Changes for page Mitsubishi
Last modified by Joe on 2024/05/21 10:53
From version 55.1
edited by Theodore Xu
on 2023/09/15 11:10
on 2023/09/15 11:10
Change comment:
There is no comment for this version
To version 40.1
edited by Theodore Xu
on 2023/09/15 09:39
on 2023/09/15 09:39
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 10 removed)
Details
- Page properties
-
- Content
-
... ... @@ -13,8 +13,6 @@ 13 13 |Stop bit|1/2| 14 14 |PLC station No.|1~~255| 15 15 16 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dc262f14b14cf564.png||alt="image-20220825102844-3.png" height="1011" width="1920"]] 17 - 18 18 **Address List** 19 19 20 20 |**Type**|**Device registers**|**V-Box registers**|**Format**|**Range**|**Note** ... ... @@ -34,6 +34,10 @@ 34 34 |S|S|S d|0~~99999| 35 35 |SD|SD|SD d|8000~~9999| 36 36 35 +**Configure the communication protocol** 36 + 37 +{{id name="Iimage-20220825102844-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dc262f14b14cf564.png||alt="image-20220825102844-3.png" height="1011" width="1920"]] 38 + 37 37 **Cable Wiring** 38 38 39 39 **RS422** ... ... @@ -80,32 +80,8 @@ 80 80 81 81 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_4d2a4921240d23c6.png||alt="image-20220825102649-2.png" height="1009" width="1920"]] 82 82 83 -** PLCSetting**85 +**4)Cable Wiring** 84 84 85 -Open GX Works2, create a new PLC project or open the project that has been created. 86 -Create new project: [Project]→[New]→[Series] FXCPU→[Type] FX3G/FX3GC→[OK]. 87 - 88 -(% style="text-align:center" %) 89 -[[image:1.2.png]] 90 - 91 -PLC Default Parameters: 92 -[Connection type]RS422;[Baud rate]9600, [Data bit]7, [Stop bit]1,[Parity]EVEN; [Station number]0 93 -Note:The serial port parameters should be set depending on field requirements 94 - 95 -PC and PLC connection: 96 - 97 -[All connection]→[Connection 1]→[Transfer Setup Connection1]→[Serial USB]→RS-232C: PC and PLC are connected by USB to RS232 adapter,choose corresponding [COM Port]COM 5 →[Transmission speed]9.6Kbps→[setup] →[Parity]EVEN→[Data bits]7→[Stop bits]1→[OK] 98 - 99 -(% style="text-align:center" %) 100 -[[image:1.5.1.png]] 101 - 102 -Connection test:when connection is OK,the GX Works2 prompts “Successfully connected with the FX3G/FX3GCCPU.” 103 - 104 -(% style="text-align:center" %) 105 -[[image:1.5.2.png]] 106 - 107 -**Cable Wiring** 108 - 109 109 **RS422** 110 110 111 111 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e904556bb758dfe.png||alt="image-20220825103421-5.png" height="296" width="715"]] ... ... @@ -112,53 +112,11 @@ 112 112 113 113 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_860bcf87f6ca7b98.png||alt="image-20220825100845-4.png" height="246" width="419"]] 114 114 115 -== **FX NOPROTOCOL** ==93 +== {{id name="HFX3UEthernet"/}}**FX3U Ethernet ** == 116 116 117 -Mitsubishi FX3G-RS232-BD 118 - 119 -**V-Box Settings** 120 - 121 -|=**Item**|=**Settings**|=**Note** 122 -|Protocol|Mitsubishi FX NOPROTOCOL| 123 -|Connection|RS232| 124 -|Baud rate|9600| 125 -|Data bit|7| 126 -|Parity|EVEN| 127 -|Stop bit|1| 128 -|PLC station No.|0| 129 - 130 -(% style="text-align:center" %) 131 -[[image:三菱 FN盒子通讯配置.png]] 132 - 133 -**Address List** 134 - 135 -|=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note** 136 -|(% rowspan="8" %)Bit|X|X|X o|0~~303237| 137 -|Y|Y|Y o|0~~303237| 138 -|M|M|M d|0~~99999| 139 -|T|T|T d|0~~99999| 140 -|C|C|C d|0~~99999| 141 -|S|S|S d|0~~99999| 142 -|SM|SM|SM d|8000~~9999| 143 -|Lamp|Lamp|Lamp d|0~~0| 144 -|(% rowspan="8" %)Word|X|X|X o|0~~303237| 145 -|Y|Y|Y o|0~~303237| 146 -|M|M|M d|0~~99999| 147 -|T|T|T d|0~~99999| 148 -|C|C|C d|0~~199| 149 -|D|D|D d|0~~7999| 150 -|S|S|S d|0~~99999| 151 -|SD|SD|SD d|8000~~9999| 152 - 153 -**Cable Wiring** 154 - 155 -[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_1717efe8d969a43c.png]] 156 - 157 -== **FX3U Ethernet ** == 158 - 159 159 Supported Modules: FX3U-ENET-ADP, FX3U-ENET-L 160 160 161 -**V-BOX Settings** 97 +**1)V-BOX Settings** 162 162 163 163 |Items|Settings|Note 164 164 |Protocol|Mitsubishi FX3U| ... ... @@ -166,7 +166,7 @@ 166 166 |Port No.