Changes for page Mitsubishi
Last modified by Joe on 2024/05/21 10:53
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,0 @@ 1 -Mitsubishi - Content
-
... ... @@ -1,558 +1,0 @@ 1 -= {{id name="HMitsubishi"/}}**Mitsubishi ** = 2 - 3 -== {{id name="HFX1SFF0C1NFF0C2NSerial"/}}**FX1S,1N,2N Serial ** == 4 - 5 -Supported Series: Mitsubishi FX1S, FX1N, FX2N series 6 - 7 -**1)V-BOX Settings** 8 - 9 -|**Item**|**Settings**|**Note** 10 -|Protocol|Mitsubishi FX1S/FX1N/FX2N| 11 -|Connection|RS422/RS485/RS232| 12 -|Baud rate|9600~~115200| 13 -|Data bit|7/8| 14 -|Parity|EVEN/Odd/None| 15 -|Stop bit|1/2| 16 -|PLC station No.|1~~255| 17 - 18 -**2)Address List** 19 - 20 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 21 -|(% rowspan="7" %)Bit|X|X|Xo|0~~303237| 22 -|Y|Y|Y o|0~~303237| 23 -|M|M|M d|0~~99999| 24 -|T|T|T d|0~~99999| 25 -|C|C|C d|0~~99999| 26 -|S|S|S d|0~~99999| 27 -|SM|SM|SM d|8000~~9999| 28 -|(% rowspan="8" %)Word|X|X|Xo|0~~303237| 29 -|Y|Y|Y o|0~~303237| 30 -|M|M|M d|0~~99999| 31 -|T|T|T d|0~~99999| 32 -|C|C|C d|0~~199| 33 -|D|D|D d|0~~7999| 34 -|S|S|S d|0~~99999| 35 -|SD|SD|SD d|8000~~9999| 36 - 37 -**3)Configure the communication protocol** 38 - 39 -{{id name="Iimage-20220825102844-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dc262f14b14cf564.png||alt="image-20220825102844-3.png" height="1011" width="1920"]] 40 - 41 -**4)Cable Wiring** 42 - 43 -* **RS422** 44 - 45 -{{id name="Iimage-20220825103350-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9294a40c62eb99be.png||alt="image-20220825103350-4.png" height="284" width="723"]] 46 - 47 -{{id name="Iimage-20220825100845-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_860bcf87f6ca7b98.png||alt="image-20220825100845-4.png" height="246" width="419"]] 48 - 49 -== {{id name="HFX3UFF0C3GFF0C3GASerial"/}}**FX3U,3G,3GA Serial ** == 50 - 51 -Supported Series: Mitsubishi FX3U, FX3G, FX3GA series 52 - 53 -**1)V-BOX Settings** 54 - 55 -|**Item**|**Settings**|**Note** 56 -|Protocol|Mitsubishi FX3U/3G/3GA| 57 -|Connection|RS422/RS485/RS232| 58 -|Baud rate|9600~~115200| 59 -|Data bit|7/8| 60 -|Parity|EVEN/Odd/None| 61 -|Stop bit|1/2| 62 -|PLC station No.|1~~255| 63 - 64 -**2)Address List** 65 - 66 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 67 -|(% rowspan="7" %)Bit|X|X|Xo|0~~303237| 68 -|Y|Y|Y o|0~~303237| 69 -|M|M|M d|0~~99999| 70 -|T|T|T d|0~~99999| 71 -|C|C|C d|0~~99999| 72 -|S|S|S d|0~~99999| 73 -|SM|SM|SM d|8000~~9999| 74 -|(% rowspan="8" %)Word|X|X|Xo|0~~303237| 75 -|Y|Y|Y o|0~~303237| 76 -|M|M|M d|0~~99999| 77 -|T|T|T d|0~~99999| 78 -|C|C|C d|0~~199| 79 -|D|D|D d|0~~7999| 80 -|S|S|S d|0~~99999| 81 -|SD|SD|SD d|8000~~9999| 82 - 83 -**3)Configure the communication protocol** 84 - 85 -{{id name="Iimage-20220825102649-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_4d2a4921240d23c6.png||alt="image-20220825102649-2.png" height="1009" width="1920"]] 86 - 87 -**4)Cable Wiring** 88 - 89 -* **RS422** 90 - 91 -{{id name="Iimage-20220825103421-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e904556bb758dfe.png||alt="image-20220825103421-5.png" height="296" width="715"]] 92 - 93 -{{id name="Iimage-20220825100845-4.png-1"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_860bcf87f6ca7b98.png||alt="image-20220825100845-4.png" height="246" width="419"]] 94 - 95 -== {{id name="HFX3UEthernet"/}}**FX3U Ethernet ** == 96 - 97 -Supported Modules: FX3U-ENET-ADP, FX3U-ENET-L 98 - 99 -**1)V-BOX Settings** 100 - 101 -|Items|Settings|Note 102 -|Protocol|Mitsubishi FX3U| 103 -|Connection|Ethernet| 104 -|Port No.