Changes for page Mitsubishi
Last modified by Joe on 2024/05/21 10:53
From version 41.1
edited by Theodore Xu
on 2023/09/15 09:42
on 2023/09/15 09:42
Change comment:
There is no comment for this version
To version 59.1
edited by Theodore Xu
on 2023/09/15 11:25
on 2023/09/15 11:25
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 12 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,11 +1,11 @@ 1 -== **FX 1S,1N,2NSerial ** ==1 +== **FX3U,3G,3GA Serial ** == 2 2 3 -Supported Series: Mitsubishi FX 1S, FX1N, FX2Nseries3 +Supported Series: Mitsubishi FX3U, FX3G, FX3GA series 4 4 5 5 **V-BOX Settings** 6 6 7 7 |**Item**|**Settings**|**Note** 8 -|Protocol|Mitsubishi FX 1S/FX1N/FX2N|8 +|Protocol|Mitsubishi FX3U/3G/3GA| 9 9 |Connection|RS422/RS485/RS232| 10 10 |Baud rate|9600~~115200| 11 11 |Data bit|7/8| ... ... @@ -13,9 +13,12 @@ 13 13 |Stop bit|1/2| 14 14 |PLC station No.|1~~255| 15 15 16 +(% style="text-align:center" %) 17 +[[image:三菱 FX3U 串口协议配置.png]] 18 + 16 16 **Address List** 17 17 18 -|**Type**|**Device registers**|** V-Boxregisters**|**Format**|**Range**|**Note**21 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 19 19 |(% rowspan="7" %)Bit|X|X|Xo|0~~303237| 20 20 |Y|Y|Y o|0~~303237| 21 21 |M|M|M d|0~~99999| ... ... @@ -32,37 +32,60 @@ 32 32 |S|S|S d|0~~99999| 33 33 |SD|SD|SD d|8000~~9999| 34 34 35 -**C onfigurethecommunicationprotocol**38 +**PLC Setting** 36 36 37 -{{id name="Iimage-20220825102844-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dc262f14b14cf564.png||alt="image-20220825102844-3.png" height="1011" width="1920"]] 40 +Open GX Works2, create a new PLC project or open the project that has been created. 41 +Create new project: [Project]→[New]→[Series] FXCPU→[Type] FX3G/FX3GC→[OK]. 38 38 43 +(% style="text-align:center" %) 44 +[[image:1.2.png]] 45 + 46 +PLC Default Parameters: 47 +[Connection type]RS422;[Baud rate]9600, [Data bit]7, [Stop bit]1,[Parity]EVEN; [Station number]0 48 +Note:The serial port parameters should be set depending on field requirements 49 + 50 +PC and PLC connection: 51 + 52 +[All connection]→[Connection 1]→[Transfer Setup Connection1]→[Serial USB]→RS-232C: PC and PLC are connected by USB to RS232 adapter,choose corresponding [COM Port]COM 5 →[Transmission speed]9.6Kbps→[setup] →[Parity]EVEN→[Data bits]7→[Stop bits]1→[OK] 53 + 54 +(% style="text-align:center" %) 55 +[[image:1.5.1.png]] 56 + 57 +Connection test:when connection is OK,the GX Works2 prompts “Successfully connected with the FX3G/FX3GCCPU.” 58 + 59 +(% style="text-align:center" %) 60 +[[image:1.5.2.png]] 61 + 39 39 **Cable Wiring** 40 40 41 41 **RS422** 42 42 43 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9 294a40c62eb99be.png||alt="image-20220825103350-4.png" height="284" width="723"]]66 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e904556bb758dfe.png||alt="image-20220825103421-5.png" height="296" width="715"]] 44 44 45 45 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_860bcf87f6ca7b98.png||alt="image-20220825100845-4.png" height="246" width="419"]] 46 46 47 -== **FX 3U,3G,3GASerial** ==70 +== **FX NOPROTOCOL** == 48 48 49 - Supported Series:Mitsubishi FX3U, FX3G, FX3GA series72 +Mitsubishi FX3G-RS232-BD 50 50 51 -**V-B OXSettings**74 +**V-Box Settings** 52 52 53 -|**Item**|**Settings**|**Note** 54 -|Protocol|Mitsubishi FX 3U/3G/3GA|55 -|Connection|RS 422/RS485/RS232|56 -|Baud rate|9600 ~~115200|57 -|Data bit|7 /8|58 -|Parity|EVEN /Odd/None|59 -|Stop bit|1 /2|60 -|PLC station No.