Changes for page Inovance
Last modified by Theodore Xu on 2023/11/08 09:51
From version 6.1
edited by Leo Wei
on 2023/08/24 14:11
on 2023/08/24 14:11
Change comment:
There is no comment for this version
To version 10.1
edited by Theodore Xu
on 2023/10/27 17:32
on 2023/10/27 17:32
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 8 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. admin1 +XWiki.AiXia - Content
-
... ... @@ -1,9 +1,7 @@ 1 -= {{idname="HInovance"/}}Inovance=1 +== **H3U (serial)** == 2 2 3 - == {{id name="HH3Userial"/}}**H3Userial**==3 +**V-BOX Settings** 4 4 5 -**1)V-BOX Settings** 6 - 7 7 |**Item**|**Settings**|**Note** 8 8 |Protocol|INOVANCE H3U PLC| 9 9 |Connection|RS422| ... ... @@ -13,37 +13,135 @@ 13 13 |Stop bit|1| 14 14 |PLC station No.|0| 15 15 16 -** 2)Address List**14 +**Address List** 17 17 18 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 19 -|Bit|X|X|X o|0~~303237| 20 -|Bit|Y|Y|Y o|0~~303237| 21 -|Bit|M|M|M d|0~~99999| 22 -|Bit|T|T|T d|0~~99999| 23 -|Bit|C|C|C d|0~~99999| 24 -|Bit|SM|SM|SM d|8000~~999| 25 -|Bit|S|T|S d|0~~99999| 26 -|Bit|Lamp|Lamp|Lamp d|0~~0| 27 -|Word|X|X|X o|0~~303237| 28 -|Word|Y|Y|Y o|0~~303237| 29 -|Word|M|M|M d|0~~99999| 30 -|Word|T|T|T d|0~~99999| 31 -|Word|C|C|C d|0~~199| 32 -|Word|D|D|D d|0~~7999| 33 -|Word|S|S|S d|0~~99999| 34 -|Word|SD|SD|SD d|8000~~9999| 35 -|Word|R|R|R d|0~~32767| 16 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note** 17 +|Bit|X|X OOOOOO|0~~303237| 18 +|Bit|Y|Y OOOOOO|0~~303237| 19 +|Bit|M|M DDDDD|0~~99999| 20 +|Bit|T|T DDDDD|0~~99999| 21 +|Bit|C|C DDDDD|0~~99999| 22 +|Bit|SM|SM DDDD|8000~~9999| 23 +|Bit|S|S DDDDD|0~~99999| 24 +|Bit|Lamp|Lamp0|0~~0|((( 25 +Communication Indicator Lamp 36 36 37 - **3)Configurethecommunication protocol**27 +0: Connected 38 38 39 -{{id name="Iimage-20220831164626-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_a6744e27785ffa46.png||alt="image-20220831164626-1.png" height="708" width="1674"]] 29 +1: Disconnected 30 +))) 31 +|Word|X|X OOOOOO|0~~303237| 32 +|Word|Y|Y OOOOOO|0~~303237| 33 +|Word|M|M DDDDD|0~~99999| 34 +|Word|T|T DDDDD|0~~99999| 35 +|Word|C|C DDD|0~~199| 36 +|Word|D|D DDDD|0~~7999| 37 +|Word|S|S DDDDD|0~~99999| 38 +|Word|SD|SD DDDD|8000~~9999| 39 +|Word|R|R DDDDD|0~~32767| 40 +|Double Word|CH|CH DDD|200~~255 40 40 41 -** 4)CableWiring**42 +**PLC Settings** 42 42 44 +Create the new project, and select Series and models as H3U. 45 + 46 +(% style="text-align:center" %) 47 +[[image:AutoShop01createprj.png]] 48 + 49 +Configure the COM0 settings from [Communication Config]-[COM0(Download/HMI Monitor Protocol)], the default communication parameters we could see it is 9600,1,7,EVEN. After setting finished, click OK to save the settings. 50 + 51 +(% style="text-align:center" %) 52 +[[image:AutoShop02setupCOM0.png]] 53 + 54 +Program the PLC project, and click compile. 55 + 56 +(% style="text-align:center" %) 57 +[[image:AutoShopPrg.png]] 58 + 59 + 60 +Connect PLC with PC via USB cable or RS422-USB converter cable, and test the connection status. If it shows like the below, which means the connection is set up successfully. And click OK. 61 + 62 +(% style="text-align:center" %) 63 +[[image:AutoShop03pcconnect.png]] 64 + 65 +Download PLC program into PLC. 66 + 67 +(% style="text-align:center" %) 68 +[[image:AutoShop04Download.png]] 69 + 70 +**Cable Wiring** 71 + 43 43 Figure 44 44 45 - {{id name="Iimage-20220831164646-2.png"/}}{{id