1 +== **FX1S,1N,2N Serial ** ==
2 +
3 +Supported Series: Mitsubishi FX1S, FX1N, FX2N series
4 +
5 +**V-BOX Settings**
6 +
7 +|**Item**|**Settings**|**Note**
8 +|Protocol|Mitsubishi FX1S/FX1N/FX2N|
9 +|Connection|RS422/RS485/RS232|
10 +|Baud rate|9600~~115200|
11 +|Data bit|7/8|
12 +|Parity|EVEN/Odd/None|
13 +|Stop bit|1/2|
14 +|PLC station No.|1~~255|
15 +
16 +**Address List**
17 +
18 +|**Type**|**Device registers**|**V-Box registers**|**Format**|**Range**|**Note**
19 +|(% rowspan="7" %)Bit|X|X|Xo|0~~303237|
20 +|Y|Y|Y o|0~~303237|
21 +|M|M|M d|0~~99999|
22 +|T|T|T d|0~~99999|
23 +|C|C|C d|0~~99999|
24 +|S|S|S d|0~~99999|
25 +|SM|SM|SM d|8000~~9999|
26 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237|
27 +|Y|Y|Y o|0~~303237|
28 +|M|M|M d|0~~99999|
29 +|T|T|T d|0~~99999|
30 +|C|C|C d|0~~199|
31 +|D|D|D d|0~~7999|
32 +|S|S|S d|0~~99999|
33 +|SD|SD|SD d|8000~~9999|
34 +
35 +**Configure the communication protocol**
36 +
37 +{{id name="Iimage-20220825102844-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dc262f14b14cf564.png||alt="image-20220825102844-3.png" height="1011" width="1920"]]
38 +
39 +**Cable Wiring**
40 +
41 +**RS422**
42 +
43 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9294a40c62eb99be.png||alt="image-20220825103350-4.png" height="284" width="723"]]
44 +
45 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_860bcf87f6ca7b98.png||alt="image-20220825100845-4.png" height="246" width="419"]]
46 +
47 +== **FX3U,3G,3GA Serial ** ==
48 +
49 +Supported Series: Mitsubishi FX3U, FX3G, FX3GA series
50 +
51 +**V-BOX Settings**
52 +
53 +|**Item**|**Settings**|**Note**
54 +|Protocol|Mitsubishi FX3U/3G/3GA|
55 +|Connection|RS422/RS485/RS232|
56 +|Baud rate|9600~~115200|
57 +|Data bit|7/8|
58 +|Parity|EVEN/Odd/None|
59 +|Stop bit|1/2|
60 +|PLC station No.|1~~255|
61 +
62 +**Address List**
63 +
64 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
65 +|(% rowspan="7" %)Bit|X|X|Xo|0~~303237|
66 +|Y|Y|Y o|0~~303237|
67 +|M|M|M d|0~~99999|
68 +|T|T|T d|0~~99999|
69 +|C|C|C d|0~~99999|
70 +|S|S|S d|0~~99999|
71 +|SM|SM|SM d|8000~~9999|
72 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237|
73 +|Y|Y|Y o|0~~303237|
74 +|M|M|M d|0~~99999|
75 +|T|T|T d|0~~99999|
76 +|C|C|C d|0~~199|
77 +|D|D|D d|0~~7999|
78 +|S|S|S d|0~~99999|
79 +|SD|SD|SD d|8000~~9999|
80 +
81 +**Configure the communication protocol**
82 +
83 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_4d2a4921240d23c6.png||alt="image-20220825102649-2.png" height="1009" width="1920"]]
84 +
85 +**4)Cable Wiring**
86 +
87 +**RS422**
88 +
89 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e904556bb758dfe.png||alt="image-20220825103421-5.png" height="296" width="715"]]
90 +
91 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_860bcf87f6ca7b98.png||alt="image-20220825100845-4.png" height="246" width="419"]]
92 +
93 +== {{id name="HFX3UEthernet"/}}**FX3U Ethernet ** ==
94 +
95 +Supported Modules: FX3U-ENET-ADP, FX3U-ENET-L
96 +
97 +**1)V-BOX Settings**
98 +
99 +|Items|Settings|Note
100 +|Protocol|Mitsubishi FX3U|
101 +|Connection|Ethernet|
102 +|Port No.|5009|Must be the same as the PLC setting
103 +|PLC station No.|0|
104 +
105 +**2)Address List**
106 +
107 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
108 +|(% rowspan="7" %)Bit|X|X|X OOO|0~~377|
109 +|Y|Y|Y OOO|0~~377|
110 +|M|M|M DDDD|0~~7679|
111 +|SM|SM|SM DDDD|8000~~8511|
112 +|S|S|S DDDD|0~~4095|