| 1~~255|76 +|=**Item**|=**Settings**|=**Note** 77 +|Protocol|Mitsubishi FX NOPROTOCOL| 78 +|Connection|RS232| 79 +|Baud rate|9600| 80 +|Data bit|7| 81 +|Parity|EVEN| 82 +|Stop bit|1| 83 +|PLC station No.|0| 61 61 85 +(% style="text-align:center" %) 86 +[[image:三菱 FN盒子通讯配置.png]] 87 + 62 62 **Address List** 63 63 64 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 65 -|(% rowspan=" 7" %)Bit|X|X|Xo|0~~303237|90 +|=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note** 91 +|(% rowspan="8" %)Bit|X|X|X o|0~~303237| 66 66 |Y|Y|Y o|0~~303237| 67 67 |M|M|M d|0~~99999| 68 68 |T|T|T d|0~~99999| ... ... @@ -69,7 +69,8 @@ 69 69 |C|C|C d|0~~99999| 70 70 |S|S|S d|0~~99999| 71 71 |SM|SM|SM d|8000~~9999| 72 -|(% rowspan="8" %)Word|X|X|Xo|0~~303237| 98 +|Lamp|Lamp|Lamp d|0~~0| 99 +|(% rowspan="8" %)Word|X|X|X o|0~~303237| 73 73 |Y|Y|Y o|0~~303237| 74 74 |M|M|M d|0~~99999| 75 75 |T|T|T d|0~~99999| ... ... @@ -78,18 +78,10 @@ 78 78 |S|S|S d|0~~99999| 79 79 |SD|SD|SD d|8000~~9999| 80 80 81 -**C onfigurethe communicationprotocol**108 +**Cable Wiring** 82 82 83 -[[image:xwiki_ V-BOX_V-Net_Training_1+Communication_WebHome_4d2a4921240d23c6.png||alt="image-20220825102649-2.png" height="1009" width="1920"]]110 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_1717efe8d969a43c.png]] 84 84 85 -**4)Cable Wiring** 86 - 87 -**RS422** 88 - 89 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e904556bb758dfe.png||alt="image-20220825103421-5.png" height="296" width="715"]] 90 - 91 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_860bcf87f6ca7b98.png||alt="image-20220825100845-4.png" height="246" width="419"]] 92 - 93 93 == **FX3U Ethernet ** == 94 94 95 95 Supported Modules: FX3U-ENET-ADP, FX3U-ENET-L ... ... @@ -102,6 +102,8 @@ 102 102 |Port No.|5009|Must be the same as the PLC setting 103 103 |PLC station No.|0| 104 104 124 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b2cdc33b6eb92b67.png||alt="image-20221119101946-2.png" height="395" width="695"]] 125 + 105 105 **Address List** 106 106 107 107 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** ... ... @@ -181,15 +181,11 @@ 181 181 182 182 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7f29923ebcb670d1.png||alt="image-20221116111727-5.png" height="416" width="697"]] 183 183 184 -** Configurethecommunication protocol**205 +== **FX5U Serial ** == 185 185 186 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b2cdc33b6eb92b67.png||alt="image-20221119101946-2.png" height="395" width="695"]] 187 - 188 -== {{id name="HFX5USerial"/}}**FX5U Serial ** == 189 - 190 190 Mitsubishi FX5U series PLC 191 191 192 -** 1)V-BOX Settings**209 +**V-BOX Settings** 193 193 194 194 |**Item**|**Settings**|**Note** 195 195 |Protocol|Mitsubishi FX5U| ... ... @@ -200,8 +200,11 @@ 200 200 |Stop bit|1| 201 201 |PLC station No.|1~~255|Need to be the same as PLC settings 202 202 203 -**2)Address List** 220 +(% style="text-align:center" %) 221 +[[image:三菱 FX5U 串口协议配置.png]] 204 204 223 +**Address List** 224 + 205 205 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 206 206 |(% rowspan="15" %)Bit|X|X|X o|0~~303237| 207 207 |Y|Y|Y o|0~~303237| ... ... @@ -228,40 +228,36 @@ 228 228 |D|D|D d|0~~7999| 229 229 |SD|SD|SD d|0~~11999| 230 230 231 -** 3)PLC Settings (GX Works 3)**251 +**PLC Settings (GX Works 3)** 232 232 233 233 Create a blank FX5U project 234 234 235 235 Find the 485 serial port module in the system navigation bar and double click to enter the settings. 