1 | = {{id name="HAllen-Bradley28Rockwell29"/}}Allen-Bradley(**Rockwell**) = | ||
2 | |||
3 | == {{id name="HDF1AdvancedA0A0Serial"/}}**DF1 Advanced Serial** == | ||
4 | |||
5 | MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05; PLC-5 | ||
6 | |||
7 | **1) V-Box Settings** | ||
8 | |||
9 | |=Item|=Recommended |=Note | ||
10 | |=Protocol|Allen Bradley DF1 Advanced| | ||
11 | |=Connection|RS232| | ||
12 | |=Baud rate|19200| | ||
13 | |=Stop bits|1| | ||
14 | |=Data bits|8| | ||
15 | |=Parity|None| | ||
16 | |=PLC Station No.|1| | ||
17 | |=HMI Station No.|0| | ||
18 | |||
19 | **2) Address List** | ||
20 | |||
21 | |=**Type**|=**Device registers**|=**Format**|=**Range**|=Note | ||
22 | |(% rowspan="7" %)Bit|I1|I1ddd.dd|0.0~~255.15|Only able to communicate with file number I1 | ||
23 | |O0|O0ddd.dd|0.0~~255.15|Only able to communicate with file number O0 | ||
24 | |S2|S2ddd.dd|0.0~~255.15|Only able to communicate with file number S2 | ||
25 | |B3|B3ddd.dd|0.0~~255.15|Only able to communicate with file number B3 | ||
26 | |BN|BNddddd.dd|0.0~~99255.15|((( | ||
27 | Bit data file B0~~B99 | ||
28 | |||
29 | First two digits is for file number | ||
30 | |||
31 | For example, BN13001.00 represents file number B13, address 001, the 0th bit. | ||
32 | ))) | ||
33 | |N7|N7ddd.dd|0.0~~255.15|Only able to communicate with file number N7 | ||
34 | |NN|NNddddd.dd|0.0~~99255.15|((( | ||
35 | Integer data file bit format N0~~N99 | ||
36 | |||
37 | First two digits is for file number | ||
38 | |||
39 | For example, NN13001.00 represents file number N13, address 001, the 0th bit. | ||
40 | ))) | ||
41 | |(% rowspan="11" %)Word|S2|S2ddd|0~~255|Only able to communicate with file number S2 | ||
42 | |T4S|T4Sddd|0~~255|Only able to communicate with file number T4 (Timer Preset Value) | ||
43 | |T4P|T4Pddd|0~~255|Only able to communicate with file number T4 (Timer Accumulator Value) | ||
44 | |TNS|TNSddddd|0~~99255|((( | ||
45 | Timer Preset Value | ||
46 | |||
47 | First two digits is for file number | ||
48 | |||
49 | For example, TNS99255 represents file number T99, address 255. | ||
50 | ))) | ||
51 | |TNP|TNPddddd|0~~99255|((( | ||
52 | Timer Accumulator Value | ||
53 | |||
54 | First two digits is for file number | ||
55 | |||
56 | For example, TNP99255 represents file number T99, address 255. | ||
57 | ))) | ||
58 | |C5S|C5Sddd|0~~255|Only able to communicate with file number C5 (Counter Preset Value) | ||
59 | |C5P|C5Pddd|0~~255|Only able to communicate with file number C5 (Counter Accumulator Value) | ||
60 | |CNS|CNSddddd|0~~99255|((( | ||
61 | Counter Preset Value | ||
62 | |||
63 | First two digits is for file number | ||
64 | |||
65 | For example, CNS99255 represents file number C99, address 255. | ||
66 | ))) | ||
67 | |CNP|CNPddddd|0~~99255|((( | ||
68 | Counter Accumulator Value | ||
69 | |||
70 | First two digits is for file number | ||
71 | |||
72 | For example, CNP99255 represents file number C99, address 255. | ||
73 | ))) | ||
74 | |N7|N7ddd|0~~255|Only able to communicate with file number N7 | ||
75 | |NN|NNddd|0~~99255|((( | ||
76 | Integer data file | ||
77 | |||
78 | First two digits is for file number | ||
79 | |||
80 | For example, NN99255 represents file number N99, address 255. | ||
81 | ))) | ||
82 | |(% rowspan="3" %)Double Word|F8|F8ddd|0~~255|Only able to communicate with file number N7 | ||
83 | |FN|FNddddd|0~~99255|((( | ||
84 | Floating point data file | ||
85 | |||
86 | First two digits is for file number | ||
87 | |||
88 | For example, FN99255 represents file number F99, address 255. | ||
89 | ))) | ||
90 | |LN|LNddddd|0~~99255|Long | ||
91 | |||
92 | **3) Cable Wiring** | ||
93 | |||
