Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -482,6 +482,7 @@ 482 482 |Port No.|1025|Must be the same as the PLC setting 483 483 |PLC station No.|0|Must be the same as the PLC setting 484 484 485 + 485 485 **PLC Settings (GX Works2 )** 486 486 487 487 Create a project ... ... @@ -490,11 +490,11 @@ 490 490 491 491 Select [Binary Code] as communication data code; 492 492 493 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_776e17505f3fc6c0.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_776e17505f3fc6c0.png" height="524" width="600"]] 494 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_776e17505f3fc6c0.png3Fwidth3D60026height3D52426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_776e17505f3fc6c0.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_776e17505f3fc6c0.png" height="524" width="600"]] 494 494 495 495 Set PLC port number, for example 1025 496 496 497 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8d0d1a22d388f70b.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]] 498 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_8d0d1a22d388f70b.png3Fwidth3D60026height3D52426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8d0d1a22d388f70b.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]] 498 498 499 499 Save settings; 500 500 ... ... @@ -502,13 +502,13 @@ 502 502 503 503 Restart PLC device; 504 504 505 -**Configure the communication protocol** 506 +**4)Configure the communication protocol** 506 506 507 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_fafc9b29e20178c0.png||alt="image-20220825142659-1.png" height="1010" width="1920"]] 508 +{{id name="Iimage-20220825142659-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_fafc9b29e20178c0.png||alt="image-20220825142659-1.png" height="1010" width="1920"]] 508 508 509 -**Cable Wiring** 510 +**5)Cable Wiring** 510 510 511 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 512 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1-1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 512 512 513 513 == {{id name="HQ12HSerial"/}}**Q12H Serial ** == 514 514 ... ... @@ -520,7 +520,7 @@ 520 520 521 521 Mitsubishi QJ71E71 Ethernet communication module; 522 522 523 -**V-BOX Settings** 524 +**1)V-BOX Settings** 524 524 525 525 |**Items**|**Settings**|**Note** 526 526 |Protocol|MIT QJ71E71 MELSEC| ... ... @@ -528,10 +528,8 @@ 528 528 |Port No.|1025|Must be the same as the PLC setting 529 529 |PLC station No.|0|Must be the same as the PLC setting 530 530 531 - [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50990385ef491b9e.png||alt="image-20221119171832-5.png"height="354" width="625"]]532 +**2)Address List** 532 532 533 -**Address List** 534 - 535 535 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 536 536 |(% rowspan="18" %)Bit|X|X|X h|0~~1FFF| 537 537 |Y|Y|Y h|0~~1FFF| ... ... @@ -562,16 +562,16 @@ 562 562 |Z|Z|Z d|0~~15| 563 563 |ZR|ZR|ZR h|0~~FE7FF| 564 564 565 -**PLC Settings(GX Works2)** 564 +**3)PLC Settings(GX Works2)** 566 566 567 567 * Click [Ethernet/CC IE/MELSECNET]; 568 568 * Please select [Ethernet] as network type; 569 569 * Set station I/O number according to situation (For example, 0020 means that the module is connected to PLC CPU in first order); 570 570 * Select [Online] as Mode; 571 -* [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png||alt="image-20221119171343-2.png" height="341" width="587"]] 570 +* {{id name="Iimage-20221119171343-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png||alt="image-20221119171343-2.png" height="341" width="587"]] 572 572 * Click [Operation setting] to set IP; 573 573 * Select [Binary Code] as [Communication Data Code]; 574 -* [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png||alt="image-20221119171436-3.png" height="354" width="588"]] 573 +* {{id name="Iimage-20221119171436-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png||alt="image-20221119171436-3.png" height="354" width="588"]] 575 575 * Click [Open setting] 576 576 * Set protocol: TCP; 577 577 * Set [unpassive] in [Open system]; ... ... @@ -584,6 +584,10 @@ 584 584 * {{id name="Iimage-20221119171611-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1d8e2f4fb7c72471.png||alt="image-20221119171611-4.png" height="354" width="588"]] 585 585 * Download project into PLC and restart it 586 586 587 -**C ableWiring**586 +**4)Configure the communication protocol** 588 588 588 +{{id name="Iimage-20221119171832-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50990385ef491b9e.png||alt="image-20221119171832-5.png" height="354" width="625"]] 589 + 590 +**5)Cable Wiring** 591 + 589 589 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]