Changes for page Mitsubishi

Last modified by Joe on 2024/05/21 10:53

From version 52.1
edited by Theodore Xu
on 2023/09/15 10:54
Change comment: There is no comment for this version
To version 47.1
edited by Theodore Xu
on 2023/09/15 10:37
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -470,11 +470,11 @@
470 470  
471 471  [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d301e675d8224725.png||alt="image-20220825160820-4.png" height="208" width="359"]]
472 472  
473 -== **L02 Ethernet ** ==
473 +== {{id name="HL02Ethernet"/}}**L02 Ethernet ** ==
474 474  
475 475  Mitsubishi L series CPU built-in Ethernet port.
476 476  
477 -**V-BOX Settings**
477 +**1)V-BOX Settings**
478 478  
479 479  |**Items**|**Settings**|**Note**
480 480  |Protocol|MIT L02 CPU MELSEC|
... ... @@ -482,11 +482,41 @@
482 482  |Port No.|1025|Must be the same as the PLC setting
483 483  |PLC station No.|0|Must be the same as the PLC setting
484 484  
485 -(% style="text-align:center" %)
486 -[[image:三菱 L02以太网协议配置1.png]]
485 +**2)Address List**
487 487  
488 -**PLC Settings (GX Works2 )**
487 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
488 +|Bit|X|X|X h|0~~FFFF|
489 +|Bit|Y|Y|Y h|0~~FFFF|
490 +|Bit|M|M|M d|0~~9999|
491 +|Bit|L|L|L d|0~~9999|
492 +|Bit|F|F|F d|0~~9999|
493 +|Bit|B|B|B h|0~~FFFF|
494 +|Bit|V|V|V d|0~~2047|
495 +|Bit|TC|TC|TC d|0~~9999|
496 +|Bit|SS|SS|SS d|0~~9999|
497 +|Bit|SC|SC|SC d|0~~9999|
498 +|Bit|CS|CS|CS d|0~~9999|
499 +|Bit|CC|CC|CC d|0~~9999|
500 +|Bit|SB|SB|SB h|0~~FFFF|
501 +|Bit|SM|SM|SM d|0~~2047|
502 +|Bit|STS|STS|STS d|0~~1023|
503 +|Bit|S|S|S d|0~~9999|
504 +|Bit|DX|DX|DX h|0~~FFFF|
505 +|Bit|DY|DY|DY h|0~~FFFF|
506 +|Bit|TS|TS|TS d|0~~9999|
507 +|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15|
508 +|Word|W|W|W h|0~~FFFF|
509 +|Word|TN|TN|TN d|0~~99999|
510 +|Word|SN|SN|SN d|0~~99999|
511 +|Word|CN|CN|CN d|0~~99999|
512 +|Word|R|R|R d|0~~99999|
513 +|Word|SW|SW|SW h|0~~FFFF|
514 +|Word|Z|Z|Z d|0~~99999|
515 +|Word|ZR|ZR|ZR h|0~~FFFF|
516 +|Word|D|D|D d|0~~99999|
489 489  
518 +**3)PLC Settings (GX Works2 )**
519 +
490 490  Create a project
491 491  
492 492  Set PLC IP, subnet mask and gateway;
... ... @@ -493,11 +493,11 @@
493 493  
494 494  Select [Binary Code] as communication data code;
495 495  
496 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_776e17505f3fc6c0.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_776e17505f3fc6c0.png" height="524" width="600"]]
526 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_776e17505f3fc6c0.png3Fwidth3D60026height3D52426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_776e17505f3fc6c0.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_776e17505f3fc6c0.png" height="524" width="600"]]
497 497  
498 498  Set PLC port number, for example 1025
499 499  
500 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8d0d1a22d388f70b.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]]
530 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_8d0d1a22d388f70b.png3Fwidth3D60026height3D52426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8d0d1a22d388f70b.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]]
501 501  
502 502  Save settings;
503 503  
... ... @@ -505,10 +505,14 @@
505 505  
506 506  Restart PLC device;
507 507  
508 -**Cable Wiring**
538 +**4)Configure the communication protocol**
509 509  
510 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
540 +{{id name="Iimage-20220825142659-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_fafc9b29e20178c0.png||alt="image-20220825142659-1.png" height="1010" width="1920"]]
511 511  
542 +**5)Cable Wiring**
543 +
544 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1-1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
545 +
512 512  == {{id name="HQ12HSerial"/}}**Q12H Serial ** ==
513 513  
514 514  This Demo shows V-BOX communicate with Q12H PLC by Q02H serial Protocol
... ... @@ -519,7 +519,7 @@
519 519  
520 520  Mitsubishi QJ71E71 Ethernet communication module;
521 521  
522 -**V-BOX Settings**
556 +**1)V-BOX Settings**
523 523  
524 524  |**Items**|**Settings**|**Note**
525 525  |Protocol|MIT QJ71E71 MELSEC|
... ... @@ -527,10 +527,8 @@
527 527  |Port No.|1025|Must be the same as the PLC setting
528 528  |PLC station No.|0|Must be the same as the PLC setting
529 529  
530 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50990385ef491b9e.png||alt="image-20221119171832-5.png" height="354" width="625"]]
564 +**2)Address List**
531 531  
532 -**Address List**
533 -
534 534  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
535 535  |(% rowspan="18" %)Bit|X|X|X h|0~~1FFF|
536 536  |Y|Y|Y h|0~~1FFF|
... ... @@ -561,16 +561,16 @@
561 561  |Z|Z|Z d|0~~15|
562 562  |ZR|ZR|ZR h|0~~FE7FF|
563 563  
564 -**PLC Settings(GX Works2)**
596 +**3)PLC Settings(GX Works2)**
565 565  
566 566  * Click [Ethernet/CC IE/MELSECNET];
567 567  * Please select [Ethernet] as network type;
568 568  * Set station I/O number according to situation (For example, 0020 means that the module is connected to PLC CPU in first order);
569 569  * Select [Online] as Mode;
570 -* [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png||alt="image-20221119171343-2.png" height="341" width="587"]]
602 +* {{id name="Iimage-20221119171343-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png||alt="image-20221119171343-2.png" height="341" width="587"]]
571 571  * Click [Operation setting] to set IP;
572 572  * Select [Binary Code] as [Communication Data Code];
573 -* [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png||alt="image-20221119171436-3.png" height="354" width="588"]]
605 +* {{id name="Iimage-20221119171436-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png||alt="image-20221119171436-3.png" height="354" width="588"]]
574 574  * Click [Open setting]
575 575  * Set protocol: TCP;
576 576  * Set [unpassive] in [Open system];
... ... @@ -583,6 +583,10 @@
583 583  * {{id name="Iimage-20221119171611-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1d8e2f4fb7c72471.png||alt="image-20221119171611-4.png" height="354" width="588"]]
584 584  * Download project into PLC and restart it
585 585  
586 -**Cable Wiring**
618 +**4)Configure the communication protocol**
587 587  
620 +{{id name="Iimage-20221119171832-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50990385ef491b9e.png||alt="image-20221119171832-5.png" height="354" width="625"]]
621 +
622 +**5)Cable Wiring**
623 +
588 588  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
三菱 L02 以太网盒子通讯配置.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -66.5 KB
Content
三菱 L02以太网协议配置1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -66.7 KB
Content