Changes for page Mitsubishi

Last modified by Joe on 2024/05/21 10:53

From version 38.1
edited by Theodore Xu
on 2023/09/15 09:38
Change comment: There is no comment for this version
To version 47.1
edited by Theodore Xu
on 2023/09/15 10:37
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,4 +1,4 @@
1 -= **FX1S,1N,2N Serial ** =
1 +== **FX1S,1N,2N Serial ** ==
2 2  
3 3  Supported Series: Mitsubishi FX1S, FX1N, FX2N series
4 4  
... ... @@ -44,7 +44,7 @@
44 44  
45 45  [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_860bcf87f6ca7b98.png||alt="image-20220825100845-4.png" height="246" width="419"]]
46 46  
47 -== **FX3U3G3GA Serial ** ==
47 +== **FX3U,3G,3GA Serial ** ==
48 48  
49 49  Supported Series: Mitsubishi FX3U, FX3G, FX3GA series
50 50  
... ... @@ -82,8 +82,32 @@
82 82  
83 83  [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_4d2a4921240d23c6.png||alt="image-20220825102649-2.png" height="1009" width="1920"]]
84 84  
85 -**4)Cable Wiring**
85 +**PLC Setting**
86 86  
87 +Open GX Works2, create a new PLC project or open the project that has been created.
88 +Create new project: [Project]→[New]→[Series] FXCPU→[Type] FX3G/FX3GC→[OK].
89 +
90 +(% style="text-align:center" %)
91 +[[image:1.2.png]]
92 +
93 +PLC Default Parameters:
94 +[Connection type]RS422;[Baud rate]9600, [Data bit]7, [Stop bit]1,[Parity]EVEN; [Station number]0
95 +Note:The serial port parameters should be set depending on field requirements
96 +
97 +PC and PLC connection:
98 +
99 +[All connection]→[Connection 1]→[Transfer Setup Connection1]→[Serial USB]→RS-232C: PC and PLC are connected by USB to RS232 adapter,choose corresponding [COM Port]COM 5 →[Transmission speed]9.6Kbps→[setup] →[Parity]EVEN→[Data bits]7→[Stop bits]1→[OK]
100 +
101 +(% style="text-align:center" %)
102 +[[image:1.5.1.png]]
103 +
104 +Connection test:when connection is OK,the GX Works2 prompts “Successfully connected with the FX3G/FX3GCCPU.”
105 +
106 +(% style="text-align:center" %)
107 +[[image:1.5.2.png]]
108 +
109 +**Cable Wiring**
110 +
87 87  **RS422**
88 88  
89 89  [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e904556bb758dfe.png||alt="image-20220825103421-5.png" height="296" width="715"]]
... ... @@ -90,11 +90,53 @@
90 90  
91 91  [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_860bcf87f6ca7b98.png||alt="image-20220825100845-4.png" height="246" width="419"]]
92 92  
93 -== {{id name="HFX3UEthernet"/}}**FX3U Ethernet ** ==
117 +== **FX NOPROTOCOL** ==
94 94  
119 +Mitsubishi FX3G-RS232-BD
120 +
121 +**V-Box Settings**
122 +
123 +|=**Item**|=**Settings**|=**Note**
124 +|Protocol|Mitsubishi FX NOPROTOCOL|
125 +|Connection|RS232|
126 +|Baud rate|9600|
127 +|Data bit|7|
128 +|Parity|EVEN|
129 +|Stop bit|1|
130 +|PLC station No.|0|
131 +
132 +(% style="text-align:center" %)
133 +[[image:三菱 FN盒子通讯配置.png]]
134 +
135 +**Address List**
136 +
137 +|=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note**
138 +|(% rowspan="8" %)Bit|X|X|X o|0~~303237|
