Changes for page Mitsubishi
Last modified by Joe on 2024/05/21 10:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,0 +1,558 @@ 1 += {{id name="HMitsubishi"/}}**Mitsubishi ** = 2 + 3 +== {{id name="HFX1SFF0C1NFF0C2NSerial"/}}**FX1S,1N,2N Serial ** == 4 + 5 +Supported Series: Mitsubishi FX1S, FX1N, FX2N series 6 + 7 +**1)V-BOX Settings** 8 + 9 +|**Item**|**Settings**|**Note** 10 +|Protocol|Mitsubishi FX1S/FX1N/FX2N| 11 +|Connection|RS422/RS485/RS232| 12 +|Baud rate|9600~~115200| 13 +|Data bit|7/8| 14 +|Parity|EVEN/Odd/None| 15 +|Stop bit|1/2| 16 +|PLC station No.|1~~255| 17 + 18 +**2)Address List** 19 + 20 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 21 +|(% rowspan="7" %)Bit|X|X|Xo|0~~303237| 22 +|Y|Y|Y o|0~~303237| 23 +|M|M|M d|0~~99999| 24 +|T|T|T d|0~~99999| 25 +|C|C|C d|0~~99999| 26 +|S|S|S d|0~~99999| 27 +|SM|SM|SM d|8000~~9999| 28 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237| 29 +|Y|Y|Y o|0~~303237| 30 +|M|M|M d|0~~99999| 31 +|T|T|T d|0~~99999| 32 +|C|C|C d|0~~199| 33 +|D|D|D d|0~~7999| 34 +|S|S|S d|0~~99999| 35 +|SD|SD|SD d|8000~~9999| 36 + 37 +**3)Configure the communication protocol** 38 + 39 +{{id name="Iimage-20220825102844-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dc262f14b14cf564.png||alt="image-20220825102844-3.png" height="1011" width="1920"]] 40 + 41 +**4)Cable Wiring** 42 + 43 +* **RS422** 44 + 45 +{{id name="Iimage-20220825103350-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9294a40c62eb99be.png||alt="image-20220825103350-4.png" height="284" width="723"]] 46 + 47 +{{id name="Iimage-20220825100845-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_860bcf87f6ca7b98.png||alt="image-20220825100845-4.png" height="246" width="419"]] 48 + 49 +== {{id name="HFX3UFF0C3GFF0C3GASerial"/}}**FX3U,3G,3GA Serial ** == 50 + 51 +Supported Series: Mitsubishi FX3U, FX3G, FX3GA series 52 + 53 +**1)V-BOX Settings** 54 + 55 +|**Item**|**Settings**|**Note** 56 +|Protocol|Mitsubishi FX3U/3G/3GA| 57 +|Connection|RS422/RS485/RS232| 58 +|Baud rate|9600~~115200| 59 +|Data bit|7/8| 60 +|Parity|EVEN/Odd/None| 61 +|Stop bit|1/2| 62 +|PLC station No.|1~~255| 63 + 64 +**2)Address List** 65 + 66 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 67 +|(% rowspan="7" %)Bit|X|X|Xo|0~~303237| 68 +|Y|Y|Y o|0~~303237| 69 +|M|M|M d|0~~99999| 70 +|T|T|T d|0~~99999| 71 +|C|C|C d|0~~99999| 72 +|S|S|S d|0~~99999| 73 +|SM|SM|SM d|8000~~9999| 74 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237| 75 +|Y|Y|Y o|0~~303237| 76 +|M|M|M d|0~~99999| 77 +|T|T|T d|0~~99999| 78 +|C|C|C d|0~~199| 79 +|D|D|D d|0~~7999| 80 +|S|S|S d|0~~99999| 81 +|SD|SD|SD d|8000~~9999| 82 + 83 +**3)Configure the communication protocol** 84 + 85 +{{id name="Iimage-20220825102649-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_4d2a4921240d23c6.png||alt="image-20220825102649-2.png" height="1009" width="1920"]] 86 + 87 +**4)Cable Wiring** 88 + 89 +* **RS422** 90 + 91 +{{id name="Iimage-20220825103421-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e904556bb758dfe.png||alt="image-20220825103421-5.png" height="296" width="715"]] 92 + 93 +{{id name="Iimage-20220825100845-4.png-1"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_860bcf87f6ca7b98.png||alt="image-20220825100845-4.png" height="246" width="419"]] 94 + 95 +== {{id name="HFX3UEthernet"/}}**FX3U Ethernet ** == 96 + 97 +Supported Modules: FX3U-ENET-ADP, FX3U-ENET-L 98 + 99 +**1)V-BOX Settings** 100 + 101 +|Items|Settings|Note 102 +|Protocol|Mitsubishi FX3U| 103 +|Connection|Ethernet| 104 +|Port No.