113 +|TS|TS|TS DDD|0~~511|
114 +|CS|CS|CS DDD|0~~255|
115 +|(% rowspan="5" %)Word|CN|CN|CN DDD|0~~199|
116 +|TN|TN|TN DDD|0~~511|
117 +|D|D|D DDDD|0~~7999|
118 +|SD|SD|SD DDDD|8000~~8511|
119 +|R|R|R DDDDD|0~~32767|
120 +
121 +**3)Ethernet Module Settings**
122 +
123 +FX3U-ENET-L module configuration
124 + Set up the FX3U-ENET-L Ethernet module settings as follows.
125 + Select the module location, which in this document is Module 0.
126 +
127 +{{id name="Iimage-20221116105850-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_949d5d77c1d9cf1e.png||alt="image-20221116105850-1.png" height="573" width="706"]]
128 +
129 +Select "Operational setting" to enter the following screen.
130 +
131 +The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default.
132 +
133 +{{id name="Iimage-20221116105947-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dfbfdd586c855c47.png||alt="image-20221116105947-1.png" height="573" width="706"]]
134 +
135 +Select "Open setting" to enter the setting interface, the settings are as follows.
136 +
137 +The third item "Protocol" selects TCP, and "Open system" selects MELSOFT connection, which allows the
138 +
139 +Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module.
140 +
141 +{{id name="Iimage-20221116110802-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7c01ac15090fcc5b.png||alt="image-20221116110802-1.png" height="549" width="706"]]
142 +
143 +Click on "transter setup" - "PC side I/F setting", see the following figure.
144 +
145 +After setting, the first download must use the programming cable, as shown in the figure; after that, can
146 +
147 +use the IP set in the "Ethernet board" to communicate directly with the network cable.
148 +
149 +{{id name="Iimage-20221116110832-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d6fd9ce3b96f99e2.png||alt="image-20221116110832-2.png" height="423" width="708"]]
150 +
151 +Read and write data from the Ethernet module
152 +
153 +{{id name="Iimage-20221116110907-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_690b3e57b29cfd4b.png||alt="image-20221116110907-3.png" height="549" width="706"]]
154 +
155 +Set "Transter setup" to COM communication, and read or write operation as shown below
156 +
157 +{{id name="Iimage-20221116110917-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b317253742f7151.png||alt="image-20221116110917-4.png" height="549" width="706"]]
158 +
159 +**4)PLC Settings (GX Works 2)**
160 +
161 +Create a blank FX5U project
162 +
163 +Find Current Connection in the navigation
164 +
165 +{{id name="Iimage-20221116111427-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d2a46ba9c005cf38.png||alt="image-20221116111427-1.png" height="421" width="705"]]
166 +
167 +Select Connection Channel List
168 +
169 +Select Ethernet board communication
170 +
171 +{{id name="Iimage-20221116111451-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8f49721a3e5b0ef9.png||alt="image-20221116111451-2.png" height="421" width="705"]]
172 +
173 +Select Ethernet Module
174 + Set the IP address of the PLC
175 +
176 +{{id name="Iimage-20221116111509-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e9a9e29a46a1041.png||alt="image-20221116111509-3.png" height="666" width="699"]]
177 +
178 +Read or write PLC data, in this document is read
179 +
180 +{{id name="Iimage-20221116111651-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_e3d629103727a423.png||alt="image-20221116111651-4.png" height="416" width="697"]]