236 236 237 - {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_5c9cb13fac1e6c93.png3Fwidth3D20026height3D46226rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5c9cb13fac1e6c93.png?width=200&height=462&rev=1.1||alt="12.PLC Protocol_html_5c9cb13fac1e6c93.png" height="462" width="200"]]257 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5c9cb13fac1e6c93.png?width=200&height=462&rev=1.1||alt="12.PLC Protocol_html_5c9cb13fac1e6c93.png" height="462" width="200"]] 238 238 239 239 Select protocol in the setting item, and set parameters. 240 240 241 - {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_de942589ca070228.png3Fwidth3D60026height3D32426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_de942589ca070228.png?width=600&height=324&rev=1.1||alt="12.PLC Protocol_html_de942589ca070228.png" height="324" width="600"]]261 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_de942589ca070228.png?width=600&height=324&rev=1.1||alt="12.PLC Protocol_html_de942589ca070228.png" height="324" width="600"]] 242 242 243 243 Set station number, and [Message Pattern] (Pattern 1 or Pattern 4) 244 244 245 - {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_387ec7d00b5feb59.png3Fwidth3D60026height3D32326rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_387ec7d00b5feb59.png?width=600&height=323&rev=1.1||alt="12.PLC Protocol_html_387ec7d00b5feb59.png" height="323" width="600"]]265 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_387ec7d00b5feb59.png?width=600&height=323&rev=1.1||alt="12.PLC Protocol_html_387ec7d00b5feb59.png" height="323" width="600"]] 246 246 247 247 Click the [Apply] button to finish the setting. 248 248 249 249 Click download and select the items as below, then click [execute] to download the configuration to PLC. 250 250 251 - {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_cdef1c5ec8cc2105.png3Fwidth3D60026height3D43426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_cdef1c5ec8cc2105.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_cdef1c5ec8cc2105.png" height="434" width="600"]]271 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_cdef1c5ec8cc2105.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_cdef1c5ec8cc2105.png" height="434" width="600"]] 252 252 253 253 As soon as download is completed, connect PLC with serial port, then configure it in the [Specify Connection Destination Connection]. 254 254 255 255 Done. 256 256 257 -** 4)Configurethe communicationprotocol**277 +**Cable Wiring** 258 258 259 - {{id name="Iimage-20220825104904-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dbaddd53e9951a17.png||alt="image-20220825104904-1.png" height="1033" width="1920"]]279 +**RS422** 260 260 261 -**5)Cable Wiring** 262 - 263 -* **RS422** 264 - 265 265 {{id name="Iimage-20220825105105-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d022c5ff4cf8c68e.png||alt="image-20220825105105-2.png" height="288" width="711"]] 266 266 267 267 {{id name="Iimage-20220825105533-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50e173394c73f154.png||alt="image-20220825105533-3.png" height="246" width="420"]] ... ... @@ -270,7 +270,7 @@ 270 270 271 271 Mitsubishi FX5U series PLC 272 272 273 -** 1)V-BOX Settings**289 +**V-BOX Settings** 274 274 275 275 |**Items**|**Settings**|**Note** 276 276 |Protocol|Mitsubishi FX5U| ... ... @@ -278,8 +278,11 @@ 278 278 |Port No.