Changes for page 08 OPC tool

Last modified by Mora Zhou on 2025/01/17 09:56

From version 9.4
edited by Hunter
on 2023/05/13 11:53
Change comment: There is no comment for this version
To version 30.1
edited by Mora Zhou
on 2025/01/17 09:56
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -8 OPC tool
1 +08 OPC tool
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Hunter
1 +XWiki.Mora
Content
... ... @@ -1,11 +1,15 @@
1 -= **1 Introduction** =
1 += **Introduction** =
2 2  
3 3  **Open Platform Communications (OPC) **is a series of standards and specifications for industrial telecommunication. They are based on **Object Linking and Embedding (OLE) for process control**.
4 4  
5 5  WECON provides **OPC Data Access(OPC DA)** for communicating real-time data from data acquisition devices, which is V-Box.
6 6  
7 -= **2 Premise** =
7 +{{info}}
8 +**✎Note: **ig series HMI doesn't support OPC DA. This OPC tool only works with V-BOX.
9 +{{/info}}
8 8  
11 += **Premise** =
12 +
9 9  Due to OPC is based on Microsoft's COM (COmponent Model), and OPC's remote communication relies on Microsoft's DCOM (Distribute COM), and security is based on Microsoft's Windows security settings. About how to setup the DCOM on Windows PC, please refer to the following two links:
10 10  
11 11  1)[[ DCOM for Windows 7,10, & Server 2008R2 and Newer>>https://www.softwaretoolbox.com/dcom/html/dcom_for_windows_7-_10-_-_server_2008r2.html]]
... ... @@ -12,14 +12,14 @@
12 12  
13 13  2) [[INSTALLING OPC CORE COMPONENTS ON WINDOWS 8>>https://www.aggsoft.com/opc-data-logger/tutorials/dcom-opc-config-windows-8-2012-1.htm]]
14 14  
15 -= **3 Basic configuration** =
19 += **Basic configuration** =
16 16  
17 17  V-Box pushes the data source to other OPC Clients through OPC tool, such as SCADA software, CFM software, ERP/MES systems, etc.
18 18  
19 -== **3.1 Login interface** ==
23 +== **Login interface** ==
20 20  
21 21  {{info}}
22 -**✎Note:** Because now all the tools are integrated into the V-NET Client, please login into the V-NET Client software to find OPC tool.
26 +**✎Note:** Now, all the tools are integrated into** V-NET Client**, please login into **V-NET Client** to find OPC tool.
23 23  {{/info}}
24 24  
25 25  (% style="text-align:center" %)
... ... @@ -34,7 +34,7 @@
34 34  1. Remember password: use DES secondary encryption, the secret key is CPUID and network card MAC address respectively.
35 35  1. Configure the server address, and the software restart is required for the configuration to take effect.
36 36  
37 -== **2.2 Server setting** ==
41 +== **Server setting** ==
38 38  
39 39  The default server address is the V-NET monitoring address. When deploying a private cloud, connect to the corresponding network address. After configuring the server address, the OPC Tool restart is required to take effect.
40 40  
... ... @@ -57,7 +57,7 @@
57 57  1. **Asean:http:~/~/api.asean.v-box.net**
58 58  1. **Europe:http:~/~/api.eu.v-box.net**
59 59  
60 -== **2.3 configuration successfully** ==
64 +== **Configured successfully** ==
61 61  
62 62  After the user logs in successfully, the OPC SERVER is started. As shown below.
63 63  
... ... @@ -67,20 +67,31 @@
67 67  (% class="wikigeneratedid" %)
68 68  **✎Note:** When using the OPC function, run the OPC Tool software.
69 69  
70 -= **3 Example** =
74 += **Example** =
71 71  
72 72  (% class="lead" %)
73 -**The precondition is to use the OPC Server and OPC Client on the same PC.**
77 +**The precondition is to use the OPC Server and OPC Client on the same PC.**
74 74  
75 -== **3.1 Run the OPC tool** ==
79 +== **Run the OPC tool** ==
76 76  
77 77  (% style="text-align:center" %)
78 78  [[image:12-3 2.png||class="img-thumbnail"]]
79 79  
80 -== **3.2 Create OPC device** ==
84 +== **Create OPC device** :[[Download>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Software/Kepware-OPCClient.zip]]. ==
81 81  
82 -Take the **OPC Quick Client.exe** tool for example. **[[Download>>doc:V-BOX.V-Net.Download.6\.Software.WebHome]] **here.
86 +The following example is taking **OPC Quick Client.exe** tool for demonstration.
83 83  
88 +(% style="text-align:center" %)
89 +[[image:WXWorkCapture_16763751224850.png]]
90 +
91 +(% style="text-align:center" %)
92 +[[image:OPCruntimelocation.png]]
93 +
94 +Try to install the following software.
95 +
96 +(% style="text-align:center" %)
97 +[[image:WXWorkCapture_17288855745498.png]]
98 +
84 84  **(1)** Run** "OPC Quick Client.exe"**
85 85  
86 86  (% style="text-align:center" %)
... ... @@ -102,11 +102,13 @@
102 102  (% style="text-align:center" %)
103 103  [[image:12-7.png||class="img-thumbnail"]]
104 104  
120 +{{info}}
121 +✎Note: If having trouble of "Failed to connect server" or not able to find V-BOX.OPCSERVER.DLL in Server Properties like the above picture, please go to the V-NET Client installation path to install the necessary OPC runtime environment.
122 +{{/info}}
123 +
105 105  (% style="text-align:center" %)
106 106  [[image:12-8.png||class="img-thumbnail"]]
107 107  
108 -✎Note: If meet with the question of "Failed to connect server" or not able to find V-BOX.OPCSERVER.DLL in Server Properties, please go to the V-NET Client installation path to install the
109 -
110 110  **(4) **Add a new group, set the group name according to your needs.
111 111  
112 112  (% style="text-align:center" %)
... ... @@ -132,6 +132,15 @@
132 132  (% style="text-align:center" %)
133 133  [[image:12-13.png||class="img-thumbnail"]]
134 134  
135 -= **4 Note** =
152 +{{info}}
153 +**✎Note:** After the OPC tool is booted up, the number of real-time monitoring tags would not dynamically increase or decrease if there are some changes on server configuration. Only those values of the existing monitoring points when the OPC starts will be updated in real time.
154 +{{/info}}
136 136  
137 -After the software is started, it would not dynamically adjust according to the increase, deletion, or configuration modification of the server monitoring point, and would only update the value of the monitoring point from time to time.
156 += [[64-bit data display OPC tool>>https://ftp.we-con.com.cn/Download/Software/MatrikonOPCExplorer.exe]] =
157 +
158 +(% class="box infomessage" %)
159 +(((
160 +**Note:** OPC Quick Client can not support 64-bit data. So please download **MatrikonOPC Explorer **to accomplish 64-bit data display.
161 +)))
162 +
163 += [[The video of 64-bit data display OPC tool >>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Video/opc%E5%B7%A5%E5%85%B7.mp4]] =
OPCruntimelocation.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +62.9 KB
Content
WXWorkCapture_16763751224850.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +195.3 KB
Content
WXWorkCapture_17288855745498.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +48.8 KB
Content