Changes for page Mitsubishi

Last modified by Joe on 2024/05/21 10:53

From version 56.1
edited by Theodore Xu
on 2023/09/15 11:12
Change comment: There is no comment for this version
To version 39.1
edited by Theodore Xu
on 2023/09/15 09:38
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,11 +1,11 @@
1 -== **FX3U,3G,3GA Serial ** ==
1 +== **FX1S,1N,2N Serial ** ==
2 2  
3 -Supported Series: Mitsubishi FX3U, FX3G, FX3GA series
3 +Supported Series: Mitsubishi FX1S, FX1N, FX2N series
4 4  
5 5  **V-BOX Settings**
6 6  
7 7  |**Item**|**Settings**|**Note**
8 -|Protocol|Mitsubishi FX3U/3G/3GA|
8 +|Protocol|Mitsubishi FX1S/FX1N/FX2N|
9 9  |Connection|RS422/RS485/RS232|
10 10  |Baud rate|9600~~115200|
11 11  |Data bit|7/8|
... ... @@ -15,7 +15,7 @@
15 15  
16 16  **Address List**
17 17  
18 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
18 +|**Type**|**Device registers**|**V-Box registers**|**Format**|**Range**|**Note**
19 19  |(% rowspan="7" %)Bit|X|X|Xo|0~~303237|
20 20  |Y|Y|Y o|0~~303237|
21 21  |M|M|M d|0~~99999|
... ... @@ -34,62 +34,35 @@
34 34  
35 35  **Configure the communication protocol**
36 36  
37 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_4d2a4921240d23c6.png||alt="image-20220825102649-2.png" height="1009" width="1920"]]
37 +{{id name="Iimage-20220825102844-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dc262f14b14cf564.png||alt="image-20220825102844-3.png" height="1011" width="1920"]]
38 38  
39 -**PLC Setting**
40 -
41 -Open GX Works2, create a new PLC project or open the project that has been created.
42 -Create new project: [Project]→[New]→[Series] FXCPU→[Type] FX3G/FX3GC→[OK].
43 -
44 -(% style="text-align:center" %)
45 -[[image:1.2.png]]
46 -
47 -PLC Default Parameters:
48 -[Connection type]RS422;[Baud rate]9600, [Data bit]7, [Stop bit]1,[Parity]EVEN; [Station number]0
49 -Note:The serial port parameters should be set depending on field requirements
50 -
51 -PC and PLC connection:
52 -
53 -[All connection]→[Connection 1]→[Transfer Setup Connection1]→[Serial USB]→RS-232C: PC and PLC are connected by USB to RS232 adapter,choose corresponding [COM Port]COM 5 →[Transmission speed]9.6Kbps→[setup] →[Parity]EVEN→[Data bits]7→[Stop bits]1→[OK]
54 -
55 -(% style="text-align:center" %)
56 -[[image:1.5.1.png]]
57 -
58 -Connection test:when connection is OK,the GX Works2 prompts “Successfully connected with the FX3G/FX3GCCPU.”