181 +
182 +{{id name="Iimage-20221116111727-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7f29923ebcb670d1.png||alt="image-20221116111727-5.png" height="416" width="697"]]
183 +
184 +**4)Configure the communication protocol**
185 +
186 +{{id name="Iimage-20221119101946-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b2cdc33b6eb92b67.png||alt="image-20221119101946-2.png" height="395" width="695"]]
187 +
188 +== {{id name="HFX5USerial"/}}**FX5U Serial ** ==
189 +
190 +Mitsubishi FX5U series PLC
191 +
192 +**1)V-BOX Settings**
193 +
194 +|**Item**|**Settings**|**Note**
195 +|Protocol|Mitsubishi FX5U|
196 +|Connection|RS422/RS485|
197 +|Baud rate|9600|
198 +|Data bit|7|
199 +|Parity|Odd|
200 +|Stop bit|1|
201 +|PLC station No.|1~~255|Need to be the same as PLC settings
202 +
203 +**2)Address List**
204 +
205 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
206 +|(% rowspan="15" %)Bit|X|X|X o|0~~303237|
207 +|Y|Y|Y o|0~~303237|
208 +|M|M|M d|0~~99999|
209 +|B|B|B h|0~~7FFF|
210 +|F|F|F d|0~~32767|
211 +|SB|SB|SB h|0~~7FFF|
212 +|TS|TS|TS d|0~~1023|
213 +|TC|TC|TC d|0~~1023|
214 +|STS|STS|STS d|0~~1023|
215 +|STC|STC|STS d|0~~1023|
216 +|CS|CS|CS d|0~~1023|
217 +|CC|CC|CC d|0~~1023|
218 +|SM|SM|SM d|0~~9999|
219 +|L|L|L d|0~~32767|
220 +|S|S|S d|0~~4095|
221 +|(% rowspan="9" %)Word|W|W|W h|0~~3FF|
222 +|TN|TN|TN d|0~~1023|
223 +|STN|STN|STN d|0~~1023|
224 +|CN|CN|CN d|0~~1023|
225 +|R|R|R d|0~~32767|
226 +|SW|SW|SW h|0~~7FFF|
227 +|Z|Z|Z d|0~~23|
228 +|D|D|D d|0~~7999|
229 +|SD|SD|SD d|0~~11999|
230 +
231 +**3)PLC Settings (GX Works 3)**
232 +
233 +Create a blank FX5U project
234 +
235 +Find the 485 serial port module in the system navigation bar and double click to enter the settings.
236 +
237 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_5c9cb13fac1e6c93.png3Fwidth3D20026height3D46226rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5c9cb13fac1e6c93.png?width=200&height=462&rev=1.1||alt="12.PLC Protocol_html_5c9cb13fac1e6c93.png" height="462" width="200"]]
238 +
239 +Select protocol in the setting item, and set parameters.
240 +
241 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_de942589ca070228.png3Fwidth3D60026height3D32426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_de942589ca070228.png?width=600&height=324&rev=1.1||alt="12.PLC Protocol_html_de942589ca070228.png" height="324" width="600"]]
242 +
243 +Set station number, and [Message Pattern] (Pattern 1 or Pattern 4)
244 +
245 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_387ec7d00b5feb59.png3Fwidth3D60026height3D32326rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_387ec7d00b5feb59.png?width=600&height=323&rev=1.1||alt="12.PLC Protocol_html_387ec7d00b5feb59.png" height="323" width="600"]]
246 +
247 +Click the [Apply] button to finish the setting.
248 +
249 +Click download and select the items as below, then click [execute] to download the configuration to PLC.
250 +
251 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_cdef1c5ec8cc2105.png3Fwidth3D60026height3D43426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_cdef1c5ec8cc2105.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_cdef1c5ec8cc2105.png" height="434" width="600"]]
252 +
253 + As soon as download is completed, connect PLC with serial port, then configure it in the [Specify Connection Destination Connection].
254 +
255 +Done.
