Inovance
Version 7.1 by Theodore Xu on 2023/10/26 16:05
Inovance
H3U serial
V-BOX Settings
Item | Settings | Note |
Protocol | INOVANCE H3U PLC | |
Connection | RS422 | |
Baud rate | 9600 | |
Data bit | 7 | |
Parity | EVEN | |
Stop bit | 1 | |
PLC station No. | 0 |
Address List
Type | Device registers | HMI registers | Format | Range | Note |
Bit | X | X | X o | 0~303237 | |
Bit | Y | Y | Y o | 0~303237 | |
Bit | M | M | M d | 0~99999 | |
Bit | T | T | T d | 0~99999 | |
Bit | C | C | C d | 0~99999 | |
Bit | SM | SM | SM d | 8000~999 | |
Bit | S | T | S d | 0~99999 | |
Bit | Lamp | Lamp | Lamp d | 0~0 | |
Word | X | X | X o | 0~303237 | |
Word | Y | Y | Y o | 0~303237 | |
Word | M | M | M d | 0~99999 | |
Word | T | T | T d | 0~99999 | |
Word | C | C | C d | 0~199 | |
Word | D | D | D d | 0~7999 | |
Word | S | S | S d | 0~99999 | |
Word | SD | SD | SD d | 8000~9999 | |
Word | R | R | R d | 0~32767 |
Configure the communication protocol
Cable Wiring
Figure
Pin Definition Diagram