59 -
60 -(% style="text-align:center" %)
61 -[[image:1.5.2.png]]
62 -
63 63  **Cable Wiring**
64 64  
65 65  **RS422**
66 66  
67 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e904556bb758dfe.png||alt="image-20220825103421-5.png" height="296" width="715"]]
43 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9294a40c62eb99be.png||alt="image-20220825103350-4.png" height="284" width="723"]]
68 68  
69 69  [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_860bcf87f6ca7b98.png||alt="image-20220825100845-4.png" height="246" width="419"]]
70 70  
71 -== **FX NOPROTOCOL** ==
47 +== **FX3U,3G,3GA Serial ** ==
72 72  
73 -Mitsubishi FX3G-RS232-BD
49 +Supported Series: Mitsubishi FX3U, FX3G, FX3GA series
74 74  
75 -**V-Box Settings**
51 +**V-BOX Settings**
76 76  
77 -|=**Item**|=**Settings**|=**Note**
78 -|Protocol|Mitsubishi FX NOPROTOCOL|
79 -|Connection|RS232|
80 -|Baud rate|9600|
81 -|Data bit|7|
82 -|Parity|EVEN|
83 -|Stop bit|1|
84 -|PLC station No.|0|
53 +|**Item**|**Settings**|**Note**
54 +|Protocol|Mitsubishi FX3U/3G/3GA|
55 +|Connection|RS422/RS485/RS232|
56 +|Baud rate|9600~~115200|
57 +|Data bit|7/8|
58 +|Parity|EVEN/Odd/None|
59 +|Stop bit|1/2|
60 +|PLC station No.|1~~255|
85 85  
86 -(% style="text-align:center" %)
87 -[[image:三菱 FN盒子通讯配置.png]]
88 -
89 89  **Address List**
90 90  
91 -|=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note**
92 -|(% rowspan="8" %)Bit|X|X|X o|0~~303237|
64 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
65 +|(% rowspan="7" %)Bit|X|X|Xo|0~~303237|
93 93  |Y|Y|Y o|0~~303237|
94 94  |M|M|M d|0~~99999|
95 95  |T|T|T d|0~~99999|
... ... @@ -96,8 +96,7 @@
96 96  |C|C|C d|0~~99999|
97 97  |S|S|S d|0~~99999|
98 98  |SM|SM|SM d|8000~~9999|
99 -|Lamp|Lamp|Lamp d|0~~0|
100 -|(% rowspan="8" %)Word|X|X|X o|0~~303237|
72 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237|
101 101  |Y|Y|Y o|0~~303237|
102 102  |M|M|M d|0~~99999|
103 103  |T|T|T d|0~~99999|
... ... @@ -106,15 +106,23 @@
106 106  |S|S|S d|0~~99999|
107 107  |SD|SD|SD d|8000~~9999|
108 108  
109 -**Cable Wiring**
81 +**Configure the communication protocol**
110 110  
111 -[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_1717efe8d969a43c.png]]
83 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_4d2a4921240d23c6.png||alt="image-20220825102649-2.png" height="1009" width="1920"]]
112 112  
113 -== **FX3U Ethernet ** ==
85 +**4)Cable Wiring**
114 114  
87 +**RS422**
88 +
89 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e904556bb758dfe.png||alt="image-20220825103421-5.png" height="296" width="715"]]
90 +
91 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_860bcf87f6ca7b98.png||alt="image-20220825100845-4.png" height="246" width="419"]]
92 +
93 +== {{id name="HFX3UEthernet"/}}**FX3U Ethernet ** ==
94 +
115 115  Supported Modules: FX3U-ENET-ADP, FX3U-ENET-L
116 116  
117 -**V-BOX Settings**
97 +**1)V-BOX Settings**
118 118  
119 119  |Items|Settings|Note
120 120  |Protocol|Mitsubishi FX3U|
... ... @@ -122,7 +122,7 @@
122 122  |Port No.|5009|Must be the same as the PLC setting
123 123  |PLC station No.|0|
124 124  
125 -**Address List**
105 +**2)Address List**
126 126  
127 127  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
128 128  |(% rowspan="7" %)Bit|X|X|X OOO|0~~377|
... ... @@ -138,19 +138,19 @@
138 138  |SD|SD|SD DDDD|8000~~8511|
139 139  |R|R|R DDDDD|0~~32767|
140 140  
141 -**Ethernet Module Settings**
121 +**3)Ethernet Module Settings**
142 142  
143 143  FX3U-ENET-L module configuration
144 144   Set up the FX3U-ENET-L Ethernet module settings as follows.
145 145   Select the module location, which in this document is Module 0.
146 146  
147 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_949d5d77c1d9cf1e.png||alt="image-20221116105850-1.png" height="573" width="706"]]
127 +{{id name="Iimage-20221116105850-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_949d5d77c1d9cf1e.png||alt="image-20221116105850-1.png" height="573" width="706"]]
148 148  
149 149  Select "Operational setting" to enter the following screen.
150 150  
151 151  The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default.
152 152  
153 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dfbfdd586c855c47.png||alt="image-20221116105947-1.png" height="573" width="706"]]
133 +{{id name="Iimage-20221116105947-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dfbfdd586c855c47.png||alt="image-20221116105947-1.png" height="573" width="706"]]
154 154  
155 155  Select "Open setting" to enter the setting interface, the settings are as follows.
