the V-BOX web SCADA platform after login is shown as below. The main functions of this platform include the centralized monitoring, template management, project management, and authority management. The user could switch between the function modules through the left navigation bar, and the specific content of each function module will be displayed on the right side.
4
5 (% style="text-align:center" %)
6 [[image:1617874482390-379.png||height="421" width="800" class="img-thumbnail"]]
7
8 **Introduction**
9
10 1. **Centralized monitoring:** project list, that is displayed in groups;
11 1. **Template management**: add and edit templates;
12 1. **Authority management:** assign a project with configuration authority for view-account
13
14 = 2 Log in =
15
16 Click Cloud SCADA under service in the upper right corner, or enter [[http:~~/~~/web.v-box.net/>>http://web.v-box.net/]] on browser.
17
18 [[image:image-20220714150826-1.jpeg]]
19
20 The account of the V-box web SCADA platform is the same as the V-BOX account.
21
22 (% style="text-align:center" %)
23 [[image:1617874518342-186.png||height="357" width="200" class="img-thumbnail"]]
24
25 (((
26 = 3 Centralized monitoring =
27 )))
28
29 Centralized monitoring is the default home page of the platform. As shown as the figure below.
30
31 (% style="text-align:center" %)
32 [[image:1617874482390-379.png||height="421" width="800" class="img-thumbnail"]]
33
34 This page displays projects under each group by switching groups. You could add, delete and modify the group. In addition, you ccoul add or remove projects from groups, browse projects, and configure project parameters.
35
36 == Group management ==
37
38 The centralized monitoring module classifies the project by group.
39
40 [[image:image-20220714151453-2.jpeg||height="394" width="795"]]
41
42
43 1. **Switch group:** Click group name to switch group.
44 1. **Add a group:** Click [[image:V-BOX cloud configuration user manual_html_b2953a9d44427091.png||height="33" width="35" class="img-thumbnail"]] to add a new group.
45 1. **Edit group:** Click [[image:V-BOX cloud configuration user manual_html_516339bb09efc553.png||height="32" width="35" class="img-thumbnail"]] to edit the group name.
46 1. **Delete group:** Click [[image:V-BOX cloud configuration user manual_html_c92089cb54d385cd.png||height="33" width="35" class="img-thumbnail"]] to delete the current group.
47 1. **More group:** Click [[image:V-BOX cloud configuration user manual_html_df266f0fa8d8536e.png||height="33" width="35" class="img-thumbnail"]] to display the previous or next group.
48
49 == New project ==
50
51 Click "New project" on the upper right corner to create a new project. You could input the project name, select a group and whether it is cross-box.
52
53 [[image:image-20220715094953-3.jpeg]]
54
55 Click "Thumbnail" to upload a thumbnai. It will be displayed as the preview image of the project.
56
57 [[image:image-20220715094733-2.jpeg]]
58
59 (% class="box infomessage" %)
60 (((
61 **✎Note: ** A project can upload no thumbnails or up to one thumbnail. When no thumbnail is uploaded, the project list will be displayed with the system default image
62 )))
63
64 == Manage project ==
65
66 The centralized monitoring module includes the following functions: add new projects, delete projects and preview projects for each group. Click on the corresponding group to display the list of projects in the group, as shown below.[[image:image-20220715100603-4.jpeg]]
67
68 1. **manage project:** Click "manage project" to assign a project in the group.
69 1. **Delete project: **Click [[image:1617948891768-154.png||class="img-thumbnail"]] on the upper right corner of a project thumbnail in the project list to move the project out of the group.
70 1. **Preview project:** Click on [[image:1617948906340-294.png||class="img-thumbnail"]] to view the configuration screen of the project.
71 1. **Display mode: ** You could switch the display mode by clicking the icons on the upper right corner of page, shown as below.
72
73 (% style="text-align:center" %)
74 [[image:image-20220715101053-5.jpeg]]
75
76 == Browse project ==
77
78 Click on [[image:1617948906340-294.png||class="img-thumbnail"]] in the project list to view the configuration screen.
79
80 (% style="text-align:center" %)
81 [[image:V-BOX cloud configuration user manual_html_72b4c2044c0ab2fe.png||height="365" width="600" class="img-thumbnail"]]
82
83 1. **Real-time data: **Click the "Real-time Data" to view the device name and state, current value, encoding, description, etc.