|5009|Must be the same as the PLC setting 105 -|PLC station No.|0| 106 - 107 -**2)Address List** 108 - 109 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 110 -|(% rowspan="7" %)Bit|X|X|X OOO|0~~377| 111 -|Y|Y|Y OOO|0~~377| 112 -|M|M|M DDDD|0~~7679| 113 -|SM|SM|SM DDDD|8000~~8511| 114 -|S|S|S DDDD|0~~4095| 115 -|TS|TS|TS DDD|0~~511| 116 -|CS|CS|CS DDD|0~~255| 117 -|(% rowspan="5" %)Word|CN|CN|CN DDD|0~~199| 118 -|TN|TN|TN DDD|0~~511| 119 -|D|D|D DDDD|0~~7999| 120 -|SD|SD|SD DDDD|8000~~8511| 121 -|R|R|R DDDDD|0~~32767| 122 - 123 -**3)Ethernet Module Settings** 124 - 125 -FX3U-ENET-L module configuration 126 - Set up the FX3U-ENET-L Ethernet module settings as follows. 127 - Select the module location, which in this document is Module 0. 128 - 129 -{{id name="Iimage-20221116105850-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_949d5d77c1d9cf1e.png||alt="image-20221116105850-1.png" height="573" width="706"]] 130 - 131 -Select "Operational setting" to enter the following screen. 132 - 133 -The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default. 134 - 135 -{{id name="Iimage-20221116105947-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dfbfdd586c855c47.png||alt="image-20221116105947-1.png" height="573" width="706"]] 136 - 137 -Select "Open setting" to enter the setting interface, the settings are as follows. 138 - 139 -The third item "Protocol" selects TCP, and "Open system" selects MELSOFT connection, which allows the 140 - 141 -Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module. 142 - 143 -{{id name="Iimage-20221116110802-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7c01ac15090fcc5b.png||alt="image-20221116110802-1.png" height="549" width="706"]] 144 - 145 -Click on "transter setup" - "PC side I/F setting", see the following figure. 146 - 147 -After setting, the first download must use the programming cable, as shown in the figure; after that, can 148 - 149 -use the IP set in the "Ethernet board" to communicate directly with the network cable. 150 - 151 -{{id name="Iimage-20221116110832-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d6fd9ce3b96f99e2.png||alt="image-20221116110832-2.png" height="423" width="708"]] 152 - 153 -Read and write data from the Ethernet module 154 - 155 -{{id name="Iimage-20221116110907-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_690b3e57b29cfd4b.png||alt="image-20221116110907-3.png" height="549" width="706"]] 156 - 157 -Set "Transter setup" to COM communication, and read or write operation as shown below 158 - 159 -{{id name="Iimage-20221116110917-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b317253742f7151.png||alt="image-20221116110917-4.png" height="549" width="706"]] 160 - 161 -**4)PLC Settings (GX Works 2)** 162 - 163 -Create a blank FX5U project 164 - 165 -Find Current Connection in the navigation 166 - 167 -{{id