1 +== **FX1S,1N,2N Serial ** ==
2 +
3 +Supported Series: Mitsubishi FX1S, FX1N, FX2N series
4 +
5 +**V-BOX Settings**
6 +
7 +|**Item**|**Settings**|**Note**
8 +|Protocol|Mitsubishi FX1S/FX1N/FX2N|
9 +|Connection|RS422/RS485/RS232|
10 +|Baud rate|9600~~115200|
11 +|Data bit|7/8|
12 +|Parity|EVEN/Odd/None|
13 +|Stop bit|1/2|
14 +|PLC station No.|1~~255|
15 +
16 +**Address List**
17 +
18 +|**Type**|**Device registers**|**V-Box registers**|**Format**|**Range**|**Note**
19 +|(% rowspan="7" %)Bit|X|X|Xo|0~~303237|
20 +|Y|Y|Y o|0~~303237|
21 +|M|M|M d|0~~99999|
22 +|T|T|T d|0~~99999|
23 +|C|C|C d|0~~99999|
24 +|S|S|S d|0~~99999|
25 +|SM|SM|SM d|8000~~9999|
26 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237|
27 +|Y|Y|Y o|0~~303237|
28 +|M|M|M d|0~~99999|
29 +|T|T|T d|0~~99999|
30 +|C|C|C d|0~~199|
31 +|D|D|D d|0~~7999|
32 +|S|S|S d|0~~99999|
33 +|SD|SD|SD d|8000~~9999|
34 +
35 +**Configure the communication protocol**
36 +
37 +{{id name="Iimage-20220825102844-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dc262f14b14cf564.png||alt="image-20220825102844-3.png" height="1011" width="1920"]]
38 +
39 +**Cable Wiring**
40 +
41 +**RS422**
42 +
43 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9294a40c62eb99be.png||alt="image-20220825103350-4.png" height="284" width="723"]]
44 +
45 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_860bcf87f6ca7b98.png||alt="image-20220825100845-4.png" height="246" width="419"]]
46 +
47 +== **FX3U,3G,3GA Serial ** ==
48 +
49 +Supported Series: Mitsubishi FX3U, FX3G, FX3GA series
50 +
51 +**V-BOX Settings**
52 +
53 +|**Item**|**Settings**|**Note**
54 +|Protocol|Mitsubishi FX3U/3G/3GA|
55 +|Connection|RS422/RS485/RS232|
56 +|Baud rate|9600~~115200|
57 +|Data bit|7/8|
58 +|Parity|EVEN/Odd/None|
59 +|Stop bit|1/2|
60 +|PLC station No.|1~~255|
61 +
62 +**Address List**
63 +
64 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
65 +|(% rowspan="7" %)Bit|X|X|Xo|0~~303237|
66 +|Y|Y|Y o|0~~303237|
67 +|M|M|M d|0~~99999|
68 +|T|T|T d|0~~99999|
69 +|C|C|C d|0~~99999|
70 +|S|S|S d|0~~99999|
71 +|SM|SM|SM d|8000~~9999|
72 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237|
73 +|Y|Y|Y o|0~~303237|
74 +|M|M|M d|0~~99999|
75 +|T|T|T d|0~~99999|
76 +|C|C|C d|0~~199|
77 +|D|D|D d|0~~7999|
78 +|S|S|S d|0~~99999|
79 +|SD|SD|SD d|8000~~9999|
80 +
81 +**Configure the communication protocol**
82 +
83 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_4d2a4921240d23c6.png||alt="image-20220825102649-2.png" height="1009" width="1920"]]
84 +
85 +**PLC Setting**
86 +
87 +Open GX Works2, create a new PLC project or open the project that has been created.
88 +Create new project: [Project]→[New]→[Series] FXCPU→[Type] FX3G/FX3GC→[OK].