|5009|Must be the same as the PLC setting 167 167 |PLC station No.|0| 168 168 169 -**Address List** 105 +**2)Address List** 170 170 171 171 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 172 172 |(% rowspan="7" %)Bit|X|X|X OOO|0~~377| ... ... @@ -182,19 +182,19 @@ 182 182 |SD|SD|SD DDDD|8000~~8511| 183 183 |R|R|R DDDDD|0~~32767| 184 184 185 -**Ethernet Module Settings** 121 +**3)Ethernet Module Settings** 186 186 187 187 FX3U-ENET-L module configuration 188 188 Set up the FX3U-ENET-L Ethernet module settings as follows. 189 189 Select the module location, which in this document is Module 0. 190 190 191 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_949d5d77c1d9cf1e.png||alt="image-20221116105850-1.png" height="573" width="706"]] 127 +{{id name="Iimage-20221116105850-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_949d5d77c1d9cf1e.png||alt="image-20221116105850-1.png" height="573" width="706"]] 192 192 193 193 Select "Operational setting" to enter the following screen. 194 194 195 195 The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default. 196 196 197 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dfbfdd586c855c47.png||alt="image-20221116105947-1.png" height="573" width="706"]] 133 +{{id name="Iimage-20221116105947-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dfbfdd586c855c47.png||alt="image-20221116105947-1.png" height="573" width="706"]] 198 198 199 199 Select "Open setting" to enter the setting interface, the settings are as follows. 200 200 ... ... @@ -202,7 +202,7 @@ 202 202 203 203 Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module. 204 204 205 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7c01ac15090fcc5b.png||alt="image-20221116110802-1.png" height="549" width="706"]] 141 +{{id name="Iimage-20221116110802-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7c01ac15090fcc5b.png||alt="image-20221116110802-1.png" height="549" width="706"]] 206 206 207 207 Click on "transter setup" - "PC side I/F setting", see the following figure. 208 208 ... ... @@ -210,50 +210,50 @@ 210 210 211 211 use the IP set in the "Ethernet board" to communicate directly with the network cable. 212 212 213 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d6fd9ce3b96f99e2.png||alt="image-20221116110832-2.png" height="423" width="708"]] 149 +{{id name="Iimage-20221116110832-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d6fd9ce3b96f99e2.png||alt="image-20221116110832-2.png" height="423" width="708"]] 214 214 215 215 Read and write data from the Ethernet module 216 216 217 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_690b3e57b29cfd4b.png||alt="image-20221116110907-3.png" height="549" width="706"]] 153 +{{id name="Iimage-20221116110907-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_690b3e57b29cfd4b.png||alt="image-20221116110907-3.png" height="549" width="706"]] 218 218 219 219 Set "Transter setup" to COM communication, and read or write operation as shown below 220 220 221 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b317253742f7151.png||alt="image-20221116110917-4.png" height="549" width="706"]] 157 +{{id name="Iimage-20221116110917-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b317253742f7151.png||alt="image-20221116110917-4.png" height="549" width="706"]] 222 222 223 -**PLC Settings (GX Works 2)** 159 +**4)PLC Settings (GX Works 2)** 224 224 225 225 Create a blank FX5U project 226 226 227 227 Find Current Connection in the navigation 228 228 229 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d2a46ba9c005cf38.png||alt="image-20221116111427-1.png" height="421" width="705"]] 165 +{{id name="Iimage-20221116111427-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d2a46ba9c005cf38.png||alt="image-20221116111427-1.png" height="421" width="705"]] 230 230 231 231 Select Connection Channel List 232 232 233 233 Select Ethernet board communication 234 234 235 