Changes for page Mitsubishi
Last modified by Joe on 2024/05/21 10:53
From version 50.1
edited by Theodore Xu
on 2023/09/15 10:44
on 2023/09/15 10:44
Change comment:
There is no comment for this version
To version 49.1
edited by Theodore Xu
on 2023/09/15 10:41
on 2023/09/15 10:41
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -520,7 +520,7 @@ 520 520 521 521 Mitsubishi QJ71E71 Ethernet communication module; 522 522 523 -**V-BOX Settings** 523 +**1)V-BOX Settings** 524 524 525 525 |**Items**|**Settings**|**Note** 526 526 |Protocol|MIT QJ71E71 MELSEC| ... ... @@ -528,10 +528,8 @@ 528 528 |Port No.|1025|Must be the same as the PLC setting 529 529 |PLC station No.|0|Must be the same as the PLC setting 530 530 531 - [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50990385ef491b9e.png||alt="image-20221119171832-5.png"height="354" width="625"]]531 +**2)Address List** 532 532 533 -**Address List** 534 - 535 535 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 536 536 |(% rowspan="18" %)Bit|X|X|X h|0~~1FFF| 537 537 |Y|Y|Y h|0~~1FFF| ... ... @@ -562,16 +562,16 @@ 562 562 |Z|Z|Z d|0~~15| 563 563 |ZR|ZR|ZR h|0~~FE7FF| 564 564 565 -**PLC Settings(GX Works2)** 563 +**3)PLC Settings(GX Works2)** 566 566 567 567 * Click [Ethernet/CC IE/MELSECNET]; 568 568 * Please select [Ethernet] as network type; 569 569 * Set station I/O number according to situation (For example, 0020 means that the module is connected to PLC CPU in first order); 570 570 * Select [Online] as Mode; 571 -* [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png||alt="image-20221119171343-2.png" height="341" width="587"]] 569 +* {{id name="Iimage-20221119171343-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png||alt="image-20221119171343-2.png" height="341" width="587"]] 572 572 * Click [Operation setting] to set IP; 573 573 * Select [Binary Code] as [Communication Data Code]; 574 -* [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png||alt="image-20221119171436-3.png" height="354" width="588"]] 572 +* {{id name="Iimage-20221119171436-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png||alt="image-20221119171436-3.png" height="354" width="588"]] 575 575 * Click [Open setting] 576 576 * Set protocol: TCP; 577 577 * Set [unpassive] in [Open system]; ... ... @@ -584,6 +584,10 @@ 584 584 * {{id name="Iimage-20221119171611-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1d8e2f4fb7c72471.png||alt="image-20221119171611-4.png" height="354" width="588"]] 585 585 * Download project into PLC and restart it 586 586 587 -**C ableWiring**585 +**4)Configure the communication protocol** 588 588 587 +{{id name="Iimage-20221119171832-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50990385ef491b9e.png||alt="image-20221119171832-5.png" height="354" width="625"]] 588 + 589 +**5)Cable Wiring** 590 + 589 589 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]