139 +|Y|Y|Y o|0~~303237|
140 +|M|M|M d|0~~99999|
141 +|T|T|T d|0~~99999|
142 +|C|C|C d|0~~99999|
143 +|S|S|S d|0~~99999|
144 +|SM|SM|SM d|8000~~9999|
145 +|Lamp|Lamp|Lamp d|0~~0|
146 +|(% rowspan="8" %)Word|X|X|X o|0~~303237|
147 +|Y|Y|Y o|0~~303237|
148 +|M|M|M d|0~~99999|
149 +|T|T|T d|0~~99999|
150 +|C|C|C d|0~~199|
151 +|D|D|D d|0~~7999|
152 +|S|S|S d|0~~99999|
153 +|SD|SD|SD d|8000~~9999|
154 +
155 +**Cable Wiring**
156 +
157 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_1717efe8d969a43c.png]]
158 +
159 +== **FX3U Ethernet ** ==
160 +
95 95  Supported Modules: FX3U-ENET-ADP, FX3U-ENET-L
96 96  
97 -**1)V-BOX Settings**
163 +**V-BOX Settings**
98 98  
99 99  |Items|Settings|Note
100 100  |Protocol|Mitsubishi FX3U|
... ... @@ -102,7 +102,7 @@
102 102  |Port No.|5009|Must be the same as the PLC setting
103 103  |PLC station No.|0|
104 104  
105 -**2)Address List**
171 +**Address List**
106 106  
107 107  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
108 108  |(% rowspan="7" %)Bit|X|X|X OOO|0~~377|
... ... @@ -118,19 +118,19 @@
118 118  |SD|SD|SD DDDD|8000~~8511|
119 119  |R|R|R DDDDD|0~~32767|
120 120  
121 -**3)Ethernet Module Settings**
187 +**Ethernet Module Settings**
122 122  
123 123  FX3U-ENET-L module configuration
124 124   Set up the FX3U-ENET-L Ethernet module settings as follows.
125 125   Select the module location, which in this document is Module 0.
126 126  
127 -{{id name="Iimage-20221116105850-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_949d5d77c1d9cf1e.png||alt="image-20221116105850-1.png" height="573" width="706"]]
193 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_949d5d77c1d9cf1e.png||alt="image-20221116105850-1.png" height="573" width="706"]]
128 128  
129 129  Select "Operational setting" to enter the following screen.
130 130  
131 131  The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default.
132 132  
133 -{{id name="Iimage-20221116105947-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dfbfdd586c855c47.png||alt="image-20221116105947-1.png" height="573" width="706"]]
199 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dfbfdd586c855c47.png||alt="image-20221116105947-1.png" height="573" width="706"]]
134 134  
135 135  Select "Open setting" to enter the setting interface, the settings are as follows.
136 136  
... ... @@ -138,7 +138,7 @@
138 138  
139 139  Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module.
140 140  
141 -{{id name="Iimage-20221116110802-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7c01ac15090fcc5b.png||alt="image-20221116110802-1.png" height="549" width="706"]]
207 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7c01ac15090fcc5b.png||alt="image-20221116110802-1.png" height="549" width="706"]]
142 142  
143 143  Click on "transter setup" - "PC side I/F setting", see the following figure.
144 144  
... ... @@ -146,50 +146,50 @@
146 146  
147 147  use the IP set in the "Ethernet board" to communicate directly with the network cable.