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8f49721a3e5b0ef9.png||alt="image-20221116111451-2.png" height="421" width="705"]] 171 +{{id name="Iimage-20221116111451-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8f49721a3e5b0ef9.png||alt="image-20221116111451-2.png" height="421" width="705"]] 236 236 237 237 Select Ethernet Module 238 238 Set the IP address of the PLC 239 239 240 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e9a9e29a46a1041.png||alt="image-20221116111509-3.png" height="666" width="699"]] 176 +{{id name="Iimage-20221116111509-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e9a9e29a46a1041.png||alt="image-20221116111509-3.png" height="666" width="699"]] 241 241 242 242 Read or write PLC data, in this document is read 243 243 244 244 {{id name="Iimage-20221116111651-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_e3d629103727a423.png||alt="image-20221116111651-4.png" height="416" width="697"]] 245 245 246 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7f29923ebcb670d1.png||alt="image-20221116111727-5.png" height="416" width="697"]] 182 +{{id name="Iimage-20221116111727-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7f29923ebcb670d1.png||alt="image-20221116111727-5.png" height="416" width="697"]] 247 247 248 -**Configure the communication protocol** 184 +**4)Configure the communication protocol** 249 249 250 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b2cdc33b6eb92b67.png||alt="image-20221119101946-2.png" height="395" width="695"]] 186 +{{id name="Iimage-20221119101946-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b2cdc33b6eb92b67.png||alt="image-20221119101946-2.png" height="395" width="695"]] 251 251 252 -== **FX5U Serial ** == 188 +== {{id name="HFX5USerial"/}}**FX5U Serial ** == 253 253 254 254 Mitsubishi FX5U series PLC 255 255 256 -**V-BOX Settings** 192 +**1)V-BOX Settings** 257 257 258 258 |**Item**|**Settings**|**Note** 259 259 |Protocol|Mitsubishi FX5U| ... ... @@ -264,11 +264,8 @@ 264 264 |Stop bit|1| 265 265 |PLC station No.|1~~255|Need to be the same as PLC settings 266 266 267 -(% style="text-align:center" %) 268 -[[image:三菱 FX5U 串口协议配置.png]] 203 +**2)Address List** 269 269 270 -**Address List** 271 - 272 272 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 273 273 |(% rowspan="15" %)Bit|X|X|X o|0~~303237| 274 274 |Y|Y|Y o|0~~303237| ... ... @@ -295,36 +295,40 @@ 295 295 |D|D|D d|0~~7999| 296 296 |SD|SD|SD d|0~~11999| 297 297 298 -**PLC Settings (GX Works 3)** 231 +**3)PLC Settings (GX Works 3)** 299 299 300 300 Create a blank FX5U project 301 301 302 302 Find the 485 serial port module in the system navigation bar and double click to enter the settings. 303 303 304 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5c9cb13fac1e6c93.png?width=200&height=462&rev=1.1||alt="12.PLC Protocol_html_5c9cb13fac1e6c93.png" height="462" width="200"]] 237 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_5c9cb13fac1e6c93.png3Fwidth3D20026height3D46226rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5c9cb13fac1e6c93.png?width=200&height=462&rev=1.1||alt="12.PLC Protocol_html_5c9cb13fac1e6c93.png" height="462" width="200"]] 305 305 306 306 Select protocol in the setting item, and set parameters. 307 307 308 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_de942589ca070228.png?width=600&height=324&rev=1.1||alt="12.PLC Protocol_html_de942589ca070228.png" height="324" width="600"]] 241 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_de942589ca070228.png3Fwidth3D60026height3D32426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_de942589ca070228.png?width=600&height=324&rev=1.1||alt="12.PLC Protocol_html_de942589ca070228.png" height="324" width="600"]] 309 309 310 310 Set station number, and [Message Pattern] (Pattern 1 or Pattern 4) 311 311 312 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_387ec7d00b5feb59.png?width=600&height=323&rev=1.1||alt="12.PLC Protocol_html_387ec7d00b5feb59.png" height="323" width="600"]] 245 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_387ec7d00b5feb59.png3Fwidth3D60026height3D32326rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_387ec7d00b5feb59.png?width=600&height=323&rev=1.1||alt="12.PLC Protocol_html_387ec7d00b5feb59.png" height="323" width="600"]] 313 313 314 314 Click the [Apply] button to finish the setting. 