|5009|Must be the same as the PLC setting 105 +|PLC station No.|0| 106 + 107 +**2)Address List** 108 + 109 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 110 +|(% rowspan="7" %)Bit|X|X|X OOO|0~~377| 111 +|Y|Y|Y OOO|0~~377| 112 +|M|M|M DDDD|0~~7679| 113 +|SM|SM|SM DDDD|8000~~8511| 114 +|S|S|S DDDD|0~~4095| 115 +|TS|TS|TS DDD|0~~511| 116 +|CS|CS|CS DDD|0~~255| 117 +|(% rowspan="5" %)Word|CN|CN|CN DDD|0~~199| 118 +|TN|TN|TN DDD|0~~511| 119 +|D|D|D DDDD|0~~7999| 120 +|SD|SD|SD DDDD|8000~~8511| 121 +|R|R|R DDDDD|0~~32767| 122 + 123 +**3)Ethernet Module Settings** 124 + 125 +FX3U-ENET-L module configuration 126 + Set up the FX3U-ENET-L Ethernet module settings as follows. 127 + Select the module location, which in this document is Module 0. 128 + 129 +{{id name="Iimage-20221116105850-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_949d5d77c1d9cf1e.png||alt="image-20221116105850-1.png" height="573" width="706"]] 130 + 131 +Select "Operational setting" to enter the following screen. 132 + 133 +The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default. 134 + 135 +{{id name="Iimage-20221116105947-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dfbfdd586c855c47.png||alt="image-20221116105947-1.png" height="573" width="706"]] 136 + 137 +Select "Open setting" to enter the setting interface, the settings are as follows. 138 + 139 +The third item "Protocol" selects TCP, and "Open system" selects MELSOFT connection, which allows the 140 + 141 +Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module. 142 + 143 +{{id name="Iimage-20221116110802-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7c01ac15090fcc5b.png||alt="image-20221116110802-1.png" height="549" width="706"]] 144 + 145 +Click on "transter setup" - "PC side I/F setting", see the following figure. 146 + 147 +After setting, the first download must use the programming cable, as shown in the figure; after that, can 148 + 149 +use the IP set in the "Ethernet board" to communicate directly with the network cable. 150 + 151 +{{id name="Iimage-20221116110832-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d6fd9ce3b96f99e2.png||alt="image-20221116110832-2.png" height="423" width="708"]] 152 + 153 +Read and write data from the Ethernet module 154 + 155 +{{id name="Iimage-20221116110907-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_690b3e57b29cfd4b.png||alt="image-20221116110907-3.png" height="549" width="706"]] 156 + 157 +Set "Transter setup" to COM communication, and read or write operation as shown below 158 + 159 +{{id name="Iimage-20221116110917-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b317253742f7151.png||alt="image-20221116110917-4.png" height="549" width="706"]] 160 + 161 +**4)PLC Settings (GX Works 2)** 162 + 163 +Create a blank FX5U project 164 + 165 +Find Current Connection in the navigation 166 + 167 +{{id