84 1. **Alarm data: **Click the "Alarm data" button to pop up the alarm record page and view the current alarm status and historical alarm information.
85 1. **Historical data:** Click the "History Data" button to pop up the history report interface of the data. You could view all the historical data.
86 1. **Multi-language:** multi-language drop-down menu, one object could support three language at the same time, you could switch language by this menu.
87 1. [[image:image-20220715101731-6.jpeg||height="50" width="50" class="img-thumbnail"]] Open or close the alarm sound of the alarm record object.
88 1. [[image:image-20220715101736-7.jpeg||height="52" width="51" class="img-thumbnail"]] Full screen display or restore configuration screen.
89 1. [[image:image-20220715101741-8.jpeg||height="51" width="50" class="img-thumbnail"]] Hide or show the top blue menu bar.
90 1. [[image:image-20220715101747-9.jpeg||height="50" width="50" class="img-thumbnail"]] Zoom in the screen.
91 1. [[image:image-20220715101753-10.jpeg||height="51" width="50" class="img-thumbnail"]] Zoom out the screen.
92
93 == Project setting ==
94
95 [[image:image-20220715103031-11.jpeg]]
96
97 * [[image:image-20220715104640-1.jpeg||height="34" width="41"]]**Configuration design:** Click  the button  to enter the configuration programmer to design the configuration screen for that project. Please refer to [[5 V-box WEB SCADA design>>||anchor="H6V-boxWEBSCADAdesign"]] for details.
98 * [[image:image-20220715104711-2.jpeg||height="32" width="40"]]**Preview project:** Click the project preview image or click the button to browse the configuration screen of the project.
99 * [[image:image-20220715104745-3.jpeg]]**Login-free browse: **Click the button and set the expiration time in the pop-up box to generate the browsing address and QR code (scan to browse, but not to operate).
100 * [[image:image-20220715104944-7.jpeg]]**Copy project:** Click the button to set the name and group of the new project to add a new project.
101 * [[image:image-20220715105016-8.jpeg]]**Export project:** Click the button to export the project.
102 * [[image:image-20220715105102-9.jpeg]]**Edit project:** Click the button to modify the project (project name and whether or not to cross V-BOX option), upload and delete thumbnails.
103 * [[image:image-20220715105139-10.jpeg]]**Delete project:** Click the button to delete the project.
104 * [[image:image-20220715105152-11.jpeg||height="36" width="43"]]**Assigned to a group: **Click the button to assign the project to a group.
105
106 = 4 Template =
107
108 == Template management ==
109
110 Click the template management module on the left menu to enter the template management module.
111
112 (% style="text-align:center" %)
113 [[image:1617949183137-615.png||height="205" width="800" class="img-thumbnail"]]
114
115 The V-box Web SCADA platform provides a template management module that could save the designed configuration screen as a template and user could import the template to design the project more efficiently.
116
117 == Add, edit and delete template ==
118
119 [[image:image-20220715105925-1.jpeg||height="46" width="45"]]**Add template: **Click the button to add a template as below.
120
121 [[image:image-20220715110054-4.jpeg]]
122
123 [[image:image-20220715105933-2.jpeg||height="37" width="45"]]**Edit template: **Click the button to edit the name and resolution of the template.
124
125 [[image:image-20220715105937-3.jpeg||height="42" width="42"]]**Delete template: **Click the button to delete the template.
126
127 == Template design ==
128
129 Click the "Template Design" in the template list to access the V-box configuration platform editor page. You could edit the template in this page. More details about how to design the project please refer to [[5 V-box WEB SCADA design>>||anchor="H6V-boxWEBSCADAdesign"]].
130
131 (% class="box infomessage" %)
132 (((
133 **✎Note: **
134
135 * Only templates of the same resolution can be imported into the configuration screen of the project;
136 * Template design only supports single screen design;
137 * Template screen does not support import and export, preview, compile, import other templates, and bind monitoring point functions.
138 )))
139
140 (((
141 = 5 V-BOX WEB SCADA design =
142 )))
143
144 == Main screen ==
145
146 Click "Design" (or Template design) in "Project Management" (or Template Management) screen to access WEB SCADA editor.