315 315 316 316 Click download and select the items as below, then click [execute] to download the configuration to PLC. 317 317 318 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_cdef1c5ec8cc2105.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_cdef1c5ec8cc2105.png" height="434" width="600"]] 251 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_cdef1c5ec8cc2105.png3Fwidth3D60026height3D43426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_cdef1c5ec8cc2105.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_cdef1c5ec8cc2105.png" height="434" width="600"]] 319 319 320 320 As soon as download is completed, connect PLC with serial port, then configure it in the [Specify Connection Destination Connection]. 321 321 322 322 Done. 323 323 324 -**C ableWiring**257 +**4)Configure the communication protocol** 325 325 326 - **RS422**259 +{{id name="Iimage-20220825104904-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dbaddd53e9951a17.png||alt="image-20220825104904-1.png" height="1033" width="1920"]] 327 327 261 +**5)Cable Wiring** 262 + 263 +* **RS422** 264 + 328 328 {{id name="Iimage-20220825105105-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d022c5ff4cf8c68e.png||alt="image-20220825105105-2.png" height="288" width="711"]] 329 329 330 330 {{id name="Iimage-20220825105533-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50e173394c73f154.png||alt="image-20220825105533-3.png" height="246" width="420"]] ... ... @@ -405,11 +405,11 @@ 405 405 406 406 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 407 407 408 -== **L02 Serial ** == 345 +== {{id name="HL02Serial"/}}**L02 Serial ** == 409 409 410 410 Mitsubishi L02 series CPU built-in serial port. 411 411 412 -**V-BOX Settings** 349 +**1)V-BOX Settings** 413 413 414 414 |**Item**|**Settings**|**Note** 415 415 |Protocol|Mitsubishi L02| ... ... @@ -420,57 +420,56 @@ 420 420 |Stop bit|1| 421 421 |PLC station No.|1~~255|Need to be the same as PLC settings 422 422 423 -(% style="text-align:center" %) 424 -[[image:三菱 L02串口协议配置.png]] 360 +**2)Address List** 425 425 426 -**Address List** 427 - 428 428 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 429 -|(% colspan="1" rowspan="20" %)Bit 430 - |X|X|X h|0~~FFFF| 431 -|Y|Y|Y h|0~~FFFF| 432 -|M|M|M d|0~~9999| 433 -|L|L|L d|0~~9999| 434 -|F|F|F d|0~~9999| 435 -|B|B|B h|0~~FFFF| 436 -|V|V|V d|0~~2047| 437 -|TC|TC|TC d|0~~9999| 438 -|SS|SS|SS d|0~~9999| 439 -|SC|SC|SC d|0~~9999| 440 -|CS|CS|CS d|0~~9999| 441 -|CC|CC|CC d|0~~9999| 442 -|SB|SB|SB h|0~~FFFF| 443 -|SM|SM|SM d|0~~2047| 444 -|STS|STS|STS d|0~~1023| 445 -|S|S|S d|0~~9999| 446 -|DX|DX|DX h|0~~FFFF| 447 -|DY|DY|DY h|0~~FFFF| 448 -|TS|TS|TS d|0~~9999| 449 -|Dbit|Dbit|Dbit d.d|0~~99999.0~~15| 450 -|(% colspan="1" rowspan="9" %)Word 451 - |W|W|W h|0~~FFFF| 452 -|TN|TN|TN d|0~~99999| 453 -|SN|SN|SN d|0~~99999| 454 -|CN|CN|CN d|0~~99999| 455 -|R|R|R d|0~~99999| 456 -|SW|SW|SW h|0~~FFFF| 457 -|Z|Z|Z d|0~~99999| 458 -|ZR|ZR|ZR h|0~~FFFF| 459 -|D|D|D d|0~~99999| 363 +|Bit|X|X|X h|0~~FFFF| 364 +|Bit|Y|Y|Y h|0~~FFFF| 365 +|Bit|M|M|M d|0~~9999| 366 +|Bit|L|L|L d|0~~9999| 367 +|Bit|F|F|F d|0~~9999| 368 +|Bit|B|B|B h|0~~FFFF| 369 +|Bit|V|V|V d|0~~2047| 370 +|Bit|TC|TC|TC d|0~~9999| 371 +|Bit|SS|SS|SS d|0~~9999| 372 +|Bit|SC|SC|SC d|0~~9999| 373 +|Bit|CS|CS|CS d|0~~9999| 374 +|Bit|CC|CC|CC d|0~~9999| 375 +|Bit|SB|SB|SB h|0~~FFFF| 376 +|Bit|SM|SM|SM d|0~~2047| 377 +|Bit|STS|STS|STS d|0~~1023| 378 +|Bit|S|S|S d|0~~9999| 379 +|Bit|DX|DX|DX h|0~~FFFF| 380 +|Bit|DY|DY|DY h|0~~FFFF| 381 +|Bit|TS|TS|TS d|0~~9999| 382 +|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15| 383 +|Word|W|W|W h|0~~FFFF| 384 +|Word|TN|TN|TN d|0~~99999| 385 +|Word|SN|SN|SN