156 156  
... ... @@ -158,7 +158,7 @@
158 158  
159 159  Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module.
160 160  
161 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7c01ac15090fcc5b.png||alt="image-20221116110802-1.png" height="549" width="706"]]
141 +{{id name="Iimage-20221116110802-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7c01ac15090fcc5b.png||alt="image-20221116110802-1.png" height="549" width="706"]]
162 162  
163 163  Click on "transter setup" - "PC side I/F setting", see the following figure.
164 164  
... ... @@ -166,50 +166,50 @@
166 166  
167 167  use the IP set in the "Ethernet board" to communicate directly with the network cable.
168 168  
169 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d6fd9ce3b96f99e2.png||alt="image-20221116110832-2.png" height="423" width="708"]]
149 +{{id name="Iimage-20221116110832-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d6fd9ce3b96f99e2.png||alt="image-20221116110832-2.png" height="423" width="708"]]
170 170  
171 171  Read and write data from the Ethernet module
172 172  
173 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_690b3e57b29cfd4b.png||alt="image-20221116110907-3.png" height="549" width="706"]]
153 +{{id name="Iimage-20221116110907-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_690b3e57b29cfd4b.png||alt="image-20221116110907-3.png" height="549" width="706"]]
174 174  
175 175  Set "Transter setup" to COM communication, and read or write operation as shown below
176 176  
177 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b317253742f7151.png||alt="image-20221116110917-4.png" height="549" width="706"]]
157 +{{id name="Iimage-20221116110917-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b317253742f7151.png||alt="image-20221116110917-4.png" height="549" width="706"]]
178 178  
179 -**PLC Settings (GX Works 2)**
159 +**4)PLC Settings (GX Works 2)**
180 180  
181 181  Create a blank FX5U project
182 182  
183 183  Find Current Connection in the navigation
184 184  
185 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d2a46ba9c005cf38.png||alt="image-20221116111427-1.png" height="421" width="705"]]
165 +{{id name="Iimage-20221116111427-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d2a46ba9c005cf38.png||alt="image-20221116111427-1.png" height="421" width="705"]]
186 186  
187 187  Select Connection Channel List
188 188  
189 189  Select Ethernet board communication
190 190  
191 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8f49721a3e5b0ef9.png||alt="image-20221116111451-2.png" height="421" width="705"]]
171 +{{id name="Iimage-20221116111451-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8f49721a3e5b0ef9.png||alt="image-20221116111451-2.png" height="421" width="705"]]
192 192  
193 193  Select Ethernet Module
194 194   Set the IP address of the PLC
195 195  
196 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e9a9e29a46a1041.png||alt="image-20221116111509-3.png" height="666" width="699"]]
176 +{{id name="Iimage-20221116111509-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e9a9e29a46a1041.png||alt="image-20221116111509-3.png" height="666" width="699"]]
197 197  
198 198  Read or write PLC data, in this document is read
199 199  
200 200  {{id name="Iimage-20221116111651-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_e3d629103727a423.png||alt="image-20221116111651-4.png" height="416" width="697"]]
201 201  
202 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7f29923ebcb670d1.png||alt="image-20221116111727-5.png" height="416" width="697"]]
182 +{{id name="Iimage-20221116111727-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7f29923ebcb670d1.png||alt="image-20221116111727-5.png" height="416" width="697"]]
203 203  
204 -**Configure the communication protocol**
184 +**4)Configure the communication protocol**
205 205  
206 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b2cdc33b6eb92b67.png||alt="image-20221119101946-2.png" height="395" width="695"]]
186 +{{id name="Iimage-20221119101946-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b2cdc33b6eb92b67.png||alt="image-20221119101946-2.png" height="395" width="695"]]
207 207  
208 -== **FX5U Serial ** ==
188 +== {{id name="HFX5USerial"/}}**FX5U Serial ** ==
209 209  
210 210  Mitsubishi FX5U series PLC
211 211  
212 -**V-BOX Settings**
192 +**1)V-BOX Settings**
213 213  
214 214  |**Item**|**Settings**|**Note**
215 215  |Protocol|Mitsubishi FX5U|
... ... @@ -220,11 +220,8 @@
220 220  |Stop bit|1|
221 221  |PLC station No.|1~~255|Need to be the same as PLC settings
222 222  
223 -(% style="text-align:center" %)
224 -[[image:三菱 FX5U 串口协议配置.png]]
203 +**2)Address List**
225 225  
226 -**Address List**
227 -
228 228  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
229 229  |(% rowspan="15" %)Bit|X|X|X o|0~~303237|
230 230  |Y|Y|Y o|0~~303237|
... ... @@ -251,36 +251,40 @@
251 251  |D|D|D d|0~~7999|
252 252  |SD|SD|SD d|0~~11999|
253 253  
254 -**PLC Settings (GX Works 3)**
231 +**3)PLC Settings (GX Works 3)**
255 255  
256 256  Create a blank FX5U project
257 257  
258 258  Find the 485 serial port module in the system navigation bar and double click to enter the settings.