name="Iimage-20221116111427-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d2a46ba9c005cf38.png||alt="image-20221116111427-1.png" height="421" width="705"]] 168 - 169 -Select Connection Channel List 170 - 171 -Select Ethernet board communication 172 - 173 -{{id name="Iimage-20221116111451-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8f49721a3e5b0ef9.png||alt="image-20221116111451-2.png" height="421" width="705"]] 174 - 175 -Select Ethernet Module 176 - Set the IP address of the PLC 177 - 178 -{{id name="Iimage-20221116111509-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e9a9e29a46a1041.png||alt="image-20221116111509-3.png" height="666" width="699"]] 179 - 180 -Read or write PLC data, in this document is read 181 - 182 -{{id name="Iimage-20221116111651-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_e3d629103727a423.png||alt="image-20221116111651-4.png" height="416" width="697"]] 183 - 184 -{{id name="Iimage-20221116111727-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7f29923ebcb670d1.png||alt="image-20221116111727-5.png" height="416" width="697"]] 185 - 186 -**4)Configure the communication protocol** 187 - 188 -{{id name="Iimage-20221119101946-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b2cdc33b6eb92b67.png||alt="image-20221119101946-2.png" height="395" width="695"]] 189 - 190 -== {{id name="HFX5USerial"/}}**FX5U Serial ** == 191 - 192 -Mitsubishi FX5U series PLC 193 - 194 -**1)V-BOX Settings** 195 - 196 -|**Item**|**Settings**|**Note** 197 -|Protocol|Mitsubishi FX5U| 198 -|Connection|RS422/RS485| 199 -|Baud rate|9600| 200 -|Data bit|7| 201 -|Parity|Odd| 202 -|Stop bit|1| 203 -|PLC station No.|1~~255|Need to be the same as PLC settings 204 - 205 -**2)Address List** 206 - 207 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 208 -|(% rowspan="15" %)Bit|X|X|X o|0~~303237| 209 -|Y|Y|Y o|0~~303237| 210 -|M|M|M d|0~~99999| 211 -|B|B|B h|0~~7FFF| 212 -|F|F|F d|0~~32767| 213 -|SB|SB|SB h|0~~7FFF| 214 -|TS|TS|TS d|0~~1023| 215 -|TC|TC|TC d|0~~1023| 216 -|STS|STS|STS d|0~~1023| 217 -|STC|STC|STS d|0~~1023| 218 -|CS|CS|CS d|0~~1023| 219 -|CC|CC|CC d|0~~1023| 220 -|SM|SM|SM d|0~~9999| 221 -|L|L|L d|0~~32767| 222 -|S|S|S d|0~~4095| 223 -|(% rowspan="9" %)Word|W|W|W h|0~~3FF| 224 -|TN|TN|TN d|0~~1023| 225 -|STN|STN|STN d|0~~1023| 226 -|CN|CN|CN d|0~~1023| 227 -|R|R|R d|0~~32767| 228 -|SW|SW|SW h|0~~7FFF| 229 -|Z|Z|Z d|0~~23| 230 -|D|D|D d|0~~7999| 231 -|SD|SD|SD d|0~~11999| 232 - 233 -**3)PLC Settings (GX Works 3)** 234 - 235 -Create a blank FX5U project 236 - 237 -Find the 485 serial port module in the system navigation bar and double click to enter the settings. 238 - 239 -{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_5c9cb13fac1e6c93.png3Fwidth3D20026height3D46226rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5c9cb13fac1e6c93.png?width=200&height=462&rev=1.1||alt="12.PLC Protocol_html_5c9cb13fac1e6c93.png" height="462" width="200"]] 240 - 241 -Select protocol in the setting item, and set parameters. 