d|0~~99999| 386 +|Word|CN|CN|CN d|0~~99999| 387 +|Word|R|R|R d|0~~99999| 388 +|Word|SW|SW|SW h|0~~FFFF| 389 +|Word|Z|Z|Z d|0~~99999| 390 +|Word|ZR|ZR|ZR h|0~~FFFF| 391 +|Word|D|D|D d|0~~99999| 460 460 461 -**Ca bleWiring**393 +**3)Communication Settings** 462 462 463 - **RS422**395 +{{id name="Iimage-20220825160648-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_cfed67f2ecb4ccec.png||alt="image-20220825160648-3.png" height="1009" width="1920"]] 464 464 465 - [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_90e38f152d639809.png||alt="image-20220825161612-8.png"height="278" width="612"]]397 +**4)Cable Wiring** 466 466 467 - [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d301e675d8224725.png||alt="image-20220825160820-4.png" height="208" width="359"]]399 +* **RS422** 468 468 469 - ==**L02Ethernet**==401 +{{id name="Iimage-20220825161612-8.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_90e38f152d639809.png||alt="image-20220825161612-8.png" height="278" width="612"]] 470 470 403 +{{id name="Iimage-20220825160820-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d301e675d8224725.png||alt="image-20220825160820-4.png" height="208" width="359"]] 404 + 405 +== {{id name="HL02Ethernet"/}}**L02 Ethernet ** == 406 + 471 471 Mitsubishi L series CPU built-in Ethernet port. 472 472 473 -**V-BOX Settings** 409 +**1)V-BOX Settings** 474 474 475 475 |**Items**|**Settings**|**Note** 476 476 |Protocol|MIT L02 CPU MELSEC| ... ... @@ -478,11 +478,41 @@ 478 478 |Port No.|1025|Must be the same as the PLC setting 479 479 |PLC station No.|0|Must be the same as the PLC setting 480 480 481 -(% style="text-align:center" %) 482 -[[image:三菱 L02以太网协议配置1.png]] 417 +**2)Address List** 483 483 484 -**PLC Settings (GX Works2 )** 419 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 420 +|Bit|X|X|X h|0~~FFFF| 421 +|Bit|Y|Y|Y h|0~~FFFF| 422 +|Bit|M|M|M d|0~~9999| 423 +|Bit|L|L|L d|0~~9999| 424 +|Bit|F|F|F d|0~~9999| 425 +|Bit|B|B|B h|0~~FFFF| 426 +|Bit|V|V|V d|0~~2047| 427 +|Bit|TC|TC|TC d|0~~9999| 428 +|Bit|SS|SS|SS d|0~~9999| 429 +|Bit|SC|SC|SC d|0~~9999| 430 +|Bit|CS|CS|CS d|0~~9999| 431 +|Bit|CC|CC|CC d|0~~9999| 432 +|Bit|SB|SB|SB h|0~~FFFF| 433 +|Bit|SM|SM|SM d|0~~2047| 434 +|Bit|STS|STS|STS d|0~~1023| 435 +|Bit|S|S|S d|0~~9999| 436 +|Bit|DX|DX|DX h|0~~FFFF| 437 +|Bit|DY|DY|DY h|0~~FFFF| 438 +|Bit|TS|TS|TS d|0~~9999| 439 +|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15| 440 +|Word|W|W|W h|0~~FFFF| 441 +|Word|TN|TN|TN d|0~~99999| 442 +|Word|SN|SN|SN d|0~~99999| 443 +|Word|CN|CN|CN d|0~~99999| 444 +|Word|R|R|R d|0~~99999| 445 +|Word|SW|SW|SW h|0~~FFFF| 446 +|Word|Z|Z|Z d|0~~99999| 447 +|Word|ZR|ZR|ZR h|0~~FFFF| 448 +|Word|D|D|D d|0~~99999| 485 485 450 +**3)PLC Settings (GX Works2 )** 451 + 486 486 Create a project 487 487 488 488 Set PLC IP, subnet mask and gateway; ... ... @@ -489,11 +489,11 @@ 489 489 490 490 Select [Binary Code] as communication data code; 491 491 492 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_776e17505f3fc6c0.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_776e17505f3fc6c0.png" height="524" width="600"]] 458 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_776e17505f3fc6c0.png3Fwidth3D60026height3D52426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_776e17505f3fc6c0.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_776e17505f3fc6c0.png" height="524" width="600"]] 493 493 494 494 Set PLC port number, for example 1025 495 495 496 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8d0d1a22d388f70b.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]] 462 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_8d0d1a22d388f70b.png3Fwidth3D60026height3D52426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8d0d1a22d388f70b.