Changes for page 07 HTTP API
Last modified by Devin Chen on 2025/04/10 16:16
From version 25.1
edited by Devin Chen
on 2025/04/10 16:16
on 2025/04/10 16:16
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. DevinChen1 +XWiki.Mora - Content
-
... ... @@ -427,12 +427,11 @@ 427 427 (% class="table-bordered" %) 428 428 |**acturl**|(% colspan="3" %)we-data/realcfgs 429 429 |**Functions**|(% colspan="3" %)Get the tags configuration information in the specified group in V-BOX. 430 -|(% colspan="1"rowspan="6" %)**Parameters**|Parameter|(% colspan="2" %)Description430 +|(% rowspan="5" %)**Parameters**|Parameter|(% colspan="2" %)Description 431 431 |boxId|(% colspan="2" %)VBoxID(“None” means custom tags grouping) 432 432 |groupId|(% colspan="2" %)Group ID (Required) 433 433 |pageSize|(% colspan="2" %)Number of each page, 10 by default 434 434 |pageIndex|(% colspan="2" %)Number of current page, start from 1 435 -|devType|(% colspan="2" %)Device type (0:Box, 1:HMI) 436 436 |(% rowspan="15" %)**Return value**|Field name|(% colspan="2" %)Description 437 437 |(% rowspan="11" %)cfgList|monitorId|Tags ID 438 438 |monitorName|Tags name ... ... @@ -583,21 +583,16 @@ 583 583 584 584 == **Tags data list** == 585 585 586 -{{warning}} 587 -This API is not for getting the real-time data all the time.If you need to get the continuously updated real-time monitoring point data values,you need to use **[[Send switch to device>>https://docs.we-con.com.cn/bin/view/V-BOX/V-Net/Manual/6%20HTTP%20API/#HSendswitchtodevice]] **API with this API 588 -{{/warning}} 589 - 590 590 **~ {{id name="_Toc24963744"/}}Parameters** 591 591 592 592 (% class="table-bordered" %) 593 593 |**acturl**|(% colspan="3" %)we-data/realdata 594 594 |**Functions**|(% colspan="3" %)Get the tags data in the specified group in V-BOX. 595 -|(% colspan="1"rowspan="6" %)**Parameters**|Parameter|(% colspan="2" %)Description590 +|(% rowspan="5" %)**Parameters**|Parameter|(% colspan="2" %)Description 596 596 |boxId|(% colspan="2" %)VBoxID(“None” means custom tag grouping) 597 597 |groupId|(% colspan="2" %)Group ID (Required) 598 598 |pageSize|(% colspan="2" %)Number of each page, 10 by default 599 599 |pageIndex|(% colspan="2" %)Number of current page, start from 1 600 -|devType|(% colspan="2" %)Device type (0:Box, 1:HMI) 601 601 |(% rowspan="11" %)**Return value**|Field name|(% colspan="2" %)Description 602 602 |(% rowspan="7" %)List|(% colspan="2" %)Real-time data list 603 603 |com|Communication port ID ... ... @@ -712,11 +712,9 @@ 712 712 (% class="table-bordered" %) 713 713 |**acturl**|(% colspan="2" %)we-data/updrealdata 714 714 |**Functions**|(% colspan="2" %)Modify tag data 715 -|(% rowspan="5" %)**Parameters**|Parameter|Description 716 -|boxId|Box ID 709 +|(% rowspan="3" %)**Parameters**|Parameter|Description 717 717 |monitorId|Tag ID 718 718 |value|value 719 -|devType|Device type (0:Box, 1:HMI) 720 720 |**Return value**|(% colspan="2" %)None 721 721 722 722 **Operating procedures** ... ... @@ -765,7 +765,7 @@ 765 765 (% style="text-align:center" %) 766 766 [[image:V-BOX HTTP manual_html_590c8dab9e80fd0f.png||height="425" width="700" class="img-thumbnail"]] 767 767 768 -== **Historical tags name list** == 760 +== ** {{id name="_Toc24963751"/}}Historical tags name list** == 769 769 770 770 **Parameters** 771 771 ... ... @@ -772,9 +772,8 @@ 772 772 (% class="table-bordered" %) 773 773 |**acturl**|(% colspan="3" %)we-data/monitors 774 774 |**Functions**|(% colspan="3" %)Get a list of historical tags 775 -|(% rowspan="3" %)**Parameters**|Parameter|(% colspan="2" %)Description 776 -|boxId|(% colspan="2" %)Box ID (Not required) 777 -|devType|(% colspan="2" %)Device type (0:Box, 1:HMI) 767 +|(% rowspan="2" %)**Parameters**|Parameter|(% colspan="2" %)Description 768 +|boxId|(% colspan="2" %)VBoxID (Not required) 778 778 |(% rowspan="4" %)**Return value**|Field name|(% colspan="2" %)Description 779 779 |(% rowspan="3" %)list|(% colspan="2" %)Tag list 780 780 |monitorId|tag ID ... ... @@ -850,7 +850,7 @@ 850 850 (% style="text-align:center" %) 851 851 [[image:V-BOX HTTP manual_html_2a739377a9fb10b2.png||height="400" width="700" class="img-thumbnail"]] 852 852 853 -== **Historical tag data list** == 844 +== ** {{id name="_Toc24963755"/}}Historical tag data list** == 854 854 855 855 **~ {{id name="_Toc24963756"/}}Parameters** 856 856 ... ... @@ -977,7 +977,7 @@ 977 977 (% class="table-bordered" %) 978 978 |**acturl**|(% colspan="3" %)we-data/alarmdata 979 979 |**Function**|(% colspan="3" %)Get alarm data 980 -|(% rowspan=" 10" %)**Parameters**|Parameter|(% colspan="2" %)Description971 +|(% rowspan="9" %)**Parameters**|Parameter|(% colspan="2" %)Description 981 981 |boxId|(% colspan="2" %)VBoxID, (Required) 982 982 |monitorBeginTime|(% colspan="2" %)Monitoring start time, (Not required) 983 983 |monitorEndTime|(% colspan="2" %)Monitoring end time, (Not required) ... ... @@ -994,7 +994,6 @@ 994 994 995 995 (Not necessary) 996 996 ))) 997 -|devType|(% colspan="2" %)Device type (0:Box, 1:HMI) 998 998 |(% rowspan="12" %)**Return value**|Field name|(% colspan="2" %)Description 999 999 |(% rowspan="8" %)List|(% colspan="2" %)Alarm data list 1000 1000 |monitorId|tag ID