242 - 243 -{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_de942589ca070228.png3Fwidth3D60026height3D32426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_de942589ca070228.png?width=600&height=324&rev=1.1||alt="12.PLC Protocol_html_de942589ca070228.png" height="324" width="600"]] 244 - 245 -Set station number, and [Message Pattern] (Pattern 1 or Pattern 4) 246 - 247 -{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_387ec7d00b5feb59.png3Fwidth3D60026height3D32326rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_387ec7d00b5feb59.png?width=600&height=323&rev=1.1||alt="12.PLC Protocol_html_387ec7d00b5feb59.png" height="323" width="600"]] 248 - 249 -Click the [Apply] button to finish the setting. 250 - 251 -Click download and select the items as below, then click [execute] to download the configuration to PLC. 252 - 253 -{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_cdef1c5ec8cc2105.png3Fwidth3D60026height3D43426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_cdef1c5ec8cc2105.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_cdef1c5ec8cc2105.png" height="434" width="600"]] 254 - 255 - As soon as download is completed, connect PLC with serial port, then configure it in the [Specify Connection Destination Connection]. 256 - 257 -Done. 258 - 259 -**4)Configure the communication protocol** 260 - 261 -{{id name="Iimage-20220825104904-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dbaddd53e9951a17.png||alt="image-20220825104904-1.png" height="1033" width="1920"]] 262 - 263 -**5)Cable Wiring** 264 - 265 -* **RS422** 266 - 267 -{{id name="Iimage-20220825105105-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d022c5ff4cf8c68e.png||alt="image-20220825105105-2.png" height="288" width="711"]] 268 - 269 -{{id name="Iimage-20220825105533-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50e173394c73f154.png||alt="image-20220825105533-3.png" height="246" width="420"]] 270 - 271 -== {{id name="HFX5UEthernet"/}}**FX5U Ethernet ** == 272 - 273 -Mitsubishi FX5U series PLC 274 - 275 -**1)V-BOX Settings** 276 - 277 -|**Items**|**Settings**|**Note** 278 -|Protocol|Mitsubishi FX5U| 279 -|Connection|Ethernet| 280 -|Port No.|5002|Must be the same as the PLC setting 281 -|PLC station No.|0| 282 - 283 -**2)Address List** 284 - 285 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 286 -|(% rowspan="15" %)Bit|X|X|X o|0~~303237| 287 -|Y|Y|Y o|0~~303237| 288 -|M|M|M d|0~~99999| 289 -|B|B|B h|0~~7FFF| 290 -|F|F|F d|0~~32767| 291 -|SB|SB|SB h|0~~7FFF| 292 -|TS|TS|TS d|0~~1023| 293 -|TC|TC|TC d|0~~1023| 294 -|STS|STS|STS d|0~~1023| 295 -|STC|STC|STS d|0~~1023| 296 -|CS|CS|CS d|0~~1023| 297 -|CC|CC|CC d|0~~1023| 298 -|SM|SM|SM d|0~~9999| 299 -|L|L|L d|0~~32767| 300 -|S|S|S d|0~~4095| 301 -|(% rowspan="9" %)Word|W|W|W h|0~~3FF| 302 -|TN|TN|TN d|0~~1023| 303 -|STN|STN|STN d|0~~1023| 304 -|CN|CN|CN d|0~~1023| 305 -|R|R|R d|0~~32767| 306 -|SW|SW|SW h|0~~7FFF| 307 -|Z|Z|Z d|0~~23| 308 -|D|D|D d|0~~7999| 309 -|SD|SD|SD d|0~~11999| 310 - 311 -**3)PLC Settings (GX Works 3)** 312 - 313 -Find the [Ethernet port] in the navigation area. 314 - 315 -{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_8e8f85ace087346c.png3Fwidth3D30026height3D59326rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8e8f85ace087346c.png?width=300&height=593&rev=1.1||alt="12.PLC Protocol_html_8e8f85ace087346c.png" height="593" width="300"]] 316 - 317 -Select [Own