|5002|Must be the same as the PLC setting 279 279 |PLC station No.|0| 280 280 281 -**2)Address List** 297 +(% style="text-align:center" %) 298 +[[image:三菱 FX5U 以太网协议配置.png]] 282 282 300 +**Address List** 301 + 283 283 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 284 284 |(% rowspan="15" %)Bit|X|X|X o|0~~303237| 285 285 |Y|Y|Y o|0~~303237| ... ... @@ -306,11 +306,11 @@ 306 306 |D|D|D d|0~~7999| 307 307 |SD|SD|SD d|0~~11999| 308 308 309 -** 3)PLC Settings (GX Works 3)**328 +**PLC Settings (GX Works 3)** 310 310 311 311 Find the [Ethernet port] in the navigation area. 312 312 313 - {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_8e8f85ace087346c.png3Fwidth3D30026height3D59326rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8e8f85ace087346c.png?width=300&height=593&rev=1.1||alt="12.PLC Protocol_html_8e8f85ace087346c.png" height="593" width="300"]]332 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8e8f85ace087346c.png?width=300&height=593&rev=1.1||alt="12.PLC Protocol_html_8e8f85ace087346c.png" height="593" width="300"]] 314 314 315 315 Select [Own Node Settings] in the [Setting Item List]; 316 316 ... ... @@ -318,7 +318,7 @@ 318 318 319 319 Click [Detailed Settings] into [Ethernet Configuration (Built-in Ethernet Port)] windows; 320 320 321 - {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_5d98495052c8c10e.png3Fwidth3D60026height3D33926rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5d98495052c8c10e.png?width=600&height=339&rev=1.1||alt="12.PLC Protocol_html_5d98495052c8c10e.png" height="339" width="600"]]340 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5d98495052c8c10e.png?width=600&height=339&rev=1.1||alt="12.PLC Protocol_html_5d98495052c8c10e.png" height="339" width="600"]] 322 322 323 323 Select [SLMP Connection Module] and add into host station as below picture shows; 324 324 ... ... @@ -326,27 +326,24 @@ 326 326 327 327 Click [Close with Reflecting the Setting] to save and close window; 328 328 329 - {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_14b489fdc6c6589d.png3Fwidth3D60026height3D35026rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_14b489fdc6c6589d.png?width=600&height=350&rev=1.1||alt="12.PLC Protocol_html_14b489fdc6c6589d.png" height="350" width="600"]]348 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_14b489fdc6c6589d.png?width=600&height=350&rev=1.1||alt="12.PLC Protocol_html_14b489fdc6c6589d.png" height="350" width="600"]] 330 330 331 331 Click [Apply] to completed Etherenet settings; 332 332 333 333 Switch to the [On line data operation] interface as below, check the item and click [Execute] to download. 334 334 335 - {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_c93025a968a8a9e7.png3Fwidth3D60026height3D43426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_c93025a968a8a9e7.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_c93025a968a8a9e7.png" height="434" width="600"]]354 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_c93025a968a8a9e7.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_c93025a968a8a9e7.png" height="434" width="600"]] 336 336 337 -**4)Configure the communication protocol** 338 338 339 - {{id name="Iimage-20220825112403-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_caa9bf4d8cc6de0f.png||alt="图片-20220825112403-1.png" height="1033"width="1920"]]357 +**Cable Wiring** 340 340 341 -**5)Cable Wiring** 342 - 343 343 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 344 344 345 -== {{id name="HL02Serial"/}}**L02 Serial ** ==361 +== **L02 Serial ** == 346 346 347 347 Mitsubishi L02 series CPU built-in serial port. 348 348 349 -** 1)V-BOX Settings**365 +**V-BOX Settings** 350 350 351 351 |**Item**|**Settings**|**Note** 352 352 |Protocol|Mitsubishi L02| ... ... @@ -357,56 +357,57 @@ 357 357 |Stop bit|1| 358 358 |PLC station No.