Changes for page Mitsubishi
Last modified by Joe on 2024/05/21 10:53
From version 49.1
edited by Theodore Xu
on 2023/09/15 10:41
on 2023/09/15 10:41
Change comment:
There is no comment for this version
To version 53.1
edited by Theodore Xu
on 2023/09/15 10:58
on 2023/09/15 10:58
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -423,6 +423,9 @@ 423 423 |Stop bit|1| 424 424 |PLC station No.|1~~255|Need to be the same as PLC settings 425 425 426 +(% style="text-align:center" %) 427 +[[image:三菱 L02串口协议配置.png]] 428 + 426 426 **Address List** 427 427 428 428 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** ... ... @@ -458,10 +458,6 @@ 458 458 |ZR|ZR|ZR h|0~~FFFF| 459 459 |D|D|D d|0~~99999| 460 460 461 -**Communication Settings** 462 - 463 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_cfed67f2ecb4ccec.png||alt="image-20220825160648-3.png" height="1009" width="1920"]] 464 - 465 465 **Cable Wiring** 466 466 467 467 **RS422** ... ... @@ -482,6 +482,9 @@ 482 482 |Port No.|1025|Must be the same as the PLC setting 483 483 |PLC station No.|0|Must be the same as the PLC setting 484 484 484 +(% style="text-align:center" %) 485 +[[image:三菱 L02以太网协议配置1.png]] 486 + 485 485 **PLC Settings (GX Works2 )** 486 486 487 487 Create a project ... ... @@ -502,10 +502,6 @@ 502 502 503 503 Restart PLC device; 504 504 505 -**Configure the communication protocol** 506 - 507 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_fafc9b29e20178c0.png||alt="image-20220825142659-1.png" height="1010" width="1920"]] 508 - 509 509 **Cable Wiring** 510 510 511 511 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] ... ... @@ -520,7 +520,7 @@ 520 520 521 521 Mitsubishi QJ71E71 Ethernet communication module; 522 522 523 -** 1)V-BOX Settings**521 +**V-BOX Settings** 524 524 525 525 |**Items**|**Settings**|**Note** 526 526 |Protocol|MIT QJ71E71 MELSEC| ... ... @@ -528,8 +528,10 @@ 528 528 |Port No.|1025|Must be the same as the PLC setting 529 529 |PLC station No.|0|Must be the same as the PLC setting 530 530 531 - **2)AddressList**529 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50990385ef491b9e.png||alt="image-20221119171832-5.png" height="354" width="625"]] 532 532 531 +**Address List** 532 + 533 533 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 534 534 |(% rowspan="18" %)Bit|X|X|X h|0~~1FFF| 535 535 |Y|Y|Y h|0~~1FFF| ... ... @@ -560,16 +560,16 @@ 560 560 |Z|Z|Z d|0~~15| 561 561 |ZR|ZR|ZR h|0~~FE7FF| 562 562 563 -** 3)PLC Settings(GX Works2)**563 +**PLC Settings(GX Works2)** 564 564 565 565 * Click [Ethernet/CC IE/MELSECNET]; 566 566 * Please select [Ethernet] as network type; 567 567 * Set station I/O number according to situation (For example, 0020 means that the module is connected to PLC CPU in first order); 568 568 * Select [Online] as Mode; 569 -* {{id name="Iimage-20221119171343-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png||alt="image-20221119171343-2.png" height="341" width="587"]]569 +* [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png||alt="image-20221119171343-2.png" height="341" width="587"]] 570 570 * Click [Operation setting] to set IP; 571 571 * Select [Binary Code] as [Communication Data Code]; 572 -* {{id name="Iimage-20221119171436-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png||alt="image-20221119171436-3.png" height="354" width="588"]]572 +* [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png||alt="image-20221119171436-3.png" height="354" width="588"]] 573 573 * Click [Open setting] 574 574 * Set protocol: TCP; 575 575 * Set [unpassive] in [Open system]; ... ... @@ -582,10 +582,6 @@ 582 582 * {{id name="Iimage-20221119171611-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1d8e2f4fb7c72471.png||alt="image-20221119171611-4.png" height="354" width="588"]] 583 583 * Download project into PLC and restart it 584 584 585 -** 4)Configurethe communicationprotocol**585 +**Cable Wiring** 586 586 587 -{{id name="Iimage-20221119171832-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50990385ef491b9e.png||alt="image-20221119171832-5.png" height="354" width="625"]] 588 - 589 -**5)Cable Wiring** 590 - 591 591 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
- 三菱 L02 以太网盒子通讯配置.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +66.5 KB - Content
- 三菱 L02串口协议配置.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +64.4 KB - Content
- 三菱 L02以太网协议配置1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +66.7 KB - Content