Hide last authors
author | version | line-number | content |
---|---|---|---|
![]() |
19.1 | 1 | (% class="wikigeneratedid" id="HDVPserial" %) |
2 | (% id="cke_bm_111267S" style="display:none" %)** ** | ||
![]() |
2.1 | 3 | |
![]() |
21.1 | 4 | == **DVP Serial** == |
![]() |
20.1 | 5 | |
![]() |
19.1 | 6 | (% class="wikigeneratedid" %) |
![]() |
15.1 | 7 | Supoort Series: DELTA DVP EH/ES/SS/EX/EH2/SV/SA/SC/SX |
![]() |
2.1 | 8 | |
![]() |
15.1 | 9 | **V-BOX Settings** |
![]() |
2.1 | 10 | |
11 | |=**Items**|=**Settings**|=**Note** | ||
![]() |
15.1 | 12 | |Protocol|DELTA DVP PROTOCOL| |
13 | |Connection|RS232| | ||
14 | |Baud Rate|9600| | ||
15 | |Stop Bit|1| | ||
16 | |Data Bit|7| | ||
17 | |Parity|EVEN| | ||
![]() |
2.1 | 18 | |Device No.|1| |
19 | |||
![]() |
15.1 | 20 | **Address List** |
![]() |
2.1 | 21 | |
![]() |
15.1 | 22 | |=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note** |
23 | |Bit|X|X|X d|0~~303237| | ||
24 | |Bit|Y|Y|Y d|0~~303237| | ||
25 | |Bit|M|M|M d|0~~99999| | ||
26 | |Bit|T|T|T d|0~~99999| | ||
27 | |Bit|C|C|T d|0~~99999| | ||
28 | |Bit|S|S|T d|0~~99999| | ||
29 | |Word|D|D|D d|0~~99999| | ||
30 | |Word|T|T|T d|0~~99999| | ||
31 | |Word|C|C|C d|0~~99999| | ||
32 | |||
33 | **Wiring Diagram** | ||
34 | |||
35 | [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_96f8e9b105b4268c.png||alt="Delta DVP PROTOCOLSerial232.png" height="247" width="400"]] | ||
36 | |||
37 | == **DVP Ethernet** == | ||
38 | |||
39 | Supported Series: Delta DVP ES2/EX2/SS2/SA2/SX2/SE Controller | ||
40 | |||
41 | **V-BOX Settings** | ||
42 | |||
43 | |=**Items**|=**Settings**|=**Note** | ||
44 | |Protocol|DELTA DVP Modbus TCP| | ||
45 | |Connection|Ethernet| | ||
46 | |Port No.|502|Must be the same as the PLC setting | ||
47 | |PLC station No.|0|Must be the same as the PLC setting | ||
48 | |||
![]() |
18.1 | 49 | (% style="text-align:center" %) |
50 | [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_514e38138de7059.png||alt="DVPEthernetVNETPortocol.png" height="493" width="729"]] | ||
51 | |||
![]() |
15.1 | 52 | **Address List ** |
53 | |||
![]() |
2.1 | 54 | |=**Type**|=**Device registers**|=**VBox registers**|=**Format**|=**Range**|=**Note** |
55 | |Bit|X|X|X OOO|0~~377| | ||
56 | |Bit|Y|Y|Y OOO|0~~377| | ||
57 | |Bit|M0|M0|M0DDDD|0~~1535| | ||
58 | |Bit|M1|M1|M1DDDD|1536~~4096| | ||
59 | |Bit|T|T|TDDD|0~~255| | ||
60 | |Bit|C|C|CDDD|0~~255| | ||
61 | |Bit|S|S|SDDDD|0~~1023| | ||
62 | |Word|D0|D0|D0DDDD|0~~4095| | ||
63 | |Word|D1|D1|D1DDDD|4096~~11999| | ||
64 | |Word|T|T|TDDD|0~~255| | ||
65 | |Word|C|C|CDDD|0~~199| | ||
66 | |Double Word|HC|HC|HCDDD|200~~255| | ||
67 | |||
![]() |
15.1 | 68 | **PLC Setting:** |
![]() |
2.1 | 69 | |
70 | ~1. Create new project in Delta WPL Soft, and click Setting to open the communication settings: | ||
71 | |||
![]() |
15.1 | 72 | [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_c5e594a6b73bdd68.png||alt="DVPEthernetWPLSoft2.png" height="727" width="1366"]] |
![]() |
2.1 | 73 | |
74 | 2. Set up the communication type and PLC IP: | ||
75 | |||
![]() |