89 +
90 +(% style="text-align:center" %)
91 +[[image:1.2.png]]
92 +
93 +PLC Default Parameters:
94 +[Connection type]RS422;[Baud rate]9600, [Data bit]7, [Stop bit]1,[Parity]EVEN; [Station number]0
95 +Note:The serial port parameters should be set depending on field requirements
96 +
97 +PC and PLC connection:
98 +
99 +[All connection]→[Connection 1]→[Transfer Setup Connection1]→[Serial USB]→RS-232C: PC and PLC are connected by USB to RS232 adapter,choose corresponding [COM Port]COM 5 →[Transmission speed]9.6Kbps→[setup] →[Parity]EVEN→[Data bits]7→[Stop bits]1→[OK]
100 +
101 +(% style="text-align:center" %)
102 +[[image:1.5.1.png]]
103 +
104 +Connection test:when connection is OK,the GX Works2 prompts “Successfully connected with the FX3G/FX3GCCPU.”
105 +
106 +(% style="text-align:center" %)
107 +[[image:1.5.2.png]]
108 +
109 +**Cable Wiring**
110 +
111 +**RS422**
112 +
113 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e904556bb758dfe.png||alt="image-20220825103421-5.png" height="296" width="715"]]
114 +
115 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_860bcf87f6ca7b98.png||alt="image-20220825100845-4.png" height="246" width="419"]]
116 +
117 +== **FX NOPROTOCOL** ==
118 +
119 +Mitsubishi FX3G-RS232-BD
120 +
121 +**V-Box Settings**
122 +
123 +|=**Item**|=**Settings**|=**Note**
124 +|Protocol|Mitsubishi FX NOPROTOCOL|
125 +|Connection|RS232|
126 +|Baud rate|9600|
127 +|Data bit|7|
128 +|Parity|EVEN|
129 +|Stop bit|1|
130 +|PLC station No.|0|
131 +
132 +(% style="text-align:center" %)
133 +[[image:三菱 FN盒子通讯配置.png]]
134 +
135 +**Address List**
136 +
137 +|=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note**
138 +|(% rowspan="8" %)Bit|X|X|X o|0~~303237|
139 +|Y|Y|Y o|0~~303237|
140 +|M|M|M d|0~~99999|
141 +|T|T|T d|0~~99999|
142 +|C|C|C d|0~~99999|
143 +|S|S|S d|0~~99999|
144 +|SM|SM|SM d|8000~~9999|
145 +|Lamp|Lamp|Lamp d|0~~0|
146 +|(% rowspan="8" %)Word|X|X|X o|0~~303237|
147 +|Y|Y|Y o|0~~303237|
148 +|M|M|M d|0~~99999|
149 +|T|T|T d|0~~99999|
150 +|C|C|C d|0~~199|
151 +|D|D|D d|0~~7999|
152 +|S|S|S d|0~~99999|
153 +|SD|SD|SD d|8000~~9999|
154 +
155 +**Cable Wiring**
156 +
157 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_1717efe8d969a43c.png]]
158 +
159 +== **FX3U Ethernet ** ==
160 +
161 +Supported Modules: FX3U-ENET-ADP, FX3U-ENET-L
162 +
163 +**V-BOX Settings**
164 +
165 +|Items|Settings|Note
166 +|Protocol|Mitsubishi FX3U|
167 +|Connection|Ethernet|
168 +|Port No.|5009|Must be the same as the PLC setting
169 +|PLC station No.|0|
170 +
171 +**Address List**
172 +
173 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
174 +|(% rowspan="7" %)Bit|X|X|X OOO|0~~377|
175 +|Y|Y|Y OOO|0~~377|
176 +|M|M|M DDDD|0~~7679|
177 +|SM|SM|SM DDDD|8000~~8511|
178 +|S|S|S DDDD|0~~4095|
179 +|TS|TS|TS DDD|0~~511|
180 +|CS|CS|CS DDD|0~~255|
181 +|(% rowspan="5" %)Word|CN|CN|CN DDD|0~~199|
182 +|TN|TN|TN DDD|0~~511|
183 +|D|D|D DDDD|0~~7999|
184 +|SD|SD|SD DDDD|8000~~8511|
185 +|R|R|R DDDDD|0~~32767|
186 +
187 +**Ethernet Module Settings**
188 +
189 +FX3U-ENET-L module configuration
190 + Set up the FX3U-ENET-L Ethernet module settings as follows.