259 259  
260 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5c9cb13fac1e6c93.png?width=200&height=462&rev=1.1||alt="12.PLC Protocol_html_5c9cb13fac1e6c93.png" height="462" width="200"]]
237 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_5c9cb13fac1e6c93.png3Fwidth3D20026height3D46226rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5c9cb13fac1e6c93.png?width=200&height=462&rev=1.1||alt="12.PLC Protocol_html_5c9cb13fac1e6c93.png" height="462" width="200"]]
261 261  
262 262  Select protocol in the setting item, and set parameters.
263 263  
264 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_de942589ca070228.png?width=600&height=324&rev=1.1||alt="12.PLC Protocol_html_de942589ca070228.png" height="324" width="600"]]
241 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_de942589ca070228.png3Fwidth3D60026height3D32426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_de942589ca070228.png?width=600&height=324&rev=1.1||alt="12.PLC Protocol_html_de942589ca070228.png" height="324" width="600"]]
265 265  
266 266  Set station number, and [Message Pattern] (Pattern 1 or Pattern 4)
267 267  
268 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_387ec7d00b5feb59.png?width=600&height=323&rev=1.1||alt="12.PLC Protocol_html_387ec7d00b5feb59.png" height="323" width="600"]]
245 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_387ec7d00b5feb59.png3Fwidth3D60026height3D32326rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_387ec7d00b5feb59.png?width=600&height=323&rev=1.1||alt="12.PLC Protocol_html_387ec7d00b5feb59.png" height="323" width="600"]]
269 269  
270 270  Click the [Apply] button to finish the setting.
271 271  
272 272  Click download and select the items as below, then click [execute] to download the configuration to PLC.
273 273  
274 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_cdef1c5ec8cc2105.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_cdef1c5ec8cc2105.png" height="434" width="600"]]
251 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_cdef1c5ec8cc2105.png3Fwidth3D60026height3D43426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_cdef1c5ec8cc2105.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_cdef1c5ec8cc2105.png" height="434" width="600"]]
275 275  
276 276   As soon as download is completed, connect PLC with serial port, then configure it in the [Specify Connection Destination Connection].
277 277  
278 278  Done.
279 279  
280 -**Cable Wiring**
257 +**4)Configure the communication protocol**
281 281  
282 -**RS422**
259 +{{id name="Iimage-20220825104904-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dbaddd53e9951a17.png||alt="image-20220825104904-1.png" height="1033" width="1920"]]
283 283  
261 +**5)Cable Wiring**
262 +
263 +* **RS422**
264 +
284 284  {{id name="Iimage-20220825105105-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d022c5ff4cf8c68e.png||alt="image-20220825105105-2.png" height="288" width="711"]]
285 285  
286 286  {{id name="Iimage-20220825105533-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50e173394c73f154.png||alt="image-20220825105533-3.png" height="246" width="420"]]
... ... @@ -361,11 +361,11 @@
361 361  
362 362  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
363 363  
364 -== **L02 Serial ** ==
345 +== {{id name="HL02Serial"/}}**L02 Serial ** ==
365 365  
366 366  Mitsubishi L02 series CPU built-in serial port.