15.1 | 76 | [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_92343d448762200c.png||alt="DVPEthernetSetup.png" height="592" width="346"]] |
![]() |
2.1 | 77 | |
78 | 3. Click OK and save the settings. Then click Communication on toolbar, then click Transfer Setup to open new window: | ||
79 | |||
80 | {{id name="IDVPEthernetTransfer.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_a24e318f1e5f0839.png||alt="DVPEthernetTransfer.png" height="726" width="1366"]] | ||
81 | |||
82 | 4. Select Communication Mode as PC => PLC to download or select PC <=PLC to upload: | ||
83 | |||
![]() |
15.1 | 84 | [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ae301f5422be2294.png||alt="DVPEthernetPLCtoPC.png" height="303" width="308"]] |
![]() |
2.1 | 85 | |
86 | 5. Click Auto-Search Ethernet Module to find the PLC on the same LAN network: | ||
87 | |||
88 | {{id name="IDVPEthernetAutoSearch.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_e2c32050bbe425bc.png||alt="DVPEthernetAutoSearch.png" height="723" width="1366"]] | ||
89 | |||
90 | |||
![]() |
15.1 | 91 | == **AS Series Serial** == |
![]() |
2.1 | 92 | |
![]() |
15.1 | 93 | Supported Series: Delta AS200/AS300 |
![]() |
2.1 | 94 | |
![]() |
15.1 | 95 | **V-BOX Settings** |
![]() |
2.1 | 96 | |
![]() |
15.1 | 97 | |**Item**|**Settings**|**Note** |
98 | |Protocol|DELTA AS300 MODBUS RTU| | ||
99 | |Connection|RS485| | ||
100 | |Baud rate|9600| | ||
101 | |Data bit|8| | ||
102 | |Parity|NONE| | ||
103 | |Stop bit|1| | ||
104 | |PLC station No.|1| | ||
![]() |
2.1 | 105 | |
![]() |
15.1 | 106 | **Address List** |
![]() |
2.1 | 107 | |
![]() |
15.1 | 108 | |=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note** |
109 | |(% colspan="1" rowspan="9" %)Bit|X|Xdd.dd|0~~63.15|Read only | ||
110 | |Y|Ydd.dd|0~~63.15| | ||
111 | |D|Dddddd|0~~29999| | ||
112 | |M|Mdddd|0~~8191| | ||
113 | |SM|SMdddd|0~~4095| | ||
114 | |S|Sdddd|0~~2047| | ||
115 | |T|Tddd|0~~511| | ||
116 | |C|Cddd|0~~511| | ||
117 | |HC|HCddd|0~~255|Double Word | ||
118 | |(% colspan="1" rowspan="7" %)Word|X|Xdd|0~~63| | ||
119 | |Y|Ydd|0~~63| | ||
120 | |SR|SRdddd|0~~2047|Special register | ||
121 | |D|Dddddd|0~~29999| | ||
122 | |T|Tddd|0~~511| | ||
123 | |C|Cddd|0~~511| | ||
124 | |E|Ed|0~~9| | ||
![]() |
2.1 | 125 | |
![]() |
15.1 | 126 | **PLC Settings** |
![]() |
2.1 | 127 | |
![]() |
15.1 | 128 | Create project |
![]() |
2.1 | 129 | |
![]() |
15.1 | 130 | (% style="text-align:center" %) |
131 | [[image:台达1.png]] | ||
![]() |
2.1 | 132 | |
![]() |
15.1 | 133 | Open the tool COMMGR, to communicate with PLC, if know the IP, we can directly click Add to input PLC IP. Or search the PLC IP from LAN. |
134 | |||
135 | (% style="text-align:center" %) | ||
136 | [[image:1696906027584-350.png]] | ||
137 | |||
138 | Double click the HWCONFIG to open the communication settings window. | ||
139 | |||
140 | (% style="text-align:center" %) | ||
141 | [[image:台达3.png]] | ||
142 | |||
143 | Expand the Project Tree, open the hardware configuration, double click the PLC icon. | ||
144 | |||
145 | (% style="text-align:center" %) | ||
146 | [[image:台达4.png]] | ||
147 | |||