Node Settings] in the [Setting Item List]; 318 - 319 -Set [IP Address], [Subnet Mask], [Default Gateway]; 320 - 321 -Click [Detailed Settings] into [Ethernet Configuration (Built-in Ethernet Port)] windows; 322 - 323 -{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_5d98495052c8c10e.png3Fwidth3D60026height3D33926rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5d98495052c8c10e.png?width=600&height=339&rev=1.1||alt="12.PLC Protocol_html_5d98495052c8c10e.png" height="339" width="600"]] 324 - 325 -Select [SLMP Connection Module] and add into host station as below picture shows; 326 - 327 -Set Port number as 5002 (this is necessary settings); 328 - 329 -Click [Close with Reflecting the Setting] to save and close window; 330 - 331 -{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_14b489fdc6c6589d.png3Fwidth3D60026height3D35026rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_14b489fdc6c6589d.png?width=600&height=350&rev=1.1||alt="12.PLC Protocol_html_14b489fdc6c6589d.png" height="350" width="600"]] 332 - 333 -Click [Apply] to completed Etherenet settings; 334 - 335 -Switch to the [On line data operation] interface as below, check the item and click [Execute] to download. 336 - 337 -{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_c93025a968a8a9e7.png3Fwidth3D60026height3D43426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_c93025a968a8a9e7.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_c93025a968a8a9e7.png" height="434" width="600"]] 338 - 339 -**4)Configure the communication protocol** 340 - 341 -{{id name="Iimage-20220825112403-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_caa9bf4d8cc6de0f.png||alt="图片-20220825112403-1.png" height="1033" width="1920"]] 342 - 343 -**5)Cable Wiring** 344 - 345 -{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 346 - 347 -== {{id name="HL02Serial"/}}**L02 Serial ** == 348 - 349 -Mitsubishi L02 series CPU built-in serial port. 350 - 351 -**1)V-BOX Settings** 352 - 353 -|**Item**|**Settings**|**Note** 354 -|Protocol|Mitsubishi L02| 355 -|Connection|RS422| 356 -|Baud rate|115200| 357 -|Data bit|8| 358 -|Parity|Odd| 359 -|Stop bit|1| 360 -|PLC station No.|1~~255|Need to be the same as PLC settings 361 - 362 -**2)Address List** 363 - 364 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 365 -|Bit|X|X|X h|0~~FFFF| 366 -|Bit|Y|Y|Y h|0~~FFFF| 367 -|Bit|M|M|M d|0~~9999| 368 -|Bit|L|L|L d|0~~9999| 369 -|Bit|F|F|F d|0~~9999| 370 -|Bit|B|B|B h|0~~FFFF| 371 -|Bit|V|V|V d|0~~2047| 372 -|Bit|TC|TC|TC d|0~~9999| 373 -|Bit|SS|SS|SS d|0~~9999| 374 -|Bit|SC|SC|SC d|0~~9999| 375 -|Bit|CS|CS|CS d|0~~9999| 376 -|Bit|CC|CC|CC d|0~~9999| 377 -|Bit|SB|SB|SB h|0~~FFFF| 378 -|Bit|SM|SM|SM d|0~~2047| 379 -|Bit|STS|STS|STS d|0~~1023| 380 -|Bit|S|S|S d|0~~9999| 381 -|Bit|DX|DX|DX h|0~~FFFF| 382 -|Bit|DY|DY|DY h|0~~FFFF| 383 -|Bit|TS|TS|TS d|0~~9999| 384 -|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15| 385 -|Word|W|W|W h|0~~FFFF| 386 -|Word|TN|TN|TN d|0~~99999| 387 -|Word|SN|SN|SN d|0~~99999| 388 -|Word|CN|CN|CN d|0~~99999| 389 -|Word|R|R|R d|0~~99999| 390 -|Word|SW|SW|SW h|0~~FFFF| 391 -|Word|Z|Z|Z d|0~~99999| 392 -|Word|ZR|ZR|ZR h|0~~FFFF| 393 -|Word|D|D|D d|0~~99999| 394 - 395 -**3)Communication Settings** 396 - 397 -{{id name="Iimage-20220825160648-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_cfed67f2ecb4ccec.png||alt="image-20220825160648-3.png" height="1009" width="1920"]] 398 - 399 -**4)Cable Wiring** 400 - 401 -* **RS422** 402 - 403 -{{id name="Iimage-20220825161612-8.