|1~~255|Need to be the same as PLC settings 359 359 360 -**2)Address List** 376 +(% style="text-align:center" %) 377 +[[image:三菱 L02串口协议配置.png]] 361 361 379 +**Address List** 380 + 362 362 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 363 -|Bit|X|X|X h|0~~FFFF| 364 -|Bit|Y|Y|Y h|0~~FFFF| 365 -|Bit|M|M|M d|0~~9999| 366 -|Bit|L|L|L d|0~~9999| 367 -|Bit|F|F|F d|0~~9999| 368 -|Bit|B|B|B h|0~~FFFF| 369 -|Bit|V|V|V d|0~~2047| 370 -|Bit|TC|TC|TC d|0~~9999| 371 -|Bit|SS|SS|SS d|0~~9999| 372 -|Bit|SC|SC|SC d|0~~9999| 373 -|Bit|CS|CS|CS d|0~~9999| 374 -|Bit|CC|CC|CC d|0~~9999| 375 -|Bit|SB|SB|SB h|0~~FFFF| 376 -|Bit|SM|SM|SM d|0~~2047| 377 -|Bit|STS|STS|STS d|0~~1023| 378 -|Bit|S|S|S d|0~~9999| 379 -|Bit|DX|DX|DX h|0~~FFFF| 380 -|Bit|DY|DY|DY h|0~~FFFF| 381 -|Bit|TS|TS|TS d|0~~9999| 382 -|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15| 383 -|Word|W|W|W h|0~~FFFF| 384 -|Word|TN|TN|TN d|0~~99999| 385 -|Word|SN|SN|SN d|0~~99999| 386 -|Word|CN|CN|CN d|0~~99999| 387 -|Word|R|R|R d|0~~99999| 388 -|Word|SW|SW|SW h|0~~FFFF| 389 -|Word|Z|Z|Z d|0~~99999| 390 -|Word|ZR|ZR|ZR h|0~~FFFF| 391 -|Word|D|D|D d|0~~99999| 382 +|(% colspan="1" rowspan="20" %)Bit 383 + |X|X|X h|0~~FFFF| 384 +|Y|Y|Y h|0~~FFFF| 385 +|M|M|M d|0~~9999| 386 +|L|L|L d|0~~9999| 387 +|F|F|F d|0~~9999| 388 +|B|B|B h|0~~FFFF| 389 +|V|V|V d|0~~2047| 390 +|TC|TC|TC d|0~~9999| 391 +|SS|SS|SS d|0~~9999| 392 +|SC|SC|SC d|0~~9999| 393 +|CS|CS|CS d|0~~9999| 394 +|CC|CC|CC d|0~~9999| 395 +|SB|SB|SB h|0~~FFFF| 396 +|SM|SM|SM d|0~~2047| 397 +|STS|STS|STS d|0~~1023| 398 +|S|S|S d|0~~9999| 399 +|DX|DX|DX h|0~~FFFF| 400 +|DY|DY|DY h|0~~FFFF| 401 +|TS|TS|TS d|0~~9999| 402 +|Dbit|Dbit|Dbit d.d|0~~99999.0~~15| 403 +|(% colspan="1" rowspan="9" %)Word 404 + |W|W|W h|0~~FFFF| 405 +|TN|TN|TN d|0~~99999| 406 +|SN|SN|SN d|0~~99999| 407 +|CN|CN|CN d|0~~99999| 408 +|R|R|R d|0~~99999| 409 +|SW|SW|SW h|0~~FFFF| 410 +|Z|Z|Z d|0~~99999| 411 +|ZR|ZR|ZR h|0~~FFFF| 412 +|D|D|D d|0~~99999| 392 392 393 -** 3)Communication Settings**414 +**Cable Wiring** 394 394 395 - {{id name="Iimage-20220825160648-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_cfed67f2ecb4ccec.png||alt="image-20220825160648-3.png" height="1009" width="1920"]]416 +**RS422** 396 396 397 - **4)CableWiring**418 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_90e38f152d639809.png||alt="image-20220825161612-8.png" height="278" width="612"]] 398 398 399 - * **RS422**420 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d301e675d8224725.png||alt="image-20220825160820-4.png" height="208" width="359"]] 400 400 401 - {{id name="Iimage-20220825161612-8.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_90e38f152d639809.png||alt="image-20220825161612-8.png"height="278"width="612"]]422 +== **L02 Ethernet ** == 402 402 403 -{{id name="Iimage-20220825160820-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d301e675d8224725.png||alt="image-20220825160820-4.png" height="208" width="359"]] 404 - 405 -== {{id name="HL02Ethernet"/}}**L02 Ethernet ** == 406 - 407 407 Mitsubishi L series CPU built-in Ethernet port. 408 408 409 -** 1)V-BOX Settings**426 +**V-BOX Settings** 410 410 411 411 |**Items**|**Settings**|**Note** 412 412 |Protocol|MIT L02 CPU MELSEC| ... ... @@ -414,41 +414,11 @@ 414 414 |Port No.