Changes for page Mitsubishi
Last modified by Joe on 2024/05/21 10:53
From version 53.1
edited by Theodore Xu
on 2023/09/15 10:58
on 2023/09/15 10:58
Change comment:
There is no comment for this version
To version 59.1
edited by Theodore Xu
on 2023/09/15 11:25
on 2023/09/15 11:25
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,49 +47,3 @@ 1 -== **FX1S,1N,2N Serial ** == 2 - 3 -Supported Series: Mitsubishi FX1S, FX1N, FX2N series 4 - 5 -**V-BOX Settings** 6 - 7 -|**Item**|**Settings**|**Note** 8 -|Protocol|Mitsubishi FX1S/FX1N/FX2N| 9 -|Connection|RS422/RS485/RS232| 10 -|Baud rate|9600~~115200| 11 -|Data bit|7/8| 12 -|Parity|EVEN/Odd/None| 13 -|Stop bit|1/2| 14 -|PLC station No.|1~~255| 15 - 16 -**Address List** 17 - 18 -|**Type**|**Device registers**|**V-Box registers**|**Format**|**Range**|**Note** 19 -|(% rowspan="7" %)Bit|X|X|Xo|0~~303237| 20 -|Y|Y|Y o|0~~303237| 21 -|M|M|M d|0~~99999| 22 -|T|T|T d|0~~99999| 23 -|C|C|C d|0~~99999| 24 -|S|S|S d|0~~99999| 25 -|SM|SM|SM d|8000~~9999| 26 -|(% rowspan="8" %)Word|X|X|Xo|0~~303237| 27 -|Y|Y|Y o|0~~303237| 28 -|M|M|M d|0~~99999| 29 -|T|T|T d|0~~99999| 30 -|C|C|C d|0~~199| 31 -|D|D|D d|0~~7999| 32 -|S|S|S d|0~~99999| 33 -|SD|SD|SD d|8000~~9999| 34 - 35 -**Configure the communication protocol** 36 - 37 -{{id name="Iimage-20220825102844-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dc262f14b14cf564.png||alt="image-20220825102844-3.png" height="1011" width="1920"]] 38 - 39 -**Cable Wiring** 40 - 41 -**RS422** 42 - 43 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9294a40c62eb99be.png||alt="image-20220825103350-4.png" height="284" width="723"]] 44 - 45 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_860bcf87f6ca7b98.png||alt="image-20220825100845-4.png" height="246" width="419"]] 46 - 47 47 == **FX3U,3G,3GA Serial ** == 48 48 49 49 Supported Series: Mitsubishi FX3U, FX3G, FX3GA series ... ... @@ -59,6 +59,9 @@ 59 59 |Stop bit|1/2| 60 60 |PLC station No.|1~~255| 61 61 16 +(% style="text-align:center" %) 17 +[[image:三菱 FX3U 串口协议配置.png]] 18 + 62 62 **Address List** 63 63 64 64 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** ... ... @@ -78,10 +78,6 @@ 78 78 |S|S|S d|0~~99999| 79 79 |SD|SD|SD d|8000~~9999| 80 80 81 -**Configure the communication protocol** 82 - 83 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_4d2a4921240d23c6.png||alt="image-20220825102649-2.png" height="1009" width="1920"]] 84 - 85 85 **PLC Setting** 86 86 87 87 Open GX Works2, create a new PLC project or open the project that has been created. ... ... @@ -168,6 +168,8 @@ 168 168 |Port No.|5009|Must be the same as the PLC setting 169 169 |PLC station No.|0| 170 170 124 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b2cdc33b6eb92b67.png||alt="image-20221119101946-2.png" height="395" width="695"]] 125 + 171 171 **Address List** 172 172 173 173 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** ... ... @@ -247,10 +247,6 @@ 247 247 248 248 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7f29923ebcb670d1.png||alt="image-20221116111727-5.png" height="416" width="697"]] 249 249 250 -**Configure the communication protocol** 251 - 252 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b2cdc33b6eb92b67.png||alt="image-20221119101946-2.png" height="395" width="695"]] 253 - 254 254 == **FX5U Serial ** == 255 255 256 256 Mitsubishi FX5U series PLC ... ... @@ -266,6 +266,9 @@ 266 266 |Stop bit|1| 267 267 |PLC station No.|1~~255|Need to be the same as PLC settings 268 268 220 +(% style="text-align:center" %) 221 +[[image:三菱 FX5U 串口协议配置.png]] 222 + 269 269 **Address List** 270 270 271 271 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** ... ... @@ -320,10 +320,6 @@ 320 320 321 321 Done. 322 322 323 -**Configure the communication protocol** 324 - 325 -{{id name="Iimage-20220825104904-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dbaddd53e9951a17.png||alt="image-20220825104904-1.png" height="1033" width="1920"]] 326 - 327 327 **Cable Wiring** 328 328 329 329 **RS422** ... ... @@ -336,7 +336,7 @@ 336 336 337 337 Mitsubishi FX5U series PLC 338 338 339 -** 1)V-BOX Settings**289 +**V-BOX Settings** 340 340 341 341 |**Items**|**Settings**|**Note** 342 342 |Protocol|Mitsubishi FX5U| ... ... @@ -344,8 +344,11 @@ 344 344 |Port No.