147
148 (% style="text-align:center" %)
149 [[image:1617949467765-343.png||height="393" width="800" class="img-thumbnail"]]
150
151 The function partition of WEB SCADA editor.
152
153 (% style="text-align:center" %)
154 [[image:V-box 1.png||alt="V-BOX cloud configuration user manual_html_cb0c19aefec34494.png" height="315" width="600" class="img-thumbnail"]]
155
156 1. **Toolbar:** A function bar that provides pages operations and objects operations;
157 1. **Project Manager:** It shows all screens for project and operations.
158 1. **Objects Library: **It provides 8 basic shapes objects and 20 common objects for creating SCADA page;
159 1. **Design Area: **Design area for SCADA page and template;
160
161 == Design process ==
162
163 1. Create new screen and set the property;
164 1. Select the object and drag the mouse in design area;
165 1. Edit object property and set the variable etc;
166 1. Save the screen;
167
168 == Screen management ==
169
170 A project or template is composed of one or several screens. A template contains only one screen, whereas a project can be composed of one or more screens (only take project as an example.). All screens are listed on "Project Manager". Select screen name, its page would be displayed on "Design Area".
171
172 [[image:image-20220715113713-9.jpeg]]
173
174 The screens are divided into normal screens and sub-screens, as shown above.
175
176 * The normal screen will be displayed when viewing a project or template.
177 * Sub-screen is embedded in the pop-up box of the normal screen, and the function switch and other objects are used to click the popup display.
178
179 In the project browsing page, the default display is the top common screen in the screen list, i.e., the main screen in the figure above, and the other screens will be switched through screen jumping or linking, etc.
180
181 **Create screens**
182
183 Click [[image:image-20220715114850-12.jpeg||height="30" width="48"]] to create a new screen. Set the porperties in the pop-up box, select the screen type (normal screen and sub-screen) and save.
184
185 [[image:image-20220715114601-11.jpeg]]
186
187 (% class="box infomessage" %)
188 (((
189 **✎Note:** When a thumbnail page is not created, the default picture would be displayed on "Centralized Monitoring".
190 )))
191
192 **Modifying screen**
193
194 1. Select the page to be modified;
195 1. Click [[image:V-BOX cloud configuration user manual_html_a5f920d2d144472c.png||height="30" width="30" class="img-thumbnail"]] on "Project Manager" or [[image:V-BOX cloud configuration user manual_html_56ae321f2d4418ac.png||height="24" width="147" class="img-thumbnail"]] on "Toolbar";
196 1. Modify screen on [Design Area];
197 1. Click [[image:V-BOX cloud configuration user manual_html_5970eb09902bd1a3.png||height="30" width="30" class="img-thumbnail"]] on "Toolbar" to complete modification;
198
199 **Deleting screen**
200
201 1. Select screen on "Project Manager";
202 1. Click[[image:V-BOX cloud configuration user manual_html_dca942a0244f9912.png||height="29" width="30"]] , and following message would pop up to prevent accidental deletion;
203
204 (% style="text-align:center" %)
205 [[image:V-BOX cloud configuration user manual_html_1e7f9096426ebeca.png||height="161" width="300" class="img-thumbnail"]]
206
207 (% start="3" %)
208 1. Click "OK" to delete page.
209
210 **Sort screen**
211
212 1. Select page screen on "Project Manager";
213 1. Click [[image:V-BOX cloud configuration user manual_html_1ab5c888bfd536c.png||height="25" width="53"]] to sort screen upwards or downwards.
214
215 (% class="box infomessage" %)
216 (((
217 **✎Note:** Thumbnail does not support sorting.
218 )))
219
220 == Object ==
221
222 The WEB SCADA platform provides a variety of visualizations for users to design screen. All objects listed on [Object Library].
223
224 === 6.4.1 Basic ===
225
226 **Adding objects on screen**
227
228 1. Select and click the desired object on [Objects Library];
229 1. Move the cursor to the [Design Area];
230 1. When cursor changes as + symbol, hold down left click draw the desired size;
231
232 **Moving object**
233
234 1. Select object on [Design Area];
235 1. Hold down the left click and move object to desired position.
