Changes for page PLC Protocol

Last modified by Theodore Xu on 2023/09/16 13:51

From version 3.1
edited by Theodore Xu
on 2023/09/12 13:49
Change comment: There is no comment for this version
To version 4.1
edited by Theodore Xu
on 2023/09/16 10:56
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,0 +1,1 @@
1 +Haiwell
Content
... ... @@ -1,0 +1,78 @@
1 +== Haiwell ==
2 +
3 +Support Series: Haiwell S Series, A Series, C Series, T Series, H Series.
4 +
5 +**HMI Settings**
6 +
7 +|=**Item**|=**Settings**|=**Note**
8 +|Protocol|Haiwell PLC Series|
9 +|Connection|RS232|
10 +|Baud rate|19200|
11 +|Data bit|8|
12 +|Parity|None|
13 +|Stop bit|2|
14 +|PLC station No.|0|
15 +
16 +**Address List**
17 +
18 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note**
19 +|(% colspan="1" rowspan="6" %)Bit|X|XDDDDD|0~~99999|Input
20 +|Y|YDDDDD|0~~99999|Output
21 +|M|MDDDDD|0~~99999|Internal Relay
22 +|T|TDDDDD|0~~99999|Timer
23 +|C|CDDDDD|0~~99999|Counter
24 +|SM|SMDDDDD|0~~99999|System Status Bit
25 +|(% colspan="1" rowspan="7" %)Word|AI|AIDDDDD|0~~99999|Analog Input
26 +|AQ|AQDDDDD|0~~99999|Analog Output
27 +|V|VDDDDD|0~~99999|Data Register
28 +|TCV|TCVDDDDD|0~~99999|Timer Current Value
29 +|CCV|CCVDDDDD|0~~99999|Counter Currnet Value
30 +|SV|SVDDDDD|0~~99999|System Register
31 +|CCVH|CCVHDD|48~~79|Special Module Parameter
32 +
33 +**PLC Settings**
34 +
35 +Create new project, and select the specific model according to the actual PLC.
36 +
37 +(% style="text-align:center" %)
38 +[[image:HHcreatenew.png]]
39 +
40 +Naming the program block, and set program password if project required, otherwise put Password as empty, then click OK to finish.
41 +
42 +(% style="text-align:center" %)
43 +[[image:HHnaming.png]]
44 +
45 +Program the PLC
46 +
47 +(% style="text-align:center" %)
48 +[[image:HHPrg.png]]
49 +
50 +Using the RS232-USB converter cable to online the PLC connection.
51 +
52 +(% style="text-align:center" %)
53 +[[image:HHPLConline.png]]
54 +
55 +If HaiwellHappy found the PLC successfully, it would add the device into the list, and click Online.
56 +
57 +(% style="text-align:center" %)
58 +[[image:HHfoundPLC.png]]
59 +
60 +Set the project communication parameter if needed after online PLC.
61 +
62 +(% style="text-align:center" %)
63 +[[image:HHsetCOMM.png]]
64 +
65 +Process the PLC download.
66 +
67 +(% style="text-align:center" %)
68 +[[image:HHDownloadPLC2.png]]
69 +
70 +Wait for PLC download complete, then it would prompt like below.
71 +
72 +(% style="text-align:center" %)
73 +[[image:HHdownloadcomplete.png]]
74 +
75 +**Cable Wiring**
76 +
77 +(% style="text-align:center" %)
78 +[[image:Haiwell PLC Series.gif]]