name="Iimage-20221116111427-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d2a46ba9c005cf38.png||alt="image-20221116111427-1.png" height="421" width="705"]] 168 + 169 +Select Connection Channel List 170 + 171 +Select Ethernet board communication 172 + 173 +{{id name="Iimage-20221116111451-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8f49721a3e5b0ef9.png||alt="image-20221116111451-2.png" height="421" width="705"]] 174 + 175 +Select Ethernet Module 176 + Set the IP address of the PLC 177 + 178 +{{id name="Iimage-20221116111509-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e9a9e29a46a1041.png||alt="image-20221116111509-3.png" height="666" width="699"]] 179 + 180 +Read or write PLC data, in this document is read 181 + 182 +{{id name="Iimage-20221116111651-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_e3d629103727a423.png||alt="image-20221116111651-4.png" height="416" width="697"]] 183 + 184 +{{id name="Iimage-20221116111727-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7f29923ebcb670d1.png||alt="image-20221116111727-5.png" height="416" width="697"]] 185 + 186 +**4)Configure the communication protocol** 187 + 188 +{{id name="Iimage-20221119101946-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b2cdc33b6eb92b67.png||alt="image-20221119101946-2.png" height="395" width="695"]] 189 + 190 +== {{id name="HFX5USerial"/}}**FX5U Serial ** == 191 + 192 +Mitsubishi FX5U series PLC 193 + 194 +**1)V-BOX Settings** 195 + 196 +|**Item**|**Settings**|**Note** 197 +|Protocol|Mitsubishi FX5U| 198 +|Connection|RS422/RS485| 199 +|Baud rate|9600| 200 +|Data bit|7| 201 +|Parity|Odd| 202 +|Stop bit|1| 203 +|PLC station No.|1~~255|Need to be the same as PLC settings 204 + 205 +**2)Address List** 206 + 207 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 208 +|(% rowspan="15" %)Bit|X|X|X o|0~~303237| 209 +|Y|Y|Y o|0~~303237| 210 +|M|M|M d|0~~99999| 211 +|B|B|B h|0~~7FFF| 212 +|F|F|F d|0~~32767| 213 +|SB|SB|SB h|0~~7FFF| 214 +|TS|TS|TS d|0~~1023| 215 +|TC|TC|TC d|0~~1023| 216 +|STS|STS|STS d|0~~1023| 217 +|STC|STC|STS d|0~~1023| 218 +|CS|CS|CS d|0~~1023| 219 +|CC|CC|CC d|0~~1023| 220 +|SM|SM|SM d|0~~9999| 221 +|L|L|L d|0~~32767| 222 +|S|S|S d|0~~4095| 223 +|(% rowspan="9" %)Word|W|W|W h|0~~3FF| 224 +|TN|TN|TN d|0~~1023| 225 +|STN|STN|STN d|0~~1023| 226 +|CN|CN|CN d|0~~1023| 227 +|R|R|R d|0~~32767| 228 +|SW|SW|SW h|0~~7FFF| 229 +|Z|Z|Z d|0~~23| 230 +|D|D|D d|0~~7999| 231 +|SD|SD|SD d|0~~11999| 232 + 233 +**3)PLC Settings (GX Works 3)** 234 + 235 +Create a blank FX5U project 236 + 237 +Find the 485 serial port module in the system navigation bar and double click to enter the settings. 238 + 239 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_5c9cb13fac1e6c93.png3Fwidth3D20026height3D46226rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5c9cb13fac1e6c93.png?width=200&height=462&rev=1.1||alt="12.PLC Protocol_html_5c9cb13fac1e6c93.png" height="462" width="200"]] 240 + 241 +Select protocol in the setting item, and set parameters. 