191 + Select the module location, which in this document is Module 0.
192 +
193 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_949d5d77c1d9cf1e.png||alt="image-20221116105850-1.png" height="573" width="706"]]
194 +
195 +Select "Operational setting" to enter the following screen.
196 +
197 +The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default.
198 +
199 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dfbfdd586c855c47.png||alt="image-20221116105947-1.png" height="573" width="706"]]
200 +
201 +Select "Open setting" to enter the setting interface, the settings are as follows.
202 +
203 +The third item "Protocol" selects TCP, and "Open system" selects MELSOFT connection, which allows the
204 +
205 +Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module.
206 +
207 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7c01ac15090fcc5b.png||alt="image-20221116110802-1.png" height="549" width="706"]]
208 +
209 +Click on "transter setup" - "PC side I/F setting", see the following figure.
210 +
211 +After setting, the first download must use the programming cable, as shown in the figure; after that, can
212 +
213 +use the IP set in the "Ethernet board" to communicate directly with the network cable.
214 +
215 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d6fd9ce3b96f99e2.png||alt="image-20221116110832-2.png" height="423" width="708"]]
216 +
217 +Read and write data from the Ethernet module
218 +
219 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_690b3e57b29cfd4b.png||alt="image-20221116110907-3.png" height="549" width="706"]]
220 +
221 +Set "Transter setup" to COM communication, and read or write operation as shown below
222 +
223 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b317253742f7151.png||alt="image-20221116110917-4.png" height="549" width="706"]]
224 +
225 +**PLC Settings (GX Works 2)**
226 +
227 +Create a blank FX5U project
228 +
229 +Find Current Connection in the navigation
230 +
231 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d2a46ba9c005cf38.png||alt="image-20221116111427-1.png" height="421" width="705"]]
232 +
233 +Select Connection Channel List
234 +
235 +Select Ethernet board communication
236 +
237 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8f49721a3e5b0ef9.png||alt="image-20221116111451-2.png" height="421" width="705"]]
238 +
239 +Select Ethernet Module
240 + Set the IP address of the PLC
241 +
242 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e9a9e29a46a1041.png||alt="image-20221116111509-3.png" height="666" width="699"]]
243 +
244 +Read or write PLC data, in this document is read
245 +
246 +{{id name="Iimage-20221116111651-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_e3d629103727a423.png||alt="image-20221116111651-4.png" height="416" width="697"]]
247 +
248 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7f29923ebcb670d1.png||alt="image-20221116111727-5.png" height="416" width="697"]]
249 +
250 +**Configure the communication protocol**
251 +
252 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b2cdc33b6eb92b67.png||alt="image-20221119101946-2.png" height="395" width="695"]]
253 +
254 +== **FX5U Serial ** ==
255 +
256 +Mitsubishi FX5U series PLC
257 +
258 +**V-BOX Settings**
259 +
260 +|**Item**|**Settings**|**Note**
261 +|Protocol|Mitsubishi FX5U|
262 +|Connection|RS422/RS485|
263 +|Baud rate|9600|
264 +|Data bit|7|
265 +|Parity|Odd|
266 +|Stop bit|1|
267 +|PLC station No.|1~~255|Need to be the same as PLC settings
268 +
269 +**Address List**
270 +
271 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
272 +|(% rowspan="15" %)Bit|X|X|X o|0~~303237|
273 +|Y|Y|Y o|0~~303237|
274 +|M|M|M d|0~~99999|
275 +|B|B|B h|0~~7FFF|
276 +|F|F|F d|0~~32767|
277 +|SB|SB|SB h|0~~7FFF|
278 +|TS|TS|TS d|0~~1023|
279 +|TC|TC|TC d|0~~1023|
280 +|STS|STS|STS d|0~~1023|
281 +|STC|STC|STS d|0~~1023|
282 +|CS|CS|CS d|0~~1023|
283 +|CC|CC|CC d|0~~1023|
284 +|SM|SM|SM d|0~~9999|
285 +|L|L|L d|0~~32767|
286 +|S|S|S d|0~~4095|
287 +|(% rowspan="9" %)Word|W|W|W h|0~~3FF|
288 +|TN|TN|TN d|0~~1023|
289 +|STN|STN|STN d|0~~1023|
290 +|CN|CN|CN d|0~~1023|
291 +|R|R|R d|0~~32767|
292 +|SW|SW|SW h|0~~7FFF|
293 +|Z|Z|Z d|0~~23|
294 +|D|D|D d|0~~7999|
295 +|SD|SD|SD d|0~~11999|
296 +
297 +**PLC Settings (GX Works 3)**
298 +
299 +Create a blank FX5U project
300 +
301 +Find the 485 serial port module in the system navigation bar and double click to enter the settings.
