Changes for page 08 OPC tool
Last modified by Mora Zhou on 2025/01/17 09:56
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,10 +1,10 @@ 1 -= ** 1Introduction** =1 += **Introduction** = 2 2 3 3 **Open Platform Communications (OPC) **is a series of standards and specifications for industrial telecommunication. They are based on **Object Linking and Embedding (OLE) for process control**. 4 4 5 5 WECON provides **OPC Data Access(OPC DA)** for communicating real-time data from data acquisition devices, which is V-Box. 6 6 7 -= ** 2Premise** =7 += **Premise** = 8 8 9 9 Due to OPC is based on Microsoft's COM (COmponent Model), and OPC's remote communication relies on Microsoft's DCOM (Distribute COM), and security is based on Microsoft's Windows security settings. About how to setup the DCOM on Windows PC, please refer to the following two links: 10 10 ... ... @@ -12,11 +12,11 @@ 12 12 13 13 2) [[INSTALLING OPC CORE COMPONENTS ON WINDOWS 8>>https://www.aggsoft.com/opc-data-logger/tutorials/dcom-opc-config-windows-8-2012-1.htm]] 14 14 15 -= ** 3Basic configuration** =15 += **Basic configuration** = 16 16 17 17 V-Box pushes the data source to other OPC Clients through OPC tool, such as SCADA software, CFM software, ERP/MES systems, etc. 18 18 19 -== ** 3.1Login interface** ==19 +== **Login interface** == 20 20 21 21 {{info}} 22 22 **✎Note:** Because now all the tools are integrated into the V-NET Client, please login into the V-NET Client software to find OPC tool. ... ... @@ -34,7 +34,7 @@ 34 34 1. Remember password: use DES secondary encryption, the secret key is CPUID and network card MAC address respectively. 35 35 1. Configure the server address, and the software restart is required for the configuration to take effect. 36 36 37 -== ** 3.2Server setting** ==37 +== **Server setting** == 38 38 39 39 The default server address is the V-NET monitoring address. When deploying a private cloud, connect to the corresponding network address. After configuring the server address, the OPC Tool restart is required to take effect. 40 40 ... ... @@ -57,7 +57,7 @@ 57 57 1. **Asean:http:~/~/api.asean.v-box.net** 58 58 1. **Europe:http:~/~/api.eu.v-box.net** 59 59 60 -== ** 3.3Configured successfully** ==60 +== **Configured successfully** == 61 61 62 62 After the user logs in successfully, the OPC SERVER is started. As shown below. 63 63 ... ... @@ -67,20 +67,27 @@ 67 67 (% class="wikigeneratedid" %) 68 68 **✎Note:** When using the OPC function, run the OPC Tool software. 69 69 70 -= ** 4Example** =70 += **Example** = 71 71 72 72 (% class="lead" %) 73 -**The precondition is to use the OPC Server and OPC Client on the same PC.** 73 +**The precondition is to use the OPC Server and OPC Client on the same PC.** 74 74 75 -== ** 4.1Run the OPC tool** ==75 +== **Run the OPC tool** == 76 76 77 77 (% style="text-align:center" %) 78 78 [[image:12-3 2.png||class="img-thumbnail"]] 79 79 80 -== ** 4.2Create OPC device** ==80 +== **Create OPC device** == 81 81 82 -Ta ke the**OPC Quick Client.exe** tool for example. [[**Download** here>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Software/Kepware-OPCClient.zip]].82 +The following example is taking **OPC Quick Client.exe** tool for demonstration. [[**Download** here>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Software/Kepware-OPCClient.zip]]. 83 83 84 +{{info}} 85 +✎Note: If having trouble of "Failed to connect server" or not able to find V-BOX.OPCSERVER.DLL in Server Properties, please go to the V-NET Client installation path to install the necessary OPC runtime environment. 86 +{{/info}} 87 + 88 +(% style="text-align:center" %) 89 +[[image:OPCruntimelocation.png]] 90 + 84 84 **(1)** Run** "OPC Quick Client.exe"** 85 85 86 86 (% style="text-align:center" %) ... ... @@ -105,8 +105,6 @@ 105 105 (% style="text-align:center" %) 106 106 [[image:12-8.png||class="img-thumbnail"]] 107 107 108 -✎Note: If meet with the question of "Failed to connect server" or not able to find V-BOX.OPCSERVER.DLL in Server Properties, please go to the V-NET Client installation path to install the 109 - 110 110 **(4) **Add a new group, set the group name according to your needs. 111 111 112 112 (% style="text-align:center" %)
- OPCruntimelocation.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +62.9 KB - Content