236
237 (% style="text-align:center" %)
238 [[image:V-BOX cloud configuration user manual_html_4a7ca599f8cf89c5.png||height="141" width="200" class="img-thumbnail"]]
239
240 **Scaling object**
241
242 1)Select object, the positioning control point would appear around object;
243
244 2)Click any control point;
245
246 3)Move point to scale object;
247
248 **Editing object**
249
250 1)Select object;
251
252 2)Double-click it to open property window;
253
254 (% style="text-align:center" %)
255 [[image:V-BOX cloud configuration user manual_html_45a8e3cf3e1113fe.png||height="352" width="600" class="img-thumbnail"]]
256
257 3)Edit object settings;
258
259 4)Click [Save] to complete operation;
260
261 === 6.4.2 Introduction ===
262
263 **1)Basic**
264
265 (% style="text-align:center" %)
266 [[image:1617949894556-149.png||height="402" width="250" class="img-thumbnail"]]
267
268 Figure 6 ‑10
269
270 * **Line: **a common line, user could set color, line type and thickness for it;
271
272 * **Rectangles: **User could set transparency, Rounded Conner, color of filled and border, line type and thickness for it;
273
274 * **Circle:** User could set transparency, color of filled and border, line type and thickness for it.
275
276 * **Ellipse: **User could set transparency, color of filled and border, line type and thickness for it.
277
278 * **Triangle: **User could set transparency, color of filled and border, line type and thickness for it.
279
280 * **Text: **It is used for displaying text content. User could set text styles, background styles, also it supports three languages at the same time.
281
282 * **Picture: **It is used for displaying the picture, support the user defined picture.
283
284 (% class="table-bordered" %)
285 |=(% scope="row" %)**Property**|=**Description**
286 |=Gallery|Choose the picture from the gallery
287 |=Angle|Rotation angle (0~~360)
288 |=Scale|(((
289 Yes: the aspect ratio is fixed
290
291 No: the aspect ratio is not fixed
292 )))
293
294 **2)Common**
295
296 (% style="text-align:center" %)
297 [[image:V-BOX cloud configuration user manual_html_c84a5d0032df07e2.png||height="420" width="250" class="img-thumbnail"]]
298
299 * **Display Frame**
300
301 |**Item**|**Description**
302 |Monitoring Point|Set operating address for this object (Read and write can be different);
303 |Read-write permission|There are three modes for it, users could select according to requirements;
304 |Set Text|It is used for setting style of text and display direction
305 |Style|It is used for setting object display, like background color;
306 |Expansion|It is used for setting expansion function, like lock position;
307 |Display|It is used for setting object position and size
308
309 * **Bit /Word Indicator**
310
311 Indicator could monitor and display the specified PLC or HMI bit address, and its state changes according to the specified address value.
312
313 (((
314 |**Items**|**Description**
315 |Monitor Point|Set reading address for this object;
316 |Status|Set text for every status;
317 |Picture|Set picture for every status;
318 |Expansion|Set display expansion function, such as blink
319 |Display|Set object position and size
320 )))
321
322 * **Bit/ Word Switch**
323
324 Switch could operate the specified PLC or HMI bit address, and its state changes according to the specified address value.
325
326 (((
327 |**Items**|**Description**
328 |Monitor Point|Set operating address for this object (Read and write can be different);
329 |Read-write permission|There are three modes for it, users could select according to requirements;
330 |Pop up a confirmation box|Check it to enable confirmation box for operating;
331 |Status|Set text for every status;
332 |Picture|Set picture for every status;
333 |Expansion|Set display expansion function, such as blink
334 |Display|Set object position and size
335 )))
336
337 * **Dashboard**
338
339 Display the value of address in real time using the dashboard.
340
341 (((
342 |**Items**|**Description**
343 |Monitor Point|Set operating address for this object (Read and write can be different);
344 |Select|Set dashboard display range, there are two modes, Constant and Variable
345 |Scale value|Check it to display value;
346 |Select Language|Set text for object;
347 |Style|Set object display style such as color, scales number;
348 |Alarm Zone|Set range and color for alarm
349 |Display|Set object position and size
350 )))
351
352 * **Bar graph**
353
354 Use the length or height of the rectangle to reflect the value of reading address so that the value could be visualized.