367 367  
368 -**V-BOX Settings**
349 +**1)V-BOX Settings**
369 369  
370 370  |**Item**|**Settings**|**Note**
371 371  |Protocol|Mitsubishi L02|
... ... @@ -376,57 +376,56 @@
376 376  |Stop bit|1|
377 377  |PLC station No.|1~~255|Need to be the same as PLC settings
378 378  
379 -(% style="text-align:center" %)
380 -[[image:三菱 L02串口协议配置.png]]
360 +**2)Address List**
381 381  
382 -**Address List**
383 -
384 384  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
385 -|(% colspan="1" rowspan="20" %)Bit
386 - |X|X|X h|0~~FFFF|
387 -|Y|Y|Y h|0~~FFFF|
388 -|M|M|M d|0~~9999|
389 -|L|L|L d|0~~9999|
390 -|F|F|F d|0~~9999|
391 -|B|B|B h|0~~FFFF|
392 -|V|V|V d|0~~2047|
393 -|TC|TC|TC d|0~~9999|
394 -|SS|SS|SS d|0~~9999|
395 -|SC|SC|SC d|0~~9999|
396 -|CS|CS|CS d|0~~9999|
397 -|CC|CC|CC d|0~~9999|
398 -|SB|SB|SB h|0~~FFFF|
399 -|SM|SM|SM d|0~~2047|
400 -|STS|STS|STS d|0~~1023|
401 -|S|S|S d|0~~9999|
402 -|DX|DX|DX h|0~~FFFF|
403 -|DY|DY|DY h|0~~FFFF|
404 -|TS|TS|TS d|0~~9999|
405 -|Dbit|Dbit|Dbit d.d|0~~99999.0~~15|
406 -|(% colspan="1" rowspan="9" %)Word
407 - |W|W|W h|0~~FFFF|
408 -|TN|TN|TN d|0~~99999|
409 -|SN|SN|SN d|0~~99999|
410 -|CN|CN|CN d|0~~99999|
411 -|R|R|R d|0~~99999|
412 -|SW|SW|SW h|0~~FFFF|
413 -|Z|Z|Z d|0~~99999|
414 -|ZR|ZR|ZR h|0~~FFFF|
415 -|D|D|D d|0~~99999|
363 +|Bit|X|X|X h|0~~FFFF|
364 +|Bit|Y|Y|Y h|0~~FFFF|
365 +|Bit|M|M|M d|0~~9999|
366 +|Bit|L|L|L d|0~~9999|
367 +|Bit|F|F|F d|0~~9999|
368 +|Bit|B|B|B h|0~~FFFF|
369 +|Bit|V|V|V d|0~~2047|
370 +|Bit|TC|TC|TC d|0~~9999|
371 +|Bit|SS|SS|SS d|0~~9999|
372 +|Bit|SC|SC|SC d|0~~9999|
373 +|Bit|CS|CS|CS d|0~~9999|
374 +|Bit|CC|CC|CC d|0~~9999|
375 +|Bit|SB|SB|SB h|0~~FFFF|
376 +|Bit|SM|SM|SM d|0~~2047|
377 +|Bit|STS|STS|STS d|0~~1023|
378 +|Bit|S|S|S d|0~~9999|
379 +|Bit|DX|DX|DX h|0~~FFFF|
380 +|Bit|DY|DY|DY h|0~~FFFF|
381 +|Bit|TS|TS|TS d|0~~9999|
382 +|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15|
383 +|Word|W|W|W h|0~~FFFF|
384 +|Word|TN|TN|TN d|0~~99999|
385 +|Word|SN|SN|SN d|0~~99999|
386 +|Word|CN|CN|CN d|0~~99999|
387 +|Word|R|R|R d|0~~99999|
388 +|Word|SW|SW|SW h|0~~FFFF|
389 +|Word|Z|Z|Z d|0~~99999|
390 +|Word|ZR|ZR|ZR h|0~~FFFF|
391 +|Word|D|D|D d|0~~99999|
416 416  
417 -**Cable Wiring**
393 +**3)Communication Settings**
418 418  
419 -**RS422**
395 +{{id name="Iimage-20220825160648-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_cfed67f2ecb4ccec.png||alt="image-20220825160648-3.png" height="1009" width="1920"]]
420 420  
421 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_90e38f152d639809.png||alt="image-20220825161612-8.png" height="278" width="612"]]
397 +**4)Cable Wiring**
422 422  
423 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d301e675d8224725.png||alt="image-20220825160820-4.png" height="208" width="359"]]
399 +* **RS422**
424 424  
425 -== **L02 Ethernet ** ==
401 +{{id name="Iimage-20220825161612-8.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_90e38f152d639809.png||alt="image-20220825161612-8.png" height="278" width="612"]]
426 426  
403 +{{id name="Iimage-20220825160820-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d301e675d8224725.png||alt="image-20220825160820-4.png" height="208" width="359"]]
404 +
405 +== {{id name="HL02Ethernet"/}}**L02 Ethernet ** ==
406 +
427 427  Mitsubishi L series CPU built-in Ethernet port.
