Changes for page Mitsubishi

Last modified by Joe on 2024/05/21 10:53

From version 54.1
edited by Theodore Xu
on 2023/09/15 11:07
Change comment: There is no comment for this version
To version 47.1
edited by Theodore Xu
on 2023/09/15 10:37
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -266,9 +266,6 @@
266 266  |Stop bit|1|
267 267  |PLC station No.|1~~255|Need to be the same as PLC settings
268 268  
269 -(% style="text-align:center" %)
270 -[[image:三菱 FX5U 串口协议配置.png]]
271 -
272 272  **Address List**
273 273  
274 274  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
... ... @@ -323,6 +323,10 @@
323 323  
324 324  Done.
325 325  
323 +**Configure the communication protocol**
324 +
325 +{{id name="Iimage-20220825104904-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dbaddd53e9951a17.png||alt="image-20220825104904-1.png" height="1033" width="1920"]]
326 +
326 326  **Cable Wiring**
327 327  
328 328  **RS422**
... ... @@ -422,9 +422,6 @@
422 422  |Stop bit|1|
423 423  |PLC station No.|1~~255|Need to be the same as PLC settings
424 424  
425 -(% style="text-align:center" %)
426 -[[image:三菱 L02串口协议配置.png]]
427 -
428 428  **Address List**
429 429  
430 430  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
... ... @@ -460,6 +460,10 @@
460 460  |ZR|ZR|ZR h|0~~FFFF|
461 461  |D|D|D d|0~~99999|
462 462  
461 +**Communication Settings**
462 +
463 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_cfed67f2ecb4ccec.png||alt="image-20220825160648-3.png" height="1009" width="1920"]]
464 +
463 463  **Cable Wiring**
464 464  
465 465  **RS422**
... ... @@ -468,11 +468,11 @@
468 468  
469 469  [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d301e675d8224725.png||alt="image-20220825160820-4.png" height="208" width="359"]]
470 470  
471 -== **L02 Ethernet ** ==
473 +== {{id name="HL02Ethernet"/}}**L02 Ethernet ** ==
472 472  
473 473  Mitsubishi L series CPU built-in Ethernet port.
474 474  
475 -**V-BOX Settings**
477 +**1)V-BOX Settings**
476 476  
477 477  |**Items**|**Settings**|**Note**
478 478  |Protocol|MIT L02 CPU MELSEC|
... ... @@ -480,11 +480,41 @@
480 480  |Port No.|1025|Must be the same as the PLC setting
481 481  |PLC station No.|0|Must be the same as the PLC setting
482 482  
483 -(% style="text-align:center" %)
484 -[[image:三菱 L02以太网协议配置1.png]]
485 +**2)Address List**
485 485  
486 -**PLC Settings (GX Works2 )**
487 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
488 +|Bit|X|X|X h|0~~FFFF|
489 +|Bit|Y|Y|Y h|0~~FFFF|
490 +|Bit|M|M|M d|0~~9999|
491 +|Bit|L|L|L d|0~~9999|
492 +|Bit|F|F|F d|0~~9999|
493 +|Bit|B|B|B h|0~~FFFF|
494 +|Bit|V|V|V d|0~~2047|
495 +|Bit|TC|TC|TC d|0~~9999|
496 +|Bit|SS|SS|SS d|0~~9999|
497 +|Bit|SC|SC|SC d|0~~9999|
498 +|Bit|CS|CS|CS d|0~~9999|
499 +|Bit|CC|CC|CC d|0~~9999|
500 +|Bit|SB|SB|SB h|0~~FFFF|
501 +|Bit|SM|SM|SM d|0~~2047|
502 +|Bit|STS|STS|STS d|0~~1023|
503 +|Bit|S|S|S d|0~~9999|
504 +|Bit|DX|DX|DX h|0~~FFFF|
505 +|Bit|DY|DY|DY h|0~~FFFF|
506 +|Bit|TS|TS|TS d|0~~9999|
507 +|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15|
508 +|Word|W|W|W h|0~~FFFF|
509 +|Word|TN|TN|TN d|0~~99999|
510 +|Word|SN|SN|SN d|0~~99999|
511 +|Word|CN|CN|CN d|0~~99999|
512 +|Word|R|R|R d|0~~99999|
513 +|Word|SW|SW|SW h|0~~FFFF|
514 +|Word|Z|Z|Z d|0~~99999|
515 +|Word|ZR|ZR|ZR h|0~~FFFF|
516 +|Word|D|D|D d|0~~99999|
487 487  
518 +**3)PLC Settings (GX Works2 )**
519 +
488 488  Create a project
489 489  
490 490  Set PLC IP, subnet mask and gateway;
... ... @@ -491,11 +491,11 @@
491 491  
492 492  Select [Binary Code] as communication data code;
493 493  
494 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_776e17505f3fc6c0.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_776e17505f3fc6c0.png" height="524" width="600"]]
526 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_776e17505f3fc6c0.png3Fwidth3D60026height3D52426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_776e17505f3fc6c0.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_776e17505f3fc6c0.png" height="524" width="600"]]
495 495  
496 496  Set PLC port number, for example 1025