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_90e38f152d639809.png||alt="image-20220825161612-8.png" height="278" width="612"]] 404 - 405 -{{id name="Iimage-20220825160820-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d301e675d8224725.png||alt="image-20220825160820-4.png" height="208" width="359"]] 406 - 407 -== {{id name="HL02Ethernet"/}}**L02 Ethernet ** == 408 - 409 -Mitsubishi L series CPU built-in Ethernet port. 410 - 411 -**1)V-BOX Settings** 412 - 413 -|**Items**|**Settings**|**Note** 414 -|Protocol|MIT L02 CPU MELSEC| 415 -|Connection|Ethernet| 416 -|Port No.|1025|Must be the same as the PLC setting 417 -|PLC station No.|0|Must be the same as the PLC setting 418 - 419 -**2)Address List** 420 - 421 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 422 -|Bit|X|X|X h|0~~FFFF| 423 -|Bit|Y|Y|Y h|0~~FFFF| 424 -|Bit|M|M|M d|0~~9999| 425 -|Bit|L|L|L d|0~~9999| 426 -|Bit|F|F|F d|0~~9999| 427 -|Bit|B|B|B h|0~~FFFF| 428 -|Bit|V|V|V d|0~~2047| 429 -|Bit|TC|TC|TC d|0~~9999| 430 -|Bit|SS|SS|SS d|0~~9999| 431 -|Bit|SC|SC|SC d|0~~9999| 432 -|Bit|CS|CS|CS d|0~~9999| 433 -|Bit|CC|CC|CC d|0~~9999| 434 -|Bit|SB|SB|SB h|0~~FFFF| 435 -|Bit|SM|SM|SM d|0~~2047| 436 -|Bit|STS|STS|STS d|0~~1023| 437 -|Bit|S|S|S d|0~~9999| 438 -|Bit|DX|DX|DX h|0~~FFFF| 439 -|Bit|DY|DY|DY h|0~~FFFF| 440 -|Bit|TS|TS|TS d|0~~9999| 441 -|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15| 442 -|Word|W|W|W h|0~~FFFF| 443 -|Word|TN|TN|TN d|0~~99999| 444 -|Word|SN|SN|SN d|0~~99999| 445 -|Word|CN|CN|CN d|0~~99999| 446 -|Word|R|R|R d|0~~99999| 447 -|Word|SW|SW|SW h|0~~FFFF| 448 -|Word|Z|Z|Z d|0~~99999| 449 -|Word|ZR|ZR|ZR h|0~~FFFF| 450 -|Word|D|D|D d|0~~99999| 451 - 452 -**3)PLC Settings (GX Works2 )** 453 - 454 -Create a project 455 - 456 -Set PLC IP, subnet mask and gateway; 457 - 458 -Select [Binary Code] as communication data code; 459 - 460 -{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_776e17505f3fc6c0.png3Fwidth3D60026height3D52426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_776e17505f3fc6c0.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_776e17505f3fc6c0.png" height="524" width="600"]] 461 - 462 -Set PLC port number, for example 1025 463 - 464 -{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_8d0d1a22d388f70b.png3Fwidth3D60026height3D52426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8d0d1a22d388f70b.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]] 465 - 466 -Save settings; 467 - 468 -Download project into PLC device; 469 - 470 -Restart PLC device; 471 - 472 -**4)Configure the communication protocol** 473 - 474 -{{id name="Iimage-20220825142659-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_fafc9b29e20178c0.png||alt="image-20220825142659-1.png" height="1010" width="1920"]] 475 - 476 -**5)Cable Wiring** 477 - 478 -{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1-1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 