355
356 (((
357 |**Items**|**Description**
358 |Monitor Point|Set operating address for this object (Read and write can be different);
359 |Digit Display|Check it to display digit value on bar;
360 |Progress bar direction|Select display direction;
361 |Scales|Set object scales display type and color;
362 |Bar color|Set color for bar;
363 |Background Display|Set color of bar background;
364 |Alarm Zone|Set range and color for alarm
365 |Display|Set object position and size
366 )))
367
368 * **Real-Time Trend Chart**
369
370 Use the curve to show the trend of the data over time. X-axis is time, Y-axis is variable.
371
372 (((
373 |**Items**|**Description**
374 |Monitor Point|Set operating address for this object (Read and write can be different);
375 |Digit Display|Check it to display digit value on bar;
376 |Progress bar direction|Select display direction;
377 |Scales|Set object scales display type and color;
378 |Bar color|Set color for bar;
379 |Background Display|Set color of bar background;
380 |Alarm Zone|Set range and color for alarm
381 |Display|Set object position and size
382 | |
383 )))
384
385 * **Flow pipe**
386
387 This is a flowing animation object, users could set animation trigger condition for it, the monitor point could be both bit address and word address;
388
389 (((
390 |**Items**|**Description**
391 |Border color|Set object background color;
392 |Color|Set flowing block color;
393 |Speed|Three modes for flowing block speed;
394 |Flow direction|Two modes for flowing direction;
395 |Monitor Point|Set trigger address;
396 |Trigger Condition|(((
397 Bit address: Select ON or OFF;
398
399 Word address: Set value range;
400 )))
401 |Color Block Width|Set flowing block size;
402 |Color Block Length|Set flowing block size;
403 |Color Block Spacing|Set the spacing between flow blocks;
404 |Display Border|Select display or hide border;
405 |Alarm Zone|Set range and color for alarm
406 |Display|Set object position and size
407 )))
408
409 **Tips for designing flow bar**
410
411 When user need to simulate the flow of water in a pipe, please put the pipe picture at first, then hide the flow border and place it onto the pipe picture.
412
413 * **Video object**
414
415 Video object is used for playing the video file provided in the video source.
416
417 (((
418 |**Items**|**Description**
419 |Border color|Set object background color;
420 |Color|Set flowing block color;
421 |Speed|Three modes for flowing block speed;
422 |Flow direction|Two modes for flowing direction;
423 |Monitor Point|Set trigger address;
424 |Trigger Condition|(((
425 Bit address: Select ON or OFF;
426
427 Word address: Set value range;
428 )))
429 |Color Block Width|Set flowing block size;
430 |Color Block Length|Set flowing block size;
431 |Color Block Spacing|Set the spacing between flow blocks;
432 |Display Border|Select display or hide border;
433 |Alarm Zone|Set range and color for alarm
434 |Display|Set object position and size
435 )))
436
437 * **Hyperlink**
438
439 The object for link website;
440
441 (((
442 |=**Items**|=**Description**
443 |Link address|Enter website;
444 |Open with|There are two options, user could select open with new window or current window;
445 |Select Language|One object could support three language, user could enter text for note object;
446 |Style|Set object display style such as color, use picture as background or not
447 |Display|Set object position and size
448 )))
449
450 * **Function Switch**
451
452 Function switch is designed to switch screens, and call and close sub screen.
453
454 (((
455 |=**Items**|=**Description**
456 |Screen|Select the target screen for switch;
457 |Sub-screen|There are two options, user could select open with new window or current window;
458 |Previous|Switch to the previous screen
459 |Next|Switch to the next screen
460 |Return|Return to the screen before switch
461 |Text|Set text for object, including text font, color direction and so on;
462 |Style|Set object display style such as color, use picture as background or not
463 |Display|Set object position and size
464 )))
465
466 * **Combination Switch**
467
468 The combination switch supports the collection of multiple functions onto one object. When the object is pressed, multiple functions are arranged in sequence to meet the special requirements of user.
469
470 (((
471 |=**Items**|=**Description**
472 |Bit operation|It provides [Bit copy], [Set ON], [Set OFF], [Switch] and [Bit Copy] functions.
