Changes for page PLC Protocol
Last modified by Theodore Xu on 2023/09/16 13:51
From version 1.1
edited by Leo Wei
on 2023/08/24 14:11
on 2023/08/24 14:11
Change comment:
Changed document syntax from [XWiki 2.1] to [xwiki/2.1].
To version 7.1
edited by Theodore Xu
on 2023/09/16 11:34
on 2023/09/16 11:34
Change comment:
There is no comment for this version
Summary
-
Page properties (3 modified, 0 added, 0 removed)
-
Attachments (0 modified, 9 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,0 +1,1 @@ 1 +Haiwell - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. admin1 +XWiki.AiXia - Content
-
... ... @@ -1,0 +1,76 @@ 1 +== **Haiwell** == 2 + 3 +Support Series: Haiwell S Series, A Series, C Series, T Series, H Series. 4 + 5 +**V-Box Settings** 6 + 7 +|=**Item**|=**Settings**|=**Note** 8 +|Protocol|Haiwell PLC Series| 9 +|Connection|RS232| 10 +|Baud rate|19200| 11 +|Data bit|8| 12 +|Parity|None| 13 +|Stop bit|2| 14 +|PLC station No.|0| 15 + 16 +(% style="text-align:center" %) 17 +[[image:海为 盒子串口配置.png]] 18 + 19 +**Address List** 20 + 21 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note** 22 +|(% colspan="1" rowspan="6" %)Bit|X|XDDDDD|0~~99999|Input 23 +|Y|YDDDDD|0~~99999|Output 24 +|M|MDDDDD|0~~99999|Internal Relay 25 +|T|TDDDDD|0~~99999|Timer 26 +|C|CDDDDD|0~~99999|Counter 27 +|SM|SMDDDDD|0~~99999|System Status Bit 28 +|(% colspan="1" rowspan="7" %)Word|AI|AIDDDDD|0~~99999|Analog Input 29 +|AQ|AQDDDDD|0~~99999|Analog Output 30 +|V|VDDDDD|0~~99999|Data Register 31 +|TCV|TCVDDDDD|0~~99999|Timer Current Value 32 +|CCV|CCVDDDDD|0~~99999|Counter Currnet Value 33 +|SV|SVDDDDD|0~~99999|System Register 34 +|CCVH|CCVHDD|48~~79|Special Module Parameter 35 + 36 +**PLC Settings** 37 + 38 +Create new project, and select the specific model according to the actual PLC. 39 + 40 +(% style="text-align:center" %) 41 +[[image:HHcreatenew.png]] 42 + 43 +Naming the program block, and set program password if project required, otherwise put Password as empty, then click OK to finish. 44 + 45 +(% style="text-align:center" %) 46 +[[image:HHnaming.png]] 47 + 48 +Using the RS232-USB converter cable to online the PLC connection. 49 + 50 +(% style="text-align:center" %) 51 +[[image:HHPLConline.png]] 52 + 53 +If HaiwellHappy found the PLC successfully, it would add the device into the list, and click Online. 54 + 55 +(% style="text-align:center" %) 56 +[[image:HHfoundPLC.png]] 57 + 58 +Set the project communication parameter if needed after online PLC. 59 + 60 +(% style="text-align:center" %) 61 +[[image:HHsetCOMM.png]] 62 + 63 +Process the PLC download. 64 + 65 +(% style="text-align:center" %) 66 +[[image:HHDownloadPLC2.png]] 67 + 68 +Wait for PLC download complete, then it would prompt like below. 69 + 70 +(% style="text-align:center" %) 71 +[[image:HHdownloadcomplete.png]] 72 + 73 +**Cable Wiring** 74 + 75 +(% style="text-align:center" %) 76 +[[image:Haiwell PLC Series.gif]]
- HHDownloadPLC2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +75.9 KB - Content
- HHPLConline.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +80.2 KB - Content
- HHcreatenew.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +53.2 KB - Content
- HHdownloadcomplete.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.2 KB - Content
- HHfoundPLC.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.2 KB - Content
- HHnaming.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +12.2 KB - Content
- HHsetCOMM.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +69.4 KB - Content
- Haiwell PLC Series.gif
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +7.8 KB - Content
- 海为 盒子串口配置.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +62.6 KB - Content