|5002|Must be the same as the PLC setting 345 345 |PLC station No.|0| 346 346 347 -**2)Address List** 297 +(% style="text-align:center" %) 298 +[[image:三菱 FX5U 以太网协议配置.png]] 348 348 300 +**Address List** 301 + 349 349 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 350 350 |(% rowspan="15" %)Bit|X|X|X o|0~~303237| 351 351 |Y|Y|Y o|0~~303237| ... ... @@ -372,11 +372,11 @@ 372 372 |D|D|D d|0~~7999| 373 373 |SD|SD|SD d|0~~11999| 374 374 375 -** 3)PLC Settings (GX Works 3)**328 +**PLC Settings (GX Works 3)** 376 376 377 377 Find the [Ethernet port] in the navigation area. 378 378 379 - {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_8e8f85ace087346c.png3Fwidth3D30026height3D59326rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8e8f85ace087346c.png?width=300&height=593&rev=1.1||alt="12.PLC Protocol_html_8e8f85ace087346c.png" height="593" width="300"]]332 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8e8f85ace087346c.png?width=300&height=593&rev=1.1||alt="12.PLC Protocol_html_8e8f85ace087346c.png" height="593" width="300"]] 380 380 381 381 Select [Own Node Settings] in the [Setting Item List]; 382 382 ... ... @@ -384,7 +384,7 @@ 384 384 385 385 Click [Detailed Settings] into [Ethernet Configuration (Built-in Ethernet Port)] windows; 386 386 387 - {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_5d98495052c8c10e.png3Fwidth3D60026height3D33926rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5d98495052c8c10e.png?width=600&height=339&rev=1.1||alt="12.PLC Protocol_html_5d98495052c8c10e.png" height="339" width="600"]]340 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5d98495052c8c10e.png?width=600&height=339&rev=1.1||alt="12.PLC Protocol_html_5d98495052c8c10e.png" height="339" width="600"]] 388 388 389 389 Select [SLMP Connection Module] and add into host station as below picture shows; 390 390 ... ... @@ -392,20 +392,17 @@ 392 392 393 393 Click [Close with Reflecting the Setting] to save and close window; 394 394 395 - {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_14b489fdc6c6589d.png3Fwidth3D60026height3D35026rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_14b489fdc6c6589d.png?width=600&height=350&rev=1.1||alt="12.PLC Protocol_html_14b489fdc6c6589d.png" height="350" width="600"]]348 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_14b489fdc6c6589d.png?width=600&height=350&rev=1.1||alt="12.PLC Protocol_html_14b489fdc6c6589d.png" height="350" width="600"]] 396 396 397 397 Click [Apply] to completed Etherenet settings; 398 398 399 399 Switch to the [On line data operation] interface as below, check the item and click [Execute] to download. 400 400 401 - {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_c93025a968a8a9e7.png3Fwidth3D60026height3D43426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_c93025a968a8a9e7.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_c93025a968a8a9e7.png" height="434" width="600"]]354 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_c93025a968a8a9e7.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_c93025a968a8a9e7.png" height="434" width="600"]] 402 402 403 -**4)Configure the communication protocol** 404 404 405 - {{id name="Iimage-20220825112403-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_caa9bf4d8cc6de0f.png||alt="图片-20220825112403-1.png" height="1033"width="1920"]]357 +**Cable Wiring** 406 406 407 -**5)Cable Wiring** 408 - 409 409 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 410 410 411 411 == **L02 Serial ** ==
- 三菱 FX3U 串口协议配置.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +65.5 KB - Content
- 三菱 FX5U 串口协议配置.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +65.0 KB - Content
- 三菱 FX5U 以太网协议配置.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +64.2 KB - Content