256 +
257 +**4)Configure the communication protocol**
258 +
259 +{{id name="Iimage-20220825104904-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dbaddd53e9951a17.png||alt="image-20220825104904-1.png" height="1033" width="1920"]]
260 +
261 +**5)Cable Wiring**
262 +
263 +* **RS422**
264 +
265 +{{id name="Iimage-20220825105105-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d022c5ff4cf8c68e.png||alt="image-20220825105105-2.png" height="288" width="711"]]
266 +
267 +{{id name="Iimage-20220825105533-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50e173394c73f154.png||alt="image-20220825105533-3.png" height="246" width="420"]]
268 +
269 +== **FX5U Ethernet ** ==
270 +
271 +Mitsubishi FX5U series PLC
272 +
273 +**1)V-BOX Settings**
274 +
275 +|**Items**|**Settings**|**Note**
276 +|Protocol|Mitsubishi FX5U|
277 +|Connection|Ethernet|
278 +|Port No.|5002|Must be the same as the PLC setting
279 +|PLC station No.|0|
280 +
281 +**2)Address List**
282 +
283 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
284 +|(% rowspan="15" %)Bit|X|X|X o|0~~303237|
285 +|Y|Y|Y o|0~~303237|
286 +|M|M|M d|0~~99999|
287 +|B|B|B h|0~~7FFF|
288 +|F|F|F d|0~~32767|
289 +|SB|SB|SB h|0~~7FFF|
290 +|TS|TS|TS d|0~~1023|
291 +|TC|TC|TC d|0~~1023|
292 +|STS|STS|STS d|0~~1023|
293 +|STC|STC|STS d|0~~1023|
294 +|CS|CS|CS d|0~~1023|
295 +|CC|CC|CC d|0~~1023|
296 +|SM|SM|SM d|0~~9999|
297 +|L|L|L d|0~~32767|
298 +|S|S|S d|0~~4095|
299 +|(% rowspan="9" %)Word|W|W|W h|0~~3FF|
300 +|TN|TN|TN d|0~~1023|
301 +|STN|STN|STN d|0~~1023|
302 +|CN|CN|CN d|0~~1023|
303 +|R|R|R d|0~~32767|
304 +|SW|SW|SW h|0~~7FFF|
305 +|Z|Z|Z d|0~~23|
306 +|D|D|D d|0~~7999|
307 +|SD|SD|SD d|0~~11999|
308 +
309 +**3)PLC Settings (GX Works 3)**
310 +
311 +Find the [Ethernet port] in the navigation area.
312 +
313 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_8e8f85ace087346c.png3Fwidth3D30026height3D59326rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8e8f85ace087346c.png?width=300&height=593&rev=1.1||alt="12.PLC Protocol_html_8e8f85ace087346c.png" height="593" width="300"]]
314 +
315 +Select [Own Node Settings] in the [Setting Item List];
316 +
317 +Set [IP Address], [Subnet Mask], [Default Gateway];
318 +
319 +Click [Detailed Settings] into [Ethernet Configuration (Built-in Ethernet Port)] windows;
320 +
321 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_5d98495052c8c10e.png3Fwidth3D60026height3D33926rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5d98495052c8c10e.png?width=600&height=339&rev=1.1||alt="12.PLC Protocol_html_5d98495052c8c10e.png" height="339" width="600"]]
322 +
323 +Select [SLMP Connection Module] and add into host station as below picture shows;
324 +
325 +Set Port number as 5002 (this is necessary settings);
326 +
327 +Click [Close with Reflecting the Setting] to save and close window;
328 +
329 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_14b489fdc6c6589d.png3Fwidth3D60026height3D35026rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_14b489fdc6c6589d.png?width=600&height=350&rev=1.1||alt="12.PLC Protocol_html_14b489fdc6c6589d.png" height="350" width="600"]]
330 +
331 +Click [Apply] to completed Etherenet settings;
332 +
333 +Switch to the [On line data operation] interface as below, check the item and click [Execute] to download.