473 |Word operation|It provides [Word copy], [Word set], [Increase] and [Decrease] functions,
474 |Arithmetic|[Add], [Subtract], [Multiply] and [Divide] functions
475 |Screen change|It provides screen switch function as [Function Switch], it supports [Previous], [Next], [Return], [Change to], and open, close sub-screen operations
476 |Delete|Delete selected item function;
477 |Empty|Delete all items in operation list;
478 |Up|Move the selected item up one row in operation list;
479 |Down|Move the selected item down one row in operation list;
480 )))
481
482 **Time**
483
484 It is used for displaying the time of the V-BOX, when the V-BOX is offline, the time will stay at the time when it is offline.
485
486 (((
487 |=**Items**|=**Description**
488 |Monitoring box|Link a box for the time part
489 |Pattern|Two types, one is digit and the other is clock
490 |Format settings|Set format for time and date in digit pattern
491 |Background|Set display or hide background of object
492 |Set text|Set text display style;
493 |Display|Set object position and size
494 )))
495
496 **Histogram**
497
498 It is used for display more than one tag value in Bar graph format.
499
500 (((
501 |=**Items**|=**Description**
502 |Add new group|Maximum is 8, add items for this object, also set colors
503 |Add monitoring point|Set read tag for every item,
504 |Style|Set object display style such as color, use picture as background or not
505 |Display|Set object position and size
506 )))
507
508 **Alarm record display**
509
510 It is used for display alarm information of V-BOX. It can support current and history alarm.
511
512 (((
513 |=**Items**|=**Description**
514 |Select box|Link to V-BOX
515 |Alarm type|Select current alarm or history alarm or all
516 |Start date|Alarm display start date
517 |End date|Alarm display end date
518 |Format|Set display format for date and time
519 |Sequence|It provides two type, one is order, and the other is reverse order
520 |Display content|Users could select display contents by check them
521 |Style|Set colors for different parts
522 |Display|Set object position and size
523 )))
524
525 **History trend chart**
526
527 The history trend will display data record with graph. X axis represents as time, and Y axis represents as data.
528
529 (((
530 |=(% colspan="2" %)**Items**|=**Description**
531 |(% colspan="2" %)Basic|Set numbers of curve in object and select style for every curves including color, link tag
532 |(% rowspan="11" %)Style|Display form|Two type, one is curve, and the other is table
533 |Start date|Start date of history data
534 |End date|End date of history data
535 |Format|Time and date format for display
536 |Sequence|Two types, order or reverse order
537 |Y range|Two types, fixed and adaptive
538 |Set text|Set font size, color and other styles.
539 |Transparency|Set transparency of object
540 |Background color|Two types, translucent or transparent
541 |Gradient way|Set display way and color
542 |Display bar|Check it to display screen bar
543 |(% colspan="2" %)Display|Set object position and size
544 )))
545
546 **Indirect screen display**
547
548 This object is used for calling screens when condition is met.
549
550 (((
551 |=(% colspan="2" %)**Items**|=**Description**
552 |(% rowspan="4" %)Basic|Conditional trigger|It provides bit, word condition and unconditional
553 |Bind monitoring point|Link to tag for triggering
554 |Trigger condition|for bit address, it requires ON or OFF, for word address, different value corresponds to different screens.
