Changes for page Mitsubishi
Last modified by Joe on 2024/05/21 10:53
From version 41.1
edited by Theodore Xu
on 2023/09/15 09:42
on 2023/09/15 09:42
Change comment:
There is no comment for this version
To version 43.1
edited by Theodore Xu
on 2023/09/15 10:10
on 2023/09/15 10:10
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 5 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -82,8 +82,32 @@ 82 82 83 83 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_4d2a4921240d23c6.png||alt="image-20220825102649-2.png" height="1009" width="1920"]] 84 84 85 -** 4)CableWiring**85 +**PLC Setting** 86 86 87 +Open GX Works2, create a new PLC project or open the project that has been created. 88 +Create new project: [Project]→[New]→[Series] FXCPU→[Type] FX3G/FX3GC→[OK]. 89 + 90 +(% style="text-align:center" %) 91 +[[image:1.2.png]] 92 + 93 +PLC Default Parameters: 94 +[Connection type]RS422;[Baud rate]9600, [Data bit]7, [Stop bit]1,[Parity]EVEN; [Station number]0 95 +Note:The serial port parameters should be set depending on field requirements 96 + 97 +PC and PLC connection: 98 + 99 +[All connection]→[Connection 1]→[Transfer Setup Connection1]→[Serial USB]→RS-232C: PC and PLC are connected by USB to RS232 adapter,choose corresponding [COM Port]COM 5 →[Transmission speed]9.6Kbps→[setup] →[Parity]EVEN→[Data bits]7→[Stop bits]1→[OK] 100 + 101 +(% style="text-align:center" %) 102 +[[image:1.5.1.png]] 103 + 104 +Connection test:when connection is OK,the GX Works2 prompts “Successfully connected with the FX3G/FX3GCCPU.” 105 + 106 +(% style="text-align:center" %) 107 +[[image:1.5.2.png]] 108 + 109 +**Cable Wiring** 110 + 87 87 **RS422** 88 88 89 89 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e904556bb758dfe.png||alt="image-20220825103421-5.png" height="296" width="715"]] ... ... @@ -90,6 +90,46 @@ 90 90 91 91 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_860bcf87f6ca7b98.png||alt="image-20220825100845-4.png" height="246" width="419"]] 92 92 117 +== **FX NOPROTOCOL** == 118 + 119 +Mitsubishi FX3G-RS232-BD 120 + 121 +**V-Box Settings** 122 + 123 +|=**Item**|=**Settings**|=**Note** 124 +|Protocol|Mitsubishi FX NOPROTOCOL| 125 +|Connection|RS232| 126 +|Baud rate|9600| 127 +|Data bit|7| 128 +|Parity|EVEN| 129 +|Stop bit|1| 130 +|PLC station No.|0| 131 + 132 +(% style="text-align:center" %) 133 +[[image:三菱 FN盒子通讯配置.png]] 134 + 135 +**Address List** 136 + 137 +|=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note** 138 +|(% rowspan="8" %)Bit|X|X|X o|0~~303237| 139 +|Y|Y|Y o|0~~303237| 140 +|M|M|M d|0~~99999| 141 +|T|T|T d|0~~99999| 142 +|C|C|C d|0~~99999| 143 +|S|S|S d|0~~99999| 144 +|SM|SM|SM d|8000~~9999| 145 +|Lamp|Lamp|Lamp d|0~~0| 146 +|(% rowspan="8" %)Word|X|X|X o|0~~303237| 147 +|Y|Y|Y o|0~~303237| 148 +|M|M|M d|0~~99999| 149 +|T|T|T d|0~~99999| 150 +|C|C|C d|0~~199| 151 +|D|D|D d|0~~7999| 152 +|S|S|S d|0~~99999| 153 +|SD|SD|SD d|8000~~9999| 154 + 155 +**Configure the communication protocol** 156 + 93 93 == **FX3U Ethernet ** == 94 94 95 95 Supported Modules: FX3U-ENET-ADP, FX3U-ENET-L
- 1.2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +58.0 KB - Content
- 1.5.1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +103.4 KB - Content
- 1.5.2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +46.6 KB - Content
- 1694743608503-875.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +98.4 KB - Content
- 三菱 FN盒子通讯配置.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +65.5 KB - Content