302 +
303 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5c9cb13fac1e6c93.png?width=200&height=462&rev=1.1||alt="12.PLC Protocol_html_5c9cb13fac1e6c93.png" height="462" width="200"]]
304 +
305 +Select protocol in the setting item, and set parameters.
306 +
307 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_de942589ca070228.png?width=600&height=324&rev=1.1||alt="12.PLC Protocol_html_de942589ca070228.png" height="324" width="600"]]
308 +
309 +Set station number, and [Message Pattern] (Pattern 1 or Pattern 4)
310 +
311 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_387ec7d00b5feb59.png?width=600&height=323&rev=1.1||alt="12.PLC Protocol_html_387ec7d00b5feb59.png" height="323" width="600"]]
312 +
313 +Click the [Apply] button to finish the setting.
314 +
315 +Click download and select the items as below, then click [execute] to download the configuration to PLC.
316 +
317 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_cdef1c5ec8cc2105.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_cdef1c5ec8cc2105.png" height="434" width="600"]]
318 +
319 + As soon as download is completed, connect PLC with serial port, then configure it in the [Specify Connection Destination Connection].
320 +
321 +Done.
322 +
323 +**Configure the communication protocol**
324 +
325 +{{id name="Iimage-20220825104904-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dbaddd53e9951a17.png||alt="image-20220825104904-1.png" height="1033" width="1920"]]
326 +
327 +**Cable Wiring**
328 +
329 +**RS422**
330 +
331 +{{id name="Iimage-20220825105105-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d022c5ff4cf8c68e.png||alt="image-20220825105105-2.png" height="288" width="711"]]
332 +
333 +{{id name="Iimage-20220825105533-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50e173394c73f154.png||alt="image-20220825105533-3.png" height="246" width="420"]]
334 +
335 +== **FX5U Ethernet ** ==
336 +
337 +Mitsubishi FX5U series PLC
338 +
339 +**1)V-BOX Settings**
340 +
341 +|**Items**|**Settings**|**Note**
342 +|Protocol|Mitsubishi FX5U|
343 +|Connection|Ethernet|
344 +|Port No.|5002|Must be the same as the PLC setting
345 +|PLC station No.|0|
346 +
347 +**2)Address List**
348 +
349 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
350 +|(% rowspan="15" %)Bit|X|X|X o|0~~303237|
351 +|Y|Y|Y o|0~~303237|
352 +|M|M|M d|0~~99999|
353 +|B|B|B h|0~~7FFF|
354 +|F|F|F d|0~~32767|
355 +|SB|SB|SB h|0~~7FFF|
356 +|TS|TS|TS d|0~~1023|
357 +|TC|TC|TC d|0~~1023|
358 +|STS|STS|STS d|0~~1023|
359 +|STC|STC|STS d|0~~1023|
360 +|CS|CS|CS d|0~~1023|
361 +|CC|CC|CC d|0~~1023|
362 +|SM|SM|SM d|0~~9999|
363 +|L|L|L d|0~~32767|
364 +|S|S|S d|0~~4095|
365 +|(% rowspan="9" %)Word|W|W|W h|0~~3FF|
366 +|TN|TN|TN d|0~~1023|
367 +|STN|STN|STN d|0~~1023|
368 +|CN|CN|CN d|0~~1023|
369 +|R|R|R d|0~~32767|
370 +|SW|SW|SW h|0~~7FFF|
371 +|Z|Z|Z d|0~~23|
372 +|D|D|D d|0~~7999|
373 +|SD|SD|SD d|0~~11999|
374 +
375 +**3)PLC Settings (GX Works 3)**
376 +
377 +Find the [Ethernet port] in the navigation area.