497 497  
498 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8d0d1a22d388f70b.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]]
530 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_8d0d1a22d388f70b.png3Fwidth3D60026height3D52426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8d0d1a22d388f70b.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]]
499 499  
500 500  Save settings;
501 501  
... ... @@ -503,10 +503,14 @@
503 503  
504 504  Restart PLC device;
505 505  
506 -**Cable Wiring**
538 +**4)Configure the communication protocol**
507 507  
508 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
540 +{{id name="Iimage-20220825142659-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_fafc9b29e20178c0.png||alt="image-20220825142659-1.png" height="1010" width="1920"]]
509 509  
542 +**5)Cable Wiring**
543 +
544 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1-1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
545 +
510 510  == {{id name="HQ12HSerial"/}}**Q12H Serial ** ==
511 511  
512 512  This Demo shows V-BOX communicate with Q12H PLC by Q02H serial Protocol
... ... @@ -517,7 +517,7 @@
517 517  
518 518  Mitsubishi QJ71E71 Ethernet communication module;
519 519  
520 -**V-BOX Settings**
556 +**1)V-BOX Settings**
521 521  
522 522  |**Items**|**Settings**|**Note**
523 523  |Protocol|MIT QJ71E71 MELSEC|
... ... @@ -525,10 +525,8 @@
525 525  |Port No.|1025|Must be the same as the PLC setting
526 526  |PLC station No.|0|Must be the same as the PLC setting
527 527  
528 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50990385ef491b9e.png||alt="image-20221119171832-5.png" height="354" width="625"]]
564 +**2)Address List**
529 529  
530 -**Address List**
531 -
532 532  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
533 533  |(% rowspan="18" %)Bit|X|X|X h|0~~1FFF|
534 534  |Y|Y|Y h|0~~1FFF|
... ... @@ -559,16 +559,16 @@
559 559  |Z|Z|Z d|0~~15|
560 560  |ZR|ZR|ZR h|0~~FE7FF|
561 561  
562 -**PLC Settings(GX Works2)**
596 +**3)PLC Settings(GX Works2)**
563 563  
564 564  * Click [Ethernet/CC IE/MELSECNET];
565 565  * Please select [Ethernet] as network type;
566 566  * Set station I/O number according to situation (For example, 0020 means that the module is connected to PLC CPU in first order);
567 567  * Select [Online] as Mode;
568 -* [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png||alt="image-20221119171343-2.png" height="341" width="587"]]
602 +* {{id name="Iimage-20221119171343-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png||alt="image-20221119171343-2.png" height="341" width="587"]]
569 569  * Click [Operation setting] to set IP;
570 570  * Select [Binary Code] as [Communication Data Code];
571 -* [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png||alt="image-20221119171436-3.png" height="354" width="588"]]
605 +* {{id name="Iimage-20221119171436-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png||alt="image-20221119171436-3.png" height="354" width="588"]]
572 572  * Click [Open setting]
573 573  * Set protocol: TCP;
574 574  * Set [unpassive] in [Open system];
... ... @@ -581,6 +581,10 @@
581 581  * {{id name="Iimage-20221119171611-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1d8e2f4fb7c72471.png||alt="image-20221119171611-4.png" height="354" width="588"]]
582 582  * Download project into PLC and restart it
583 583  
584 -**Cable Wiring**
618 +**4)Configure the communication protocol**
585 585  
620 +{{id name="Iimage-20221119171832-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50990385ef491b9e.png||alt="image-20221119171832-5.png" height="354" width="625"]]
621 +
622 +**5)Cable Wiring**
623 +
586 586  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
三菱 FX5U 串口协议配置.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -65.0 KB
Content
三菱 L02 以太网盒子通讯配置.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -66.5 KB
Content
三菱 L02串口协议配置.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -64.4 KB
Content
三菱 L02以太网协议配置1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -66.7 KB
Content