428 428  
429 -**V-BOX Settings**
409 +**1)V-BOX Settings**
430 430  
431 431  |**Items**|**Settings**|**Note**
432 432  |Protocol|MIT L02 CPU MELSEC|
... ... @@ -434,11 +434,41 @@
434 434  |Port No.|1025|Must be the same as the PLC setting
435 435  |PLC station No.|0|Must be the same as the PLC setting
436 436  
437 -(% style="text-align:center" %)
438 -[[image:三菱 L02以太网协议配置1.png]]
417 +**2)Address List**
439 439  
440 -**PLC Settings (GX Works2 )**
419 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
420 +|Bit|X|X|X h|0~~FFFF|
421 +|Bit|Y|Y|Y h|0~~FFFF|
422 +|Bit|M|M|M d|0~~9999|
423 +|Bit|L|L|L d|0~~9999|
424 +|Bit|F|F|F d|0~~9999|
425 +|Bit|B|B|B h|0~~FFFF|
426 +|Bit|V|V|V d|0~~2047|
427 +|Bit|TC|TC|TC d|0~~9999|
428 +|Bit|SS|SS|SS d|0~~9999|
429 +|Bit|SC|SC|SC d|0~~9999|
430 +|Bit|CS|CS|CS d|0~~9999|
431 +|Bit|CC|CC|CC d|0~~9999|
432 +|Bit|SB|SB|SB h|0~~FFFF|
433 +|Bit|SM|SM|SM d|0~~2047|
434 +|Bit|STS|STS|STS d|0~~1023|
435 +|Bit|S|S|S d|0~~9999|
436 +|Bit|DX|DX|DX h|0~~FFFF|
437 +|Bit|DY|DY|DY h|0~~FFFF|
438 +|Bit|TS|TS|TS d|0~~9999|
439 +|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15|
440 +|Word|W|W|W h|0~~FFFF|
441 +|Word|TN|TN|TN d|0~~99999|
442 +|Word|SN|SN|SN d|0~~99999|
443 +|Word|CN|CN|CN d|0~~99999|
444 +|Word|R|R|R d|0~~99999|
445 +|Word|SW|SW|SW h|0~~FFFF|
446 +|Word|Z|Z|Z d|0~~99999|
447 +|Word|ZR|ZR|ZR h|0~~FFFF|
448 +|Word|D|D|D d|0~~99999|
441 441  
450 +**3)PLC Settings (GX Works2 )**
451 +
442 442  Create a project
443 443  
444 444  Set PLC IP, subnet mask and gateway;
... ... @@ -445,11 +445,11 @@
445 445  
446 446  Select [Binary Code] as communication data code;
447 447  
448 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_776e17505f3fc6c0.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_776e17505f3fc6c0.png" height="524" width="600"]]
458 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_776e17505f3fc6c0.png3Fwidth3D60026height3D52426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_776e17505f3fc6c0.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_776e17505f3fc6c0.png" height="524" width="600"]]
449 449  
450 450  Set PLC port number, for example 1025
451 451  
452 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8d0d1a22d388f70b.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]]
462 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_8d0d1a22d388f70b.png3Fwidth3D60026height3D52426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8d0d1a22d388f70b.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]]
453 453  
454 454  Save settings;
455 455  
... ... @@ -457,10 +457,14 @@
457 457  
458 458  Restart PLC device;
459 459  
460 -**Cable Wiring**
470 +**4)Configure the communication protocol**
461 461  
462 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
472 +{{id name="Iimage-20220825142659-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_fafc9b29e20178c0.png||alt="image-20220825142659-1.png" height="1010" width="1920"]]
463 463  
474 +**5)Cable Wiring**
475 +
476 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1-1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
477 +
464 464  == {{id name="HQ12HSerial"/}}**Q12H Serial ** ==
465 465  
466 466  This Demo shows V-BOX communicate with Q12H PLC by Q02H serial Protocol
... ... @@ -471,7 +471,7 @@
471 471  
472 472  Mitsubishi QJ71E71 Ethernet communication module;