378 +
379 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_8e8f85ace087346c.png3Fwidth3D30026height3D59326rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8e8f85ace087346c.png?width=300&height=593&rev=1.1||alt="12.PLC Protocol_html_8e8f85ace087346c.png" height="593" width="300"]]
380 +
381 +Select [Own Node Settings] in the [Setting Item List];
382 +
383 +Set [IP Address], [Subnet Mask], [Default Gateway];
384 +
385 +Click [Detailed Settings] into [Ethernet Configuration (Built-in Ethernet Port)] windows;
386 +
387 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_5d98495052c8c10e.png3Fwidth3D60026height3D33926rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5d98495052c8c10e.png?width=600&height=339&rev=1.1||alt="12.PLC Protocol_html_5d98495052c8c10e.png" height="339" width="600"]]
388 +
389 +Select [SLMP Connection Module] and add into host station as below picture shows;
390 +
391 +Set Port number as 5002 (this is necessary settings);
392 +
393 +Click [Close with Reflecting the Setting] to save and close window;
394 +
395 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_14b489fdc6c6589d.png3Fwidth3D60026height3D35026rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_14b489fdc6c6589d.png?width=600&height=350&rev=1.1||alt="12.PLC Protocol_html_14b489fdc6c6589d.png" height="350" width="600"]]
396 +
397 +Click [Apply] to completed Etherenet settings;
398 +
399 +Switch to the [On line data operation] interface as below, check the item and click [Execute] to download.
400 +
401 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_c93025a968a8a9e7.png3Fwidth3D60026height3D43426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_c93025a968a8a9e7.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_c93025a968a8a9e7.png" height="434" width="600"]]
402 +
403 +**4)Configure the communication protocol**
404 +
405 +{{id name="Iimage-20220825112403-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_caa9bf4d8cc6de0f.png||alt="图片-20220825112403-1.png" height="1033" width="1920"]]
406 +
407 +**5)Cable Wiring**
408 +
409 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
410 +
411 +== **L02 Serial ** ==
412 +
413 +Mitsubishi L02 series CPU built-in serial port.
414 +
415 +**V-BOX Settings**
416 +
417 +|**Item**|**Settings**|**Note**
418 +|Protocol|Mitsubishi L02|
419 +|Connection|RS422|
420 +|Baud rate|115200|
421 +|Data bit|8|
422 +|Parity|Odd|
423 +|Stop bit|1|
424 +|PLC station No.|1~~255|Need to be the same as PLC settings
425 +
426 +**Address List**
427 +
428 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
429 +|(% colspan="1" rowspan="20" %)Bit
430 + |X|X|X h|0~~FFFF|
431 +|Y|Y|Y h|0~~FFFF|
432 +|M|M|M d|0~~9999|
433 +|L|L|L d|0~~9999|
434 +|F|F|F d|0~~9999|
435 +|B|B|B h|0~~FFFF|
436 +|V|V|V d|0~~2047|
437 +|TC|TC|TC d|0~~9999|
438 +|SS|SS|SS d|0~~9999|
439 +|SC|SC|SC d|0~~9999|
440 +|CS|CS|CS d|0~~9999|
441 +|CC|CC|CC d|0~~9999|
442 +|SB|SB|SB h|0~~FFFF|
443 +|SM|SM|SM d|0~~2047|
444 +|STS|STS|STS d|0~~1023|
445 +|S|S|S d|0~~9999|
446 +|DX|DX|DX h|0~~FFFF|
447 +|DY|DY|DY h|0~~FFFF|
448 +|TS|TS|TS d|0~~9999|
449 +|Dbit|Dbit|Dbit d.d|0~~99999.0~~15|
450 +|(% colspan="1" rowspan="9" %)Word
451 + |W|W|W h|0~~FFFF|
452 +|TN|TN|TN d|0~~99999|
453 +|SN|SN|SN d|0~~99999|
454 +|CN|CN|CN d|0~~99999|
455 +|R|R|R d|0~~99999|
456 +|SW|SW|SW h|0~~FFFF|
457 +|Z|Z|Z d|0~~99999|
458 +|ZR|ZR|ZR h|0~~FFFF|
459 +|D|D|D d|0~~99999|
460 +
461 +**Communication Settings**
462 +
463 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_cfed67f2ecb4ccec.png||alt="image-20220825160648-3.png" height="1009" width="1920"]]
464 +
465 +**Cable Wiring**
466 +
467 +**RS422**
468 +
469 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_90e38f152d639809.png||alt="image-20220825161612-8.png" height="278" width="612"]]
470 +
471 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d301e675d8224725.png||alt="image-20220825160820-4.png" height="208" width="359"]]
472 +
473 +== **L02 Ethernet ** ==
474 +
475 +Mitsubishi L series CPU built-in Ethernet port.