242 + 243 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_de942589ca070228.png3Fwidth3D60026height3D32426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_de942589ca070228.png?width=600&height=324&rev=1.1||alt="12.PLC Protocol_html_de942589ca070228.png" height="324" width="600"]] 244 + 245 +Set station number, and [Message Pattern] (Pattern 1 or Pattern 4) 246 + 247 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_387ec7d00b5feb59.png3Fwidth3D60026height3D32326rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_387ec7d00b5feb59.png?width=600&height=323&rev=1.1||alt="12.PLC Protocol_html_387ec7d00b5feb59.png" height="323" width="600"]] 248 + 249 +Click the [Apply] button to finish the setting. 250 + 251 +Click download and select the items as below, then click [execute] to download the configuration to PLC. 252 + 253 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_cdef1c5ec8cc2105.png3Fwidth3D60026height3D43426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_cdef1c5ec8cc2105.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_cdef1c5ec8cc2105.png" height="434" width="600"]] 254 + 255 + As soon as download is completed, connect PLC with serial port, then configure it in the [Specify Connection Destination Connection]. 256 + 257 +Done. 258 + 259 +**4)Configure the communication protocol** 260 + 261 +{{id name="Iimage-20220825104904-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dbaddd53e9951a17.png||alt="image-20220825104904-1.png" height="1033" width="1920"]] 262 + 263 +**5)Cable Wiring** 264 + 265 +* **RS422** 266 + 267 +{{id name="Iimage-20220825105105-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d022c5ff4cf8c68e.png||alt="image-20220825105105-2.png" height="288" width="711"]] 268 + 269 +{{id name="Iimage-20220825105533-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50e173394c73f154.png||alt="image-20220825105533-3.png" height="246" width="420"]] 270 + 271 +== {{id name="HFX5UEthernet"/}}**FX5U Ethernet ** == 272 + 273 +Mitsubishi FX5U series PLC 274 + 275 +**1)V-BOX Settings** 276 + 277 +|**Items**|**Settings**|**Note** 278 +|Protocol|Mitsubishi FX5U| 279 +|Connection|Ethernet| 280 +|Port No.|5002|Must be the same as the PLC setting 281 +|PLC station No.|0| 282 + 283 +**2)Address List** 284 + 285 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 286 +|(% rowspan="15" %)Bit|X|X|X o|0~~303237| 287 +|Y|Y|Y o|0~~303237| 288 +|M|M|M d|0~~99999| 289 +|B|B|B h|0~~7FFF| 290 +|F|F|F d|0~~32767| 291 +|SB|SB|SB h|0~~7FFF| 292 +|TS|TS|TS d|0~~1023| 293 +|TC|TC|TC d|0~~1023| 294 +|STS|STS|STS d|0~~1023| 295 +|STC|STC|STS d|0~~1023| 296 +|CS|CS|CS d|0~~1023| 297 +|CC|CC|CC d|0~~1023| 298 +|SM|SM|SM d|0~~9999| 299 +|L|L|L d|0~~32767| 300 +|S|S|S d|0~~4095| 301 +|(% rowspan="9" %)Word|W|W|W h|0~~3FF| 302 +|TN|TN|TN d|0~~1023| 303 +|STN|STN|STN d|0~~1023| 304 +|CN|CN|CN d|0~~1023| 305 +|R|R|R d|0~~32767| 306 +|SW|SW|SW h|0~~7FFF| 307 +|Z|Z|Z d|0~~23| 308 +|D|D|D d|0~~7999| 309 +|SD|SD|SD d|0~~11999| 310 + 311 +**3)PLC Settings (GX Works 3)** 312 + 313 +Find the [Ethernet port] in the navigation area. 314 + 315 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_8e8f85ace087346c.png3Fwidth3D30026height3D59326rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8e8f85ace087346c.png?width=300&height=593&rev=1.1||alt="12.PLC Protocol_html_8e8f85ace087346c.png" height="593" width="300"]] 316 + 317 +Select [Own