... ... @@ -520,7 +520,7 @@
520 520  
521 521  Mitsubishi QJ71E71 Ethernet communication module;
522 522  
523 -**1)V-BOX Settings**
523 +**V-BOX Settings**
524 524  
525 525  |**Items**|**Settings**|**Note**
526 526  |Protocol|MIT QJ71E71 MELSEC|
... ... @@ -528,8 +528,10 @@
528 528  |Port No.|1025|Must be the same as the PLC setting
529 529  |PLC station No.|0|Must be the same as the PLC setting
530 530  
531 -**2)Address List**
531 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50990385ef491b9e.png||alt="image-20221119171832-5.png" height="354" width="625"]]
532 532  
533 +**Address List**
534 +
533 533  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
534 534  |(% rowspan="18" %)Bit|X|X|X h|0~~1FFF|
535 535  |Y|Y|Y h|0~~1FFF|
... ... @@ -560,16 +560,16 @@
560 560  |Z|Z|Z d|0~~15|
561 561  |ZR|ZR|ZR h|0~~FE7FF|
562 562  
563 -**3)PLC Settings(GX Works2)**
565 +**PLC Settings(GX Works2)**
564 564  
565 565  * Click [Ethernet/CC IE/MELSECNET];
566 566  * Please select [Ethernet] as network type;
567 567  * Set station I/O number according to situation (For example, 0020 means that the module is connected to PLC CPU in first order);
568 568  * Select [Online] as Mode;
569 -* {{id name="Iimage-20221119171343-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png||alt="image-20221119171343-2.png" height="341" width="587"]]
571 +* [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png||alt="image-20221119171343-2.png" height="341" width="587"]]
570 570  * Click [Operation setting] to set IP;
571 571  * Select [Binary Code] as [Communication Data Code];
572 -* {{id name="Iimage-20221119171436-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png||alt="image-20221119171436-3.png" height="354" width="588"]]
574 +* [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png||alt="image-20221119171436-3.png" height="354" width="588"]]
573 573  * Click [Open setting]
574 574  * Set protocol: TCP;
575 575  * Set [unpassive] in [Open system];
... ... @@ -582,10 +582,6 @@
582 582  * {{id name="Iimage-20221119171611-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1d8e2f4fb7c72471.png||alt="image-20221119171611-4.png" height="354" width="588"]]
583 583  * Download project into PLC and restart it
584 584  
585 -**4)Configure the communication protocol**
587 +**Cable Wiring**
586 586  
587 -{{id name="Iimage-20221119171832-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50990385ef491b9e.png||alt="image-20221119171832-5.png" height="354" width="625"]]
588 -