476 +
477 +**V-BOX Settings**
478 +
479 +|**Items**|**Settings**|**Note**
480 +|Protocol|MIT L02 CPU MELSEC|
481 +|Connection|Ethernet|
482 +|Port No.|1025|Must be the same as the PLC setting
483 +|PLC station No.|0|Must be the same as the PLC setting
484 +
485 +
486 +**PLC Settings (GX Works2 )**
487 +
488 +Create a project
489 +
490 +Set PLC IP, subnet mask and gateway;
491 +
492 +Select [Binary Code] as communication data code;
493 +
494 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_776e17505f3fc6c0.png3Fwidth3D60026height3D52426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_776e17505f3fc6c0.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_776e17505f3fc6c0.png" height="524" width="600"]]
495 +
496 +Set PLC port number, for example 1025
497 +
498 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_8d0d1a22d388f70b.png3Fwidth3D60026height3D52426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8d0d1a22d388f70b.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]]
499 +
500 +Save settings;
501 +
502 +Download project into PLC device;
503 +
504 +Restart PLC device;
505 +
506 +**4)Configure the communication protocol**
507 +
508 +{{id name="Iimage-20220825142659-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_fafc9b29e20178c0.png||alt="image-20220825142659-1.png" height="1010" width="1920"]]
509 +
510 +**5)Cable Wiring**
511 +
512 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1-1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
513 +
514 +== {{id name="HQ12HSerial"/}}**Q12H Serial ** ==
515 +
516 +This Demo shows V-BOX communicate with Q12H PLC by Q02H serial Protocol
517 +
518 +**[[Download link>>url:https://ftp.we-con.com.cn/Download/WIKI/PI%20HMI/Demo/Communication/V-Box%20connect%20PLC%20Q12H.rar]]**
519 +
520 +== **QJ71E71 Ethernet ** ==
521 +
522 +Mitsubishi QJ71E71 Ethernet communication module;
523 +
524 +**1)V-BOX Settings**
525 +
526 +|**Items**|**Settings**|**Note**
527 +|Protocol|MIT QJ71E71 MELSEC|
528 +|Connection|Ethernet|
529 +|Port No.|1025|Must be the same as the PLC setting
530 +|PLC station No.|0|Must be the same as the PLC setting
531 +
532 +**2)Address List**
533 +
534 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
535 +|(% rowspan="18" %)Bit|X|X|X h|0~~1FFF|
536 +|Y|Y|Y h|0~~1FFF|
537 +|M|M|M d|0~~99999|
538 +|L|L|L d|0~~8191|
539 +|F|F|F d|0~~2047|
540 +|B|B|B h|0~~1FFF|
541 +|V|V|V d|0~~2047|
542 +|TS|TS|TS d|0~~2047|
543 +|TC|TC|TC d|0~~2047|
544 +|SS|SS|SS d|0~~2047|
545 +|SC|SC|SC d|0~~2047|
546 +|CS|CS|CS d|0~~1023|
547 +|CC|CC|CC d|0~~1023|
548 +|SB|SB|SB h|0~~7FF|
549 +|S|S|S d|0~~8191|
550 +|DX|DX|DX h|0~~1FFF|
551 +|DY|DY|DY h|0~~1FFF|
552 +|SM|SM|SM d|8000~~9999|
553 +|(% rowspan="10" %)Word|SD|SD|SD d|0~~2047|
554 +|D|D|D d|0~~12287|
555 +|W|W|W h|0~~1FFF|
556 +|TN|TN|TN d|0~~2047|
557 +|SN|SN|SN d|0~~2047|
558 +|CN|CN|CN d|0~~1023|
559 +|R|R|R d|0~~32767|
560 +|SW|SW|SW h|0~~7FF|
561 +|Z|Z|Z d|0~~15|
562 +|ZR|ZR|ZR h|0~~FE7FF|
563 +
564 +**3)PLC Settings(GX Works2)**
565 +
566 +* Click [Ethernet/CC IE/MELSECNET];
567 +* Please select [Ethernet] as network type;
568 +* Set station I/O number according to situation (For example, 0020 means that the module is connected to PLC CPU in first order);
569 +* Select [Online] as Mode;
570 +* {{id name="Iimage-20221119171343-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png||alt="image-20221119171343-2.png" height="341" width="587"]]
571 +* Click [Operation setting] to set IP;
572 +* Select [Binary Code] as [Communication Data Code];
573 +* {{id name="Iimage-20221119171436-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png||alt="image-20221119171436-3.png" height="354" width="588"]]
574 +* Click [Open setting]
575 +* Set protocol: TCP;
576 +* Set [unpassive] in [Open system];
577 +* Set [receive] in [Fixed buffer];
578 +* Set [procedure Exist] in [Fixed buffer communication];
579 +* Disable [Pairing open];
580 +* Set [No confirm] in [Existence confirmation];
581 +* Host station port number: 5009;
582 +* Save settings;
583 +* {{id name="Iimage-20221119171611-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1d8e2f4fb7c72471.png||alt="image-20221119171611-4.png" height="354" width="588"]]
584 +* Download project into PLC and restart it
585 +
586 +**4)Configure the communication protocol**
587 +