148 148  
149 -{{id name="Iimage-20221116110832-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d6fd9ce3b96f99e2.png||alt="image-20221116110832-2.png" height="423" width="708"]]
215 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d6fd9ce3b96f99e2.png||alt="image-20221116110832-2.png" height="423" width="708"]]
150 150  
151 151  Read and write data from the Ethernet module
152 152  
153 -{{id name="Iimage-20221116110907-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_690b3e57b29cfd4b.png||alt="image-20221116110907-3.png" height="549" width="706"]]
219 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_690b3e57b29cfd4b.png||alt="image-20221116110907-3.png" height="549" width="706"]]
154 154  
155 155  Set "Transter setup" to COM communication, and read or write operation as shown below
156 156  
157 -{{id name="Iimage-20221116110917-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b317253742f7151.png||alt="image-20221116110917-4.png" height="549" width="706"]]
223 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b317253742f7151.png||alt="image-20221116110917-4.png" height="549" width="706"]]
158 158  
159 -**4)PLC Settings (GX Works 2)**
225 +**PLC Settings (GX Works 2)**
160 160  
161 161  Create a blank FX5U project
162 162  
163 163  Find Current Connection in the navigation
164 164  
165 -{{id name="Iimage-20221116111427-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d2a46ba9c005cf38.png||alt="image-20221116111427-1.png" height="421" width="705"]]
231 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d2a46ba9c005cf38.png||alt="image-20221116111427-1.png" height="421" width="705"]]
166 166  
167 167  Select Connection Channel List
168 168  
169 169  Select Ethernet board communication
170 170  
171 -{{id name="Iimage-20221116111451-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8f49721a3e5b0ef9.png||alt="image-20221116111451-2.png" height="421" width="705"]]
237 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8f49721a3e5b0ef9.png||alt="image-20221116111451-2.png" height="421" width="705"]]
172 172  
173 173  Select Ethernet Module
174 174   Set the IP address of the PLC
175 175  
176 -{{id name="Iimage-20221116111509-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e9a9e29a46a1041.png||alt="image-20221116111509-3.png" height="666" width="699"]]
242 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e9a9e29a46a1041.png||alt="image-20221116111509-3.png" height="666" width="699"]]
177 177  
178 178  Read or write PLC data, in this document is read
179 179  
180 180  {{id name="Iimage-20221116111651-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_e3d629103727a423.png||alt="image-20221116111651-4.png" height="416" width="697"]]
181 181  
182 -{{id name="Iimage-20221116111727-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7f29923ebcb670d1.png||alt="image-20221116111727-5.png" height="416" width="697"]]
248 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7f29923ebcb670d1.png||alt="image-20221116111727-5.png" height="416" width="697"]]
183 183  
184 -**4)Configure the communication protocol**
250 +**Configure the communication protocol**
185 185  
186 -{{id name="Iimage-20221119101946-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b2cdc33b6eb92b67.png||alt="image-20221119101946-2.png" height="395" width="695"]]
252 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b2cdc33b6eb92b67.png||alt="image-20221119101946-2.png" height="395" width="695"]]
187 187  
188 -== {{id name="HFX5USerial"/}}**FX5U Serial ** ==
254 +== **FX5U Serial ** ==
189 189  
190 190  Mitsubishi FX5U series PLC
191 191  
192 -**1)V-BOX Settings**
258 +**V-BOX Settings**
193 193  
194 194  |**Item**|**Settings**|**Note**
195 195  |Protocol|Mitsubishi FX5U|
... ... @@ -200,7 +200,7 @@
200 200  |Stop bit|1|
201 201  |PLC station No.|1~~255|Need to be the same as PLC settings
202 202  
203 -**2)Address List**
269 +**Address List**
204 204  
205 205  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
206 206  |(% rowspan="15" %)Bit|X|X|X o|0~~303237|
... ... @@ -228,39 +228,39 @@
228 228  |D|D|D d|0~~7999|
229 229  |SD|SD|SD d|0~~11999|
230 230  
231 -**3)PLC Settings (GX Works 3)**
297 +**PLC Settings (GX Works 3)**
232 232  
233 233  Create a blank FX5U project
234 234  
235 235  Find the 485 serial port module in the system navigation bar and double click to enter the settings.
236 236  
237 -{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_5c9cb13fac1e6c93.png3Fwidth3D20026height3D46226rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5c9cb13fac1e6c93.png?width=200&height=462&rev=1.1||alt="12.PLC Protocol_html_5c9cb13fac1e6c93.png" height="462" width="200"]]
303 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5c9cb13fac1e6c93.png?width=200&height=462&rev=1.1||alt="12.PLC Protocol_html_5c9cb13fac1e6c93.png" height="462" width="200"]]
238 238  
239 239  Select protocol in the setting item, and set parameters.