473 473  
474 -**V-BOX Settings**
488 +**1)V-BOX Settings**
475 475  
476 476  |**Items**|**Settings**|**Note**
477 477  |Protocol|MIT QJ71E71 MELSEC|
... ... @@ -479,10 +479,8 @@
479 479  |Port No.|1025|Must be the same as the PLC setting
480 480  |PLC station No.|0|Must be the same as the PLC setting
481 481  
482 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50990385ef491b9e.png||alt="image-20221119171832-5.png" height="354" width="625"]]
496 +**2)Address List**
483 483  
484 -**Address List**
485 -
486 486  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
487 487  |(% rowspan="18" %)Bit|X|X|X h|0~~1FFF|
488 488  |Y|Y|Y h|0~~1FFF|
... ... @@ -513,16 +513,16 @@
513 513  |Z|Z|Z d|0~~15|
514 514  |ZR|ZR|ZR h|0~~FE7FF|
515 515  
516 -**PLC Settings(GX Works2)**
528 +**3)PLC Settings(GX Works2)**
517 517  
518 518  * Click [Ethernet/CC IE/MELSECNET];
519 519  * Please select [Ethernet] as network type;
520 520  * Set station I/O number according to situation (For example, 0020 means that the module is connected to PLC CPU in first order);
521 521  * Select [Online] as Mode;
522 -* [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png||alt="image-20221119171343-2.png" height="341" width="587"]]
534 +* {{id name="Iimage-20221119171343-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png||alt="image-20221119171343-2.png" height="341" width="587"]]
523 523  * Click [Operation setting] to set IP;
524 524  * Select [Binary Code] as [Communication Data Code];
525 -* [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png||alt="image-20221119171436-3.png" height="354" width="588"]]
537 +* {{id name="Iimage-20221119171436-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png||alt="image-20221119171436-3.png" height="354" width="588"]]
526 526  * Click [Open setting]
527 527  * Set protocol: TCP;
528 528  * Set [unpassive] in [Open system];
... ... @@ -535,6 +535,10 @@
535 535  * {{id name="Iimage-20221119171611-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1d8e2f4fb7c72471.png||alt="image-20221119171611-4.png" height="354" width="588"]]
536 536  * Download project into PLC and restart it
537 537  
538 -**Cable Wiring**
550 +**4)Configure the communication protocol**
539 539  
552 +{{id name="Iimage-20221119171832-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50990385ef491b9e.png||alt="image-20221119171832-5.png" height="354" width="625"]]
553 +
554 +**5)Cable Wiring**
555 +
540 540  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1.2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -58.0 KB
Content
1.5.1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -103.4 KB
Content
1.5.2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -46.6 KB
Content
1694743608503-875.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -98.4 KB
Content
xwiki_PIStudio_12.PLC+protocols_WebHome_1717efe8d969a43c.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -14.8 KB
Content
三菱 FN盒子通讯配置.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -65.5 KB
Content
三菱 FX5U 串口协议配置.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -65.0 KB
Content
三菱 L02 以太网盒子通讯配置.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -66.5 KB
Content
三菱 L02串口协议配置.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -64.4 KB
Content
三菱 L02以太网协议配置1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -66.7 KB
Content