479 - 480 -== {{id name="HQ12HSerial"/}}**Q12H Serial ** == 481 - 482 -This Demo shows V-BOX communicate with Q12H PLC by Q02H serial Protocol 483 - 484 -**[[Download link>>url:https://ftp.we-con.com.cn/Download/WIKI/PI%20HMI/Demo/Communication/V-Box%20connect%20PLC%20Q12H.rar]]** 485 - 486 -== {{id name="HQJ71E71Ethernet"/}}**QJ71E71 Ethernet ** == 487 - 488 -Mitsubishi QJ71E71 Ethernet communication module; 489 - 490 -**1)V-BOX Settings** 491 - 492 -|**Items**|**Settings**|**Note** 493 -|Protocol|MIT QJ71E71 MELSEC| 494 -|Connection|Ethernet| 495 -|Port No.|1025|Must be the same as the PLC setting 496 -|PLC station No.|0|Must be the same as the PLC setting 497 - 498 -**2)Address List** 499 - 500 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 501 -|(% rowspan="18" %)Bit|X|X|X h|0~~1FFF| 502 -|Y|Y|Y h|0~~1FFF| 503 -|M|M|M d|0~~99999| 504 -|L|L|L d|0~~8191| 505 -|F|F|F d|0~~2047| 506 -|B|B|B h|0~~1FFF| 507 -|V|V|V d|0~~2047| 508 -|TS|TS|TS d|0~~2047| 509 -|TC|TC|TC d|0~~2047| 510 -|SS|SS|SS d|0~~2047| 511 -|SC|SC|SC d|0~~2047| 512 -|CS|CS|CS d|0~~1023| 513 -|CC|CC|CC d|0~~1023| 514 -|SB|SB|SB h|0~~7FF| 515 -|S|S|S d|0~~8191| 516 -|DX|DX|DX h|0~~1FFF| 517 -|DY|DY|DY h|0~~1FFF| 518 -|SM|SM|SM d|8000~~9999| 519 -|(% rowspan="10" %)Word|SD|SD|SD d|0~~2047| 520 -|D|D|D d|0~~12287| 521 -|W|W|W h|0~~1FFF| 522 -|TN|TN|TN d|0~~2047| 523 -|SN|SN|SN d|0~~2047| 524 -|CN|CN|CN d|0~~1023| 525 -|R|R|R d|0~~32767| 526 -|SW|SW|SW h|0~~7FF| 527 -|Z|Z|Z d|0~~15| 528 -|ZR|ZR|ZR h|0~~FE7FF| 529 - 530 -**3)PLC Settings(GX Works2)** 531 - 532 -* Click [Ethernet/CC IE/MELSECNET]; 533 -* Please select [Ethernet] as network type; 534 -* Set station I/O number according to situation (For example, 0020 means that the module is connected to PLC CPU in first order); 535 -* Select [Online] as Mode; 536 -* {{id name="Iimage-20221119171343-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png||alt="image-20221119171343-2.png" height="341" width="587"]] 537 -* Click [Operation setting] to set IP; 538 -* Select [Binary Code] as [Communication Data Code]; 539 -* {{id name="Iimage-20221119171436-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png||alt="image-20221119171436-3.png" height="354" width="588"]] 540 -* Click [Open setting] 541 -* Set protocol: TCP; 542 -* Set [unpassive] in [Open system]; 543 -* Set [receive] in [Fixed buffer]; 544 -* Set [procedure Exist] in [Fixed buffer communication]; 545 -* Disable [Pairing open]; 546 -* Set [No confirm] in [Existence confirmation]; 547 -* Host station port number: 5009; 548 -* Save settings; 549 -* {{id name="Iimage-20221119171611-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1d8e2f4fb7c72471.png||alt="image-20221119171611-4.png" height="354" width="588"]] 550 -* Download project into PLC and restart it 551 - 552 -**4)Configure the communication protocol** 553 - 554 -{{id name="Iimage-20221119171832-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50990385ef491b9e.png||alt="image-20221119171832-5.png" height="354" width="625"]] 555 - 556 -**5)Cable Wiring** 557 - 558 -{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1-2"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="38" width="76"]]