name="Iimage-20220831164700-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_addddf687771b2a9.png||alt="image-20220831164646-2.png" height="258" width="100"]] [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_63add2bcd04520f6.png||alt="image-20220831164700-3.png" height="191" width="496"]]74 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_addddf687771b2a9.png||alt="image-20220831164646-2.png" height="258" width="100"]] [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_63add2bcd04520f6.png||alt="image-20220831164700-3.png" height="191" width="496"]] 46 46 47 47 Pin Definition Diagram 48 48 49 -{{id name="Iimage-20220831164731-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d332c6eb75105461.png||alt="image-20220831164731-4.png" height="168" width="330"]] 78 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d332c6eb75105461.png||alt="image-20220831164731-4.png" height="168" width="330"]] 79 + 80 +== **H3U Ethernet** == 81 + 82 +Support Series: INOVANCE H3U Series 83 + 84 +**HMI Settings** 85 + 86 +|=**Item**|=**Settings**|=**Note** 87 +|Protocol|INOVANCE H3U PLC Ethernet| 88 +|Connection|Ethernet| 89 +|Port No.|502| 90 +|Device No.|1| 91 +|HMI No.|0| 92 + 93 +**Address List** 94 + 95 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note** 96 +|Bit|M|M DDDD|0~~8511| 97 +|Bit|SM|SM DDDD|0~~1023| 98 +|Bit|S|S DDDD|0~~4095| 99 +|Bit|T|T DDD|0~~511| 100 +|Bit|C|C DDD|0~~255| 101 +|Bit|X|X OOO|0~~571| 102 +|Bit|Y|Y OOO|0~~571| 103 +|Word|D|D DDDD|0~~8511| 104 +|Word|SD |SD DDDD|0~~1023| 105 +|Word|R|R DDDDD|0~~32767| 106 +|Word|T|T DDD|0~~255| 107 +|Word|C|C DDD|0~~199| 108 +|Double Word|C|C DDD|200~~255| 109 + 110 +**PLC Settings** 111 + 112 +Create the new project, and select Series and models as H3U. 113 + 114 +(% style="text-align:center" %) 115 +[[image:AutoShop01createprj.png]] 116 + 117 +Configure the Ethernet settings from [Communication Config]-[Ethernet]. 118 + 119 +(% style="text-align:center" %) 120 +[[image:AutoShopEthernetSetup.png]] 121 + 122 +Program the PLC project, and click compile. 123 + 124 +(% style="text-align:center" %) 125 +[[image:AutoShopPrg.png]] 126 + 127 +Connect PLC with PC via USB cable or RS422-USB converter cable, and test the connection status. If it shows like the below, which means the connection is set up successfully. And click OK. 128 + 129 +(% style="text-align:center" %) 130 +[[image:AutoShop03pcconnect.png]] 131 + 132 +If don't want to change the IP, user could also read the IP parameter from the PLC after the PC connection is set up successfully. 133 + 134 +(% style="text-align:center" %) 135 +[[image:AutoShopreadip.png]] 136 + 137 +Download PLC program into PLC. 138 + 139 +(% style="text-align:center" %) 140 +[[image:AutoShop04Download.png]] 141 + 142 +**Cable Wiring** 143 + 144 +(% style="text-align:center" %) 145 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png]]
- AutoShop01createprj.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +46.4 KB - Content
- AutoShop02setupCOM0.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +54.1 KB - Content
- AutoShop03pcconnect.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +65.8 KB - Content
- AutoShop04Download.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +79.6 KB - Content
- AutoShopEthernetSetup.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +60.3 KB - Content
- AutoShopPrg.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +44.5 KB - Content
- AutoShopreadip.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.2 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +107.1 KB - Content