240 240  
241 -{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_de942589ca070228.png3Fwidth3D60026height3D32426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_de942589ca070228.png?width=600&height=324&rev=1.1||alt="12.PLC Protocol_html_de942589ca070228.png" height="324" width="600"]]
307 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_de942589ca070228.png?width=600&height=324&rev=1.1||alt="12.PLC Protocol_html_de942589ca070228.png" height="324" width="600"]]
242 242  
243 243  Set station number, and [Message Pattern] (Pattern 1 or Pattern 4)
244 244  
245 -{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_387ec7d00b5feb59.png3Fwidth3D60026height3D32326rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_387ec7d00b5feb59.png?width=600&height=323&rev=1.1||alt="12.PLC Protocol_html_387ec7d00b5feb59.png" height="323" width="600"]]
311 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_387ec7d00b5feb59.png?width=600&height=323&rev=1.1||alt="12.PLC Protocol_html_387ec7d00b5feb59.png" height="323" width="600"]]
246 246  
247 247  Click the [Apply] button to finish the setting.
248 248  
249 249  Click download and select the items as below, then click [execute] to download the configuration to PLC.
250 250  
251 -{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_cdef1c5ec8cc2105.png3Fwidth3D60026height3D43426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_cdef1c5ec8cc2105.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_cdef1c5ec8cc2105.png" height="434" width="600"]]
317 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_cdef1c5ec8cc2105.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_cdef1c5ec8cc2105.png" height="434" width="600"]]
252 252  
253 253   As soon as download is completed, connect PLC with serial port, then configure it in the [Specify Connection Destination Connection].
254 254  
255 255  Done.
256 256  
257 -**4)Configure the communication protocol**
323 +**Configure the communication protocol**
258 258  
259 259  {{id name="Iimage-20220825104904-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dbaddd53e9951a17.png||alt="image-20220825104904-1.png" height="1033" width="1920"]]
260 260  
261 -**5)Cable Wiring**
327 +**Cable Wiring**
262 262  
263 -* **RS422**
329 +**RS422**
264 264  
265 265  {{id name="Iimage-20220825105105-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d022c5ff4cf8c68e.png||alt="image-20220825105105-2.png" height="288" width="711"]]
266 266  
... ... @@ -342,11 +342,11 @@
342 342  
343 343  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
344 344  
345 -== {{id name="HL02Serial"/}}**L02 Serial ** ==
411 +== **L02 Serial ** ==
346 346  
347 347  Mitsubishi L02 series CPU built-in serial port.
348 348  
349 -**1)V-BOX Settings**
415 +**V-BOX Settings**
350 350  
351 351  |**Item**|**Settings**|**Note**
352 352  |Protocol|Mitsubishi L02|
... ... @@ -357,50 +357,52 @@
357 357  |Stop bit|1|
358 358  |PLC station No.|1~~255|Need to be the same as PLC settings
359 359  
360 -**2)Address List**
426 +**Address List**
361 361  
362 362  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
363 -|Bit|X|X|X h|0~~FFFF|
364 -|Bit|Y|Y|Y h|0~~FFFF|
365 -|Bit|M|M|M d|0~~9999|
366 -|Bit|L|L|L d|0~~9999|
367 -|Bit|F|F|F d|0~~9999|
368 -|Bit|B|B|B h|0~~FFFF|