Node Settings] in the [Setting Item List]; 318 + 319 +Set [IP Address], [Subnet Mask], [Default Gateway]; 320 + 321 +Click [Detailed Settings] into [Ethernet Configuration (Built-in Ethernet Port)] windows; 322 + 323 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_5d98495052c8c10e.png3Fwidth3D60026height3D33926rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5d98495052c8c10e.png?width=600&height=339&rev=1.1||alt="12.PLC Protocol_html_5d98495052c8c10e.png" height="339" width="600"]] 324 + 325 +Select [SLMP Connection Module] and add into host station as below picture shows; 326 + 327 +Set Port number as 5002 (this is necessary settings); 328 + 329 +Click [Close with Reflecting the Setting] to save and close window; 330 + 331 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_14b489fdc6c6589d.png3Fwidth3D60026height3D35026rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_14b489fdc6c6589d.png?width=600&height=350&rev=1.1||alt="12.PLC Protocol_html_14b489fdc6c6589d.png" height="350" width="600"]] 332 + 333 +Click [Apply] to completed Etherenet settings; 334 + 335 +Switch to the [On line data operation] interface as below, check the item and click [Execute] to download. 336 + 337 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_c93025a968a8a9e7.png3Fwidth3D60026height3D43426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_c93025a968a8a9e7.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_c93025a968a8a9e7.png" height="434" width="600"]] 338 + 339 +**4)Configure the communication protocol** 340 + 341 +{{id name="Iimage-20220825112403-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_caa9bf4d8cc6de0f.png||alt="图片-20220825112403-1.png" height="1033" width="1920"]] 342 + 343 +**5)Cable Wiring** 344 + 345 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 346 + 347 +== {{id name="HL02Serial"/}}**L02 Serial ** == 348 + 349 +Mitsubishi L02 series CPU built-in serial port. 350 + 351 +**1)V-BOX Settings** 352 + 353 +|**Item**|**Settings**|**Note** 354 +|Protocol|Mitsubishi L02| 355 +|Connection|RS422| 356 +|Baud rate|115200| 357 +|Data bit|8| 358 +|Parity|Odd| 359 +|Stop bit|1| 360 +|PLC station No.|1~~255|Need to be the same as PLC settings 361 + 362 +**2)Address List** 363 + 364 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 365 +|Bit|X|X|X h|0~~FFFF| 366 +|Bit|Y|Y|Y h|0~~FFFF| 367 +|Bit|M|M|M d|0~~9999| 368 +|Bit|L|L|L d|0~~9999| 369 +|Bit|F|F|F d|0~~9999| 370 +|Bit|B|B|B h|0~~FFFF| 371 +|Bit|V|V|V d|0~~2047| 372 +|Bit|TC|TC|TC d|0~~9999| 373 +|Bit|SS|SS|SS d|0~~9999| 374 +|Bit|SC|SC|SC d|0~~9999| 375 +|Bit|CS|CS|CS d|0~~9999| 376 +|Bit|CC|CC|CC d|0~~9999| 377 +|Bit|SB|SB|SB h|0~~FFFF| 378 +|Bit|SM|SM|SM d|0~~2047| 379 +|Bit|STS|STS|STS d|0~~1023| 380 +|Bit|S|S|S d|0~~9999| 381 +|Bit|DX|DX|DX h|0~~FFFF| 382 +|Bit|DY|DY|DY h|0~~FFFF| 383 +|Bit|TS|TS|TS d|0~~9999| 384 +|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15| 385 +|Word|W|W|W h|0~~FFFF| 386 +|Word|TN|TN|TN d|0~~99999| 387 +|Word|SN|SN|SN d|0~~99999| 388 +|Word|CN|CN|CN d|0~~99999| 389 +|Word|R|R|R d|0~~99999| 390 +|Word|SW|SW|SW h|0~~FFFF| 391 +|Word|Z|Z|Z d|0~~99999| 392 +|Word|ZR|ZR|ZR h|0~~FFFF| 393 +|Word|D|D|D d|0~~99999| 394 + 395 +**3)Communication Settings** 396 + 397 +{{id name="Iimage-20220825160648-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_cfed67f2ecb4ccec.png||alt="image-20220825160648-3.png" height="1009" width="1920"]] 398 + 399 +**4)Cable Wiring** 400 + 401 +* **RS422** 402 + 403 +{{id name="Iimage-20220825161612-8.