334 +
335 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_c93025a968a8a9e7.png3Fwidth3D60026height3D43426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_c93025a968a8a9e7.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_c93025a968a8a9e7.png" height="434" width="600"]]
336 +
337 +**4)Configure the communication protocol**
338 +
339 +{{id name="Iimage-20220825112403-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_caa9bf4d8cc6de0f.png||alt="图片-20220825112403-1.png" height="1033" width="1920"]]
340 +
341 +**5)Cable Wiring**
342 +
343 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
344 +
345 +== {{id name="HL02Serial"/}}**L02 Serial ** ==
346 +
347 +Mitsubishi L02 series CPU built-in serial port.
348 +
349 +**1)V-BOX Settings**
350 +
351 +|**Item**|**Settings**|**Note**
352 +|Protocol|Mitsubishi L02|
353 +|Connection|RS422|
354 +|Baud rate|115200|
355 +|Data bit|8|
356 +|Parity|Odd|
357 +|Stop bit|1|
358 +|PLC station No.|1~~255|Need to be the same as PLC settings
359 +
360 +**2)Address List**
361 +
362 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
363 +|Bit|X|X|X h|0~~FFFF|
364 +|Bit|Y|Y|Y h|0~~FFFF|
365 +|Bit|M|M|M d|0~~9999|
366 +|Bit|L|L|L d|0~~9999|
367 +|Bit|F|F|F d|0~~9999|
368 +|Bit|B|B|B h|0~~FFFF|
369 +|Bit|V|V|V d|0~~2047|
370 +|Bit|TC|TC|TC d|0~~9999|
371 +|Bit|SS|SS|SS d|0~~9999|
372 +|Bit|SC|SC|SC d|0~~9999|
373 +|Bit|CS|CS|CS d|0~~9999|
374 +|Bit|CC|CC|CC d|0~~9999|
375 +|Bit|SB|SB|SB h|0~~FFFF|
376 +|Bit|SM|SM|SM d|0~~2047|
377 +|Bit|STS|STS|STS d|0~~1023|
378 +|Bit|S|S|S d|0~~9999|
379 +|Bit|DX|DX|DX h|0~~FFFF|
380 +|Bit|DY|DY|DY h|0~~FFFF|
381 +|Bit|TS|TS|TS d|0~~9999|
382 +|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15|
383 +|Word|W|W|W h|0~~FFFF|
384 +|Word|TN|TN|TN d|0~~99999|
385 +|Word|SN|SN|SN d|0~~99999|
386 +|Word|CN|CN|CN d|0~~99999|
387 +|Word|R|R|R d|0~~99999|
388 +|Word|SW|SW|SW h|0~~FFFF|
389 +|Word|Z|Z|Z d|0~~99999|
390 +|Word|ZR|ZR|ZR h|0~~FFFF|
391 +|Word|D|D|D d|0~~99999|
392 +
393 +**3)Communication Settings**
394 +
395 +{{id name="Iimage-20220825160648-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_cfed67f2ecb4ccec.png||alt="image-20220825160648-3.png" height="1009" width="1920"]]
396 +
397 +**4)Cable Wiring**
398 +
399 +* **RS422**
400 +
401 +{{id name="Iimage-20220825161612-8.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_90e38f152d639809.png||alt="image-20220825161612-8.png" height="278" width="612"]]
402 +
403 +{{id name="Iimage-20220825160820-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d301e675d8224725.png||alt="image-20220825160820-4.png" height="208" width="359"]]
404 +
405 +== {{id name="HL02Ethernet"/}}**L02 Ethernet ** ==
406 +
407 +Mitsubishi L series CPU built-in Ethernet port.
