... ... @@ -520,7 +520,7 @@
520 520  
521 521  Mitsubishi QJ71E71 Ethernet communication module;
522 522  
523 -**V-BOX Settings**
523 +**1)V-BOX Settings**
524 524  
525 525  |**Items**|**Settings**|**Note**
526 526  |Protocol|MIT QJ71E71 MELSEC|
... ... @@ -528,10 +528,8 @@
528 528  |Port No.|1025|Must be the same as the PLC setting
529 529  |PLC station No.|0|Must be the same as the PLC setting
530 530  
531 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50990385ef491b9e.png||alt="image-20221119171832-5.png" height="354" width="625"]]
531 +**2)Address List**
532 532  
533 -**Address List**
534 -
535 535  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
536 536  |(% rowspan="18" %)Bit|X|X|X h|0~~1FFF|
537 537  |Y|Y|Y h|0~~1FFF|
... ... @@ -562,16 +562,16 @@
562 562  |Z|Z|Z d|0~~15|
563 563  |ZR|ZR|ZR h|0~~FE7FF|
564 564  
565 -**PLC Settings(GX Works2)**
563 +**3)PLC Settings(GX Works2)**
566 566  
567 567  * Click [Ethernet/CC IE/MELSECNET];
568 568  * Please select [Ethernet] as network type;
569 569  * Set station I/O number according to situation (For example, 0020 means that the module is connected to PLC CPU in first order);
570 570  * Select [Online] as Mode;
571 -* [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png||alt="image-20221119171343-2.png" height="341" width="587"]]
569 +* {{id name="Iimage-20221119171343-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png||alt="image-20221119171343-2.png" height="341" width="587"]]
572 572  * Click [Operation setting] to set IP;
573 573  * Select [Binary Code] as [Communication Data Code];
574 -* [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png||alt="image-20221119171436-3.png" height="354" width="588"]]
572 +* {{id name="Iimage-20221119171436-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png||alt="image-20221119171436-3.png" height="354" width="588"]]
575 575  * Click [Open setting]
576 576  * Set protocol: TCP;
577 577  * Set [unpassive] in [Open system];
... ... @@ -584,6 +584,10 @@
584 584  * {{id name="Iimage-20221119171611-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1d8e2f4fb7c72471.png||alt="image-20221119171611-4.png" height="354" width="588"]]
585 585  * Download project into PLC and restart it
586 586  
587 -**Cable Wiring**
585 +**4)Configure the communication protocol**
588 588  
587 +{{id name="Iimage-20221119171832-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50990385ef491b9e.png||alt="image-20221119171832-5.png" height="354" width="625"]]
588 +
589 +**5)Cable Wiring**
590 +
589 589  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]