| 1 | = KV-5000 Ethernet = | ||
| 2 | |||
| 3 | Supported Series: KEYENCE KV-5000, KV-5500 models | ||
| 4 | |||
| 5 | **V-Box Settings** | ||
| 6 | |||
| 7 | |=**Item**|=**Settings**|=**Note** | ||
| 8 | |Protocol|KEYENCE KV-5000(Ethernet)| | ||
| 9 | |Connection|Ethernet| | ||
| 10 | |Port No.|8501|Need to be the same as PLC settings | ||
| 11 | |PLC station No.|0| | ||
| 12 | |||
| 13 | (% style="text-align:center" %) | ||
| 14 | [[image:基恩士1.1.png]] | ||
| 15 | |||
| 16 | **Address List** | ||
| 17 | |||
| 18 | |=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note** | ||
| 19 | |(% colspan="1" rowspan="4" %)Bit|R|RDDDDD.dd|0~~59915.15|Relay | ||
| 20 | |CR|CRDDDDD.dd|0~~3915.15|Control Relay | ||
| 21 | |MR|MRDDDDD.dd|0~~99915.15|Internal Auxiliary Relay | ||
| 22 | |LR|LRDDDDD.dd|0~~99915.15|Latch Relay | ||
| 23 | |(% colspan="1" rowspan="15" %)Word|DM|DMDDDDD|0~~65534|Data Memory | ||
| 24 | |CM|CMDDDDD|0~~11998|Control Memory | ||
| 25 | |TM|TMDDD|0~~511|Temporary Data Memory | ||
| 26 | |EM|EMDDDDD|0~~65534|Extension Data Memory | ||
| 27 | |FM|FMDDDDD|0~~32766|Extension Data Memory | ||
| 28 | |Z|ZDD|1~~12|Index Register | ||
| 29 | |VB|VBHHH|0~~F9F|Work Relay | ||
| 30 | |ZF|ZFDDDDD|0~~524287|File Register Serial Number System | ||
| 31 | |VM|VMDDDDD|0~~65535|Work Memory | ||
| 32 | |W|WHHHH|0~~7FFF|Link Register | ||
| 33 | |B|BHHH|0~~7FF|Link Relay | ||
| 34 | |R|RDDD|0~~999|Input Relay/Output Relay/Internal Auxiliary Relay | ||
| 35 | |CR|CRDDD|0~~999|Control Relay | ||
| 36 | |LR|LRDDD|0~~999|Latch Relay | ||
| 37 | |MR|MRDDDD|0~~3999|Internal Auxiliary Relay | ||
| 38 | |(% colspan="1" rowspan="9" %)Double Word|T|TDDDD|0~~9999|Timer | ||
| 39 | |C|CDDDD|0~~9999|Counter | ||
| 40 | |CTH|CTHD|0~~3|High-speed Counter Comparator(Current Value) | ||
| 41 | |CTC|CTCD|0~~7|High-speed Counter Comparator(Setting Value) | ||
| 42 | |TRM|TRMD|0~~7|Digital Trimmer | ||
| 43 | |C_Preset|C_PresetDDDD|0~~9999|Counter(Setting Value) | ||
| 44 | |C_Curr|C_CurrDDDD|0~~9999|Counter(Current Value) | ||
| 45 | |T_Preset|T_PresetDDDD|0~~9999|Timer(Setting Value) | ||
| 46 | |T_Curr|T_CurrDDDD|0~~9999|Timer(Current Value) | ||
| 47 | |||
| 48 | **PLC Settings** | ||
| 49 | |||
| 50 | Create the project according to the PLC specific model. | ||
| 51 | |||
| 52 | (% style="text-align:center" %) | ||
| 53 | [[image:KVsetup01.png]] | ||
| 54 | |||
| 55 | Enter the EtherNet/IP setting configuration window to check the PLC IP settings | ||
| 56 | |||
| 57 | (% style="text-align:center" %) | ||
| 58 | [[image:KVstep02.png]] | ||
| 59 | |||
| 60 | Double click the PLC unit icon on the main interface, then the settings would pop up on the right side. | ||
| 61 | |||
| 62 | (% style="text-align:center" %) | ||
| 63 | [[image:KVSetup03.png]] | ||
| 64 | |||
| 65 | So right now the PLC IP is 192.168.40.120 | ||
| 66 | |||
| 67 | {{info}} | ||
| 68 | ✎Note: PLC uses port 8500 to communicate with the PC, and uses port 8501 to communicate with the HMI. | ||
| 69 | {{/info}} | ||
| 70 | |||
| 71 | (% style="text-align:center" %) | ||
| 72 | [[image:KVSetup04.png]] | ||
| 73 | |||
| 74 | Programming the PLC project | ||
| 75 | |||
| 76 | (% style="text-align:center" %) | ||
| 77 | [[image:PrgramKVStudio.png]] | ||
| 78 | |||
| 79 | Connect with PLC through known IP address. | ||
| 80 | |||
| 81 | (% style="text-align:center" %) | ||
| 82 | [[image:KVSetup05.png]] | ||
| 83 | |||
| 84 | Download the program into PLC | ||
| 85 | |||
| 86 | (% style="text-align:center" %) | ||
| 87 | [[image:KVSetup06.png]] | ||
| 88 | |||
| 89 | If shows like below, which means download is success | ||
| 90 | |||
| 91 | (% style="text-align:center" %) | ||
| 92 | [[image:KVSetup07.png]] | ||
| 93 | |||
| 94 | **Cable Wiring** | ||
| 95 | |||