94 | {{id name="IABRS232.gif"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_25f468ac2575918b.gif||alt="ABRS232.gif" height="247" width="400"]] | ||
95 | |||
96 | {{id name="cke_bm_5621S"/}}{{id name="HMicroLogixA0Protocol"/}}** ** | ||
97 | |||
98 | == {{id name="HMicroLogixA0Serial"/}}**MicroLogix Serial** == | ||
99 | |||
100 | MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 | ||
101 | |||
102 | **1)V-BOX setting** | ||
103 | |||
104 | |**Item**|**Settings**|**Note** | ||
105 | |Protocol|Allen-Bradley DF1 Advanced| | ||
106 | |Connection|RS232| | ||
107 | |Baud rate|19200| | ||
108 | |Data bit|8| | ||
109 | |Parity|None| | ||
110 | |Stop bit|1| | ||
111 | |PLC station No.|1| | ||
112 | |||
113 | **2)Address List** | ||
114 | |||
115 | |**Type**|**Device registers**|**Format**|**Range**|**Note** | ||
116 | |(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15| | ||
117 | |O|O d.d|0.0~~255.15| | ||
118 | |B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex) | ||
119 | |S|S d.d|0.0~~255.15| | ||
120 | |N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex) | ||
121 | |(% rowspan="9" %)Word|S|S d|0~~255| | ||
122 | |TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex) | ||
123 | |TP|TP nnhh|0~~ffff | ||
124 | |CS|CS nnhh|0~~ffff | ||
125 | |CP|CP nnhh|0~~ffff | ||
126 | |N|N nnhh|0~~ffff | ||
127 | |C|C nnhh|0~~ffff | ||
128 | |T|T nnhh|0~~ffff | ||
129 | |R|R nnhh|0~~ffff | ||
130 | |||
131 | {{id name="Iimage-20220824152928-1.png"/}}**3)Configure the communication protocol**[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_3e790cb11779d822.png||alt="image-20220824152928-1.png" height="1010" width="1920"]] | ||
132 | |||
133 | **4)Configure the communication protocol** | ||
134 | |||
135 | {{id name="Iimage-20220824110724-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_faf98d75129f59e9.png||alt="image-20220824110724-1.png" height="326" width="548"]] | ||
136 | |||
137 | == {{id name="HMicro850_FreeTagEthernet"/}}**Micro850_FreeTag Ethernet** == | ||
138 | |||
139 | This example introduces the establishment of Ethernet communication between Wecon V-box and CompactLogix L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring. | ||
140 | |||
141 | **Software configuration of PLC** | ||
142 | |||
143 | **1)PLC programming software** | ||
144 | |||
145 | {{id name="Iimage-20220714162600-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dba9ec452ee41c5.png||alt="image-20220714162600-1.png" height="527" width="437"]] | ||
146 | |||
147 | **2)New PLC project** | ||
148 | |||
149 | Click New Project and select the PLC model. | ||
150 | |||
151 | {{id name="Iimage-20220714162617-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_54a31bd52186c53c.png||alt="image-20220714162617-2.png" height="434" width="803"]] | ||
152 | |||
153 | |||
154 | |||
155 | {{id name="Iimage-20220714162652-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_5d52824614585e13.png||alt="image-20220714162652-4.png" height="591" width="732"]] | ||
156 | |||
157 | **3)Set Ethernet parameters** | ||
158 | |||
159 | Follow the steps below to configure Ethernet parameters | ||
160 | |||
161 | PLC IP address:192.168.40.101 | ||
162 | |||
163 | default gateway:192.168.40.1 | ||
164 | |||
165 | subnet mask:255.255.255.0 | ||
166 | |||
167 | {{id name="Iimage-20220714162713-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_cea23d115ccaaa63.png||alt="image-20220714162713-5.png" height="868" width="1919"]] | ||
168 | |||
169 | |||
170 | |||
171 | **V-box software configuration** | ||
172 | |||
173 | **1)V-box programming software** | ||
174 | |||
175 | {{id name="Iimage-20220714162725-6.png"/}} [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_65a3ecdb93694966.png||alt="image-20220714162725-6.png" height="441" width="731"]] | ||
176 | |||