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_90e38f152d639809.png||alt="image-20220825161612-8.png" height="278" width="612"]] 404 + 405 +{{id name="Iimage-20220825160820-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d301e675d8224725.png||alt="image-20220825160820-4.png" height="208" width="359"]] 406 + 407 +== {{id name="HL02Ethernet"/}}**L02 Ethernet ** == 408 + 409 +Mitsubishi L series CPU built-in Ethernet port. 410 + 411 +**1)V-BOX Settings** 412 + 413 +|**Items**|**Settings**|**Note** 414 +|Protocol|MIT L02 CPU MELSEC| 415 +|Connection|Ethernet| 416 +|Port No.|1025|Must be the same as the PLC setting 417 +|PLC station No.|0|Must be the same as the PLC setting 418 + 419 +**2)Address List** 420 + 421 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 422 +|Bit|X|X|X h|0~~FFFF| 423 +|Bit|Y|Y|Y h|0~~FFFF| 424 +|Bit|M|M|M d|0~~9999| 425 +|Bit|L|L|L d|0~~9999| 426 +|Bit|F|F|F d|0~~9999| 427 +|Bit|B|B|B h|0~~FFFF| 428 +|Bit|V|V|V d|0~~2047| 429 +|Bit|TC|TC|TC d|0~~9999| 430 +|Bit|SS|SS|SS d|0~~9999| 431 +|Bit|SC|SC|SC d|0~~9999| 432 +|Bit|CS|CS|CS d|0~~9999| 433 +|Bit|CC|CC|CC d|0~~9999| 434 +|Bit|SB|SB|SB h|0~~FFFF| 435 +|Bit|SM|SM|SM d|0~~2047| 436 +|Bit|STS|STS|STS d|0~~1023| 437 +|Bit|S|S|S d|0~~9999| 438 +|Bit|DX|DX|DX h|0~~FFFF| 439 +|Bit|DY|DY|DY h|0~~FFFF| 440 +|Bit|TS|TS|TS d|0~~9999| 441 +|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15| 442 +|Word|W|W|W h|0~~FFFF| 443 +|Word|TN|TN|TN d|0~~99999| 444 +|Word|SN|SN|SN d|0~~99999| 445 +|Word|CN|CN|CN d|0~~99999| 446 +|Word|R|R|R d|0~~99999| 447 +|Word|SW|SW|SW h|0~~FFFF| 448 +|Word|Z|Z|Z d|0~~99999| 449 +|Word|ZR|ZR|ZR h|0~~FFFF| 450 +|Word|D|D|D d|0~~99999| 451 + 452 +**3)PLC Settings (GX Works2 )** 453 + 454 +Create a project 455 + 456 +Set PLC IP, subnet mask and gateway; 457 + 458 +Select [Binary Code] as communication data code; 459 + 460 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_776e17505f3fc6c0.png3Fwidth3D60026height3D52426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_776e17505f3fc6c0.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_776e17505f3fc6c0.png" height="524" width="600"]] 461 + 462 +Set PLC port number, for example 1025 463 + 464 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_8d0d1a22d388f70b.png3Fwidth3D60026height3D52426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8d0d1a22d388f70b.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]] 465 + 466 +Save settings; 467 + 468 +Download project into PLC device; 469 + 470 +Restart PLC device; 471 + 472 +**4)Configure the communication protocol** 473 + 474 +{{id name="Iimage-20220825142659-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_fafc9b29e20178c0.png||alt="image-20220825142659-1.png" height="1010" width="1920"]] 475 + 476 +**5)Cable Wiring** 477 + 478 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1-1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 