588 +{{id name="Iimage-20221119171832-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50990385ef491b9e.png||alt="image-20221119171832-5.png" height="354" width="625"]]
589 +
590 +**5)Cable Wiring**
591 +
592 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1.2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +58.0 KB
Content
1.5.1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +103.4 KB
Content
1.5.2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +46.6 KB
Content
1694743608503-875.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +98.4 KB
Content
xwiki_PIStudio_12.PLC+protocols_WebHome_1717efe8d969a43c.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +14.8 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1d8e2f4fb7c72471.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +23.1 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e904556bb758dfe.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +66.0 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e9a9e29a46a1041.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +34.1 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_4d2a4921240d23c6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +123.2 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50990385ef491b9e.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +69.6 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50e173394c73f154.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +23.8 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_690b3e57b29cfd4b.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +17.8 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7c01ac15090fcc5b.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +16.4 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7f29923ebcb670d1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +106.2 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_860bcf87f6ca7b98.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +403.6 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8f49721a3e5b0ef9.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +225.5 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_90e38f152d639809.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +86.3 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9294a40c62eb99be.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +65.9 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_949d5d77c1d9cf1e.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +18.9 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b2cdc33b6eb92b67.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +68.7 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b317253742f7151.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +23.2 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_caa9bf4d8cc6de0f.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +128.1 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +43.4 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_cfed67f2ecb4ccec.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +122.7 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d022c5ff4cf8c68e.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +78.5 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d2a46ba9c005cf38.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +63.4 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d301e675d8224725.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +24.9 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +90.3 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d6fd9ce3b96f99e2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +42.2 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dbaddd53e9951a17.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +123.5 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dc262f14b14cf564.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +121.8 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dfbfdd586c855c47.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +18.7 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_e3d629103727a423.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +74.3 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_fafc9b29e20178c0.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +124.2 KB
Content
三菱 FN盒子通讯配置.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +65.5 KB
Content