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]] 497 497 498 498 Save settings; 499 499 ... ... @@ -501,10 +501,14 @@ 501 501 502 502 Restart PLC device; 503 503 504 -**C ableWiring**470 +**4)Configure the communication protocol** 505 505 506 -[[image: https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]472 +{{id name="Iimage-20220825142659-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_fafc9b29e20178c0.png||alt="image-20220825142659-1.png" height="1010" width="1920"]] 507 507 474 +**5)Cable Wiring** 475 + 476 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1-1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 477 + 508 508 == {{id name="HQ12HSerial"/}}**Q12H Serial ** == 509 509 510 510 This Demo shows V-BOX communicate with Q12H PLC by Q02H serial Protocol ... ... @@ -515,7 +515,7 @@ 515 515 516 516 Mitsubishi QJ71E71 Ethernet communication module; 517 517 518 -**V-BOX Settings** 488 +**1)V-BOX Settings** 519 519 520 520 |**Items**|**Settings**|**Note** 521 521 |Protocol|MIT QJ71E71 MELSEC| ... ... @@ -523,10 +523,8 @@ 523 523 |Port No.|1025|Must be the same as the PLC setting 524 524 |PLC station No.|0|Must be the same as the PLC setting 525 525 526 - [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50990385ef491b9e.png||alt="image-20221119171832-5.png"height="354" width="625"]]496 +**2)Address List** 527 527 528 -**Address List** 529 - 530 530 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 531 531 |(% rowspan="18" %)Bit|X|X|X h|0~~1FFF| 532 532 |Y|Y|Y h|0~~1FFF| ... ... @@ -557,16 +557,16 @@ 557 557 |Z|Z|Z d|0~~15| 558 558 |ZR|ZR|ZR h|0~~FE7FF| 559 559 560 -**PLC Settings(GX Works2)** 528 +**3)PLC Settings(GX Works2)** 561 561 562 562 * Click [Ethernet/CC IE/MELSECNET]; 563 563 * Please select [Ethernet] as network type; 564 564 * Set station I/O number according to situation (For example, 0020 means that the module is connected to PLC CPU in first order); 565 565 * Select [Online] as Mode; 566 -* [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png||alt="image-20221119171343-2.png" height="341" width="587"]] 534 +* {{id name="Iimage-20221119171343-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png||alt="image-20221119171343-2.png" height="341" width="587"]] 567 567 * Click [Operation setting] to set IP; 568 568 * Select [Binary Code] as [Communication Data Code]; 569 -* [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png||alt="image-20221119171436-3.png" height="354" width="588"]] 537 +* {{id name="Iimage-20221119171436-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png||alt="image-20221119171436-3.png" height="354" width="588"]] 570 570 * Click [Open setting] 571 571 * Set protocol: TCP; 572 572 * Set [unpassive] in [Open system]; ... ... @@ -579,6 +579,10 @@ 579 579 * {{id name="Iimage-20221119171611-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1d8e2f4fb7c72471.png||alt="image-20221119171611-4.png" height="354" width="588"]] 580 580 * Download project into PLC and restart it 581 581 582 -**C ableWiring**550 +**4)Configure the communication protocol** 583 583 552 +{{id name="Iimage-20221119171832-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50990385ef491b9e.png||alt="image-20221119171832-5.png" height="354" width="625"]] 553 + 554 +**5)Cable Wiring** 555 + 584 584 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
- 1.2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -58.0 KB - Content
- 1.5.1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -103.4 KB - Content
- 1.5.2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -46.6 KB - Content
- 1694743608503-875.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -98.4 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_1717efe8d969a43c.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -14.8 KB - Content
- 三菱 FN盒子通讯配置.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -65.5 KB - Content
- 三菱 FX5U 串口协议配置.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -65.0 KB - Content
- 三菱 L02 以太网盒子通讯配置.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -66.5 KB - Content
- 三菱 L02串口协议配置.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -64.4 KB - Content
- 三菱 L02以太网协议配置1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -66.7 KB - Content