479 + 480 +== {{id name="HQ12HSerial"/}}**Q12H Serial ** == 481 + 482 +This Demo shows V-BOX communicate with Q12H PLC by Q02H serial Protocol 483 + 484 +**[[Download link>>url:https://ftp.we-con.com.cn/Download/WIKI/PI%20HMI/Demo/Communication/V-Box%20connect%20PLC%20Q12H.rar]]** 485 + 486 +== {{id name="HQJ71E71Ethernet"/}}**QJ71E71 Ethernet ** == 487 + 488 +Mitsubishi QJ71E71 Ethernet communication module; 489 + 490 +**1)V-BOX Settings** 491 + 492 +|**Items**|**Settings**|**Note** 493 +|Protocol|MIT QJ71E71 MELSEC| 494 +|Connection|Ethernet| 495 +|Port No.|1025|Must be the same as the PLC setting 496 +|PLC station No.|0|Must be the same as the PLC setting 497 + 498 +**2)Address List** 499 + 500 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 501 +|(% rowspan="18" %)Bit|X|X|X h|0~~1FFF| 502 +|Y|Y|Y h|0~~1FFF| 503 +|M|M|M d|0~~99999| 504 +|L|L|L d|0~~8191| 505 +|F|F|F d|0~~2047| 506 +|B|B|B h|0~~1FFF| 507 +|V|V|V d|0~~2047| 508 +|TS|TS|TS d|0~~2047| 509 +|TC|TC|TC d|0~~2047| 510 +|SS|SS|SS d|0~~2047| 511 +|SC|SC|SC d|0~~2047| 512 +|CS|CS|CS d|0~~1023| 513 +|CC|CC|CC d|0~~1023| 514 +|SB|SB|SB h|0~~7FF| 515 +|S|S|S d|0~~8191| 516 +|DX|DX|DX h|0~~1FFF| 517 +|DY|DY|DY h|0~~1FFF| 518 +|SM|SM|SM d|8000~~9999| 519 +|(% rowspan="10" %)Word|SD|SD|SD d|0~~2047| 520 +|D|D|D d|0~~12287| 521 +|W|W|W h|0~~1FFF| 522 +|TN|TN|TN d|0~~2047| 523 +|SN|SN|SN d|0~~2047| 524 +|CN|CN|CN d|0~~1023| 525 +|R|R|R d|0~~32767| 526 +|SW|SW|SW h|0~~7FF| 527 +|Z|Z|Z d|0~~15| 528 +|ZR|ZR|ZR h|0~~FE7FF| 529 + 530 +**3)PLC Settings(GX Works2)** 531 + 532 +* Click [Ethernet/CC IE/MELSECNET]; 533 +* Please select [Ethernet] as network type; 534 +* Set station I/O number according to situation (For example, 0020 means that the module is connected to PLC CPU in first order); 535 +* Select [Online] as Mode; 536 +* {{id name="Iimage-20221119171343-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png||alt="image-20221119171343-2.png" height="341" width="587"]] 537 +* Click [Operation setting] to set IP; 538 +* Select [Binary Code] as [Communication Data Code]; 539 +* {{id name="Iimage-20221119171436-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png||alt="image-20221119171436-3.png" height="354" width="588"]] 540 +* Click [Open setting] 541 +* Set protocol: TCP; 542 +* Set [unpassive] in [Open system]; 543 +* Set [receive] in [Fixed buffer]; 544 +* Set [procedure Exist] in [Fixed buffer communication]; 545 +* Disable [Pairing open]; 546 +* Set [No confirm] in [Existence confirmation]; 547 +* Host station port number: 5009; 548 +* Save settings; 549 +* {{id name="Iimage-20221119171611-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1d8e2f4fb7c72471.png||alt="image-20221119171611-4.png" height="354" width="588"]] 550 +* Download project into PLC and restart it 551 + 552 +**4)Configure the communication protocol** 553 + 554 +{{id name="Iimage-20221119171832-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50990385ef491b9e.png||alt="image-20221119171832-5.png" height="354" width="625"]] 555 + 556 +**5)Cable Wiring** 557 + 558 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1-2"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="38" width="76"]]