369 -|Bit|V|V|V d|0~~2047|
370 -|Bit|TC|TC|TC d|0~~9999|
371 -|Bit|SS|SS|SS d|0~~9999|
372 -|Bit|SC|SC|SC d|0~~9999|
373 -|Bit|CS|CS|CS d|0~~9999|
374 -|Bit|CC|CC|CC d|0~~9999|
375 -|Bit|SB|SB|SB h|0~~FFFF|
376 -|Bit|SM|SM|SM d|0~~2047|
377 -|Bit|STS|STS|STS d|0~~1023|
378 -|Bit|S|S|S d|0~~9999|
379 -|Bit|DX|DX|DX h|0~~FFFF|
380 -|Bit|DY|DY|DY h|0~~FFFF|
381 -|Bit|TS|TS|TS d|0~~9999|
382 -|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15|
383 -|Word|W|W|W h|0~~FFFF|
384 -|Word|TN|TN|TN d|0~~99999|
385 -|Word|SN|SN|SN d|0~~99999|
386 -|Word|CN|CN|CN d|0~~99999|
387 -|Word|R|R|R d|0~~99999|
388 -|Word|SW|SW|SW h|0~~FFFF|
389 -|Word|Z|Z|Z d|0~~99999|
390 -|Word|ZR|ZR|ZR h|0~~FFFF|
391 -|Word|D|D|D d|0~~99999|
429 +|(% colspan="1" rowspan="20" %)Bit
430 + |X|X|X h|0~~FFFF|
431 +|Y|Y|Y h|0~~FFFF|
432 +|M|M|M d|0~~9999|
433 +|L|L|L d|0~~9999|
434 +|F|F|F d|0~~9999|
435 +|B|B|B h|0~~FFFF|
436 +|V|V|V d|0~~2047|
437 +|TC|TC|TC d|0~~9999|
438 +|SS|SS|SS d|0~~9999|
439 +|SC|SC|SC d|0~~9999|
440 +|CS|CS|CS d|0~~9999|
441 +|CC|CC|CC d|0~~9999|
442 +|SB|SB|SB h|0~~FFFF|
443 +|SM|SM|SM d|0~~2047|
444 +|STS|STS|STS d|0~~1023|
445 +|S|S|S d|0~~9999|
446 +|DX|DX|DX h|0~~FFFF|
447 +|DY|DY|DY h|0~~FFFF|
448 +|TS|TS|TS d|0~~9999|
449 +|Dbit|Dbit|Dbit d.d|0~~99999.0~~15|
450 +|(% colspan="1" rowspan="9" %)Word
451 + |W|W|W h|0~~FFFF|
452 +|TN|TN|TN d|0~~99999|
453 +|SN|SN|SN d|0~~99999|
454 +|CN|CN|CN d|0~~99999|
455 +|R|R|R d|0~~99999|
456 +|SW|SW|SW h|0~~FFFF|
457 +|Z|Z|Z d|0~~99999|
458 +|ZR|ZR|ZR h|0~~FFFF|
459 +|D|D|D d|0~~99999|
392 392  
393 -**3)Communication Settings**
461 +**Communication Settings**
394 394  
395 -{{id name="Iimage-20220825160648-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_cfed67f2ecb4ccec.png||alt="image-20220825160648-3.png" height="1009" width="1920"]]
463 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_cfed67f2ecb4ccec.png||alt="image-20220825160648-3.png" height="1009" width="1920"]]
396 396  
397 -**4)Cable Wiring**
465 +**Cable Wiring**
398 398  
399 -* **RS422**
467 +**RS422**
400 400  
401 -{{id name="Iimage-20220825161612-8.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_90e38f152d639809.png||alt="image-20220825161612-8.png" height="278" width="612"]]
469 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_90e38f152d639809.png||alt="image-20220825161612-8.png" height="278" width="612"]]
402 402  
403 -{{id name="Iimage-20220825160820-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d301e675d8224725.png||alt="image-20220825160820-4.png" height="208" width="359"]]
471 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d301e675d8224725.png||alt="image-20220825160820-4.png" height="208" width="359"]]
404 404  
405 405  == {{id name="HL02Ethernet"/}}**L02 Ethernet ** ==
406 406  
1.2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +58.0 KB
Content
1.5.1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +103.4 KB
Content
1.5.2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +46.6 KB
Content
1694743608503-875.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +98.4 KB
Content
xwiki_PIStudio_12.PLC+protocols_WebHome_1717efe8d969a43c.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +14.8 KB
Content
三菱 FN盒子通讯配置.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +65.5 KB
Content