555 |Designated screen|Only for bit address as trigger. When condition is met, display this screen
556 |(% colspan="2" %)Style|Set object display style such as display title bar or display or hide background
557 |(% colspan="2" %)Display|Set object position and size
558 )))
559
560 **Ring chart**
561
562 Display value as ring chart
563
564 (((
565 |=(% colspan="2" %)**Items**|=**Description**
566 |(% rowspan="7" %)Basic|Monitor point|Link to tag for data reading
567 |Range|Set fixed range or variable range
568 |Scales|Set scales such as major and minor numbers, colors and so on
569 |Designated screen|Only for bit address as trigger. When condition is met, display this screen
570 |Numerical scale display|Check it to display scale
571 |Start angle|Set start angle for scale
572 |Color|Color setting for bar and background
573 |(% colspan="2" %)Alarm Zone|Set alarm range and colors
574 |(% colspan="2" %)Display|Set object position and size
575 )))
576
577 **Pie chart**
578
579 Display more than one value in one pie chart
580
581 (((
582 |=(% colspan="2" %)**Items**|=**Description**
583 |(% colspan="2" %)Monitor point|Add read addresses, the maximum is 8
584 |(% rowspan="3" %)Style|Pattern|Set alarm range and colors
585 |Numerical scale|Check it to display value in object
586 |Monitoring name display|Check it to display name in object
587 |(% colspan="2" %)Display|Set object position and size
588 )))
589
590 == **6.5 Tool bar** ==
591
592 The toolbar has the same function as the tool list. (right-click on the canvas to pop up tool list)
593
594 (((
595 |=**Tool**|=**Description**
596 |[[image:V-BOX cloud configuration user manual_html_668218d361cc54ba.png||height="21" width="76" class="img-thumbnail"]]|Mouse tool for selecting parts. Hold Ctrl key and click on the part to select multiple parts at the same time.
597 |[[image:V-BOX cloud configuration user manual_html_867a000ba1161424.png||height="21" width="69" class="img-thumbnail"]]|Save current canvas
598 |[[image:V-BOX cloud configuration user manual_html_f5dbf6b889320d6c.png||height="21" width="81" class="img-thumbnail"]]|Delete the selected parts. Multiple selected parts can be deleted at the same time.
599 |[[image:V-BOX cloud configuration user manual_html_e5d36271faf64986.png||height="21" width="73" class="img-thumbnail"]]|Copy the selected parts.
600 |[[image:V-BOX cloud configuration user manual_html_97033b77500d6b5e.png||height="21" width="75" class="img-thumbnail"]]|Paste the selected parts
601 |[[image:V-BOX cloud configuration user manual_html_53bc6f617b145720.png||height="22" width="148" class="img-thumbnail"]]|The property of the current screen
602 |[[image:V-BOX cloud configuration user manual_html_44a3e98a692aee6a.png||height="21" width="157" class="img-thumbnail"]]|Import the configured template for the current screen
603 |[[image:V-BOX cloud configuration user manual_html_30f2f1591b0a9e66.png||height="22" width="89" class="img-thumbnail"]]|Browse the current project interface. The default home page is the top screen in the project page list.
604 |[[image:V-BOX cloud configuration user manual_html_6aae3377add443ff.png||height="38" width="150" class="img-thumbnail"]]|Align left edge of multiple parts
605 |[[image:V-BOX cloud configuration user manual_html_dc8fb256a13e2f91.png||height="40" width="150" class="img-thumbnail"]]|Align right edge of multiple parts
606 |[[image:V-BOX cloud configuration user manual_html_bec295f2d25219f9.png||height="39" width="150" class="img-thumbnail"]]|Align top edge of multiple parts
607 |[[image:V-BOX cloud configuration user manual_html_4a0c10157943d534.png||height="39" width="150" class="img-thumbnail"]]|Align bottom edge of multiple parts
608 |[[image:V-BOX cloud configuration user manual_html_378cd8ba635ed3f4.png||height="38" width="150" class="img-thumbnail"]]|Place the selected part on top of the other parts
609 |[[image:V-BOX cloud configuration user manual_html_6a594344368f5276.png||height="38" width="150" class="img-thumbnail"]]|Place the selected part on the bottom of the other parts
610 )))
611
612 (((
613 = **7 Authority** =
614 )))
615
616 Click the Authority management on the left menu to enter the Authority management module, as Figure 7-1 shows.
617
618 [[image:1617949992819-138.png||class="img-thumbnail"]]
619
620 Figure 7 ‑11
621
622 This module is used for assigning project and configuring permissions for sub-accounts.
623
624 **1)How to assign project for sub-account**
625
626 * Click the button [[image:V-BOX cloud configuration user manual_html_d96aea12cdb7cdb1.png||height="26" width="150" class="img-thumbnail"]] at the end of the sub-account line to enter the project list page of the sub-account, as shown in Figure 7-2.
627 * Click the button [[image:V-BOX cloud configuration user manual_html_5fd249946ccb44cc.png||height="34" width="150" class="img-thumbnail"]] on the top right corner of window, select the project of the pop window and then click save to get the permissions of the selected project for the account, as shown in Figure 7-3.
