Changes for page Mitsubishi

Last modified by Joe on 2024/05/21 10:53

From version 53.1
edited by Theodore Xu
on 2023/09/15 10:58
Change comment: There is no comment for this version
To version 49.1
edited by Theodore Xu
on 2023/09/15 10:41
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -423,9 +423,6 @@
423 423  |Stop bit|1|
424 424  |PLC station No.|1~~255|Need to be the same as PLC settings
425 425  
426 -(% style="text-align:center" %)
427 -[[image:三菱 L02串口协议配置.png]]
428 -
429 429  **Address List**
430 430  
431 431  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
... ... @@ -461,6 +461,10 @@
461 461  |ZR|ZR|ZR h|0~~FFFF|
462 462  |D|D|D d|0~~99999|
463 463  
461 +**Communication Settings**
462 +
463 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_cfed67f2ecb4ccec.png||alt="image-20220825160648-3.png" height="1009" width="1920"]]
464 +
464 464  **Cable Wiring**
465 465  
466 466  **RS422**
... ... @@ -481,9 +481,6 @@
481 481  |Port No.|1025|Must be the same as the PLC setting
482 482  |PLC station No.|0|Must be the same as the PLC setting
483 483  
484 -(% style="text-align:center" %)
485 -[[image:三菱 L02以太网协议配置1.png]]
486 -
487 487  **PLC Settings (GX Works2 )**
488 488  
489 489  Create a project
... ... @@ -504,6 +504,10 @@
504 504  
505 505  Restart PLC device;
506 506  
505 +**Configure the communication protocol**
506 +
507 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_fafc9b29e20178c0.png||alt="image-20220825142659-1.png" height="1010" width="1920"]]
508 +
507 507  **Cable Wiring**
508 508  
509 509  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
... ... @@ -518,7 +518,7 @@
518 518  
519 519  Mitsubishi QJ71E71 Ethernet communication module;
520 520  
521 -**V-BOX Settings**
523 +**1)V-BOX Settings**
522 522  
523 523  |**Items**|**Settings**|**Note**
524 524  |Protocol|MIT QJ71E71 MELSEC|
... ... @@ -526,10 +526,8 @@
526 526  |Port No.|1025|Must be the same as the PLC setting
527 527  |PLC station No.|0|Must be the same as the PLC setting
528 528  
529 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50990385ef491b9e.png||alt="image-20221119171832-5.png" height="354" width="625"]]
531 +**2)Address List**
530 530  
531 -**Address List**
532 -
533 533  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
534 534  |(% rowspan="18" %)Bit|X|X|X h|0~~1FFF|
535 535  |Y|Y|Y h|0~~1FFF|
... ... @@ -560,16 +560,16 @@
560 560  |Z|Z|Z d|0~~15|
561 561  |ZR|ZR|ZR h|0~~FE7FF|
562 562  
563 -**PLC Settings(GX Works2)**
563 +**3)PLC Settings(GX Works2)**
564 564  
565 565  * Click [Ethernet/CC IE/MELSECNET];
566 566  * Please select [Ethernet] as network type;
567 567  * Set station I/O number according to situation (For example, 0020 means that the module is connected to PLC CPU in first order);
568 568  * Select [Online] as Mode;
569 -* [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png||alt="image-20221119171343-2.png" height="341" width="587"]]
569 +* {{id name="Iimage-20221119171343-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png||alt="image-20221119171343-2.png" height="341" width="587"]]
570 570  * Click [Operation setting] to set IP;
571 571  * Select [Binary Code] as [Communication Data Code];
572 -* [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png||alt="image-20221119171436-3.png" height="354" width="588"]]
572 +* {{id name="Iimage-20221119171436-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png||alt="image-20221119171436-3.png" height="354" width="588"]]
573 573  * Click [Open setting]
574 574  * Set protocol: TCP;
575 575  * Set [unpassive] in [Open system];
... ... @@ -582,6 +582,10 @@
582 582  * {{id name="Iimage-20221119171611-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1d8e2f4fb7c72471.png||alt="image-20221119171611-4.png" height="354" width="588"]]
583 583  * Download project into PLC and restart it
584 584  
585 -**Cable Wiring**
585 +**4)Configure the communication protocol**
586 586  
587 +{{id name="Iimage-20221119171832-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50990385ef491b9e.png||alt="image-20221119171832-5.png" height="354" width="625"]]
588 +
589 +**5)Cable Wiring**
590 +
587 587  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
三菱 L02 以太网盒子通讯配置.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -66.5 KB
Content
三菱 L02串口协议配置.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -64.4 KB
Content
三菱 L02以太网协议配置1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -66.7 KB
Content