408 +
409 +**1)V-BOX Settings**
410 +
411 +|**Items**|**Settings**|**Note**
412 +|Protocol|MIT L02 CPU MELSEC|
413 +|Connection|Ethernet|
414 +|Port No.|1025|Must be the same as the PLC setting
415 +|PLC station No.|0|Must be the same as the PLC setting
416 +
417 +**2)Address List**
418 +
419 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
420 +|Bit|X|X|X h|0~~FFFF|
421 +|Bit|Y|Y|Y h|0~~FFFF|
422 +|Bit|M|M|M d|0~~9999|
423 +|Bit|L|L|L d|0~~9999|
424 +|Bit|F|F|F d|0~~9999|
425 +|Bit|B|B|B h|0~~FFFF|
426 +|Bit|V|V|V d|0~~2047|
427 +|Bit|TC|TC|TC d|0~~9999|
428 +|Bit|SS|SS|SS d|0~~9999|
429 +|Bit|SC|SC|SC d|0~~9999|
430 +|Bit|CS|CS|CS d|0~~9999|
431 +|Bit|CC|CC|CC d|0~~9999|
432 +|Bit|SB|SB|SB h|0~~FFFF|
433 +|Bit|SM|SM|SM d|0~~2047|
434 +|Bit|STS|STS|STS d|0~~1023|
435 +|Bit|S|S|S d|0~~9999|
436 +|Bit|DX|DX|DX h|0~~FFFF|
437 +|Bit|DY|DY|DY h|0~~FFFF|
438 +|Bit|TS|TS|TS d|0~~9999|
439 +|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15|
440 +|Word|W|W|W h|0~~FFFF|
441 +|Word|TN|TN|TN d|0~~99999|
442 +|Word|SN|SN|SN d|0~~99999|
443 +|Word|CN|CN|CN d|0~~99999|
444 +|Word|R|R|R d|0~~99999|
445 +|Word|SW|SW|SW h|0~~FFFF|
446 +|Word|Z|Z|Z d|0~~99999|
447 +|Word|ZR|ZR|ZR h|0~~FFFF|
448 +|Word|D|D|D d|0~~99999|
449 +
450 +**3)PLC Settings (GX Works2 )**
451 +
452 +Create a project
453 +
454 +Set PLC IP, subnet mask and gateway;
455 +
456 +Select [Binary Code] as communication data code;
457 +
458 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_776e17505f3fc6c0.png3Fwidth3D60026height3D52426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_776e17505f3fc6c0.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_776e17505f3fc6c0.png" height="524" width="600"]]
459 +
460 +Set PLC port number, for example 1025
461 +
462 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_8d0d1a22d388f70b.png3Fwidth3D60026height3D52426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8d0d1a22d388f70b.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]]
463 +
464 +Save settings;
465 +
466 +Download project into PLC device;
467 +
468 +Restart PLC device;
469 +
470 +**4)Configure the communication protocol**
471 +
472 +{{id name="Iimage-20220825142659-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_fafc9b29e20178c0.png||alt="image-20220825142659-1.png" height="1010" width="1920"]]
473 +
474 +**5)Cable Wiring**
475 +
476 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1-1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
477 +
478 +== {{id name="HQ12HSerial"/}}**Q12H Serial ** ==
479 +
480 +This Demo shows V-BOX communicate with Q12H PLC by Q02H serial Protocol
481 +
482 +**[[Download link>>url:https://ftp.we-con.com.cn/Download/WIKI/PI%20HMI/Demo/Communication/V-Box%20connect%20PLC%20Q12H.rar]]**
483 +
484 +== **QJ71E71 Ethernet ** ==
485 +
486 +Mitsubishi QJ71E71 Ethernet communication module;
487 +
488 +**1)V-BOX Settings**
489 +
490 +|**Items**|**Settings**|**Note**
491 +|Protocol|MIT QJ71E71 MELSEC|
492 +|Connection|Ethernet|
493 +|Port No.|1025|Must be the same as the PLC setting
494 +|PLC station No.|0|Must be the same as the PLC setting
495 +
496 +**2)Address List**
497 +
498 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
499 +|(% rowspan="18" %)Bit|X|X|X h|0~~1FFF|
500 +|Y|Y|Y h|0~~1FFF|
501 +|M|M|M d|0~~99999|
502 +|L|L|L d|0~~8191|
503 +|F|F|F d|0~~2047|
504 +|B|B|B h|0~~1FFF|
505 +|V|V|V d|0~~2047|
506 +|TS|TS|TS d|0~~2047|
507 +|TC|TC|TC d|0~~2047|
508 +|SS|SS|SS d|0~~2047|
509 +|SC|SC|SC d|0~~2047|
510 +|CS|CS|CS d|0~~1023|
511 +|CC|CC|CC d|0~~1023|
512 +|SB|SB|SB h|0~~7FF|
513 +|S|S|S d|0~~8191|
514 +|DX|DX|DX h|0~~1FFF|
515 +|DY|DY|DY h|0~~1FFF|
516 +|SM|SM|SM d|8000~~9999|
517 +|(% rowspan="10" %)Word|SD|SD|SD d|0~~2047|
518 +|D|D|D d|0~~12287|
519 +|W|W|W h|0~~1FFF|
520 +|TN|TN|TN d|0~~2047|
521 +|SN|SN|SN d|0~~2047|
522 +|CN|CN|CN d|0~~1023|
523 +|R|R|R d|0~~32767|
524 +|SW|SW|SW h|0~~7FF|
525 +|Z|Z|Z d|0~~15|
526 +|ZR|ZR|ZR h|0~~FE7FF|
527 +
528 +**3)PLC Settings(GX Works2)**
529 +
530 +* Click [Ethernet/CC IE/MELSECNET];
531 +* Please select [Ethernet] as network type;
532 +* Set station I/O number according to situation (For example, 0020 means that the module is connected to PLC CPU in first order);
533 +* Select [Online] as Mode;
534 +* {{id name="Iimage-20221119171343-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png||alt="image-20221119171343-2.png" height="341" width="587"]]
535 +* Click [Operation setting] to set IP;
536 +* Select [Binary Code] as [Communication Data Code];