177 | **2)Configure device network** | ||
178 | |||
179 | {{id name="Iimage-20220714115308-8.png"/}}Click the Configuration Download button[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ad012010777dc078.png||alt="image-20220714115308-8.png" height="22" width="15"]] , It is used to configure the device network, update the device time, obtain the device machine code, check the device network, etc. | ||
180 | |||
181 | In the example below, the IP address of V-Box is configured as 192.168.40.66, and the networking method is 4G connection | ||
182 | |||
183 | {{id name="Iimage-20220714162737-7.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_a2b83bb70af39146.png||alt="image-20220714162737-7.png" height="736" width="1370"]] | ||
184 | |||
185 | |||
186 | |||
187 | **3)V-net add device** | ||
188 | |||
189 | {{id name="Iimage-20220714162752-8.png"/}}Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device. [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_bff671605e8a8f53.png||alt="image-20220714162752-8.png" height="793" width="1470"]] | ||
190 | |||
191 | |||
192 | |||
193 | **4)Set communication port parameters** | ||
194 | |||
195 | In the device list on the left, find the Vbox that communicates with the L1769, click it and select configuration,communication port configuration in the main interface to add a communication protocol. | ||
196 | |||
197 | {{id name="Iimage-20220714162805-9.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_acc2b9d2e75a2791.png||alt="image-20220714162805-9.png" height="792" width="1471"]] | ||
198 | |||
199 | The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818. | ||
200 | |||
201 | {{id name="Iimage-20220824164346-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_68274e3dec90a425.png||alt="image-20220824164346-1.png" height="553" width="991"]] | ||
202 | |||
203 | {{id name="Iimage-20220714143838-2.png"/}}{{id name="Iimage-20220714162827-11.png"/}}After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_bff5c072d145b8c.png||alt="image-20220714143838-2.png" height="27" width="30"]] icon add label.[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_c8c6550cf2a1e96b.png||alt="image-20220714162827-11.png" height="574" width="1054"]] | ||
204 | |||
205 | **5)Engineering production** | ||
206 | |||
207 | According to your own needs, use the V-NET client software to edit the required data monitoring points. | ||
208 | |||
209 | {{id name="Iimage-20220714162841-12.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce5d38d21d89c3e3.png||alt="image-20220714162841-12.png" height="478" width="1614"]] | ||
210 | |||
211 | **hardware connection** | ||
212 | |||
213 | **1)Hardware wiring diagram** | ||
214 | |||
215 | This example introduces Wecon V-box with Allen-Bradley L1769 PLC to establish communication through Ethernet. The connection diagram is as follows: | ||
216 | |||
217 | {{id name="Iimage-20220714162856-13.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_43bb560ec0411230.png||alt="image-20220714162856-13.png" height="322" width="693"]] | ||
218 | |||
219 | The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC. | ||
220 | |||
221 | == {{id name="HMicro850_FreeTagEthernetFF08newFF09"/}}**Micro850_FreeTag Ethernet(new)** == | ||
222 | |||
223 | This example introduces the establishment of Ethernet communication between Wecon V-box and 2080-LC50-48QWB,Micro850. It is introduced through three parts: PLC software configuration, V-box software configuration. | ||
224 | |||
225 | **Software configuration of PLC** | ||
226 | |||
227 | **1)PLC programming software:Connected Components Workbench™** | ||
228 | |||
229 | {{id name="Isoftware.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_3711a5e1c2a7f00f.png||alt="software.png" height="485" width="378"]] | ||