|1025|Must be the same as the PLC setting 415 415 |PLC station No.|0|Must be the same as the PLC setting 416 416 417 -**2)Address List** 434 +(% style="text-align:center" %) 435 +[[image:三菱 L02以太网协议配置1.png]] 418 418 419 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 420 -|Bit|X|X|X h|0~~FFFF| 421 -|Bit|Y|Y|Y h|0~~FFFF| 422 -|Bit|M|M|M d|0~~9999| 423 -|Bit|L|L|L d|0~~9999| 424 -|Bit|F|F|F d|0~~9999| 425 -|Bit|B|B|B h|0~~FFFF| 426 -|Bit|V|V|V d|0~~2047| 427 -|Bit|TC|TC|TC d|0~~9999| 428 -|Bit|SS|SS|SS d|0~~9999| 429 -|Bit|SC|SC|SC d|0~~9999| 430 -|Bit|CS|CS|CS d|0~~9999| 431 -|Bit|CC|CC|CC d|0~~9999| 432 -|Bit|SB|SB|SB h|0~~FFFF| 433 -|Bit|SM|SM|SM d|0~~2047| 434 -|Bit|STS|STS|STS d|0~~1023| 435 -|Bit|S|S|S d|0~~9999| 436 -|Bit|DX|DX|DX h|0~~FFFF| 437 -|Bit|DY|DY|DY h|0~~FFFF| 438 -|Bit|TS|TS|TS d|0~~9999| 439 -|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15| 440 -|Word|W|W|W h|0~~FFFF| 441 -|Word|TN|TN|TN d|0~~99999| 442 -|Word|SN|SN|SN d|0~~99999| 443 -|Word|CN|CN|CN d|0~~99999| 444 -|Word|R|R|R d|0~~99999| 445 -|Word|SW|SW|SW h|0~~FFFF| 446 -|Word|Z|Z|Z d|0~~99999| 447 -|Word|ZR|ZR|ZR h|0~~FFFF| 448 -|Word|D|D|D d|0~~99999| 437 +**PLC Settings (GX Works2 )** 449 449 450 -**3)PLC Settings (GX Works2 )** 451 - 452 452 Create a project 453 453 454 454 Set PLC IP, subnet mask and gateway; ... ... @@ -455,11 +455,11 @@ 455 455 456 456 Select [Binary Code] as communication data code; 457 457 458 - {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_776e17505f3fc6c0.png3Fwidth3D60026height3D52426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_776e17505f3fc6c0.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_776e17505f3fc6c0.png" height="524" width="600"]]445 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_776e17505f3fc6c0.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_776e17505f3fc6c0.png" height="524" width="600"]] 459 459 460 460 Set PLC port number, for example 1025 461 461 462 - {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_8d0d1a22d388f70b.png3Fwidth3D60026height3D52426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8d0d1a22d388f70b.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]]449 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8d0d1a22d388f70b.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]] 463 463 464 464 Save settings; 465 465 ... ... @@ -467,14 +467,10 @@ 467 467 468 468 Restart PLC device; 469 469 470 -** 4)Configurethe communicationprotocol**457 +**Cable Wiring** 471 471 472 - {{id name="Iimage-20220825142659-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_fafc9b29e20178c0.png||alt="image-20220825142659-1.png" height="1010" width="1920"]]459 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 473 473 474 -**5)Cable Wiring** 475 - 476 -{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1-1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 477 - 478 478 == {{id name="HQ12HSerial"/}}**Q12H Serial ** == 479 479 480 480 This Demo shows V-BOX communicate with Q12H PLC by Q02H serial Protocol ... ... @@ -485,7 +485,7 @@ 485 485 486 486 Mitsubishi QJ71E71 Ethernet communication module; 487 487 488 -** 1)V-BOX Settings**471 +**V-BOX Settings** 489 489 490 490 |**Items**|**Settings**|**Note** 491 491 |Protocol|MIT QJ71E71 MELSEC| ... ... @@ -493,8 +493,10 @@ 493 493 |Port No.