537 +* {{id name="Iimage-20221119171436-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png||alt="image-20221119171436-3.png" height="354" width="588"]]
538 +* Click [Open setting]
539 +* Set protocol: TCP;
540 +* Set [unpassive] in [Open system];
541 +* Set [receive] in [Fixed buffer];
542 +* Set [procedure Exist] in [Fixed buffer communication];
543 +* Disable [Pairing open];
544 +* Set [No confirm] in [Existence confirmation];
545 +* Host station port number: 5009;
546 +* Save settings;
547 +* {{id name="Iimage-20221119171611-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1d8e2f4fb7c72471.png||alt="image-20221119171611-4.png" height="354" width="588"]]
548 +* Download project into PLC and restart it
549 +
550 +**4)Configure the communication protocol**
551 +
552 +{{id name="Iimage-20221119171832-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50990385ef491b9e.png||alt="image-20221119171832-5.png" height="354" width="625"]]
553 +
554 +**5)Cable Wiring**
555 +
556 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1d8e2f4fb7c72471.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +23.1 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e904556bb758dfe.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +66.0 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e9a9e29a46a1041.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +34.1 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_4d2a4921240d23c6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +123.2 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50990385ef491b9e.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +69.6 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50e173394c73f154.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +23.8 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_690b3e57b29cfd4b.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +17.8 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7c01ac15090fcc5b.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +16.4 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7f29923ebcb670d1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +106.2 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_860bcf87f6ca7b98.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +403.6 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8f49721a3e5b0ef9.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +225.5 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_90e38f152d639809.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +86.3 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9294a40c62eb99be.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +65.9 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_949d5d77c1d9cf1e.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +18.9 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b2cdc33b6eb92b67.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +68.7 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b317253742f7151.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +23.2 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_caa9bf4d8cc6de0f.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +128.1 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +43.4 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_cfed67f2ecb4ccec.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +122.7 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d022c5ff4cf8c68e.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +78.5 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d2a46ba9c005cf38.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +63.4 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d301e675d8224725.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +24.9 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +90.3 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d6fd9ce3b96f99e2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +42.2 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dbaddd53e9951a17.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +123.5 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dc262f14b14cf564.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +121.8 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dfbfdd586c855c47.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +18.7 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_e3d629103727a423.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +74.3 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_fafc9b29e20178c0.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +124.2 KB
Content