148 | Click COM1 Port Setting, the default Modbus mode is ASCII, need to change to RTU. | ||
149 | |||
150 | (% style="text-align:center" %) | ||
151 | [[image:台达5.png]] | ||
152 | |||
153 | |||
154 | Click Ethernet Port Basic Setting, set the PLC IP and Gateway. Make sure the IP and Gateway is same segment. Then download into PLC. | ||
155 | |||
156 | (% style="text-align:center" %) | ||
157 | [[image:台达6.png]] | ||
158 | |||
159 | **Cable Wiring** | ||
160 | |||
![]() |
16.1 | 161 | (% id="cke_bm_36592S" style="display:none" %) (%%)Pin Definition Diagram |
![]() |
15.1 | 162 | |
![]() |
16.1 | 163 | [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_daa33fcae616e61c.png||alt="image-20220831155157-3.png" height="181" width="320"]] |
![]() |
15.1 | 164 | |
165 | == **AS Series Ethernet** == | ||
166 | |||
![]() |
2.1 | 167 | |=**Items**|=**Settings**|=**Note** |
168 | |Protocol|DELTA AS300 MODBUS TCP| | ||
169 | |Connection|Ethernet| | ||
170 | |Port No.|502| | ||
171 | |Device No.|1| | ||
172 | |HMI No.|0| | ||
173 | |||
![]() |
15.1 | 174 | **Address List** |
![]() |
2.1 | 175 | |
176 | |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** | ||
177 | |Bit|X|X|X d|0~~63| | ||
178 | |Bit|Y|Y|Y d|0~~63| | ||
179 | |Bit|D|D|D d|0~~29999| | ||
180 | |Bit|M|M|M d|0~~8191| | ||
181 | |Bit|SM|SM|SM d|0~~4095| | ||
182 | |Bit|S|S|S h|0~~2047| | ||
183 | |Bit|T|T|T d|0~~511| | ||
184 | |Bit|C|C|C d|0~~511| | ||
185 | |Bit|HC|HC|HC d|0~~255| | ||
186 | |Word|X|X|X h|0~~63| | ||
187 | |Word|Y|Y|Y d|0~~63| | ||
188 | |Word|SR|SR|SR d|0~~2047| | ||
189 | |Word|D|D|D d|0~~29999| | ||
190 | |Word|T|T|T d|0~~511| | ||
191 | |Word|C|C|C h|0~~511| | ||
192 | |Word|E|E|E d|0~~9| | ||
193 | |||
![]() |
16.1 | 194 | **PLC Setting** |
![]() |
2.1 | 195 | |
![]() |
16.1 | 196 | 1.Open COMMGR ,[Add]→[Driver Name] Driver1→[Connection Setup]→[Type] Ethernet→[Ethernet Card] →[Description] Realtek PCIe GBE Family Controller→[Search] PC and PLC are in |
197 | the same LAN, click the corresponding PLC IP searched.→[OK] | ||
198 | |||
199 | (% style="text-align:center" %) | ||
200 | [[image:2.1.png]] | ||
201 | |||
202 | 2. Open ISPSoft,[Project]→Double click[HWCONFIG] | ||
203 | |||
204 | (% style="text-align:center" %) | ||
205 | [[image:台达2.2.png]] | ||
206 | |||
207 | PLC Default Parameters: | ||
208 | [Device]→[Hardware Configuration]→[CPU(AS332T-A)]→[Hardware Configuration]→[General] →[Ethernet Port Basic Setting]: [IP Address]192.168.40.122, [Subnet Mask]255.255.255.0,[Gateway] | ||
209 | 192.168.40.1→[Download] | ||
210 | |||
211 | (% style="text-align:center" %) | ||
212 | [[image:台达2.3-.png]] | ||
213 | |||
214 | (% style="text-align:center" %) | ||
215 | [[image:台达2.4.png]] | ||
216 | |||
![]() |
15.1 | 217 | **Cable Wiring** |
![]() |
2.1 | 218 | |
219 | Figure | ||
220 | |||
![]() |
15.1 | 221 | [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_f2c92ecd57ebfbd0.png||alt="image-20220831155101-1.png" height="262" width="118"]] [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_32ea98dfbc23a591.png||alt="image-20220831160055-5.png" height="198" width="455"]] |