|1025|Must be the same as the PLC setting 494 494 |PLC station No.|0|Must be the same as the PLC setting 495 495 496 - **2)AddressList**479 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50990385ef491b9e.png||alt="image-20221119171832-5.png" height="354" width="625"]] 497 497 481 +**Address List** 482 + 498 498 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 499 499 |(% rowspan="18" %)Bit|X|X|X h|0~~1FFF| 500 500 |Y|Y|Y h|0~~1FFF| ... ... @@ -525,16 +525,16 @@ 525 525 |Z|Z|Z d|0~~15| 526 526 |ZR|ZR|ZR h|0~~FE7FF| 527 527 528 -** 3)PLC Settings(GX Works2)**513 +**PLC Settings(GX Works2)** 529 529 530 530 * Click [Ethernet/CC IE/MELSECNET]; 531 531 * Please select [Ethernet] as network type; 532 532 * Set station I/O number according to situation (For example, 0020 means that the module is connected to PLC CPU in first order); 533 533 * Select [Online] as Mode; 534 -* {{id name="Iimage-20221119171343-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png||alt="image-20221119171343-2.png" height="341" width="587"]]519 +* [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png||alt="image-20221119171343-2.png" height="341" width="587"]] 535 535 * Click [Operation setting] to set IP; 536 536 * Select [Binary Code] as [Communication Data Code]; 537 -* {{id name="Iimage-20221119171436-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png||alt="image-20221119171436-3.png" height="354" width="588"]]522 +* [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png||alt="image-20221119171436-3.png" height="354" width="588"]] 538 538 * Click [Open setting] 539 539 * Set protocol: TCP; 540 540 * Set [unpassive] in [Open system]; ... ... @@ -547,10 +547,6 @@ 547 547 * {{id name="Iimage-20221119171611-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1d8e2f4fb7c72471.png||alt="image-20221119171611-4.png" height="354" width="588"]] 548 548 * Download project into PLC and restart it 549 549 550 -** 4)Configurethe communicationprotocol**535 +**Cable Wiring** 551 551 552 -{{id name="Iimage-20221119171832-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50990385ef491b9e.png||alt="image-20221119171832-5.png" height="354" width="625"]] 553 - 554 -**5)Cable Wiring** 555 - 556 556 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
- 1.2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +58.0 KB - Content
- 1.5.1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +103.4 KB - Content
- 1.5.2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +46.6 KB - Content
- 1694743608503-875.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +98.4 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_1717efe8d969a43c.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +14.8 KB - Content
- 三菱 FN盒子通讯配置.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +65.5 KB - Content
- 三菱 FX3U 串口协议配置.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +65.5 KB - Content
- 三菱 FX5U 串口协议配置.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +65.0 KB - Content
- 三菱 FX5U 以太网协议配置.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +64.2 KB - Content
- 三菱 L02 以太网盒子通讯配置.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +66.5 KB - Content
- 三菱 L02串口协议配置.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +64.4 KB - Content
- 三菱 L02以太网协议配置1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +66.7 KB - Content