230 | |||
231 | **2)New PLC project** | ||
232 | |||
233 | Click New Project and select the PLC model. | ||
234 | |||
235 | {{id name="Iprojectcreate.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_6c0da8fb6efff6c5.png||alt="project create.png" height="806" width="901"]] | ||
236 | |||
237 | **3)Set Ethernet parameters** | ||
238 | |||
239 | Follow the steps below to configure Ethernet parameters | ||
240 | |||
241 | PLC IP address:192.168.39.56 | ||
242 | |||
243 | default gateway:192.168.39.1 | ||
244 | |||
245 | subnet mask:255.255.255.0 | ||
246 | |||
247 | {{id name="IEthernet.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_c79ec9884ea8fe28.png||alt="Ethernet.png" height="656" width="935"]] | ||
248 | |||
249 | **4)connect PLC** | ||
250 | |||
251 | **When downloading the setting, need to change the status of the PLC to PRG** | ||
252 | |||
253 | {{id name="Iconneabplc.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_85b0c5a416b2a77d.png||alt="conne ab plc.png" height="765" width="696"]] | ||
254 | |||
255 | **V-box software configuration** | ||
256 | |||
257 | **1)V-box programming software** | ||
258 | |||
259 | {{id name="Iv-netclientvers.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac791772fd34e1a0.png||alt="v-net client vers.png" height="277" width="281"]] | ||
260 | |||
261 | **2)Set communication port parameters** | ||
262 | |||
263 | In the device list on the left, find the Vbox that communicates with the L1769, click it and select configuration,communication port configuration in the main interface to add a communication protocol. | ||
264 | |||
265 | {{id name="IV-NET_Client_t2Rg2wpSoY.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_6af9507fa57e3f6e.png||alt="V-NET_Client_t2Rg2wpSoY.png" height="791" width="1086"]] | ||
266 | |||
267 | The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818. | ||
268 | |||
269 | {{id name="IV-NET_Client_communication.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ecdfe646ccfb5f9f.png||alt="V-NET_Client_communication.png" height="601" width="894"]] | ||
270 | |||
271 | {{id name="cke_bm_1950S"/}}Export variables from PLC, select CSV file, comma delimited. | ||
272 | |||
273 | {{id name="Iexport1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_306bf46ce1a5a0d3.png||alt="export1.png" height="613" width="604"]] | ||
274 | |||
275 | {{id name="ICCW.Shell_E5Cwj4tUL3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_c9e367a57c3e9201.png||alt="CCW.Shell_E5Cwj4tUL3.png" height="278" width="915"]] | ||
276 | |||
277 | {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FV-BOX2FV-Net2FTraining2F12520Communication2FWebHome2Fimage-20220714143838-2.png3Frev3D1.1"/}}After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:https://docs.we-con.com.cn/bin/download/V-BOX/V-Net/Training/1%20Communication/WebHome/image-20220714143838-2.png?rev=1.1||alt="image-20220714143838-2.png" height="38" width="76"]] icon add label. | ||
278 | |||
279 | {{id name="IV-NET_Client_TNBuqy7T5r.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_820dbb012d8d584d.png||alt="V-NET_Client_TNBuqy7T5r.png" height="449" width="952"]] | ||
280 | |||
281 | **3)Engineering production** | ||
282 | |||
283 | According to your own needs, use the V-NET client software to edit the required data monitoring points. | ||
284 | |||
285 | {{id name="IV-NET_Client_KOR0AHEA4M.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_32fe301a04258d72.png||alt="V-NET_Client_KOR0AHEA4M.png" height="182" width="825"]] | ||
286 | |||
287 | |||
288 | |||
289 | == {{id name="HEthernetDF1"/}}**Ethernet DF1** == | ||
290 | |||
291 | [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]] |