628
629 (% style="text-align:center" %)
630 [[image:1617934946822-979.png||height="421" width="800" class="img-thumbnail"]]
631
632 Figure 7 ‑2
633
634 (% style="text-align:center" %)
635 [[image:1617950026178-538.png||height="375" width="600" class="img-thumbnail"]]
636
637 Figure 7 ‑3
638
639 **2)How to unassigned project for sub-account**
640
641 In the list of assigned projects in the sub-account, click “Unbind Project” to unbind the project for the account.
642
643 = **8 Demo account** =
644
645 **1)What is Cloud SCADA platform?**
646
647 Cloud SCADA is an IoT platform that can realize terminal equipment data collection, real-time control, alarm push, group management, configuration design and other functions. With this platform, users can monitor terminal equipment more conveniently.
648
649 **2)How to access?**
650
651 Asean URL: [[http:~~/~~/asean.v-box.net/web/htmlnew/user/login.html>>url:http://asean.v-box.net/web/htmlnew/user/login.html]]
652
653 Asean account&password: weconuser 123123
654
655 EU URL: [[http:~~/~~/eu.v-box.net/web/htmlnew/user/login.html>>url:http://eu.v-box.net/web/htmlnew/user/login.html]]
656
657 EU account&password: weconuser weconuser123
658 **✎Note1: **users can edit Cloud SCADA project freely, and the modified results will not be saved.
659
660 **✎Note2: **users can enter the Cloud SCADA page by clicking the following positions:
661
662 (% style="text-align:center" %)
663 [[image:1648577581177-590.png||height="408" width="800" class="img-thumbnail"]]
664
665 **3)Industry classification**
666
667 There are 20 Cloud SCADA projects created in demo account, including HVAC system, water treatment system, smart farm, smart factory and smart city.
668
669 (% style="text-align:center" %)
670 [[image:1648577644453-821.png||height="377" width="800" class="img-thumbnail"]]
671
672 **4)Part of the project introduction**
673
674 4.1 Heating Monitoring System
675
676 Collect the analog signals of the temperature, pressure and flow rate of the outlet water of the heat exchanger, and use PID to control the valve diameter of the heat exchanger and the rotation speed of the circulating pump to achieve the purpose of automatic temperature adjustment.
677
678 (% style="text-align:center" %)
679 [[image:1648577724164-599.png||height="393" width="800" class="img-thumbnail"]]
680
681 (% style="text-align:center" %)
682 [[image:1648577744837-247.png||height="450" width="800" class="img-thumbnail"]]
683
684 4.2 Water Treatment System
685
686 Industry introduction: water treatment system.Mainly to improve waterquality, to meet certain water quality standards, such as drinking water, industrial wastewater discharge.In order to ensure the stable operation of the water treatment system, it is necessary to monitor the water pressure and water level, and adjust the   appropriate water pressure and water level by remote control of the pumpspeed.
687
688 (% style="text-align:center" %)
689 [[image:1648577778435-311.png||height="450" width="800" class="img-thumbnail"]]
690
691 4.3 Smart City Monitoring
692
693 The multi-functional city monitoring system can be applied to multiple scenarios such as HVAC, factory, and pump station monitoring. Monitor and control common industrial parameters such as voltage, current, power, frequency, temperature, liquid level, etc.
694
695 (% style="text-align:center" %)
696 [[image:1648577825813-481.png||height="452" width="800" class="img-thumbnail"]]
697
698 (% style="text-align:center" %)
699 [[image:1648577843849-690.png||height="452" width="800" class="img-thumbnail"]]
700
701 4.4 Smart Building Monitoring
702
703 It is used in community management to monitor various facilities in the community such as elevator equipment, lighting system, parking lot, fire fighting equipment, etc. In the event of an abnormality in the equipment, such as elevator damage, insufficient fire water, etc., an alarm prompt is sent to the manager.
704
705 (% style="text-align:center" %)
706 [[image:1648577874801-932.png||height="408" width="800" class="img-thumbnail"]]
707
708 (% style="text-align:center" %)
709 [[image:1648577894932-957.png||height="408" width="800" class="img-thumbnail"]]