Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -110,7 +110,7 @@ 110 110 At that time using VPN Pass-through: 111 111 112 112 * ((( 113 -VPN DCHP:After the Pass-through is complete a random IP will be generated for the 39 network segment, for example 192.168.39.XXX 113 +VPN DCHP:After the Pass-through is complete a random IP will be generated for the **39** network segment, for example 192.168.**39**.XXX 114 114 ))) 115 115 * ((( 116 116 Static IP: please customize the generated IP address. ... ... @@ -156,29 +156,9 @@ 156 156 (% style="text-align:center" %) 157 157 [[image:4G.png]] 158 158 159 -= **3Operating Steps**=159 += = 160 160 161 -Select device in the device list. You can select "DHCP" or "Static IP". 162 162 163 -* If you select "DHCP", during pass-through, the PC will negotiate with the V-BOX to obtain an available IP address of PC without user intervention. 164 -* If "Static IP" is selected, the user needs to fill in the pass-through IP of the PC manually, which will be used for pass-through. 165 - 166 -(% style="text-align:center" %) 167 -[[image:static VPN.png||height="434" width="1186"]] 168 - 169 - 170 -**How to choose the pass-through IP of the PC.** 171 - 172 -For PLC and PC LANs using the different network segment. 173 - 174 -* The PLC is directly connected to the V-BOX, and all IPs that are not used by the PLC can be used in the network segment where the PLC is located. 175 -* The PLC and V-BOX are connected through a router or switch, and all free IPs not used by the PLC and other devices on the network where the PLC is located can be used in the network segment where the PLC is located. 176 - 177 -For PLC and PC LANs using the same network segment. 178 - 179 -* The PLC is directly connected to the V-BOX and all free IPs not used by the PLC and other devices on the network where the PLC is located can be used within the network segment where the PLC is located. 180 -* The PLC and V-BOX are connected through a router or switch, and all free IPs in the network segment where the PLC is located that are not used by the PLC, other devices on the network where the PLC is located, and other devices on the network where the PC is located can be used. 181 - 182 182 {{info}} 183 183 **✎Note:** If the selected IP address is occupied, the pass-through function will be failed. 184 184 {{/info}}